AXIST8343AlertButton
ThedeviceisZ-Wave®enabledandfullycompatiblewithanyZ-Waveenablednetwork.ThedevicecanbesetupinaZ-Wave
networktocommunicatedirectlywithotherenddevicessuchaslightingcontrollers,ortoreportdirectlytoaZ-Wavecontrollerlike
theAXISM5065PTZNetworkCamera.
2
AXIST8343AlertButton
Solutionoverview
Solutionoverview
3
AXIST8343AlertButton
Productoverview
Productoverview
4
AXIST8343AlertButton
HowtoaddadevicetoaZ-WaveNetwork
HowtoaddadevicetoaZ-WaveNetwork
HowtoaddadevicetoaZ-WaveNetwork
Autoinclusion
ThedetectorsupportstheautoinclusionfeaturewhereitwillautomaticallyenterInclusionmodewhenrstpoweredup.Thiswill
alsoapplywhenpoweredupafterafactoryreset.
1.Carefullyremovethefrontcoverbypullingthebottomofthefrontcover.Thereisalinkbuttonwhichisusedtoputthe
deviceinlearningmode(inclusion/exclusion).
2.PutaZ-Wavecontrollerintoinclusionmode.
3.Insert2AAA-batteries(1,5V)intothebatterycompartmentwiththecorrectpolarity.TheLEDonthedeviceshouldturnON
4.TheinclusionprocessshouldbecompletedwhentheLEDstopsblinking
Manualinclusion
YoucanalsochoosetomanuallyaddtheZ-Wavedevicetoacontroldevice.Pleasefollowthestepsdescribedbelow.
Note
Forbestresults,excludethedevicebeforestartingtheinclusionprocess.Formoredetailsseetheinstallationguide
1.Pressthelinkbutton3timeswithin1.5secondstoputtheunitintolearning(inclusion/exclusion)mode.
2.TheinclusionprocessshouldbecompletedwhentheLEDstopsblinking
3.Performatestbeforeyouretthecover.
Manualexclusion
Note
Formoredetailsseetheinstallationguide
1.Detachthebatterycover.
2.Pressthelinkbutton3timeswithin1.5secondstoputtheunitintolearning(inclusion/exclusion)mode.
3.TheexclusionprocessshouldbecompletedwhentheLEDstopsblinking
4.Retthebatterycover.
HowtotesttheZ-Wavedevice
AsceneneedstobecreatedfortheAlertbuttontocontrolotherdevicesontheZ-Wavecontroller.Scenesareuserdenedelements
inthecontrollerthatdetermineswhatactionstotakewhenaneventoccurs.TheAlertbuttontriggerstheeventfortheScene
whichthencontrolsotheractivationdevicessuchasplugsordimmers,orperhapssetanalerttoalarmorDisarmmode.Analarmis
triggeredafterashortpress.Todisarm,performa10secondslongpress.
AfteryouhaveincludedthedeviceinthenetworkwiththeZ-Wavecontroller,theAlertbuttonwillsenddataaboutits
batterypowertotheGatewayafterabout2minutes.Afterthat,itwillonlysenddataoncethebuttonispressed
HowtoprogramtheZ-Wavedevice
Note
ProgrammingZ-WavedevicesusingaZ-Wavecontroller,liketheAXISM5065PTZNetworkCamera,isrecommended
forexperiencedusersonly.
5
AXIST8343AlertButton
HowtoaddadevicetoaZ-WaveNetwork
Z-WaveGroup
ThedetectorsupportseitheroneoftwoZ-WaveAssociationGroups:
Group1:Associationwith1Controllernode.
Group2:Associationwith4nodes(i.e.enddevicessuchassmartplugsandotherlightingcontrollers).Thisallowsthedetectorto
transfercommandsdirectlytoenddeviceswithouttheparticipationofthecontroller.Thishastheeffectthatwhenthedetector
triggers,alldevicesassociatedwithdetectorwillbeoperated.
Group1commands:
Whendevicestatusbeingchanged,theunitwillsendNoticationcommandtothenodeofGroup1.
Upondevicestatusbeingchanged,theunitwillcheckitsbatterystatus.Whenthebatteryleveloftheunitdropstoan
unacceptablelevel,theunitwillemitanoticationreporttothenodesofGroup1.
WhenyouperformaFactoryResettheunitwillsendaDeviceResetLocallynoticationtothenodeofGroup1.
Group2commands:
WhentheUpkeyispressed,theunitwillsendaBASICSETcommandwhichcontainsavaluethatisadjustable,tothe
nodesofGroup2.WhentheDownkeyispressed,aBASIC_SETcommandwillalsobesenttothenodesofGrouping2.
Z-WavePlus® ®
®info
RoletypeNodetypeInstallerIconUserIcon
SlaveSleepingreportZ-WavePlusnodeNoticationSensorNoticationSensor
Version
Protocollibrary3(Slave_Enhance_232_Library)
Protocolversion4.6(6.71.00)
Manufacturer
ManufacturerIDProductTypeProductID
0x03640x00040x0001
AGI(AssociationGroupInformation)table
GroupProleCommandClass&Command
(List)Nbytes
GroupName(UTF-8)
1GeneralNoticationReport
DeviceResetLocallyNotication
Lifeline
2ControlBasicSetPIRControl
Notication
EventTypeEventEvent
Parameters
Length
EventParameters
Programstarted0x0C0x01null
ProgramstartedClear0x0C0x001byte0x01
Programcompleted0x0C0x03null
ProgramcompletedClear0x0C0x001byte0x03
6
AXIST8343AlertButton
HowtoaddadevicetoaZ-WaveNetwork
Thepowerisappliedforthe
rsttime
0x080x01null
ThebatteryisLow0x080x0Anull
Battery
BatteryReport(value)Description
0x64Batteryishigh
0x10Batteryisnormal
0xFFBatteryislow
Commandclasses
Thisproductsupportsthefollowingcommandclasses:
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_TRANSPORT_SERVICE_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SECURITY_2
COMMAND_CLASS_SUPERVISION
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
COMMAND_CLASS_BATTERY
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_NOTIFICATION_V4
Wakeupcommandclass
AfterthedetectorhasbeenincludedintoaZ-Wavenetworkitwillgotosleep,butitwillsendawake-upnoticationcommandto
thecontrollerperiodicallyatapresetperiod.Thedetectorwillstayawakeforatleast10secondsandthengobacktosleepto
conservebatterylife.
Thetimeintervalbetweenwakeupnoticationcommandscanbesetinthewakeupcommandclassbasedontherangevaluesbelow:
Minimumwakeupinterval600s(10minutes)
Maximumwakeupinterval86400s(1day)
Defaultwakeupinterval14400s(4hours)
Wakeupintervalstepseconds600s(10minutes)
7
AXIST8343AlertButton
Troubleshooting
Troubleshooting
Action/StatusDescriptionLEDindication
NonodeID.TheZ-WavecontrollercouldnotndthedeviceanddidnotprovideanodeID.2-secondon,2-secondoff
for2minutes.
1.Pressthetamperswitch3timeswithin1.5secondstoputtheunitinto
exclusionmode.
2.Within1secondofstep1,pressthetamperswitchagainandholdfor5
seconds.
FactoryReset
(Thisprocedure
shouldonlybeused
whenthecontroller
isinoperable.)3.NodeIDisexcluded.Thedevicerevertstofactorydefaultstate.2-secondon,2-secondoff
for2minutes.
Failedorsuccessfulresultsinincluding/excludingtheIDcanbeviewedontheZ-WaveController.
Tablebelowliststypicalproblemsencountered:
SymptomPossibleCauseRecommendation
PressAlertButton,
LEDilluminates,but
thereceiver(s)haveno
response
1.Thedeviceisstillconnected,orhasbeen
accidentallyincluded,toapreviousnetwork.
2.DistancebetweentheAlertButtonandthe
receiver(s)toofar
3.Batteryrunninglow
1.Excludethedevicebefore
includingitagain.
2.Moveclosertothereceivers
3.Replacebatteries
Note
Forbestresults,excludethedevicebeforestartingtheinclusionprocess.Formoredetailsseetheinstallationguide.
8
AXIST8343AlertButton
Specifications
Specifications
Tondthelatestversionoftheproduct’sdatasheet,gototheproductpageonaxis.comandlocateSupport&Documentation.
Specications
BatteryAAABatteryx2
BatteryLife1year*
RangeUpto100meterslineofsight
FrequencyRange908.42MHz,922.5MHz
Specicationsaresubjecttochangewithoutnotice
*measuredat1triggersperday
9
UserManualVer.M1.3
AXIST8343AlertButtonDate:October2017
©AxisCommunicationsAB,2017PartNo.T101 17077
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

Axis T8343 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI