Solutionoverview
Solutionoverview
ThedeviceisZ-Wave®enabledandfullycompatiblewithanyZ-Waveenablednetwork.ThedevicecanbesetupinaZ-Wave
networktocommunicatedirectlywithotherenddevicessuchaslightingcontrollers,ortoreportdirectlytoaZ-Wavecontrollerlike
theAXISM5065PTZNetworkCamera.
3
AXIST8341PIRMotionSensor
Productoverview
Productoverview
PIRsensorwindow(LEDindicatorinside)
Tamperswitch
4
AXIST8341PIRMotionSensor
HowtoaddadevicetoaZ-WaveNetwork
HowtoaddadevicetoaZ-WaveNetwork
Autoinclusion
ThemotionsensorsupportstheautoinclusionfeaturewhereitwillautomaticallyenterInclusionmodewhenrstpoweredup.
Thiswillalsoapplywhenpoweredupafterafactoryreset.
1.Useascrewdrivertodetachthebatterycover.
2.PuttheAXISM5065camera(orotherZ-Wavecontroller)intoinclusionmode.
3.Insert1CR1233Vbatteriesintothebatterycompartmentwiththecorrectpolarity.TheLEDonthedeviceshouldturnON
4.EnterPINnumberintotheZ-Wavecontroller.ThePINnumbercanbefoundonthedevice.Seewhereintheinstallation
guide.
5.TheinclusionprocessshouldbecompletedwhentheLEDstopsblinking
6.Performtestbeforeyouretthebatterycover.SeeHowtotesttheZ-WaveDevice.
Manualinclusion
YoucanalsochoosetomanuallyaddtheZ-Wavedevicetoacontroldevice.Pleasefollowthestepsdescribedbelow.
Note
Forbestresults,excludethedevicebeforestartingtheinclusionprocess.Formoredetailsseetheinstallationguide.
1.Useascrewdrivertodetachthebatterycover.
2.PuttheAXISM5065camera(orotherZ-Wavecontroller)intoinclusionmode.
3.Insert1CR1233Vbatteriesintothebatterycompartmentwiththecorrectpolarity.TheLEDonthedeviceshouldturnON
4.Pressthetamperswitch3timeswithin1.5secondstoputtheunitintolearning(inclusion/exclusion)mode.
5.EnterPINnumberintotheZ-Wavecontroller.ThePINnumbercanbefoundonthedevice.Seewhereintheinstallation
guide.
6.TheinclusionprocessshouldbecompletedwhentheLEDstopsblinking.
7.Performtestbeforeyouretthebatterycover.SeeHowtotesttheZ-WaveDevice.
Manualexclusion
1.Useascrewdrivertodetachthebatterycover.
2.Pressthetamperswitch3timeswithin1.5secondstoputtheunitintolearning(inclusion/exclusion)mode.
3.TheexclusionprocessshouldbecompletedwhentheLEDstopsblinking
4.Retthebatterycover.
5
AXIST8341PIRMotionSensor
HowtotesttheZ-Wavedevice
HowtotesttheZ-Wavedevice
Warm-up
Itwilltakethemotionsensorapproximately2minutestowarmupafterthebatteryisinserted.DuringthisperiodtheLEDbehindthe
lenswillturnon.WhentheredLEDturnsoff,thewarm-upprocedureiscompletedandthedeviceisreadytodetect.
ThiswillnotaffecttheInclusion/Exclusionprocess.
Afteryouremovethebatteries,wait5secondsbeforeyouretthem.
Quicktest
1.Ifthetamperswitchisnotpressedafterinclusion,thedevicewillenter“Testmode”toallowyoutotestthedevice
beforeitismountedonthewall.
2.Ifmovementisdetectedduring“Testmode”,theLEDonthemotionsensorwilllightuponceindicatingthattheunitis
workingproperly.Retriggertimeisabout5sec.
3.Toexit“Testmode”andenternormalmode,simplypressthetamperswitchformorethan10seconds.
4.WhenthePIRistriggeredduringnormalmodetheredLEDwillnotlightup,andretriggertimeisbasedonasetupvalue.
Note
Important!MakesureyouhavecreatedaZ-Wavecontroller-eventlinkedtothebattery-statussignal.Thatwayyouwill
getanoticationoraLEDindicationwhenadevicerunsonlowbatterypower.
6
AXIST8341PIRMotionSensor
HowtoprogramtheZ-Wavedevice
HowtoprogramtheZ-Wavedevice
Note
ProgrammingZ-WavedevicesusingaZ-Wavecontrollerisrecommendedforexperiencedusersonly.
Z-WaveGroup
ThedetectorsupportseitheroneoftwoZ-WaveAssociationGroups:
Group1:Associationwith1Controllernode.
Group2:Associationwith4nodes(i.e.enddevicessuchassmartplugsandotherlightingcontrollers).Thisallowsthedetectorto
transfercommandsdirectlytoenddeviceswithouttheparticipationofthecontroller.Thishastheeffectthatwhenthedetector
triggers,alldevicesassociatedwithdetectorwillbeoperated.
Note
Association-groupsupportcanvaryamongZ-WaveControllers.TheAXISM5065supportsZ-WaveAssociationGroup1.
Group1commands:
WhenthedeviceispoweredupandalreadyisapartofaZ-Wavenetwork,theunitwillsendaNoticationReportto
thenodeinGroup1.
Whenthedetectorsensesamovement,theunitwillsendaNoticationReporttothenodesofGroup1.Oncethe
movementisstopped,aNoticationReportwillbesentagaintoGroup1.
Whenthedetector’sstatusischanged,thedevicewillcheckitsbatterystatussimultaneously.Ifthebatteryleveldropsto
anunacceptablelevel,thedevicewillemitaBatteryreporttothenodesofGroup1.
WhenyouperformaFactoryReset,theunitwillsendDeviceResetLocallyNoticationtothenodeofGroup1.
Group2commands:
Whenthedetectoristriggered,theunitwillsendBASIC_SETcommandwhichcontainsavaluetothenodesofGroup2.
Z-WavePlus® ®
®info
RoletypeNodetypeInstallerIconUserIcon
SlaveSleepingreportZ-WavePlusnodeSensorNoticationDeviceType
(HomeSecurity)
SensorNoticationDeviceType
(HomeSecurity)
Version
Protocollibrary3(Slave_Enhance_232_Library)
Protocolversion4.3D(6.71.01)
Manufacturer
ManufacturerIDProductTypeProductID
0x03640x00020x0001
AGI(AssociationGroupInformation)table
7
AXIST8341PIRMotionSensor
HowtoprogramtheZ-Wavedevice
GroupProleCommandClass&Command
(List)Nbytes
GroupName(UTF-8)
1GeneralBatteryReport
NoticationReport
DeviceResetLocallyNotication
Lifeline
2ControlBasicSetPIRControl
Notication
EventTypeEventEventParameters
Length
EventParameters
Powerisappliedforthersttime0x080x01Null
PIRTriggerON0x070x08Null
PIRTriggerOFF0x070x000x010x08
Tamperswitchpressedmore
than10seconds
0x070x000x010x03
Tamperswitchpressedmore
than10secondsandreleased
0x070x03Null
Battery
BatteryReport(value)Description
20100BatteryLevel(%)
0xFFLowBattery
Commandclasses
Thisproductsupportsthefollowingcommandclasses:
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_TRANSPORT_SERVICE_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SECURITY_2
COMMAND_CLASS_SUPERVISION
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
COMMAND_CLASS_BATTERY
COMMAND_CLASS_WAKE_UP_V2
8
AXIST8341PIRMotionSensor
HowtoprogramtheZ-Wavedevice
COMMAND_CLASS_NOTIFICATION_V4
COMMAND_CLASS_CONFIGURATION
Wakeupcommandclass
AfterthedetectorhasbeenincludedintoaZ-Wavenetworkitwillgotosleep,butitwillsendawake-upnoticationcommand
tothecontrollerperiodicallyatapresetperiod.Themotiondetectorwillstayawakeforatleast10secondsandthengobackto
sleeptoconservebatterylife.
Thetimeintervalbetweenwakeupnoticationcommandscanbesetinthewakeupcommandclassbasedontherangevaluesbelow:
Minimumwakeupinterval600s(10minutes)
Maximumwakeupinterval86400s(1day)
Defaultwakeupinterval14400s(4hours)
Wakeupintervalstepseconds600s(10minutes)
9
AXIST8341PIRMotionSensor
Z-Waveconfiguration
Z-Waveconfiguration
ThefollowinginformationisforsomeonethathassomeexperienceinsettingupaZ-Wavesystem,orsomeonethathascomputer
softwarerunningaZ-Wavecontroller.PleasegetfamiliarwiththesoftwareoftheZ-Wavecontrollerbeforegettingstarted.
Tominimizepowerconsumptionofthebattery,RFonthedeviceisswitchedoffasdefault.Inordertostartthesetupprocess,please
pressthetamperswitchoncetoturnontheRFpowerfor30seconds.YoucanthenseetheLEDstarttoblinkeverysecond.Ifsetup
isnotnishedwithin30seconds,pleasepressthetamperswitchonemoretimetocontinuethesetup
Basicsetlevel
WhenaBasicSetCommandissentandcontainsavalue,thereceiverwillprocessit.Forexample,alampmodulewould
receiveaBasicSetcommandwhichdeterminesthedimlevel.
Example:
1-99:ON(BinarySwitchDevice)
DimLevel(MultilevelSwitchDevice)
FunctionParameternumberSizeRangeDefault
BasicSetlevel111~9999
Sensitivitylevel(PIRsensoronly)
Foroptimalefciency,itisrecommendedtotestthedetector’sresponsetomovementsfromthefarthestendofthe
coverageareawhenyouuseitforthersttime.Ifmovementscannotbedetectedaccurately,simplyadjustthesensitivity
levelwiththeCongurationParameter#3.Thisparametercanbeconguredwithavaluefrom1to10,where1means
lowsensitivityand10meanshighestsensitivity.
FunctionParameternumberSizeRangeDefault
Sensitivitylevel311~106
Re-triggerintervalsetting(PIRsensoronly)
Thecongurationparameterusedtoadjustthere-triggerintervalafterthedetectorhasbeentriggeredasconguration
parameter#4.Noresponsewillbemadeduringthisintervalifamovementisdetected.Thetimeintervalcanbeset
between5secondsto3,600seconds.
FunctionParameternumberSizeRangeDefault
Retriggerinterval425~3600(sec)180
Luxlevel
Youcansetapercentagefortheluxlevelwhichdetermineswhenthelightsensorwillbeactivated.Iftheambient
illuminationdropsbelowthesetpercentage,andapersonmovesacrossorwithintheprotectedarea,thedetectorwill
emitaZ-WaveONcommand(i.e.BasicSetcommand(Value=BasicSetLevel))tothecontrollerandactivateconnected
modulesandlighting.Thepercentagecanbesetbetween1%to100%.
FunctionParameternumberSizeRangeDefault
Luxlevel511~100%20
On-offduration
Theon-offdurationsettingcanbeusefulifthedetectorisconnectedtoamoduleorlighting.Thedurationdetermineshowlongthe
module/lightingshouldstayON.Forinstance,aLampModuleturnsoff100secsafterithasbeenturnedon.Thedurationcanbe
conguredtolastbetween5to3600seconds.
10
AXIST8341PIRMotionSensor
Z-Waveconfiguration
FunctionParameternumberSizeRangeDefault
On-OffDuration625~3600(sec)15
1 1
AXIST8341PIRMotionSensor
Troubleshooting
Troubleshooting
Ifyoucan’tndwhatyou’relookingforhere,trythetroubleshootingsectionataxis.com/support
ThetablebelowexplainsthestatusintheZ-WavecontrolleraswellastheLEDindicationonthedevice.
Action/StatusDescriptionLEDindication
NonodeIDTheZ-Wavecontrollercouldnotndthedevice
anddidnotprovideanodeID.
2-secondon,2-secondofffor2minutes.
1.Pressthetamperswitch3timeswithin1.5
secondstoputthedeviceintoexclusionmode.
2.Within1secondofstep1,pressthetamper
switchagainandholduntilLEDisoff(about
5seconds).
FactoryReset
(Thisprocedureshould
onlybeusedwhen
thecontrollerisnot
responding.)
3.NodeIDisexcluded.Thedevicereverts
tofactorydefaultstateandwillbein
auto-inclusionmodefor4minutes.
2-secondon,2-secondofffor2minutes.
Failedorsuccessfulresultsinincluding/excludingtheIDcanbeviewedonaZ-Wavecontroller.
Tablebelowliststypicalproblemsencountered:
SymptomPossiblecauseRecommendation
Cannotcarryoutinclusion
andassociation.
1.Thedeviceisstillconnected,orhas
beenaccidentallyincluded,toaprevious
network.
2.TheenteredPINcodeisincorrect
3.Thebatteryhasrunoutofpower.
4.Batterypolarityisreversed.
5.Detectorismalfunctioning.
1.Excludethedevicebefore
includingitagain.
2.Makesureyouhaveentered
thecorrectPINcode
3.Replacethebattery.
4.Retthebatterywiththe
correctpolarity.
5.Ensurethedetectorisworking
properly.
Cannotcontrolthe
connectedmodules.
1.Thedeviceisstillconnected,orhas
beenaccidentallyincluded,toaprevious
network.
2.Thebatteryhasrunoutofpower.
3.Detectorismalfunctioning.
1.Excludethedevicebefore
includingitagain.
2.Replacethebattery.
3.Ensurethedetectorisworking
properly.
Thedetectorisnot
functioningproperly.
1.Thedeviceisstillconnected,orhas
beenaccidentallyincluded,toaprevious
network.
2.Thebatteryhasrunoutofpower.
3.Thedetectorismountedabovearadiator
orheater.
4.Detectorismalfunctioning.
1.Excludethedevicebefore
includingitagain.
2.Replacethebattery.
3.Removethesourceof
interferenceorreposition
itsmountinglocation.
4.Ensurethedetectorisworking
properly.
Theeventlistisnotworking
properly.
1.Thedeviceisstillconnected,orhas
beenaccidentallyincluded,toaprevious
network.
2.Thecontroller’srmwareisoutdated.
3.Thebatteryhasrunoutofpower.
1.Excludethedevicebefore
includingitagain.
2.Makesurethecontrollerhas
thelatestrmware
3.Replacethebattery.
Note
Forbestresults,excludethedevicebeforestartingtheinclusionprocess.Formoredetailsseetheinstallationguide.
12
AXIST8341PIRMotionSensor
Specifications
Specifications
Tondthelatestversionoftheproduct’sdatasheet,gototheproductpageataxis.comandlocateSupport&Documentation.
Specications
BatteryCR1233.0VLithiumBattery
Batterylife1year*
RangeUpto100m(328ft)lineofsight
Warm-uptimeAbout2minutes
PIRdetectioncoverageUpto10m(33ft)x1 1(at1.8m(5.9ft)mountingheight&25°C(77°F)
Operatingfrequency908.42MHz(US,922.5MHz(JP),868.42MHz(EU)
FCCIDFU5SP817
Specicationsaresubjecttochangewithoutnotice
*measuredat10triggersperday
13
UserManualVer.M2.1
AXIST8341PIRMotionSensorDate:September2018
©AxisCommunicationsAB,2017-2018PartNo.T101 17079
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14

Axis Communications T8341-EUR User manual

Category
Motion detectors
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI