Solutionoverview...........................................3
Productoverview...........................................4
HowtoaddadevicetoaZ-WaveNetwork......................5
HowtotesttheZ-Wavedevice................................6
HowtoprogramtheZ-Wavedevice............................7
Troubleshooting............................................9
Specications..............................................10
2
AXIST8344PowerOn/OffPlug
Solutionoverview
Solutionoverview
ThedeviceisZ-Wave®enabledandfullycompatiblewithanyZ-Waveenablednetwork.ThedevicecanbesetupinaZ-Wave
networktocommunicatedirectlywithotherenddevicessuchaslightingcontrollers,ortoreportdirectlytoaZ-Wavecontrollerlike
theAXISM5065PTZNetworkCamera.
3
AXIST8344PowerOn/OffPlug
Productoverview
Productoverview
1.Linkbutton/LEDindicator
2.Pass-throughoutlet
3.Controllableoutlet
4
AXIST8344PowerOn/OffPlug
HowtoaddadevicetoaZ-WaveNetwork
HowtoaddadevicetoaZ-WaveNetwork
Autoinclusion
ThedetectorsupportstheautoinclusionfeaturewhereitwillautomaticallyenterInclusionmodewhenrstpoweredup.
1.PutaZ-Wavecontrollerintoinclusionmode.
2.PlugtheOn/offPlugintoawalloutletnearthedevicetobecontrolled.
3.EnterPINnumberintotheZ-Wavecontroller.ThePINnumbercanbefoundonthedevice.Seewhereintheinstallation
guide.
4.TheinclusionprocessshouldbecompletedwhentheLEDstopsblinking.
5.Performtestbeforeusingthedevice.SeeHowtotesttheZ-WaveDevice.
Manualinclusion
YoucanalsochoosetomanuallyaddtheZ-Wavedevicetoacontroldevice.Pleasefollowthestepsdescribedbelow.
Note
Formoredetailsseetheinstallationguide
1.Onthefrontsideofthedevice,thereisalink-button/LED-indicatorwhichisusedtosetthedeviceinlearningmode
(inclusion,exclusion).
2.PuttheZ-Wavecontrollerininclusionmode.
3.Pressthelinkbutton3timeswithin1.5secondstoputtheunitintolearning(inclusion/exclusion)mode.
4.EnterPINnumberintotheZ-Wavecontroller.ThePINnumbercanbefoundonthedevice.Seewhereintheinstallation
guide.
5.TheprocessshouldbecompletedwhentheLEDstopsblinking.
6.Performtestbeforeusingthedevice.SeeHowtotesttheZ-WaveDevice.
Manualexclusion
1.PuttheZ-Wavecontrollerinexclusionmode.
2.Pressthelinkbutton3timeswithin1.5secondstoputtheunitintolearning(inclusion/exclusion)mode.
3.TheprocessshouldbecompletedwhentheLEDstopsblinking.
5
AXIST8344PowerOn/OffPlug
HowtotesttheZ-Wavedevice
HowtotesttheZ-Wavedevice
FromtheZ-WaveController’sinterface,turnonthenewlyaddedOn/Offplug(refertotheController’susermanualforinstructions).
TheLEDindicatorontheOn/Offplugshouldlightup.
TurnofftheOn/Offplugbeforeconnectinganyappliancetoit.
6
AXIST8344PowerOn/OffPlug
HowtoprogramtheZ-Wavedevice
HowtoprogramtheZ-Wavedevice
Note
ProgrammingZ-WavedevicesusingaZ-Wavecontrollerisrecommendedforexperiencedusersonly.
Z-WaveGroup
ThedetectorsupportseitheroneoftwoZ-WaveAssociationGroups:
Group1:Associationwith1Controllernode.
Group2:Associationwith4nodes(i.e.enddevicessuchassmartplugsandotherlightingcontrollers).Thisallowsthedetectorto
transfercommandsdirectlytoenddeviceswithouttheparticipationofthecontroller.Thishastheeffectthatwhenthedetector
triggers,alldevicesassociatedwithdetectorwillbeoperated.
Note
Association-groupsupportcanvaryamongZ-WaveControllers.TheAXISM5065supportsZ-WaveAssociationGroup1.
Group1commands:
IfthedevicealreadyisapartofaZ-Wavenetworkwhenpoweredup,thedevicewillsendaNoticationReportto
thenodeinGroup1.
Whensettingupthedeviceorchangingthedevice’sstatus,thedevicewillsendaBinarySwitchReporttothenodeof
Group1.WhenthedeviceisturnedOFF:SwitchBinaryReportValue=0x00.WhenthedeviceisturnedON:Switch
BinaryReportValue=0xFF.
DeviceReset:WhenperformingFactoryReset,thedevicewillsendDeviceResetLocallyNoticationtothenodeofGroup1.
Group2commands:
Whenthebuttononthedeviceispressed,thedevicewillsendaBasicSetcommandtothenodesofGroup2.Whenthe
deviceisturnedOFF:BasicSetValue=0x00.WhentheunitisturnedON:BasicSetValue=0xFF
Z-WavePlus® ®
®info
RoletypeNodetypeInstallerIconUserIcon
SlaveAlwaysOnZ-WavePlusnodeOnOffPowerSwitchOnOffPowerSwitch
Version
Protocollibrary3(Slave_Enhance_232_Library)
Protocolversion4.6(6.71.00)
Manufacturer
ManufacturerIDProductTypeProductID
0x03640x00040x0001
AGI(AssociationGroupInformation)table
7
AXIST8344PowerOn/OffPlug
HowtoprogramtheZ-Wavedevice
GroupProleCommandClass&Command
(List)Nbytes
GroupName(UTF-8)
1GeneralBinarySwitchReport
NoticationReport
DeviceResetLocallyNotication
Lifeline
2ControlBasicSetOn/Offcontrol(Button1)
Basic
BasicGet:Inquireaboutthestatusofthedevice.
BasicReport:Reportthestatusofthedevice.
BasicSet:Setthestatusofthedevice.
Notication
Thedevicewillsendnotications(NoticationType=0x08,Event=0x01)uponbeingpoweredon.
Conguration
Thecongurablevaluesareasfollowing:
Rememberthelaststatus:
ParameterNumberSizeRangeDefault
311/01:remember(0:donotremember)
Commandclasses
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
COMMAND_CLASS_SWITCH_BINARY
COMMAND_CLASS_SWITCH_ALL
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_TRANSPORT_SERVICE_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SECURITY_2
COMMAND_CLASS_NOTIFICATION_V4
COMMAND_CLASS_CONFIGURATION_V2
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
COMMAND_CLASS_SUPERVISION
8
AXIST8344PowerOn/OffPlug
Troubleshooting
Troubleshooting
Actio-
n/Sta-
tus
DescriptionLED
indication
No
nodeID
Status
TheZ-WavecontrollercouldnotndthedeviceanddidnotprovideanodeID.2-second
on,
2-second
off.
1.Pressthelinkbutton3timeswithin1.5secondstoputtheunitintoexclusionmode.
2.Within1secondofstep1,pressandholdthebuttonfor5seconds.
Factory
Reset
(This
proce-
dure
should
onlybe
used
when
the
con-
troller
isinop-
erable.)
3.NodeIDisdeleted.Thedevicerevertstofactorydefaultstate.2-second
on,
2-second
off.
øFailureorsuccessinincluding/excludingtheIDcanbeviewedontheZ-WaveController.
Tablebelowliststypicalproblemsencountered:
SymptomCauseofFailureRecommendation
ThedeviceisnotworkingandLEDisalwaysoffeven
whenbuttonispressed
Thedeviceisnotpluggedintotheelectrical
outletproperly
Checkpowerconnectionsto
thedevice.
Thedevice’sLEDturnson,butconnectedappliance
doesnotturnon.
Theconnectedappliancehas
itsownpowerswitchsettooff.
Theappliancerequiresa
separateremotecontroltoturn.
SettheON/OFF
switchofthe
applianceitself
toONposition
Appliances
turnedon/off
bywithremote
controlcannot
becontrolledby
thisOn/Offplug
module.
Note
Forbestresults,excludethedevicebeforestartingtheinclusionprocess.Formoredetailsseetheinstallationguide.
9
AXIST8344PowerOn/OffPlug
Specifications
Specifications
Tondthelatestversionoftheproduct’sdatasheet,gototheproductpageonaxis.comandlocateSupport&Documentation.
Specications
OperatingvoltageAC100-120V,50/60Hz
Maximumload1400W(US),1200W(JP)
RangeUpto100meterslineofsight*
Frequencyrange908.42MHz(US),922.5MHz(JP)
FCCIDFU5AN186
Specicationsaresubjecttochangewithoutnotice.
*IfthedeviceistobeusedasarepeateritmustbetherstZ-Wavedeviceaddedtothenetwork.
10
UserManualVer.M1.5
AXIST8344PowerOn/OffPlugDate:January2018
©AxisCommunicationsAB,2017-2018PartNo.T10117076
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11

Axis Communications T8344 User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI