Pg 3 of 4
Harness Retrofit Kit Install Instructions
(DI and DIL Models)
Part No. 5031425
Revision No. 0
Instructions
10) Use previously removed ground screw
(2H) to secure ground wire of control
board harness and all other ground wires of
carbonator pump deck. The ground screw
must be tightened securely to create ground
connection (See Figure 2).
11) Reinstall cover (6A) over component box
area and harness mounting bracket (6B) as
shown. The side edge (6C) of cover will
protrude into rectangular slot (6D) in
harness mounting bracket when installed
correctly. Use screws (6E) previously
removed to secure cover in place (See
Figure 6).
12) Remove existing carbonator tank and valve
leads harness by disconnecting harness
connections at the carbonator tank (7E).
Disconnect red wire (7A) and black wire
(7B) from carbonator tank probes. Remove
green ground wire (7C) from carbonator
tank grounding stud by removing the
grounding nut. Keep grounding nut for
reuse (See Figure 7).
13) Disconnect connector (8A) of carbonator
tank and valve leads harness from valve
leads (7D) of unit. Remove existing
carbonator tank and valve leads harness
from conduit tube located behind
carbonator tank (See Figure 7 and 8).
14) Install the new carbonator tank wiring
harness supplied in kit. Route and secure
new harness the same as original harness
that was removed. Make wiring harness
connections at carbonator tank (7E). The
red wire (7A) of harness connects to red
probe of carbonator tank. The black wire
(7B) of harness connects to black probe of
carbonator tank. The green ground wire
(7C) of harness connects to grounding stud
of carbonator tank and then secured with
grounding nut (See Figure 7).
Figure 7
Figure 8