SloanLED SYM-W Installation guide

Type
Installation guide
PAGE 1 OF 3
Symphony Wall Mount Luminaire
Installation Guide for SYM-W
WARNING: RISK OF FIRE, EXPLOSION,
OR ELECTRIC SHOCK
This product should be installed, inspected, and maintained
by a qualied electrician only.
Turn off electrical power before inspection, installation,
or removal.
Use only UL (or other NTRL) approved wire for
input/output connections. Minimum size 18 AWG or 14 AWG
for continuous runs.
Ensure LEDs and drivers are cool to touch when performing
maintenance. Ensure supply voltage is same as rated voltage
of luminaire.
Do not install in hazardous atmosphere.
Do not install in an application where ambient temperature
exceeds rated operating temperature.
Grounding instructions
Grounding and bonding of overall system
shall be done in accordance with NEC
Article 600 and local codes.
Prepare electrical wiring
Electrical requirements
LED driver must be supplied with
voltage specied on product label and
connected in accordance with NEC Article
600 and local codes. Use min. 75° C supply.
Before Starting
Ensure supply power is shut o.
Unpack xture and ensure there are no damaged or
missing parts.
NOTE: Fixture must be sealed where it contacts
mounting surface with a silicone sealant.
Wiring Diagram
FIXTURE
Supply
wire
AC LINE (Black/Brown)
AC NEUTRAL (White/Blue)
AC GROUND (Green/Yellow-Green)
L
DIM+
(Purple)
DIM-
(Gray)
N
G
LED Driver
3. Lift xture up and tilt slightly
toward wall mounted Quick
Mount Bracket as shown. Hook
xture base plate with Quick
Mount Bracket.
4. Fasten xture tightly to Quick
Mount Bracket.
Standard Installation
1. Uninstall Quick Mount Bracket
from xture base plate by
unscrewing two (2) hex
socket fasteners.
2. Level Quick Mount Bracket
to intended altitude. Install
Quick Mount Bracket to wall.
Quick mount
bracket
Level
bubble
Level
bubble
PAGE 2 OF 3
Symphony Wall Mount Luminaire
Installation Guide for SYM-W
Line Voltage Passive Infrared Sensor
Function and Options
The passive infrared occupancy sensor can
achieve tri-level dimming control for some
areas that require a light change notice
before switching OFF. It oers three levels
of light control: 100% – dimming light (0%,
10%, 30%, 50%) – OFF, and two periods
of selectable waiting time: motion hold time
and stand-by time. Selectable daylight
threshold and choice of detection area.
With sucient natural light,
light does not switch ON
when presence is detected.
With insucient natural
light, sensor automatically
switches light ON when
presence detected.
No presence detected, light
still dims to 0% / 10% / 30% /
50% (options) stand-by level
after hold time.
Light automatically switches
OFF after stand-by time
elapsed.
Parameter Settings by DIP Switch
1, 2 Set sensitivity
3, 4 Set hold time
5, 6 Set lux
7, 8 Stand-by light level
9, 10 Stand-by time
Utilizing Field and Introduction
BRI810-B-M8 is a passive infrared occupancy sensor,
as a xture sensors mounts in indoor light xture and
provides bi-level control. It works by 120-277 VAC
power and controls 0-10 VDC LED drivers or dimming
ballasts. All controls parameters (Hold time, daylight
sensor threshold, stand-by level, stand-by time) are
adjustable via DIP switch.
WARNING
NOTE: Warm up time is 40 seconds. After the sensor connects input power,
light will stay on 40 seconds, then go to dimming to work normally.
NOTE: Factory default setting: 100% sensitivity. Hold time: 10 seconds.
Daylight sensor: 30 lux. Dimming level: 30%. Dimming time: 60 minutes.
NOTE: When any setting is changed by DIP switch or remote control,
xture that sensor is connected to will turn ON/OFF as conrmation.
Specications
Power supply 120/277 VAC, 50/60 Hz
Maximum load @
-40° F to +158° F
(-40° C to +70° C)
Resistive/Tungsten - 600 W @ 120 V
Electronic Ballast (LED) - 800 VA @
120 V / 1200 VA @ 277 V
Dim control output 0-10 V, max. 25 mA sinking current
Detection radius/angle Max. 26 ft (8 m) / 360°
Mounting height Max. 40 ft
Humidity Max. 95% RH
Temperature -4F to +158° F (-40° C to +70° C)
Sensor Coverage
PAGE 3 OF 3
Symphony Wall Mount Luminaire
Installation Guide for SYM-W
SloanLED Headquarters
5725 Olivas Park Drive, Ventura, CA, USA
888.747.4LED (888.747.4533) • info@SloanLED.com
SloanLED.com
SloanLED Europe b.v.
Argonstraat 110, 2718 SN Zoetermeer, NL
+31 88 12 44 900 • Europe@SloanLED.com
P/N 402898 Rev B 2021-10-26
Customer service and technical support
Detection Range Setting (sensitivity)
Detection range can be reduced by
selecting combination on DIP switches
to t your specic application.
Parameter Setting by Remote Control in Manual of RC-100 Installation
Wiring Diagrams
LOAD (Red)
NEUTRAL (White)
NEUTRAL (White)
LINE (Black)
GRAY (-)
VIOLET (+)
Black
Dimming
driver
LOAD (Red)
NEUTRAL (White)
NEUTRAL (White)
LINE (Black)
Black
Dimming
driver
Close
end wire
connector
Hold Time Setting
Lamp can be set to stay ON for any period
of time between approximately 10 seconds
and a maximum of 15 minutes. Any
movement detected within the allotted time
will restart timer. It is recommended to select
the shortest time for adjusting detection
zone and for performing walk test.
Stand-by Time Setting
Stand-by Light Level Setting
Light Control Setting
Chosen lamp response threshold can be
innitely from approximately 10 - 50 lux.
Dimensions
  • Page 1 1
  • Page 2 2
  • Page 3 3