BI-LEVEL & DAYLIGHT HARVEST • 88845
INSTALL INSTRUCTIONS
Specifications subject to change without notice. Photos and line
drawings may not be to scale and are for general reference only.
!WARNING DISCONNECT POWER BEFORE INSTALLING OR SERVICING.
PARAMETER SETTING BY DIP SWITCH
OCCUPANCY SENSOR SETTINGS
Detection Range Setting (Sensitivity): Detection range is a term used
to describe the circular radius of the detection zone produced on the
ground after mounting the sensor at a height of 40ft. Flip switches 1 and 2
to the ON position as “ ”, or to the OFF position as “ ”, for adjusting detection
sensitivity of the corresponding table, as shown in Fig. 1.
Hold Time Setting: The light can be set to stay ON for any period of time
approximately between a minimum of 10 seconds and a maximum of 30
minutes. Any movement detected before this time has elapsed will re-start
the timer. It is recommended to select the shortest time for adjusting the
detection zone and for performing the walk test.
Flip switches 3, 4 and 5 to the ON position as “ ”, or to the OFF position as “ ”,
for adjusting hold time of the corresponding table, as shown in Fig. 2.
Light Sensor Setting: The chosen light response threshold ranges
from approximately 10-50 lux. Flip right-side switches 1 and 2 to the ON
position as “ ”, or to the OFF position as “ ”, for adjusting light-control of the
corresponding table, as shown in Fig. 4.
Stand-By Light Level Setting: Flip right-side switches 3 and 4 in the ON
position as “ ”, and the OFF position as “ ”, for adjusting stand-by level, as
shown in Fig. 5.
Stand-By Time Setting: Flip switches 6, 7 and 8 in the ON position as “ ”, and
the OFF position as “ ”, for adjusting stand-by time setting, as shown in Fig. 3.
From left to right:
• Switches 1 and 2 set the detection sensitivity of the sensor.
• Switches 3, 4 and 5 set the hold time of the sensor.
• Switches 6, 7 and 8 set the stand-by time.
• Switches 1 and 2 set the light sensor control.
• Switches 3 and 4 set the stand-by light level.
SENSITIVITY
Fig. 1
TIME
Fig. 2
Fig. 3 STAND-BY TIME
STAND-BY LEVEL
Fig. 5
Fig. 4 LIGHT