Alternative sensor positioning
RE 10 has an integrated room temperature sensor. This
can be spliced and extended if one wishes to measure
the room temperature in a more representative location
in the house.
1. Slacken off the two screws holding the plastic
cover.
Unscrew the four screws on the rear side of the
room unit.
Remove the installed sensor on spring terminal J3
and connect the new spliced cable.
Select “Service” in menu 8.1.1 to gain access to
menus 9.0 and the sub-menus.
About F360P
■ Select “Room unit” in menu 9.1.4 and menu 6.0
becomes available. Settings for desired room tem-
perature etc can be selected in the sub-menus to
6.0. (see MOS for 360P for more information).
About F1140/F1150/F1240/F1250
■ Select “On” in menu 9.2.6, “Room unit” in
menu 9.2.18 and menu 6.0 becomes available.
Settings for desired room temperature etc can be
selected in the sub-menus to 6.0. (see MOS for
1140/1150/1240/1250 for more information).
About ACVM 270
■ Select ”On” in menu 9.3.5 to activate RE10.
■ Select “RE10” in menu 9.3.6 and menu 6.0 becomes
available. Settings for desired room temperature
etc can be selected in the sub-menus to 6.0. (see MOS
for ACVM 270 for more information).
Electrical installation and wiring must be
carried out in accordance with the stipula-
tions in force.
About SMO 10/VVM 300
■ Select “On” in menu 9.3.4 and menu 6.0 becomes
available. Settings for desired room temperature etc
can be selected in the sub-menus to 6.0. (see MOS
for SMO 10 / VVM300 for more information).