  • Hello! I am an AI chatbot trained to assist you with the Ecler ENVIRO CM04-08-12 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
CON4Z/CON8Z/CON12Z
50.0033.01.01 1/2
4/8/12 ZONES CONSOLE
FUNCTION
CONSOLE ASSIGNED TO SEND SPOKEN MESSAGES IN THE SELECTED ZONES RESPECTING THE PRIORITIES SYSTEM
AND WITH OPTIONAL CHIME.
DESCRIPTION
Dispose the following elements:
Goose neck electret microphone
Compressor to keep the voice level constant independently of the distance
microphone - mouth.
Line balanced output (It is not necessary coaxial cable).
BUSY indicator for same or higher priority messages.
Optical indicator and/or chime acoustic monitor to know when to start speaking.
Lockable push button with led indicator to know the assigned zones.
Key to assign the message to all the zones at the same time.
Easy installation with only two telephone wires and two RJ45 connectors (8 and 6
ways respectively).
When using 8 or 13 zones one or two additional wires with 4 ways RJ45 connectors will be necessary.
FEATURES
INDICATORS:
POWER ON
: System ON
PAGING
: Message being sent by the sound system
BUSY
: System busy
CHIME
: CHIME being sent by the sound system
ZONE
: Zones selected
EXTERNAL
CONFIGURATIONS:
CHIME TYPES
: None, one, two or three tones
MONITOR CHIME
: on, off
INTERNAL
CONFIGURATIONS:
CHIME LEVEL
CONTROLS:
PAGE
: Push to speak
ZONE SELECTOR
: Keys selection zones 1, 2, 3, 4, All.
The 8/12 zones consoles will bring the according keys.
CONNECTIONS:
A
: Connector RJ45 6 pins to connect to module MCT12
D
: Connector RJ45 8 pins to connect to module MCT12
In the 8/12 zones modules there one or two additional 4-ways RJ45 connector.
CONNECTING THE 4/8/12 ZONES CONSOLE
To connect the console to the chassis link module, MCT12, refer to this module connecting notes.
You only have to consider that depending on the console model (4, 8 or 12 zones), you have to respect following connection table:
Connectors
A
B
C
D
4-zone console
YES
-
-
YES
8-zone console
YES
YES
-
YES
12-zone console
YES
YES
YES
YES
Inside the console you can only configure the chime type, its volume and whether to monitorize the chime through the console or
not.
CON4Z/CON8Z/CON12Z
2/2 50.0033.01.01
These settings have to be performed partly with the DIPSWITCHES, found on the consoles rear panel, according to following
table:
Chime Type
SW 1
SW 2
None
OFF
OFF
One tone
ON
OFF
Two tones
OFF
ON
Three tones
ON
ON
Monitor Chime
SW 3
ON
ON
OFF
OFF
In order to adjust the Monitor Chime volume, you will have to disassemble the console and set the volume by means of the pot
found inside.
/