The new redesign ILA-1000 represents a loop amplifier as professional solution for the construction of induction
loops. The ILA-1000 loop amplifier for audio transmission is used on a large scale, to supply hearing devices by
inductive audio signals.
The ILA-1000 automatic induction loop amplifier has been developed as high-quality LOOP amplifier for average
induction loops.
The system is characterized by particularly easy installation, customer-focused operation and easy use of the device
with optimum performance.
Induction loop amplifiers are very often used in churches, cinemas, theatres, sales agencies, libraries, press rooms,
lecture rooms, court rooms, counters, interpreter systems or DRIVE IN / DRIVE-THROUGH, so that wearer of
hearing devices under difficult acoustic conditions (background noises, reverberation etc.) can hear much better
without disturbing noises.
Advantages of the system:
By the inductive coupling of hearing devices, the wanted signal (audio transmission) can be heard much better
without disturbing noises. By the transmission of an audio signal through the induction loop, an acceptable wanted
signal/interfering signal ratio is reached.
Useful information:
A pure acoustic, direct sound transmission (between speaker and hearing device) caused by reverberation and
background noises considerably deteriorates the perception of the wanted signal for the wearer of the hearing device.
Receiver ILA-E:
With the induction loop receiver ILA-E a loop system can be checked or maintained in an easy way, fast and uncom-
plicated.
The device is especially suitable for responsible staff, wherever the induction transmission is installed, or for people
who need a high-quality „wireless“ hearing devices without hearing aid, f.i. for channel interpreting systems.
Planning of the loop design:
Not anywhere, where it would be desirable, acceptable or good conditions for laying the induction loop can be found.
Therefore it is necessary in the planning phase, to examine a suggested place regarding the following conditions:
- The magnetic interference fields of electrical systems, f.i. heating systems in the floor or in the roof area and the
electronic controls of lighting systems (especially in cinemas, theatres etc.)
- The influence of magnetically or electrically conductive materials in the building structure, especially where the
loop shall be installed.
- The presence of other induction loops in the neighborhood, whose signals could interfere with the signals of the
planned loops.