Symptom Possible Fault Action
There is no
power
detected
through the
amplifier (and
there is power
at the socket).
1)Powerjacknotpluggedinor
faulty.
2)Plugfusehasblown.
3)Faultypowersupplyunit.
4)Faultyamplier.
1)Checkpowerjackisrmlyplugged
in.
2)Replacefuse.Ifitblowsagain,
replacethepowersupplyunit.
3)Replacethepowersupplyunit.
4)Replaceamplier.
The red LED is
illuminated on
front panel.
1) Constant red LED:
Staorcustomermicrophonefault.
2)Red LED comes on after speech:
Inductionloopfault.
1)Ensuremicrophoneiswired
correctlyandrmlypluggedin. Try
alternative microphone to ensure
portisworking.
2)Ensureinductionloopconnectoris
wiredcorrectlyandrmlypluggedin.
I can’t hear
audio through
the induction
loop.
1)Inductionloopormicrophoneis
disconnected.
2)Looptesterhasafault.
1)Checkinstructionsforcorrect
connections and, if possible, check
the hearing device with a known
workinghearingloop.
2)Ensurelooptesterhasanewset
ofbatteries.
I can hear
interference
through
speakers
(buzzing /
whistling /
hissing).
1)Unscreenedorpoorlyearthed
third party equipment is being used
incloseproximity.
2)Internalvolumegainsettohigh.
3)Incorrectpowersupplybeing
used.
1)Switchoanythirdparty
equipment to identify the source of
interference.
2)Accesstheamplierengineers
modetoadjusttheinternalsettings.
3)Ensurethatourgroundedpower
supplyunitisconnected.
Amplifier goes
into feedback.
1)Internalvolumegainsettohigh.
2)Microphonepositionedtooclose
tospeaker.
1)Accesstheamplierengineers
modetoadjusttheinternalsettings.
2)Movethemicrophonetoa
locationfurtherfromthespeaker.
Unit does not
go into power
saving mode.
1)Ambientnoiseinareaistoohigh. 1)Switchoanyairconsystems,
desktop fans and or computers to
reduceambientnoise.
Troubleshooting
If no action is successful please seek assistance from
yourdistributororaContactainstaller.