jbc P305 User manual

Type
User manual

The JBC P305 Pedal Kit is designed to enhance your soldering experience by providing precise control over your soldering tool. With its simple connection to JBC control units, this pedal allows you to activate and deactivate the tool with a press or release, depending on your preferred mode of operation. This enables you to focus on intricate soldering tasks without the need for constant hand movements. The pedal's compact design and durable construction make it a reliable addition to your soldering workstation.

The JBC P305 Pedal Kit is designed to enhance your soldering experience by providing precise control over your soldering tool. With its simple connection to JBC control units, this pedal allows you to activate and deactivate the tool with a press or release, depending on your preferred mode of operation. This enables you to focus on intricate soldering tasks without the need for constant hand movements. The pedal's compact design and durable construction make it a reliable addition to your soldering workstation.

Pedal Kit for Control Units
P305
INSTRUCTION MANUAL
2
Pedal .............................................................1 unit
Manual .................................................... 1 unit
Ref. 0028918
Packing List
The following items are included:
This manual corresponds to the following references:
P-305
Adapter .........................................................1 unit
P005
P105
P305
P405
PORT 2
PERIPHERALS
FAE/
ROBOT
PORT 1
DDU
www.jbctools.com
1 2 3
SW1
P305
Conguration
Switch
SUPPORT
CONNECTION PEDAL
STATION TOOL
PORT 2
PERIPHERALS
FAE/
ROBOT
PORT 1
DDU
MSE
www.jbctools.com
STATION TOOL
3
Adapter for P305
Ref. 0028112
Pedal
Control Unit
Connectable control units:
See connectivity table next page.
Stand
Tool
Connection Example
Connect the tool stand and the pedal to the adapter. Then connect the adapter to the station port.
Adapter Switch To reverse the pedal functionality
choose:
NO > press to work
(normally open)
NC > release to work
(normally closed)
40 mm
50 mm
60 mm
80 mm
100 mm
130 mm 130 mm
para manuales - color gris
200 mm
300 mm
4
Pedal Compatibility
Pedals
P405* P305 P005*
Control
Unit
DI
DDE
DME
HDE
JNASE
JTSE
WS
ALE
NAE
Station ALE
Module
MS/MSE
MV/MVE
MN/MNE
Preheater
PHNE
PHSE
PHBE
PHXLE
Fume
Extractor
FAE1
FAE2
* not included, sold separately
P305 is compatible with JBC devices as shown in the table in the highlighted column.
P405* and P005* is also shown in the table below.
Marked with means pedal P405/P005 cannot be connected directly to JBCs control unit. A
module (MSE, MVE, MNE) must be used (See next pages “Pedal Set Up”).
0
c
P o w er 10%
350
Selected temp
350
o
C
A c t u al t e m p. 180
o
C
Sleep
Tool in the stand
A c t u a l temp. 20
o
C
Tool in the stand after
sleep, No heat
Hibernation
0
c
Selected temp.
350
o
C
P o w e r 10%
350
4 Counters
5
Program version
Sta tion se ttin gs
1 Temp unit
Celsius
2
Maximum temp 4000C
3
Minimum temp 2000C
4 Nitrogen mode OFF
Tool 245
Tool se ttings
1 Fix one temp
----
2
Temp levels set OFF
3
Sleep delay 0 min
Bac k
5 Help text OFF
6
Beep ON
7
Change PIN
Tool 245
Back
4 Sleep temp 180
0
C
5
Hibern delay 30 min
6
Temp adjust +0
0
C
Ma in menu
Exit
1 Reset settings
2
Station settings
3
Tool settings
Tool 245
Counters
1 Plugged hours
0
2
Working hours 0
3
Sleep hours 0
4 Hibernation hours 0
Bac k
5 No tool hours 0
6
Sleep cycles 0
7
Desold cycles 0
Menu
Enter
Menu
Enter
Menu
Enter
Menu
Enter
Fixed temp.
350
o
C
Levels ºC
270 350 400
Tool 245
Tool se ttings
1 Fix one temp
----
2
Temp levels set OFF
3
Sleep delay
Tool 245
Back
4 Sleep temp 180
0
C
5
6
Temp adjust +0
0
C
4 Counters
5
Program version
Hibern delay
Ma in menu
Exit
1 Reset settings
2
Station settings
3
Tool settings
Pedal Set Up P305
0 min
30 min
0
c
P o w er 10%
350
Selected temp
350
o
C
A c t u al t e m p . 180
o
C
Sleep
Tool in the stand
A c t u a l temp. 20
o
C
Tool in the stand after
sleep, No heat
Hibernation
0
c
Selected temp.
350
o
C
P o w e r 10%
350
4 Counters
5
Program version
Sta tion se ttin gs
1 Temp unit
Celsius
2
Maximum temp 4000C
3
Minimum temp 2000C
4 Nitrogen mode OFF
Tool 245
Tool se ttings
1 Fix one temp
----
2
Temp levels set OFF
3
Sleep delay 0 min
Bac k
5 Help text OFF
6
Beep ON
7
Change PIN
Tool 245
Back
4 Sleep temp 180
0
C
5
Hibern delay 30 min
6
Temp adjust +0
0
C
Ma in menu
Exit
1 Reset settings
2
Station settings
3
Tool settings
Tool 245
Counters
1 Plugged hours
0
2
Working hours 0
3
Sleep hours 0
4 Hibernation hours 0
Bac k
5 No tool hours 0
6
Sleep cycles 0
7
Desold cycles 0
Menu
Enter
Menu
Enter
Menu
Enter
Menu
Enter
Fixed temp.
350
o
C
Levels ºC
270 350 400
Tool 245
Tool se ttings
1 Fix one temp
----
2
Temp levels set OFF
3
Sleep delay
Tool 245
Back
4 Sleep temp 180
0
C
5
6
Temp adjust +0
0
C
4 Counters
5
Program version
Hibern delay
Ma in menu
Exit
1 Reset settings
2
Station settings
3
Tool settings
Pedal Set Up P305
0 min
30 min
5
Pedal Set Up for
- DIU (Control Unit)
- WSU (Wire Stipper Station)
2. Change Sleep Delay and Hibernation Delay to 0 min.
In order for the tool not to heat up the component before the pedal is pressed, the station’s Sleep
Delay and Hibernation Delay function must be set to 0 min.
1. Enter the Main Menu and select Tool Settings
40 mm
50 mm
60 mm
80 mm
100 mm
130 mm 130 mm
para manuales - color gris
200 mm
300 mm
350ºC
Port
1
Power
45%
Temp levels
T245
250 350 380
19:29
Port
1
T245
19:29
Sleep
Tool in the stand
Actual Temp. 180º
Delay to hibernation: 29:30
Port
1
T245
19:29
Hibernation
Actual Temp. 25ºC
Peripherals
19:29
Pedal PD_a
Module MSE
Pedal
PD_a
PD_b
None
Peripherals
19:29
Pedal PD_a
Module MSE
Peripherals
19:29
Pedal PD_a
Function Extractor
Mode released
Minimum time 0 sec
Back
Peripherals Port 2-PA
Port 2-PA
Port 2-PA
Port 2-PA
19:29
Pedal None
Module None
Module
MSE_a
None
350ºC
Port
1
Power
45%
Temp levels
T245
250 350 380
19:29
Port
1
T245
19:29
Sleep
Tool in the stand
Actual Temp. 180º
Delay to hibernation: 29:30
Port
1
T245
19:29
Hibernation
Actual Temp. 25ºC
Peripherals
19:29
Pedal PD_a
Module MSE
Pedal
PD_a
PD_b
None
Peripherals
19:29
Pedal PD_a
Module MSE
Peripherals
19:29
Pedal PD_a
Function Extractor
Mode released
Minimum time 0 sec
Back
Peripherals Port 2-PA Port 2-PA
Port 2-PA
Port 2-PA
19:29
Pedal None
Module None
Module
MSE_a
None
350ºC
Port
1
Power
45%
Temp levels
T245
250 350 380
19:29
Port
1
T245
19:29
Sleep
Tool in the stand
Actual Temp. 180º
Delay to hibernation: 29:30
Port
1
T245
19:29
Hibernation
Actual Temp. 25ºC
Peripherals
19:29
Pedal PD_a
Module MSE
Pedal
PD_a
PD_b
None
Peripherals
19:29
Pedal PD_a
Module MSE
Peripherals
19:29
Pedal PD_a
Function Extractor
Mode released
Minimum time 0 sec
Back
Peripherals Port 2-PA Port 2-PA
Port 2-PA
Port 2-PA
19:29
Pedal None
Module None
Module
MSE_a
None
6
Select how the pedal
acts: as Sleep,
Extractor (hibernation)
or as a module switch.
Select the activating
mode of the pedal
(pressed/released)
Pedal Set Up for:
- DDU, HDU (Control Units)
Select port
Note that your first
connection is denoted
as “a”, the second
being “b”, etc. (e.g.
PD_ a, PD_ b,...)
Set the duration
of the activation
time when pressing
the pedal once*.
For continuous
functioning keep the
pedal pressed.
*NB: The same can be applied inversely by continually pressing the pedal and releasing to activate.
3. Set the pedal function according to your work needs:
2. Select the pedal from the list.
1. Enter the Peripherals Menu and select the port which you want to join to the pedal.
Note: Peripheral modules - MSE, MVE or MNE - are needed to connect the pedal to DDU y HDU.
19:29
?
19:29
?
19:29
?
350
Port
1
Power
45%
Selected 350ºC
Port
1
T245
Sleep
Tool in the stand
Actual Temp. 180º
Delay to hibernation: 29:30
Port
1
T245
Hibernation
Actual Temp. 25ºC
MENU MENU MENU
C245003
Peripherals
19:29
Port 1 2 3 4
MS a
?
PERIPHERAL
Peripheral 1 plugged:
Electric Suction Module
Setup Postpone
Peripherals
19:29
Port 1 2 3 4
MS a
PD a
?
Port 2
MENU
19:29
?
Port 1
Port 3 Port 4
Hibern. Sleep
350º
C120001
C560001
Hibern.
C210001
C245903
19:29
?
19:29
?
19:29
?
350
Port
1
Power
45%
Selected 350ºC
Port
1
T245
Sleep
Tool in the stand
Actual Temp. 180º
Delay to hibernation: 29:30
Port
1
T245
Hibernation
Actual Temp. 25ºC
MENU MENU MENU
C245003
Peripherals
19:29
Port 1 2 3 4
MS a
?
PERIPHERAL
Peripheral 1 plugged:
Electric Suction Module
Setup Postpone
Peripherals
19:29
Port 1 2 3 4
MS a
PD a
?
Port 2
MENU
19:29
Port 1
Port 3 Port 4
Hibern. Sleep
350º
C120001
C560001
Hibern.
C210001
C245903
7
Note: Peripheral modules - MSE, MVE or MNE - are needed to connect the pedal to DMU.
After connecting one of the mentioned moduls to the station a popup window opens.
2. Select the module from the list of peripheral connections. Remember your first connection is
denoted as “a”, the second being “b”, etc. (e.g. MS_a, MS_b,...). Do the same with the pedal (e.g.
PD_a,...)
3. Select the port of the tool you want to link to the peripheral.
Pedal Set Up for DMU (Control Unit)
1. To configure the module MSE/MVE/MNE press Setup in the popup window.
4. Press Menu or Back to save changes.
Once set up, the module settings can be changed by entering the Peripherals Menu .
40 mm
50 mm
60 mm
80 mm
100 mm
130 mm 130 mm
para manuales - color gris
200 mm
300 mm
P005
P105
P305
P405
PORT 2
PERIPHERALS
FAE/
ROBOT
PORT 1
DDU
www.jbctools.com
1 2 3
SW1
P305
Conguration
Switch
SUPPORT
CONNECTION PEDAL
STATION TOOL
PORT 2
PERIPHERALS
FAE/
ROBOT
PORT 1
DDU
MSE
www.jbctools.com
STATION TOOL
P005
P105
P305
P405
PORT 2
PERIPHERALS
FAE/
ROBOT
PORT 1
DDU
www.jbctools.com
1 2 3
SW1
P305
Conguration
Switch
SUPPORT
CONNECTION PEDAL
STATION TOOL
PORT 2
PERIPHERALS
FAE/
ROBOT
PORT 1
DDU
MSE
www.jbctools.com
STATION TOOL
8
Tool
Control Unit
1
Example:
Chip Compoments Rework Process using Tweezers and Pedal
Adapter for P305
Connections
Connect pedal P305 to its adapter and then the adapter
to the control unit port. The tool must be connected to its
sand and the stand to the pedal adapter.
In the peripherals menu for the “Pedal Activation Mode”
choose between “pressed” and “released”.
Note: If working with P305 and its adapter, choose
the pedal funtionality at the adapter switch like shown
beside.
The Pedal is frequently used to rework components with tweezers.
AN115 JBCs adjustable nano tweezers are the most effective tool for desoldering chip components
but also it facilitates its rapid placement and soldering by using P405 pedal connected to JBC´s NAS
station.
Stand
Pedal
P305
Pedal Kit
for Control Units
Adapter Switch
To reverse the pedal functionality
choose:
NO > press to work
(normally open)
NC > release to work
(normally closed)
Adapter Switch
P005
P105
P305
P405
PORT 2
PERIPHERALS
FAE/
ROBOT
PORT 1
DDU
www.jbctools.com
1 2 3
SW1
P305
Conguration
Switch
SUPPORT
CONNECTION PEDAL
STATION TOOL
PORT 2
PERIPHERALS
FAE/
ROBOT
PORT 1
DDU
MSE
www.jbctools.com
STATION TOOL
9
3
4
Pad Cleaning
Clean the pads with JBC´s desoldering tool
DS360.
For this operation JBC´s desoldering station
DSS is needed.
Solder Paste Dispensing
Apply the solder paste amount needed to
solder the new chip component.
The use of JBC´s DPM solder paste dispenser
is recommended.
DPM
Manual
Solder Paste Dispenser
DS360
Micro
Desoldering Iron
Desoldering*
Lift the tool from the holder, press and hold
the pedal to activate the tool and desolder the
component.
Once the pedal is released the tool enters
hibernation mode and cools down.
2
* “Press Mode” previously selected
40 mm
50 mm
60 mm
80 mm
100 mm
130 mm 130 mm
para manuales - color gris
200 mm
300 mm
P005
P105
P305
P405
PORT 2
PERIPHERALS
FAE/
ROBOT
PORT 1
DDU
www.jbctools.com
1 2 3
SW1
P305
Conguration
Switch
SUPPORT
CONNECTION PEDAL
STATION TOOL
PORT 2
PERIPHERALS
FAE/
ROBOT
PORT 1
DDU
MSE
www.jbctools.com
STATION TOOL
P005
P105
P305
P405
PORT 2
PERIPHERALS
FAE/
ROBOT
PORT 1
DDU
www.jbctools.com
1 2 3
SW1
P305
Conguration
Switch
SUPPORT
CONNECTION PEDAL
STATION TOOL
PORT 2
PERIPHERALS
FAE/
ROBOT
PORT 1
DDU
MSE
www.jbctools.com
STATION TOOL
10
5
6
Placing
Do not press the pedal.
Use the tool to position the component on the
previously tinned pad.
Note: The inactive tool prevents the
component from heating up prematurely.
Soldering
Once in position press and hold the pedal to
activate the tool and perform the soldering.
Notes
11
40 mm
50 mm
60 mm
80 mm
100 mm
130 mm 130 mm
para manuales - color gris
200 mm
300 mm
This product should not be thrown in the garbage.
In accordance with the European directive 2012/19/EU, electronic equipment at the end of its life must
be collected and returned to an authorized recycling facility.
Warranty
JBC’s 2 year warranty covers this equipment against
all manufacturing defects, including the replacement
of defective parts and labour.
Warranty does not cover product wear or misuse.
In order for the warranty to be valid, equipment must
be returned, postage paid, to the dealer where it was
purchased.
40 mm
50 mm
60 mm
80 mm
100 mm
130 mm 130 mm
para manuales - color gris
200 mm
300 mm
P305
Pedal Kit for Control Units
Ref. P-305
- Pedal Cable Length: 1.9 m / 74.80 in
- Total Net Weight: 513 g / 1.13 lb
- Total Package Dimension / Weigt: 342 x 155 x 120 mm / 783 g
(L x W x H) 13.46 x 6.10 x 4.72 in / 1.73 lb
Complies with CE standards
ESD safe
Specifications
0028918-291122
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

jbc P305 User manual

Type
User manual

The JBC P305 Pedal Kit is designed to enhance your soldering experience by providing precise control over your soldering tool. With its simple connection to JBC control units, this pedal allows you to activate and deactivate the tool with a press or release, depending on your preferred mode of operation. This enables you to focus on intricate soldering tasks without the need for constant hand movements. The pedal's compact design and durable construction make it a reliable addition to your soldering workstation.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI