Cassette-Geko
FlÃĪktGroup DC-2011-0150-GB 2022-07/R10 âĒ Subject to modifications 3
Type code
* applies only to Single or Double units
** on request
Controller location
Control unit
A = Stand-alone controller
Slave unit
D = without controller
Speed levels
Steel electrical cabinet with terminal block*
A = Speed levels 1, 2, 3
Steel electrical cabinet with terminal block
or integrated control system
K = Speed levels 1, 2, 3
L = Speed levels 2, 3, 4
M = Speed levels 3, 4, 5
O = Speed levels 1, 3, 5
S = Min...Max (EC-motor)
Capacity stage
1 = Capacity stage 1
Cassette-Geko ISYteq Control System Valves
G C B 1 . U 0 W .S E 5 A 0 . 0 9 5 . 1 A V R 3 2 5 1 0 .1 1
Air-flow function
S = Single
D = Double
B = Big Single
Unit function
U = Recirculating air unit
Heating / Cooling
only Heating
0 W = Heating water (PWW)
only Cooling
W0 = Cooling water (PKW)
Cooling or Heating
WC = Cooling water (PKW) / Hea-
ting water (PWW)
Cooling and Heating
WE = Cooling water (PKW) +
electric heating
WW = Cooling water (PKW) + Hea-
ting water (PWW)
Electric motor / Thermal contact
0 = AC-motor - Built-in thermal contact
1 = AC-motor - Thermal contact wire
E = EC-motor - Built-in motor protection
Colour
5 = Outlet colour RAL 9003 (white), air outlet louvres RAL
9003 (white)
9** = Colour shade of choice (only outlet design)
Type of control
0 = Terminal block
1 = Module ISYteq 3010
2 = Module ISYteq 3020
3 = Module ISYteq 3030
Control package No.
Controller
1 = CET.ACEC
A = ISYteq LCD IW
B = ISYteq Touch 4.0
Z = without controller
7 = CMT.AC
8 = CMT.EC
E = ISYteq Touch 2.1
F = ISYteq LCD FSE50
Valve actuator
2-pipe system / 4-pipe system
T = Thermoelectric (230 V, 2-point)
Q = Thermoelectric (24 V, 2-point)
R = Reversible (230 V, 3-point)
N = Reversible (24 V, 3-point)
S = Continuous
(24 V, analogue signal 0 - 10 V)
Combination (4-pipe system)
1 = Cooling
Heating
=
=
Thermoelectric
(230 V, 2-point)
Reversible
(230 V, 3-point)
2 = Cooling
Heating
=
=
Reversible
(230 V, 3-point)
Thermoelectric
(230 V, 2-point)
3 = Cooling
Heating
=
=
Thermoelectric
(24 V, 2-point)
Reversible
(24 V, 3-point)
4 = Cooling
Heating
=
=
Reversible
(24 V, 3-point)
Thermoelectric
(24 V, 2-point)
Valve combination
2 = 2-way (Cooling), 2-way (Heating)
3 = 3-way (Cooling), 3-way (Heating)
8 = 2-way (Cooling), 3-way (Heating)
9 = 3-way (Cooling), 2-way (Heating)
P = Pressure-independent 2-way valves
(Cooling and Heating)
Secondary circuit (4-pipe system Heating)
03 = Kvs value = 0.25 (R, N, S)
04 = Kvs value = 0.40 (R, N, S)
06 = Kvs value = 0.63 (R, N, S)
10 = Kvs value = 1.0 (R, N, S)
16 = Kvs value = 1.6 (R, N, S, T, Q)
25 = Kvs value = 2.5 (R, N, S, T, Q)
35 = Kvs value = 3.5 (R, N, S)
Pressure independent 2-way valve
P1 = DN10LF (R, S, T, Q)
P2 = DN10 (R, S, T, Q)
P3 = DN15 (R, S, T, Q)
Primary circuit (2-pipe system Cooling / Heating,
4-pipe system Cooling)
03 = Kvs value = 0.25 (R, N, S)
04 = Kvs value = 0.40 (R, N, S)
06 = Kvs value = 0.63 (R, N, S)
10 = Kvs value = 1.0 (R, N, S)
16 = Kvs value = 1.6 (R, N, S, T, Q)
25 = Kvs value = 2.5 (R, N, S, T, Q)
35 = Kvs value = 3.5 (R, N, S)
Pressure independent 2-way valve
P1 = DN10LF (R, S, T, Q)
P2 = DN10 (R, S, T, Q)
P3 = DN15 (R, S, T, Q)
P4 = DN20 (R, S, T, Q)
P5 = DN25 (R, S, T, Q)
Valve ends
0 = Input / output - valve threaded fitting (male thread)
1 = Input / output - soldered fitting
2 = Input / output - shut-off valve (male thread)
3 = Input / output + shut-off valve + soldered fitting
4 = Input - shut-off valve + threaded fitting (male thread) /
output - throttle valve + threaded fitting (male thread)
5 = Input - shut-off valve + soldered fitting / output - thrott-
le valve + soldered fitting
6 = Input / output - valve threaded fitting (male thread)
- without pipe fittings
Unit type
1 = Single
2 = Double
3 = Big Single