CAME DC-DVC/08 Programming Manual

Type
Programming Manual
PROGRAMMING MANUAL
DC/08 - DVC/08
DC/08ME - DVC/08ME
FB00739-EN
English
EN
English - Manual FB00739-EN - vers. 1 -03/2017 - © Came S.p.A.
The contents of the manual are to be considered as subject to change at any time and without the need for any advance warning.
M1 M2
CN2
PROG
DAT I
A
A
D
V
MINI
USB
CN4
SW2
1
B
3
4
5
8
9
G
J
6
Page 2 - Manual FB00739-EN - ver. 1 - 03/2017 - © CAME S.p.A. - The contents of this manual are subject to change at any time without prior notice.
General warnings
Important personal safety instructions: READ CAREFULLY!
Installation, programming, commissioning and maintenance must only be performed by qualified and experienced
personnel in compliance with applicable regulations.
Wear antistatic shoes and clothing if working on the control board.
Keep hold of these warnings.
Always disconnect the power supply during cleaning or maintenance.
This product should only be used for the purpose for which it was explicitly designed. Any other use is considered
dangerous.
The manufacturer declines all liability for any damage as a result of improper, incorrect or unreasonable use.
Features
Terminal board A
+Power supply 14-18 VDC
AAudio
A
+
Data line
D
+
Video signal
V
Attention. For the manual programming of the entry panels,
the self-connection order is V1-V2-V3-V4.
Terminal board B
Solenoid lock
12 V - 1 A max
Door lock release button (NA)
Data line
Ground
Entry panel enabling output (active towards earth)
Ground
PROG key C and PROG LED 4
Programming key and LED (see 'Programming' paragraph).
The PROG LED can take on the following states:
O
On
Slow flashing
Quick flashing
Adjustments 5
loudspeaker audio
microphone audio
solenoid lock 1-10 s. (default 1 s)
VA/08
VA/08
VA/08
VA/08
LL
DVC/08
DVC/08 ME
DC/08
DC/08 ME
A
Page 3 - Manual FB00739-EN - ver. 1 - 03/2017 - © CAME S.p.A. - The contents of this manual are subject to change at any time without prior notice.
Connectors
6 CN2: Connector for the keyboard or RFID access control module.
7 CN4: Additional push button panel connector.
8 MINI USB: Programming connector.
A Switch SW2 9
Dip-1 Video line setup
OFF L<150 m
ON 150<L<250 m
Dip-2-3 Data line setup
OFF
OFF L<500 m
ON ON 500<L<1000 m
Signals J
Red - Call in progress
Green - Door open
Yellow - Conversation in progress
Blue - System busy
Technical data
Type DC/08-DVC/08 - DC/08 ME-DVC/08 ME
Power supply (VDC) 14-18
Absorption (mA) 200
Consumption in stand-by mode (mA) 90
Storage temperature (°C) -25 ÷ + 70
Operating temperature (°C) -15 ÷ + 50
IP Degree 54
Camera
Standard video PAL/NTSC
Resolution (pixel) 680x512
Minimum lighting (LUX) 1
M4M1
M2M5
M3
+12V
+D – +V1+V2
A A +D – +V3+V4
A A
M1
CN4
M2
CN2
A
A
D
V
PROG
DATI 1 2
ON
3
(*)
OUT
MINI USB
SW2
VLS/101
1
2
1
2
VA/08
VA/08
DVC/08
DVC/08ME
DC/08
DC/08ME
M4M1
M2
M5
M3
+12V
+D – +V1+V2
A A +D – +V3+V4
A A
M1
CN4
M2
CN2
A
A
D
PROG
DATI 1 2
ON
3
(*)
OUT
MINI USB
SW2
VLS/101
1
2
1
2
Page 4 - Manual FB00739-EN - ver. 1 - 03/2017 - © CAME S.p.A. - The contents of this manual are subject to change at any time without prior notice.
Connection examples
M1
CN4
M2
CN2
PROG
DATI
MINI USB
1 2
ON
3
OUT
C
NO
14
6
AC/200
VTX/100
M4M1
M2M5 M3
+12V
+D – +V1 +V2
A A +D – +V3– +V4
A A
A
A
D
6
5
75 ohm
4
3
2
1
SW2
3
4
+D – +V1 +V2
A A +D – +V3– +V4
A A
M1
CN4
M2
CN2
PROG
DATI
MINI USB
1 2
ON
3
OUT
C
NO
14
6
AC/200
A
A
D
VTX/100
6
5
4
3
2
1
VIDEO OUT
SW2
3
4
VA/08
VA/08
DC/08
DC/08ME
DC/08
DC/08ME
Page 5 - Manual FB00739-EN - ver. 1 - 03/2017 - © CAME S.p.A. - The contents of this manual are subject to change at any time without prior notice.
Connection examples
111
12
13
14
10
9
8
7
6
5
2
3
4
111
12
13
14
10
9
8
7
6
5
2
3
4
111
12
13
14
10
9
8
7
6
5
2
3
4
1
10
9
8
7
6
5
2
3
4
111
12
13
14
10
9
8
7
6
5
2
3
4
1
7
8
6
5
2
3
4
7
8
9
10
11
12
13
14
111
12
13
14
10
9
8
7
6
5
2
3
4
1
1
27
5
4
3
1
6
2
3
4
3
5
7 8
6
4
2
1
3
5
7 8
6
4
2
Page 6 - Manual FB00739-EN - ver. 1 - 03/2017 - © CAME S.p.A. - The contents of this manual are subject to change at any time without prior notice.
Manual programming of entry panels
It is possible to program only one or multiple audio/video entry
panels with the same calls (unless the use of “blind modules”
inhibits one or more).
The entry panels (connected to the same power supplier) can be
programmed with dierent types of keys, following the sequence
shown to the side.
The entry panels cannot be
programmed with dierent
types of keys.
The above specified re-
strictions can be over-
come by programming
with the PC software.
M2 M3
PROG
M2 M3
PROG
>3’’
1
BCCA
D
CB1
2
3
4
5
6
7
8
9
10
E
6
beep
3
8
4
6
9
7
5
2
1
100 °
82 °
54 °
72 °
1÷9
0
9J
<1’’
78
CC
Page 7 - Manual FB00739-EN - ver. 1 - 03/2017 - © CAME S.p.A. - The contents of this manual are subject to change at any time without prior notice.
Initial programming with ONE entry panel
Accessing programming. Press the PROG key on the power supplier 1 until the
PROG LED turns on. If the PROG LED turns o suddenly, this indicates a malfunction in
the connection between the power supplier and the entry panel. Check the connections
and return to programming.
The entry panel LEDs turn on as shown in the figure 2.Wait 5 seconds for the self-test
to be completed and then continue as described below.
Programming key type and address. Press the first key on the entry terminal C/CA/CB until the LED stops flashing as does
the backlighting LEDs 4.
Programming the call keys. Lift the receiver (if present) of the extension that you want
to programme then press the door lock release and AUX2 E buttons. On the
entry panel, press the call key to associate with the internal extension F: an acoustic
signal will confirm that the setting was stored. Hang up the receiver again, if necessary
and continue, repeating the same operations for the other extensions.
Exiting programming. Briefly press the PROG key on the power supplier G: the PROG
LED and entry panel LEDs will turn o. NOTE. If no action is performed, the procedure
will automatically end after 30 minutes.
In the case that the call buttons are ONLY located on the ADDITIONAL PUSH
BUTTON PANELS, the operation illustrated in figure C must be carried out as
illustrated in figure CC.
Programming the entry panel surveillance camera. When
programming the call buttons, with switched o monitor, the
camera’s “visual field” can be adjusted from any extension,
pressing the “self-connection 8. Starting from the default
configuration, it is possible to scroll the next ones 9 pressing
the AUX1 key or return to the previous ones with the AUX2 key
J: the setting will be automatically saved.
G
H
M2 M3
PROG
1
B
C
EF
D
Page 8 - Manual FB00739-EN - ver. 1 - 03/2017 - © CAME S.p.A. - The contents of this manual are subject to change at any time without prior notice.
External entry panel illumination level adjustment. During the call button programming of any internal receiver the external entry
panel illumination level can be adjusted up or down (with the handset lifted if present).
Pressing the “self-connection ” button on the internal receiver causes the external entry panel camera for which the illumination
level is to be adjusted to be activated. At this point, by means of the previously assigned call button (by call button or DNA) the il-
lumination level can be either incremented or decremented.
M4M1
M2
AM3
+12V
+D – +V1 +V2
A A +D – +V3 +V4
A A
MINI
USB RS232 CN2PROG
LED
DATI
LED
PROG
DL1
RFID
PROG
+
Ð
If an ETI/XIP LAN network server is present within the installation then before proceeding with the pro-
gramming described above the CN2 connector (VA/08 connector) must be disconnected and the three
jumpers inserted as shown in the diagram. Proceed with the programming as described. Once completed
reconnect the CN2 connector and remove the three jumpers.
Initial programming with MULTIPLE entry panels
Accessing programming. Press the PROG key on the power supplier 1 until the
PROG LED turns on. If the PROG LED turns o suddenly, this indicates a malfunction in
the connection between the power supplier and the entry panel. Check the connections
and return to programming.
The entry panel LEDs turn on as shown in the figure 2. Wait 5 seconds for the self-test
to be completed and then continue as described below.
Programming key type. Press the first key on the entry terminal
3 until the LED stops flashing as does the backlighting LEDs
4. Repeat the operation on all entry panels to be programmed
4 E: at the end, the signals will assume the configuration F.
In the case that the call buttons are ONLY located on the ADDITIONAL PUSH BUTTON PANELS, proceed as indicated in
NOTE on page 7.
Programming the call keys. Lift the receiver (if present) of the extension that you want
to programme then press the door lock release and AUX2 G buttons. On the
entry panel, press the call key to associate with the internal extension H: an acoustic
signal will confirm that the setting was stored. Hang up the receiver again, if necessary
j and continue, repeating the same operations for the other extensions. The operation
may only be performed from the entry panel with the LED o (PE1 in fig.F): to
change the entry panel from which the call programming is performed, press one of
the first 4 call key positions for at least 3s (or press key 1 followed by key for entry.
panels with DNA).
Exiting programming. Briefly press the PROG key on the power supplier I: the PROG
LED and entry panel LEDs will turn o. NOTE. If no action is performed, the procedure
will automatically end after 30 minutes.
Programming the entry panel camera. When programming the call buttons, the
camera’s “visual field” can be adjusted as previously described.
M2 M3
PROG
M2 M3
PROG
M2 M3
PROG
1
B
C
6
7
9J
8
D E
Page 9 - Manual FB00739-EN - ver. 1 - 03/2017 - © CAME S.p.A. - The contents of this manual are subject to change at any time without prior notice.
External entry panel illumination level adjustment. During call button programming the external entry panel illumination level
can be adjusted up or down as previously described.
Reprogramming procedure
Accessing programming. Press the PROG key on the power supplier 1 until the
PROG LED turns on. The entry panel LEDs turn on as shown in the figure 2. Wait 5
seconds for the self-test to be completed and then continue as described below.
Programming the call keys. Lift the receiver (if present) of the extension that you
want to programme then press the door lock release and AUX2 3 buttons. On
the entry panel, press the call key to be associated with the internal extension 4: an
acoustic signal will confirm that the setting was stored. Hang
up the receiver again, if necessary and continue, repeating the
same operations for the other extensions. The operation may
only be performed from the entry panel with the LED o (PE1
in 2): to change the entry panel from which call programming is
performed, press one of the first 4 call key positions for at least
3s (or press key 1 followed by key for entry. panels with DNA).
Exiting programming. Briefly press the PROG key on the power supplier E: the PROG
LED and entry panel LEDs will turn o. If no action is performed, the procedure will end
automatically after 30 minutes.
Programming key type. During the “Call button programming” phase a press and
hold down on the power supplier PROG key F. The entry panel LEDs turn on as shown
in the figure G.
Press the first key on the entry terminal to be reprogrammed G. The LED will stop to
flash as will the backlighting LEDs of the first 4 call key positions 8. Repeat the operation on all entry panels to be reprogrammed
8 and I. If all entry panels are reprogrammed, the configuration will be as illustrated in figure J.
To exit reprogramming, briefly press the PROG key on the power supplier K: the PROG LEDs and the entry panel LEDs will turn o.
If no action is performed, the procedure will end automatically after 30 minutes.
Programming the entry panel camera. When programming the call buttons, the camera’s “visual field” can be adjusted as
previously described.
M2 M3
PROG
M2 M3
PROG
M2 M3
PROG
XX beep
+
M2 M3
PROG
K
A
B
3
E
G
F
4
Page 10 - Manual FB00739-EN - ver. 1 - 03/2017 - © CAME S.p.A. - The contents of this manual are subject to change at any time without prior notice.
External entry panel illumination level adjustment. During call button programming
the external entry panel illumination level can be adjusted up or down as previously
described.
In the case that the call buttons are ONLY located on the ADDITIONAL PUSH
BUTTON PANELS, proceed as indicated in NOTE on page 7.
When adding, replacing or removing an entry panel, the acquisition of the modifications is done during the phase “Pro-
gramming key type” (figure F-K).
Programming with DNA
1
2
3
4
5
6
7
8
9
10
For this type of entry panel configuration,
refer to the previously described proce-
dures.
For this type of entry panel configuration, refer to the
procedures described below.
Accessing programming. Press the PROG key on the power supplier for more than 3 seconds 1. The entry panel LEDs turn on
as shown in the figure 2. If the PROG LED turns o suddenly, this indicates a malfunction in the connection between the power
supplier and the entry panel. Check the connections and return to programming. Repeat the operation 3 a second time. Check that
the entry panel configuration is as illustrated in figure D. Wait 5 seconds for the self-test
to be completed and then continue as described below.
Programming the call codes. Lift the receiver (if present) of the extension that you want
to programme then press the door lock release and AUX2 E buttons. Enter the
call code for the group (1 to 99) and then press F to associate the code key with the
internal extension. Hang up the receiver again, if necessary and continue, repeating the
same operations for the other extensions. The operation may only
be performed from the entry panel with the LED o (PE1 in D):
to change the entry panel from which call programming press key
1 followed by key .
Exiting programming. Briefly press the PROG key on the power supplier G: the PROG
LED and entry panel LEDs will turn o. NOTE. If no action is performed, the procedure
will automatically end after 30 minutes.
M2 M3
PROG
RFID
PROG
+
Ð
M2 M3
PROG
RFID
PROG
+
Ð
beep
12345
12345
+ +
beep
beep
+
M2 M3
PROG
RFID
PROG
+
Ð
12345
+ +
beep
A
23
5
A
B
E
34
G
4
Page 11 - Manual FB00739-EN - ver. 1 - 03/2017 - © CAME S.p.A. - The contents of this manual are subject to change at any time without prior notice.
Code and tag entry
Place the power supplier RFID PROG jumper in position “+” 1: the power supplier
PROG LED will flash slowly as will also the signalling LEDs with the configuration in
fig. 2. If the LEDs turn o suddenly, this indicates a malfunction in the connection
between the power supplier and the entry panel. Check the connections and return to
programming.
Badge. Move a badge/tag near any entry panel reader that has
already been addressed 3 and, after the confirmation tone,
press the key (group) to which the code should be assigned
4. If the maximum permitted number is exceeded (5) for each
group, an error tone will be generated.
Codes. Press enter the access code (4-8 digits) followed
by the key on the keyboard of any already
addressed entry panel E and, after the confir-
mation beep, enter the call code for the group
and then press F (or press the group key). If
the maximum permitted number for each group
is exceeded (5), an error tone will be generated.
At the end, return the RFID PROG jumper to its standby position g: the procedure will NOT end automatically!
Code and tag deletion
Place the power supplier RFID PROG jumper in position “–” 1: the power supplier PROG LED will flash slowly as will also the si-
gnalling LEDs with the configuration in fig. 2. If the LEDs turn o suddenly, this indicates
a malfunction in the connection between the power supplier and the entry panel. Check the
connections and return to programming.
Badge. Move a badge/tag near any entry panel that has already been addressed 3 and,
after the confirmation tone, repeat a second time for confirmation 4: ALL badges relative
to the GROUP will be deleted.
Codes. Press enter the access code (4-8 digits) followed by
the key on the keyboard of any already addressed entry panel
E and, after the confirmation beep, repeat a second time for
confirmation: ALL codes relative to the GROUP will be deleted.
Came S.p.A.
Via Martiri Della Libertà, 15 Via Cornia, 1/b - 1/c
31030 Dosson di Casier
Treviso - Italy
33079 Sesto al Reghena
Pordenone - Italy
(+39) 0422 4940
(+39) 0422 4941
(+39) 0434 698111
(+39) 0434 698434
www.came.com
>10’’
>1’’
beep
beep
12345 12345
beep beep
++
M2 M3
PROG
RFID
PROG
+
Ð
F
G
HIJ
English - Manual FB00739-EN - vers. 1 -03/2017 - © Came S.p.A.
The contents of the manual are to be considered as subject to change at any time and without the need for any advance warning.
Badges and Codes. Entry panel with buttons: press the call key for at least 10 seconds
F relative to the GROUP for which you want to cancel the codes and, after the beep,
press the key (briefly) a second time G. This will delete ALL codes and badges of any
type of the GROUP.
Entry panels with DNA. Enter the call code followed by the key 8 relative to the
GROUP for which you want to cancel the codes and, after the beep, enter the call code
again followed by the key 9. This will delete ALL codes of any type of the GROUP.
At the end, return the RFID PROG jumper to its standby position J: the procedure
will NOT end automatically!
The product complies with the applicable reference directives.
Dismantling and disposal. Dispose of the packaging and the device properly at the end of its life cycle, according to the regulations in force
in the country where the product is used. The recyclable components bear the symbol and code for the material.
THE DATA AND INFORMATION PROVIDED IN THIS MANUAL ARE SUBJECT TO CHANGE AT ANY TIME WITHOUT PRIOR NOTICE. MEASUREMENTS, UNLESS OTHER-
WISE INDICATED, ARE IN MILLIMETRES.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

CAME DC-DVC/08 Programming Manual

Type
Programming Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI