CAME 62700030 Installation guide

Type
Installation guide
FA0 1 53 4- EN
VA/01
EN English
CAME S.p.A.
Via Martiri della Libertà, 15
31030 Dosson di Casier
Treviso - Italy
Tel. (+39) 0422 4940
Fax (+39) 0422 4941
came.com
PRODUCT DATA AND INFORMATION
Description
62700030
VA/01 Power supply for X1 video-intercom systems 18 V DC - 1100 mA.
Description of parts
DL1 DL2
+
+12V
BIN1 BIN2 BIN3 BOUT
M1
A
1 Power supply terminal block
2 Connector for serial cable RS232 (not used)
3 Mini USB port for programming from PC
4 Entry panel programming button
5 Jumper for storing and deleting codes and TAGs
6 AUX 1 Open Collector output (max. 100 mA)
7 Common inputs
8 AUX 2 Open Collector output (max. 100 mA)
9 Entry panel power supply unit (18 V DC)
The device is electronically protected against overloads and short
circuits.
10 BUS inputs from entry panels
11 Riser output
12 USB connection warning LED (green)
13 Programming status warning LED (yellow)
FA01534-EN - 02/2022
VA/01
Page 2 - FA01534-EN - 02/2022 - © CAME S.p.A.
Technical data
MODELS VA/01
Power supply (V AC) 220-230 AC 50/60 Hz
Maximum current draw (mA AC) 350 AC
Entry panels nominal power supply (V) 18 DC
Riser power supply (V) 20 DC
Modules (no.) 12 DIN EN50022 35 x 7.5
Entry panels peak current draw (A) 1.1<15s*
Entry panel current draw (mA) 600
Maximum dissipated power (W) 25
Average life (hours) 90000
Operating temperature (°C) 0 ÷ +35
Storage temperature (°C) -25 ÷ +70
Note *1.6 A<15s with riser not connected or
powered separately
(*) Before installing the product, keep it at room temperature where it has previously been
stored or transported at a very high or very low temperature.
(**) The average product life is a purely indicative estimate. It applies to compliant usage,
installation and maintenance conditions. It is also infl uenced by other factors, such as climatic
and environmental conditions.
Size
43,5
45
7,5 57
210
106
Page 3 - FA01534-EN - 02/2022 - © CAME S.p.A.
INSTALLING
Install the power supply unit in a closed cabinet ONLY. Ensure there are ventilation grilles.
ALWAYS install the power supply unit horizontally.
Page 4 - FA01534-EN - 02/2022 - © CAME S.p.A.
INSTALLATION EXAMPLES WITH WIRING
Multi-family installation with 4 internal receivers
Use a VCM/1D cable. The distance between the power supply unit and the internal receiver must not exceed 100 m. The sum of all the sections must not exceed 1000 m.
M1
AL
B
+
M1
AL
B
+
1
2
OUT
XDV/304
34
IN
M1
B
-
+
-
+
AL
M1
AL
B
+
+12V
BIN1 BIN2 BIN3 BOUT
DL2 DL1
+
M1
A
VA/01
OPALEWIDE PEV/01
AGT V
AGT V BF
AGT V EVO
AGT V
AGT V BF
AGT V EVO
SW4
SW2SW3
SW0
Page 5 - FA01534-EN - 02/2022 - © CAME S.p.A.
Multi-family installation with 3 entry panels
Use a VCM/2D cable. Each section of cable, from power supply unit to entry panel, must not exceed 100 m. The sum of all sections of cable to the entry panels must not
exceed 300 m.
+12V
BIN1 BIN2 BIN3 BOUT
DL2 DL1
+
M1
A
VA/01
34
IN
M2
-
-
-
12V
+
-
M1
B OUT
A
1
2
1
2
VAS/100.30
M2
-
-
-
12V
+
-
M1
B OUT
M2
-
-
-
12V
+
-
M1
B OUT
XDV/304
Page 6 - FA01534-EN - 02/2022 - © CAME S.p.A.
Multi-family installation with 2 entry panels and 4 cameras
-
V4
-
V3
-
V2
V1
-
+
-
B
+12V
BIN1 BIN2 BIN3 BOUT
DL2 DL1
+
M1
A
VA/01
34
IN
M2
-
-
-
12V
+
-
M1
B OUT
M2
-
-
-
12V
+
-
M1
B OUT
XDV/304
VSC/01
V+
V–
+
V+
V–
+
V+
V–
+
V+
V–
+
Page 7 - FA01534-EN - 02/2022 - © CAME S.p.A.
CALCULATING ENTRY PANEL DRAW
Entry panel draw key
Entry panel Consumption (mA)
1 Entry panel when idle 130
2 Entry panel when idle 130
3 Entry panel when idle 35
4 Entry panel with video camera on 320
5 Entry panel with electric lock active 500
Examples with idle elements
VA/01
VA/01
Examples with active elements
VA/01
VA/01
Page 8 - FA01534-EN - 02/2022 - © CAME S.p.A.
Programming an intercommunicating group
You can download the PROGRAMMING LOG from the website docs.came.com by entering the code L20211011.
Program the intercommunicating group ONLY AFTER programming calls to each internal receiver.
DL1 DL2
+
Page 9 - FA01534-EN - 02/2022 - © CAME S.p.A.
Activation
Press and hold the 1 button for at least 25 seconds, until the LED 2 ashes quickly.
Put the jumper 3 in the [+] position.
On the internal receiver, press the intercommunicating button you wish to use to call it.
You will hear a beep to signal that the internal receiver has been added to the
intercommunicating group.
You can change the internal receiver call button by repeating the activation
procedure.
Press the button 1 to end the procedure and position the jumper 3 in neutral.
Repeat the procedure for each internal receiver you want to add to the
intercommunicating group.
You can add up to 4 internal receivers per intercommunicating group.
The procedure ends automatically after 30 minutes of inactivity.
After adding an internal receiver to an intercommunicating group, it can no longer
be excluded from that group.
Deactivation
Press and hold the 1 button for at least 25 seconds, until the LED 2 ashes quickly.
Put the jumper 3 in the [-] position.
Keep the jumper in this position for at least 20 seconds.
Press the button 1 to end the procedure and position the jumper 3 in neutral.
Page 10 - FA01534-EN - 02/2022 - © CAME S.p.A.
The VA/01 power supply unit allows for one intercommunicating group only.
To add more intercommunicating groups, install a VSE/301 selector for each intercommunicating group after the video distributor.
An intercommunicating group with VA/01 cannot coexist with other groups with VSE/301.
VA/01 VA/01
VSE/301
VSE/301 VSE/301
VA/01
XDV/304 XDV/304
XDV/304
Page 11 - FA01534-EN - 02/2022 - © CAME S.p.A.
General precautions
The product, in its original packaging supplied by the manufacturer must only be transported in a closed environment (railway carriage, containers, closed vehicles).
If the product malfunctions, stop using it and contact customer services at [email protected] or via the telephone number on the website.
The manufacture date is provided in the production batch printed on the product label. If necessary, contact us at https://www.came.com/global/en/contact-us.
The general conditions of sale are given in the o cial CAME price lists.
Dismantling and disposal
Dispose of the packaging and the device responsibly at the end of its life cycle, in compliance with the laws in force in the country where the product is used. The recyclable components
are marked with the material symbol and ID.
THE DATA AND INFORMATION IN THIS MANUAL MAY BE CHANGED AT ANY TIME AND WITHOUT NOTICE.
THE MEASUREMENTS, UNLESS OTHERWISE STATED, ARE IN MILLIMETRES.
Legislative references
This product complies with the applicable standards in force at the time of manufacturing.
© CAME S.p.A. - The contents of this manual may be changed at any time and without notice. - Translation of the original instructions
CAME S.p.A.
Via Martiri della Libertà, 15
31030 Dosson di Casier
Treviso - Italy
[email protected] - www.came.com
Tel. (+39) 0422 4940
Fax (+39) 0422 4941
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

CAME 62700030 Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI