M 4201

sensolus M 4201 User manual

  • Hello! I am an AI chatbot trained to assist you with the sensolus M 4201 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
www.sensolus.com | [email protected]om
Sense M 4201 installation manual
A sensor and a magnet
Advice for the magnet and sensor setup
The recommended installaon is the magnet frontal facing the
sensor with no distance between them. This means sensor and
magnet touch each other to detect the 'closed' status.
The maximum distance between the sensor and the magnet to sll
detect the 'closed' status is 5 mm. Installaon on brackets might be
needed to create a perfect installaon.
The sensor can be glued to any at sur-
face. This is a permanent soluon.
Sensolus recommends the use of Sabatack
780 or Tech 7 to glue materials.
Screw or M6 bolt
MAG L 0001
We recommend that the head of the screw
does not protrude when you fasten the
magnet with screws.
MAG L 0001
Mounng the magnet with screws Mounng the magnet with glue
The magnet can be glued to any at
surface. Use glue when drilling holes is
dicult.
max 5 mm
Front facing installaon is recommended
90° angle installaon
When installing the sensor and magnet at an angle of 90(degrees
sign) they have to touch each other to detect the 'closed' status.
No distance between sensor and magnet is accepted to ensure
proper funconing.
When installing the sensor and magnet side by side they have to
touch each other to detect the 'closed' status.
No distance between sensor and magnet is accepted to ensure
proper funconing.
Side by side installaon
The magnec sensor Sense M 4201 is shipped with a corresponding MAG L 0001.
To work correctly it is important that both sensor and the magnet are posioned precisely.
If they are not correctly aligned the closed state will never be detected.
Mounng the sensor
Sensor orientaon
The sensor can be turned around it’s central axis, this will have no
impact on the working of the sensor.
/