Page 2 - Manual FA01395-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructionsPage 2 - Manual FA01395-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
General Notes
• Read the instructions carefully before beginning the installation and carry out the actions as
specifi ed by the manufacturer.
• The installation, programming, commissioning and maintenance of the product must only be carried
out by qualifi ed technicians, properly trained in compliance with the regulations in force, including
health and safety measures and the disposal of packaging.
• The installer must ensure that the information for the user, where there is any, is provided and
delivered.
• Before carrying out any cleaning or maintenance operation, disconnect the devices from the
power supply.
• The equipment must only be used for the purpose for which it was expressly designed.
• The manufacturer declines all liability for any damage as a result of improper, incorrect or un-
reasonable use.
eventuali danni derivanti da usi impropri, erronei ed irragionevoli.
The product complies with the applicable reference directives.
The data and information provided in this manual are subject to change at any time with-
out prior notice. Measurements, unless otherwise indicated, are in millimetres.
AGATA VC-V
Wall mounting
Remove the unit from the metallic support by sliding it after pressing the plastic button (fi gure ).
Attach the wall bracket to the round recessed box Ø 60mm (fi gure ), the rectangular box 503
(Figure and ), the rectangular box 506E (Figure ), or the Ophera recessed box (PHI) using
the provided screws and observing the TOP indication. To ensure greater stability to the mounting
surface, secure box with screws and anchors provided.
The recessed box must be fi tted at a suitable height in relation to the user. Avoid excessive tight-
ening of the screws. Once the connections have been made, hook the video terminal to the metal
support (fi gure -). To release the unit from the metal support, press the plastic hook and lift
the terminal (fi gure ).
Terminal board M1
Doorbell
+
BBUS line input
–+ B
CL.RES
M/S
M1
CL.RES
XDV/304
CL.RES CL.RES
1 2 3
3sec
... bee
p
Page 3 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 3 - Manual FA01395-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructionsPage 3 - Manual FA01395-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
Resistive load termination
MASTER/SLAVE selection
In case of simultaneous call, the audio/video communication will
be activated on the MASTER extension only.
Technical features
T
y
pe AGATA VC-V
Power supply from BUS 15÷20 VD
Absorption 175 mA max (<1 mA stand-
by)
Single LED Absorption 1 mA (1 мА)
Storage temperature -25°C +70 °C
Operating temperature +5°C +40°C
IP Degree IP30
Video signal system PAL/NTSC
Display LCD TFT 3,5”
Programming
For call programming, see the entry panel documentation.
Accessing programming. Press and hold the key for 3 seconds. A brief acoustic signal and
the blinking LED will confi rm that programming has been accessed .
Programming the melody associated to the call from the entry panel (1 acoustic signal).
To hear the melodies in sequence, press the key . To select the melody and exit the pro-
gramming, press the key . To select the melody and continue with programming, press the
key .
43,5
45
7,5 57
70
106
A
M2M1
+
Page 4 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 4 - Manual FA01395-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructionsPage 4 - Manual FA01395-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
Programming the melody associated with the doorbell (2 acoustic signals).
Per questo tipo di programmazione e proceed as previously described for “Programming the
melody associated to the call from the entry panel”.
Programming the number of call rings (3 acoustic signals).
Press the key the number of times equal to the rings selected for the call (1 to 6 rings) .
After the key is pressed the last time, the call selected for the selected number of rings will be
will be reproduced.
To save the new settings, press the button otherwise, press the door lock release button
to enter the entry panel call melody programming procedure again.
VAS/101
Installation
The power supplier must ALWAYS be installed horizontally.
The device can be installed on a DIN rail (EN 50022) in an appropriate electric panel.
For the overall dimensions see fi gure .
NOTE. Proper ventilation is required if the power supplier is installed in a metal container.
Terminal board M1
~Mains
~
Terminal board M2
+Power supply 18 VDC (*)
(*) The appliance is electronically protected
against overloads and short circuits.
Technical features
T
y
pe VAS-101
Power supply 230 VAC 50÷60 Hz
Input current Imax =200 mAAC
AC
Dissipated power 10 W max
Nominal power supply 18 VDC 1 A-0,5 A 1’/3’
(1–0,5А (18В пост. тока)
на 1-3 сек)
Dimensions 4 DIN
Storage temperature -25 °C + 70 °C
Operating temperature 0 °C +35 °C
IP Degree IP 30
PP
PP


PP
PP
PP
PP
Page 5 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 5 - Manual FA01395-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructionsPage 5 - Manual FA01395-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
LVC/01
Wall mounting
With the allen wrench unscrew the blocking screws and remove
the plate (fi gure ).
Fix the given plugs and screw the entry panel (fi gure ) at the
desired height considering the position of the lens of the camera
(fi gure ).
Run the hose with the system conductors as shown in fi gure .
Extract the plastic terminal cover and wire the connections (fi gure
).
Once all the connections have been made, re-insert the terminal
covers.
For the installation of the accessories refer to the chapter “But-
ton module installation”.
Perform the programming and adjustment operations of the entry
panel as described to the chapter “Programming. Install the
front plate (fi gure ).
Recessed installation
Install the recessed box at the desired height considering the
position of the lens of the camera (fi gure ) but in advance, run
the hose with the system conductors through one of the breaking
points (fi gure point ). During installation of the recessed
box it is possible to avoid any deformation by using the provided
spacer (fi gure point ).
With the allen wrench unscrew the blocking screws and remove
the entry panel plate (fi gure ).
A
B
DPS LTP
LSI LCI
Page 6 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 6 - Manual FA01395-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructionsPage 6 - Manual FA01395-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
Introduce the cable connections in the special hole (fi gure )
and fi x the entry panel on the frame as shown in fi gure ; ex-
tract the plastic terminal cover and wire the connections (fi gure
).
Once the connections have been made and re-insert the terminal
covers. For the installation of the accessories refer to the chapter
Button module installation”.
Perform the programming and adjustment operations of the entry
panel as described to the chapter “Programming”.
Install the front plate (fi gure ).
Accessories
- DPS single button ,
- LTP Wall roof ,
- Recessed box LSI ,
- Recessed frame LCI .
1
2
M1
BOUT
M2
SW3
PROG
PROG
M2M1
+
9/6
B
B
NO
C
+
Page 7 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 7 - Manual FA01395-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructionsPage 7 - Manual FA01395-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
Button module installation
Insert the button module as highlighted in fi gure paying spe-
cial attention to the top to bottom orientation (fi gure ).
Remove the glass and write the user names as shown in fi gure
, paying special attention to the orientation of the glass (fi gure
).
Personalized labels: Dimensions
53x13x0,3 mm
53x33x0,3 mm
Terminal function
M1
BOUT
M2
SW3
PROG RESET
PROG
M2
SW3
PROG
PROG
>3
>3’’
<6’
<6’
M1
BOUT
SW3
PROG RESET
PROG
M2
ROG P
PROG
Page 8 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 8 - Manual FA01395-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructionsPage 8 - Manual FA01395-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
Terminal board M1
BOUT Riser
+
Power supply 16-18 VDC
Terminal board M2
Earth
Door lock release button (NA)
Solenoid lock
12 V 1 A max
Technical features
T
y
pe LVC/01
Entr
y
panel
Power supply 16-18 VDC/ 16–18
Absorption 250 mA (100 mA stand-by)
Dimensions 99x207x30 mm
Storage temperature -25 °C +70 °C
Operating temperature -15 °C +50 °C
IP Degree IP 54
Camera
Standard video PAL/NTSC
Resolution 680x512 pixel
Minimum lighting 1 LUX
LED functions and adjustments
loudspeaker audio
microphone audio
Solenoid lock 1-10 s. (default 1 s)
LED symbology
O
On
Slow fl ashing
Quick fl ashing
Programming
Initial programming
Entering Programming Mode. Press the PROG a key for at least
3 seconds and then release it (within 6 seconds), as soon as
the LED PROG lights up and the key back lighting fl ashes as
illustrated in fi gure .
Failure of the PROG LED to light up, indicates a malfunction.
Check the connections and re-access the programming mode.
M1
PROG
M1
PROG
M1
BOUT SW3
PROG RESET
PROG
beep
beep
M1
BOUT
M2
SW3
PROG RESET
PROG
M2
SW3
PROG
PROG
<1
<1’’
Page 9 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 9 - Manual FA01395-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructionsPage 9 - Manual FA01395-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
Programming the call keys. Lift the receiver (if present) of the
extension that you want to programme e then press the door lock
release and AUX2 buttons.
On the entry panel, press the call key to associate with the inter-
nal extension : an acoustic signal will confi rm that the setting
was stored.
Hang up the receiver again, if necessary and continue, re-
peating the same operations for the other extensions.
Programming of the Key Type. Press the fi rst key of the entry
panel in the position indicated /A until the backlighting LED
stops fl ashing and remains lit.
Exiting programming.
Briefl y press the PROG key : the PROG LED o .
NOTE. If no action is performed, the procedure will automatically
end after 30 minutes.
M1 M2
SW3
PROG RESET
PROG
M2
SW3
PROG
PROG
>3
>3’’
<6’
<6’
M1
BOUT SW3
PROG RESET
PROG
M2
ROG P
PROG
beep
beep
Page 10 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 10 - Manual FA01395-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructionsPage 10 - Manual FA01395-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
Reprogramming procedure
Entering Programming Mode. Press the PROG a key for at
least 3 seconds and then release it (within 6 seconds) as soon
as the LED PROG light fl ashes and the key back lighting lights up
as illustrated in fi gure . Failure of the PROG LED to light up,
indicates a malfunction. Check the connections and re-access
the programming mode.
Programming the call keys. Lift the receiver (if present) of the
extension that you want to programme then press the door
lock release and AUX2 buttons.
On the entry panel, press the call key to be associated with the
internal extension : an acoustic signal will confi rm that the set-
ting was stored. Hang up the receiver again, if necessary and
continue, repeating the same operations for the other extensions.
M1
BOUT
M2
SW3
PROG RESET
PROG
M2
SW3
PROG
PROG
<1
<1’’
>3
>3’’
<6’
<6’
M1
BOUT
SW3
PROG RESET
PROG
M2
ROG
PROG
M1
BOUT SW3
PROG RESET
PROG
M2
ROG P
PROG
M1
BOUT
PROG
M1
BOUT
PROG
Page 11 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 11 - Manual FA01395-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructionsPage 11 - Manual FA01395-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
Exiting programming. Briefl y press the PROG key : the
PROG LED o .
NOTE. If no action is performed, the procedure will automatically
end after 30 minutes.
Programmingkey type. At the “Programming Call Buttons
stage, press the PROG h key for at least 3 seconds and then
release it (within 6 seconds), as soon as the LED PROG lights
up and the key back lighting fl ashes as illustrated in fi gure ,
entering “Programming Button Types/Combinations” as part
of the procedure.
Press the fi rst key of the entry panel in the position indicated
until the backlighting LED stops fl ashing and remains lit.
At the end, exit programming, briefl y press the PROG key : the
PROG LED will turn o . If no action is performed, the procedure
will end automatically after 30 minutes.
DISPOSAL - Do not litter the environment with packing material: make sure it is disposed of according to the regulations in force
in the country where the product is used.
When the equipment reaches the end of its life cycle, take measures to ensure it is not discarded in the environment.
The equipment must be disposed of in compliance with the regulations in force, recycling its component parts wherever possible.
Components that qualify as recyclable waste feature the relevant symbol and the material’s abbreviation.
CAME S.p.A.
Via Martiri Della Libertà, 15
31030 Dosson di Casier - Treviso - Italy
tel. (+39) 0422 4940 - fax. (+39) 0422 4941
Page 12 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 12 - Manual FA01395-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructionsPage 12 - Manual FA01395-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

CAME BPT AGATA VC-V Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI