CAME AGATAKIT/200-HPV Installation guide

Category
Security camera accessories
Type
Installation guide

CAME AGATAKIT/200-HPV is a video entry kit that allows you to see and speak to visitors at your door from inside your home. It includes a wall-mounted video terminal with a 3.5-inch LCD TFT display, an audio entry control panel, and a power supply. The video terminal can be connected to up to two entry panels and two internal extensions, and it supports both PAL and NTSC video standards. The audio entry control panel allows you to answer calls from the entry panel, unlock the door, and activate the stair light.

CAME AGATAKIT/200-HPV is a video entry kit that allows you to see and speak to visitors at your door from inside your home. It includes a wall-mounted video terminal with a 3.5-inch LCD TFT display, an audio entry control panel, and a power supply. The video terminal can be connected to up to two entry panels and two internal extensions, and it supports both PAL and NTSC video standards. The audio entry control panel allows you to answer calls from the entry panel, unlock the door, and activate the stair light.

VA/200
AGATA VC 200
AGATA V 200
TARGHA 200
INSTALLATION MANUAL
AGATAK200 VC03
AGATAK200 V03
EN
Engl
i
sh
FB00953-EN
VIDEO ENTRY KIT
1
2
ABCD
A
B
Page 2 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 2 - Manual FB00953-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructionsPage 2 - Manual FB00953-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
General Precautions
Read the instructions carefully before beginning the installa-
tion and carry out the actions as specifi ed by the manufacturer.
The installation, programming, commissioning and mainte-
nance of the product must be carried out only by qualifi ed tech-
nical personnel, correctly trained with regard to respecting the
regulations in force, including the implementation of accident
prevention measures.
Before carrying out any cleaning or maintenance operation,
disconnect the power supply.
The equipment must be destined only for the use for which
it was designed.
The manufacturer declines all liability for any damage as a
result of improper, incorrect or unreasonable use.
This product complies with the relevant directives in force.
Decommissioning and disposal. Dispose of the packaging
and the device at the end of its life cycle responsibly, in com-
pliance with the laws in force in the country where the product
is used. The recyclable components are marked with a symbol
and the material's ID marker.
THE DATA AND INFORMATION SHOWN IN THIS MANUAL ARE TO BE
CONSIDERED AS SUBJECT TO CHANGE AT ANY TIME AND WITHOUT
THE NEED FOR ANY ADVANCE WARNING. MEASUREMENTS, UNLESS
OTHERWISE INDICATED, ARE IN MILLIMETRES.
AGATA VC200 - AGATA V200
Wall-mounted installation
Remove the unit from the metallic support by sliding it after
pressing the plastic button .
Attach the wall bracket to the round recessed box Ø 60mm
A, the rectangular box 503 ( B and C), the rectangular box
506E 4, or the Ophera recessed box (PHI) using the provided
screws and observing the TOP indication.
To ensure greater stability to the mounting surface, secure box
with screws and anchors provided.
The recessed box must be fi tted at a suitable height in relation to
the user. Avoid excessive tightening of the screws.
Once the connections have been made, hook the video terminal
C
D
E
F
Page 3 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 3 - Manual FB00953-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructionsPage 3 - Manual FB00953-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
to the metal support . To release the unit from the metal
support, press the plastic hook and lift the terminal .
Technical features
Tipo AGATA VC200
AGATA V200
Power supply (VDC) 14 ÷ 17,5
Current consumption (mA) 95
Consumption in stand-by mode (mA) < 12
Single LED consumption (mA) 1
Bandwidth at -3dB (MHz) 5
Video input impedance (k) ≥ 22
Coaxial video input (Vpp) 1
Video input from phone pair (Vpp) ± 0,6
Storage temperature (°C) -25 ÷ +70
Operating temperature (°C) +5 ÷ +40
IP Rating IP30
Video standard PAL/NTSC
LCD TFT display (inches) 3,5
Function of terminals
Terminal Board M1
Agata V 200 - Agata VC 200
3Video signal Coaxial cable
4Video signal screen
If the video feed ends at this monitor then connect a 75Ω im-
pedance termination resistor (violet-green-black-gold) across
terminals 3 and 4.
3Positive video signal Phone pair
4Negative video signal
If the video feed ends at this monitor then connect a 56Ω im-
pedance termination resistor (green-blue-black-gold) across
terminals 3 and 5 and a second 56Ω resistor across terminals
4 and 5.
514÷17.5V monitor power supply
6+
7Call from entry panel input
Audio to monitor
Audio to entry panel
AUX: auxiliary services (24V 100 mA)
Doorbell input
43,5
45
7,5 57
210
106
A
B
64,5
210
145
2
1
3
A
B
C
Page 4 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 4 - Manual FB00953-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructionsPage 4 - Manual FB00953-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
VA/200
Installation
The power supplier must ALWAYS be installed horizontally.
The device can be installed on a DIN rail (EN 50022) in an ap-
propriate electric panel or it may be wall-mounted using the pro-
tective terminal covers.
For disassembly, proceed as shown in fi gure and .
For the overall dimensions see fi gure .
NOTE. Proper ventilation is required if the power supplier is
installed in a metal container.
Technical features
Type VA/200
Nominal voltage [V AC] 230
Rated power max [VA] 60
Dimensions [DIN] 12
Storage temperature [°C] -25 ÷ +70
Operating temperature [°C] 0 ÷ +35
IP Rating [IP] 30
Entry panel, internal extension and accessories power
supply
Nominal voltage [V DC] 17,5
Max continuous operating current (intermittent)
[A] 0,9 (1,5)
Audio entry control accessories power supply
Nominal voltage [V DC] 12
Max continuous operating current [A] 0,4
Solenoid door lock power supply
Nominal voltage [V DC] 12
Max intermittent operating current [A] 0,5
D
Page 5 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 5 - Manual FB00953-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructionsPage 5 - Manual FB00953-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
Features
Terminal boards A
~Mains
~
Terminal boards B
5
6
Power supply 17,5 VDC (*)
+ to entry panel
5– 12V supply voltage audio
21 + entry system accessories
8 Call common 1
8A Call common 2
22 Stair light actuator output (VLS/101)
11 Audio to monitor
12 Audio to entry panel
23 Auxiliary door lock release button
14 Entry panel activation
13 + Power supply 12 VDC (*)
16 to electrical door lock
Terminal boards C
5– Power supply 17,5 VDC
6+ to monitor and accessories
8 Audio to monitor
9 Audio to entry panel
Terminal boards D
Coaxial cable connection
3 Video signal
4 Video signal shield
7 Call no. 1
Coaxial cable connection
3 Video signal
4 Video signal shield
7 Call no. 1
(*) The appliance is electronically protected against overloads
and short circuits.
Adjustments
TV: activation time of the system (30÷90 s).
: solenoid door lock activation time (1÷15 s).
SW (Selection of second ring tone)
Doorbell Second additional entry
panel
Page 6 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 6 - Manual FB00953-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructionsPage 6 - Manual FB00953-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
OPERATING CHARACTERISTICS
System activation timer
The installation remains active for 30 s following a call at the entry panel. If the handset is lifted during this interval, the activation time
is increased by 30 s and may be extended to a maximum of 90 s. by adjusting potentiometer TV, fi gure , pag. 5.
If the system is activated by the entry panel button, located on the internal unit, the system activation time (when not interrupted by
another call) may be adjusted between 30 and 90 s using potentiometer TV in fi gure , pag. 5.
System deactivation
The installation is switched o by the system timer once the set time has elapsed, or on completion of the electrical door lock function.
Call note
The unit is equipped with two di erential call tone generators.
The fi rst generator (terminal 8, terminal board B) is activated each time a call is made at the entry panel which simultaneously causes
the system activation timers to switch on.
The second generator (terminal 8A, terminal board B, and jumper SW in fi gure , pag. 5, energised) activates without switching on
the system. This means that the second generator may be used as a landing call signal.
When jumper SW is de-energised, the activation of the second generator causes the system to switch on, and permits, if required, the
identifi cation of two call sources (2 entry panels).
The outputs of the two call generators can simultaneously control a maximum of 3 internal units.
Door lock release (12V 1A)
The supply voltage to the electrical door lock is limited to approximately 1 to 15 s (adjusted using the potentiometer in fi gure ,
pag. 5) also with continuous activation of the door lock release button on the internal unit.
If the door lock release is activated by an auxiliary button (connected to terminal 23), the electrical door lock is energised for the
duration of activation of the said button.
Conversation privacy
The unit powers audio and video conversation privacy when the monitors and handsets are installed in the same system.
Stair light control
The stair light command can be performed with the monitor on (button Aux1), using the unit-relay VLS/101 connected to terminal 22
of the VA/200.
Page 7 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 7 - Manual FB00953-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructionsPage 7 - Manual FB00953-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
TARGHA 200
COMPONENTS
HAV/200
HAVC/200
Audio-video module HAV/200-HA-
VC/200
HTS
Embedding box
Chassis
Cable guide joints
Spacer
Screws
HPV/1
Plate
Micro-contact
Lighting module
Cable-clamp plate
HBP
Surface housing
Hole plugs
Cable guide joint
Joint
Screws and anchors
KHPS
Button
Micro-contact
Button spring
Page 8 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 8 - Manual FB00953-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructionsPage 8 - Manual FB00953-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
ADDITIONAL PUSH-BUTTON PANEL
HPP/6
HPP/12D
Plate
Micro-contacts with common call
Lighting module
Cable-clamp plates
Hole plug
$
521 811 12 14
521
521 811 12 14
521
A
B
C
521 811 12 14
521
D E
Page 9 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 9 - Manual FB00953-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructionsPage 9 - Manual FB00953-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
Recessed installation
The embedding box HTS must be fi tted fl ush with the wall at an
appropriate height.
In the case of video entry panels, the height should be such as to
exploit the features of the camera to the full.
Fit the spacer into embedding boxes to avoid deformation .
Insert the audio-video module at the top, near to the top mould-
ing of the chassis . In those installations liable to be a ected
by the Larsen e ect, the microphone can be fi tted in a remote
position, is indicated in fi gure . Apply the micro-contact (bot-
tom right) in the relevant seat . Insert the lighting module in
the relevant seat .
Remove the two plugs protecting the threaded holes in the
embedding box and secure the chassis using the two screws
supplied .
Perform the wiring and secure the wires in place using the cable-
clamp plate .
An additional pushbutton can be installed on the front plate:
follow the instructions supplied with the actual button for its as-
sembly.
F
G
H I
J K
Page 10 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 10 - Manual FB00953-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructionsPage 10 - Manual FB00953-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
Wall mounting
Apply the two hole plugs at the base .
Fit the embedding box HBP (3-module or round Ø 65mm version)
ush with the wall at an appropriate height.
In the case of video entry panels, the height should be such as to
exploit the features of the camera to the full.
Fasten the base onto the wall using the screws and screw an-
chors supplied .
Insert the audio-video module at the top, near to the top moul-
ding of the base .
In those installations liable to be a ected by the Larsen e ect,
the microphone can be fi tted in a remote position, as indicated
in fi gure .
Apply the micro-contact (bottom right) in the relevant seat .
Insert the lighting module in the relevant seat .
Perform the wiring and secure the wires in place using the cable-
clamp plate . An additional pushbutton can be installed on the
front plate: follow the instructions supplied with the actual button
for its assembly.
Assembly of the button
The name card can be removed and fi lled in with the relevant
information by removing the card clip followed by the actual card
itself . Personalized name cards can be used up to a maximum
of 2 mm thick.
A
NO
M
L
P Q
Page 11 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 11 - Manual FB00953-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructionsPage 11 - Manual FB00953-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
Closure of the cover plate
In order to fi t the front plate, fi rst insert the upper part in the
top moulding and then, using a Allenkey s 2.5, tighten the lock
screw .
Side-by-side recessed installation
For horizontal or vertical combinations, remove the
hole plugs and insert the cable guide joints. Fit the spacer into
embedding boxes to avoid deformation .
S
R
VS
V+
V-
14
12
11
6
5
CT
TC
T
TC
C
SW1
HAV/200
HAVC/200
HAV/200
HAVC/200
T
Page 12 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 12 - Manual FB00953-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructionsPage 12 - Manual FB00953-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
Side-by-side wall installation
For horizontal combinations, insert the two hole plugs on the
outside, at the bottom inside the cable guide joint and top inside
the joint .
Fasten the bases to the wall using the screws and screw anchors
supplied .
Terminal function
Terminal boards
5–Supply voltage
6+14 ÷ 17,5 VDC
11 audio to receiver
12 audio from receiver
14 enabling
V – negative video signal (1)
V + positive video signal
V + video signal (2)
V S video signal shield
(1) Terminals for use when the video si-
gnal is transmitted via twisted pair.
(2) Terminals for use when the video
signal is transmitted via coaxial cable.
Adjustments
loudspeaker audio
microphone audio
SW1 (video transmission type)
The video signal via
twisted pair
The video signal via
coaxial cable
500 mm
170 mm 710 mm 170 mm
140 mm
530 mm
140 mm
h
500 mm
V
U
Page 13 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 13 - Manual FB00953-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructionsPage 13 - Manual FB00953-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
Orientation of the camera
CCD colour camera which can be rotated manually both hori-
zontally and vertically by ± 11° , with fi xed-focus lens (see
for the dimensions of the fi eld of view) and phonic group
(the microphone can be removed and fi tted in a remote position
where the installation features so require).
Technical features
Tipo HAV/200
HAVC/200
Power supply [V DC] 14-17,5
Absorption [mA] 250
Sensor CCD 1/4”
Video output composite 1 Vpp [] 75
Resolution [lines] 380
Lens fi xed-focus f 3,7 F 5 (pin-hole)
Storage temperature [°C] -25 +70
Operating temperature [°C] -15 +50
IP Rating [IP] 54
Standard video PAL
Resolution [pixel] 680x512
Minimum lighting [LUX] 5
Page 14 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 14 - Manual FB00953-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructionsPage 14 - Manual FB00953-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
Page 15 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 15 - Manual FB00953-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructionsPage 15 - Manual FB00953-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
CAME S.p.A.
Via Martiri Della Libertà, 15
31030 Dosson di Casier - Treviso - Italy
tel. (+39) 0422 4940 - fax. (+39) 0422 4941
Page 16 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 16 - Manual FB00953-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructionsPage 16 - Manual FB00953-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

CAME AGATAKIT/200-HPV Installation guide

Category
Security camera accessories
Type
Installation guide

CAME AGATAKIT/200-HPV is a video entry kit that allows you to see and speak to visitors at your door from inside your home. It includes a wall-mounted video terminal with a 3.5-inch LCD TFT display, an audio entry control panel, and a power supply. The video terminal can be connected to up to two entry panels and two internal extensions, and it supports both PAL and NTSC video standards. The audio entry control panel allows you to answer calls from the entry panel, unlock the door, and activate the stair light.

Ask a question and I''ll find the answer in the document