Thermo Fisher Scientific Pathatrix Listeria spp. Kit Linked to Selective Agar Plates User guide

Type
User guide
USER GUIDE
For testing of Food and Environmental samples only.
Pathatrix® Listeria spp. Kit (Individual Samples)
Linked to Selective Agar Plates
For use with the Pathatrix® Auto Instrument
Catalog Number APL50
Publication Number MAN0007093
Revision 31 August 2012
The information in this guide is subject to change without notice.
DISCLAIMER
LIFE TECHNOLOGIES CORPORATION AND/OR ITS AFFILIATE(S) DISCLAIM ALL WARRANTIES WITH RESPECT TO THIS DOCUMENT, EXPRESSED OR IMPLIED,
INCLUDING BUT NOT LIMITED TO THOSE OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR NON-INFRINGEMENT. TO THE EXTENT
ALLOWED BY LAW, IN NO EVENT SHALL LIFE TECHNOLOGIES AND/OR ITS AFFILIATE(S) BE LIABLE, WHETHER IN CONTRACT, TORT, WARRANTY, OR
UNDER ANY STATUTE OR ON ANY OTHER BASIS FOR SPECIAL, INCIDENTAL, INDIRECT, PUNITIVE, MULTIPLE OR CONSEQUENTIAL DAMAGES IN
CONNECTION WITH OR ARISING FROM THIS DOCUMENT, INCLUDING BUT NOT LIMITED TO THE USE THEREOF.
Limited Use Label License: Environmental testing, quality control/quality assurance testing, food and agricultural testing
The purchase of this product conveys to the purchaser the limited, non-transferable right to use the purchased amount of the product (a) to perform internal
research for the sole benefit of the purchaser; and (b) for environmental testing, quality control/quality assurance testing, food and agricultural testing,
including reporting results of purchaser's activities in environmental testing, quality control/quality assurance testing, food and agricultural testing for a fee
or other commercial consideration. No other right is hereby granted expressly, by implication, or by estoppel. This product is for environmental testing, quality
control/ quality assurance testing, food and agricultural testing and research purposes only.
The purchase of this product does not grant the purchaser any additional rights, including (without limitation) the right to transfer or resell the product in
any form or the right to use the product as a therapeutic agent or diagnostics test component, or to use the product to perform other tests on a contract or
fee per test basis for or on behalf of third parties. For information on obtaining additional rights, please contact outlicensi[email protected]om.
TRADEMARKS
The trademarks mentioned herein are the property of Life Technologies Corporation or their respective owners in the United States and other countries.
Stomacher is a registered trademark of Seward Limited, UK. Whirl-Pak is a registered trademark of Wheatherby/Nasco, Inc.
© 2012 Life Technologies Corporation. All rights reserved.
Contents
3
Pathatrix® Listeria spp. Kit (Individual Samples) Linked to Selective Agar Plates
Product Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
About the kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Kit contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Materials not included in the kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Methods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Workflow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Procedural guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Sample enrichment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Sample preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Samples and consumable loading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Sample unloading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Detection—direct plating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Test result interpretation and classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
APPENDIX A Specific Recommendations for
High-Background Microflora . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
APPENDIX B Background . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Product overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Description of target microorganisms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Sampling protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Kit sensitivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Operating conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
AOAC Performance Tested Methodssm Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
APPENDIX C Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Related materials from Life Technologies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
4Pathatrix® Listeria spp. Kit (Individual Samples) Linked to Selective Agar Plates
Contents
APPENDIX D Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Chemical safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Specific chemical handling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Biological hazard safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Documentation and Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Obtaining SDSs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Obtaining Certificates of Analysis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Obtaining support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Limited product warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
5
Pathatrix® Listeria spp. Kit (Individual Samples) Linked to Selective Agar Plates
Product Information
IMPORTANT! Beforeusingthisproduct,readandunderstandtheinformationin
AppendixD,“Safety”onpage21.
WARNING! ListeriamonocytogenesandotherListeriaspp.areBiosafetyLevel2(BSL2)
organisms.Pregnantwomenorimmunocompromisedindividuals,inparticular,
shouldunderstandthesevere,potentialrisksassociatedwithworkingwithListeria
monocytogenes.CaremustbetakenwhenhandlingsamplesthatmaycontainListeria
spp.Laboratorypersonnelmustbeadequatelytrainedtohandlepathogensbefore
beingpermittedtoanalyzesamplesforListeriaspp.Laboratorypersonnelmustwear
appropriateprotectiveequipment,whichincludesbutisnotlimitedto:protective
eyewear,faceshield,clothing/labcoat,andgloves.Wasteshouldbedisposedofin
compliancewithlocalandnationallegislationasappropriate.
About the kit
ThePathatrix®Listeriaspp.Kitprovidesasamplepreparationmethodforpresence/
absencetestingbasedonthedetectionofasfewas1–10cfu(colonyformingunits)/25g
offoodsample.
UsingthePathatrix®Listeriaspp.Kit(individualsamples)linkedtoselectiveagar
plates,presumptiveresultscanbeobtainedwithin42hours.Apresumptivepositive
isolateshouldbesubsequentlyconfirmedbytheuseofsubculture,aswellas
appropriatebiochemicalandserologicaltestsasrequired.
Onceconfirmed,theresultsarereportedas:
Listeriaspp.Detectedin25g(samplematrices)
Listeriaspp.Notdetectedin25g(samplematrices)
SeeAppendixBonpage18foradditionalbackgroundinformation.
6Pathatrix® Listeria spp. Kit (Individual Samples) Linked to Selective Agar Plates
Product Information
Kit contents
Kit contents
ThePathatrix®Listeriaspp.Kit(Cat.no.APL50)containsenoughconsumable
componentsandPathatrix®beadstoprocess50 samples.
IMPORTANT! NeverfreezethePathatrix®beads.Beadsthathavebeensubjectedto
freezingtemperaturesmayberenderedinactive.
Note: Partsmayshipseparatelydependingonconfigurationandstorageconditions.
Materials not included in the kit
Thefollowingtableincludesmaterialsandequipmentforusing(butnotincludedin)
thePathatrix®consumableskits.Unlessotherwiseindicated,manyofthelisteditems
areavailablefrommajorlaboratorysuppliers(MLS).
Item Quantity or
volume Storage
Pre-sterilized Sample and Elution
Vessel Packs
50 each Room temperature
Pre-sterilized Capture Phase Packs 50 each Room temperature
Pre-sterilized Flat Cap Lids 50 each Room temperature
Anti-Listeria spp. Antibody-Coated
Paramagnetic Beads
The beads have a shelf life of 12 months and are labeled with an expiration date accordingly.
2.5 mL (50 tests) 5±3°C
Equipment, consumables, and reagents
Item Source
Equipment
Incubator, 37 ±1°C MLS
Pathatrix® Auto Instrument Life Technologies Cat. no. PATHATRIXAUTO
Consumables
Optional for environmental samples:
Swabs or sponges MLS
7
Pathatrix® Listeria spp. Kit (Individual Samples) Linked to Selective Agar Plates
Product Information
Materials not included in the kit
Sterile bags for enrichment (Whirl-Pak® or
Stomacher® bag, or equivalent)
Nasco # B01196WA, Seward product code
BA6041, or equivalent
Optional for high-particulate or high-fat-
content samples:
Sterile filter bags for enrichment (Whirl-
Pak® or Stomacher® bag, or equivalent)
or
•Pathatrix
® Foam filters
•Pathatrix
® 5-Pool Kit—Straws (254 mm)
and Syringes (10 mL)
Nasco # B01348WA, Seward product
code BA6041/STR, or equivalent
or
Life Technologies Cat. no. PFF
Life Technologies Cat. no. POOL510MLN
Sterile, disposable 10-µL loops MLS
Media
See page 10 and Appendix B on page 18 for recommendations about enrichment media
choice. Media is supplied by several manufacturers [e.g., Oxoid, BD, Difco, and Merck] in a
dehydrated form and should be prepared according to the manufacturer's instructions.
Half Fraser broth
Half Fraser broth supplement
Oxoid product code CM0895
Oxoid product code SR0166E
Alternative for environmental samples:
Buffered Listeria enrichment broth (BLEB)
BLEB supplement
Oxoid product code CM0897
Oxoid product code SR0141E
For optional secondary enrichment:
MOPS-BLEB Oxoid product code CM1071
Selective agar
PALCAM agar base
PALCAM selective supplement
Oxoid product code CM0877
Oxoid product code SR0150
Listeria selective agar (Oxford formulation)
Listeria selective supplement (Oxford
formulation)
Modified Listeria selective supplement
(Oxford formulation)
Oxoid product code CM0856
Oxoid product code SR0140
Oxoid product code SR0206
Alternative chromogenic agar:
Brilliance Listeria agar base
Brilliance Listeria selective supplement
Oxoid product code CM1080
Oxoid product code SR0227
Reagents
PBS, 10X, pH 7.4 Life Technologies Cat. no. AM9624 or
AM9625
Equipment, consumables, and reagents
Item Source
8Pathatrix® Listeria spp. Kit (Individual Samples) Linked to Selective Agar Plates
Product Information
Materials not included in the kit
9
Pathatrix® Listeria spp. Kit (Individual Samples) Linked to Selective Agar Plates
Methods
Workflow
Procedural guidelines
•Useaseptictechniqueandgoodlaboratorypracticesatalltimes.
•Afacemaskshouldbewornwhenweighingoutpowders.
• Caremustbetakenwhenboilingagarpriortoautoclaving,andheatresistant
glovesshouldbewornwhenhandlinghotflasksofliquid.
• Takecarewhenhandlingplatesortubesthatcontainmicroorganisms.
•Avoid
generatingaerosols,aspathogenicorganismsmaybepresent.
•Usedorunusedreagents,usedmedia,sampleenrichments,aswellasother
contaminateddisposablematerialsshouldbedisposedoffollowingprocedures
forinfectiousorpotentiallyinfectiousproducts.
•Sampleenrichmentsmightbecontaminatedwithpathogenicorganisms
infectioustohumans,soallwastemustbetreatedasbiohazardousandhandled
anddisposedusingsafelaboratorypractices,inaccordanceandcompliancewith
allappropriateregulations.
Sample enrichment (page 10)
T
Sample preparation (page 11)
T
Samples and consumable loading (page 12)
T
Sample unloading (page 15)
T
Detection—direct plating (page 15)
T
Test result interpretation and classification (page 16)
10 Pathatrix® Listeria spp. Kit (Individual Samples) Linked to Selective Agar Plates
Methods
Sample enrichment
Sample enrichment
Note: Certainfoodtypesandswabs/sponges,whichmayhaveveryhighbackground
flora,canbenefitfromanalternativeenrichmentstrategyincorporatingasecond
enrichmentinMOPSBLEB.(seeAppendixA,“SpecificRecommendationsforHigh
BackgroundMicroflora”onpage17).
1. Foodsamples
Preparea1in10dilutionofthefoodsampleinprewarmed(37±1°C)HalfFraser
broth(OxoidProductCodeCM0895)withsupplement(OxoidProductCode
SR0166E)inasterilebag.
Note: Forexample,add25goffoodsampleto225mLofprewarmedenrichment
media.
Environmentalcontactswabs
a. Prepareswabsforenrichment.Swabanarea10cmx10cmhasbeen
completedwiththerehydrated,prewettedswab,transfertheswabtoa
sterilebag.
b. Add50mLofprewarmed(37±1°C)appropriatelysupplementedHalf
Fraserbroth(OxoidCM0895withsupplementSR0166Eorequivalent,
e.g., BLEB).
2. Homogenizethesamplebyhandmixingfor10–15seconds.Massagethesample
betweenthefingerstodisperseanylargeclumpsofmaterial(NarangandCray,
2006).
3. IncubateALLsamplesat37 ±1°Cforaminimumof24 hours.
Note: Werecommendthatthesesubsamplesforanalysisareprocessed
immediatelyor,ifstorageisrequired,thatthesamplesarerefrigeratedat5±3°C.
Samplesshouldberewarmedto37±1°CpriortoanalysisonthePathatrix®Auto
Instrument.Theremainingenrichedsampleshouldbestoredat5±3°Cforupto
32 hoursuntiltheresultsofthepooledsamplehavebeendetermined.
11
Pathatrix® Listeria spp. Kit (Individual Samples) Linked to Selective Agar Plates
Methods
Sample preparation
Sample preparation
1. RemovetheSampleandElutionVesselsfromtheconsumablekitpackagingand
placeintotheTubeRack(alsoknownastheSampleVesselHolder).
2. Partiallyremovethelidsfrombothvessels,makinglargeenoughopeningsto
allowthesampleandwashbuffertobedispensedintothevessels.
3. Foodsamples
Preparea50mLsampleintheSampleVesselbytransferringa50mLaliquot
fromtheenrichedsample.
Swabsamples
Preparea10mLsampleintheSampleVesselbytransferringa10mLaliquot
fromtheenrichedsample.
Note: Ifthesamplesarehighlyparticulateand/orcontainahighfatcontent,the
useoftheFiltaFoamsystem(FoamFilters,Cat.no.PFF)withpoolingsyringes
andstraws(Cat.no.POOL510MLN)isrecommended.Alternatively,Seward
plainsterilebagswithinternalstrainersmaybeused(SewardProduct
Code BA6041/STRorequivalent).
4. Storetheindividualenrichedsamplesat5±3°Cforpotentialreanalysisuntilthe
testresultisconfirmed.
Note: Donotstoreformorethan32hours.Ifrefrigeratedafterenrichment,
samplesshouldberewarmedto37 ±1°Cpriortoremovalofaliquotsforanalysis.
12 Pathatrix® Listeria spp. Kit (Individual Samples) Linked to Selective Agar Plates
Methods
Samples and consumable loading
Samples and consumable loading
1. AddPBS(Cat.no.AM9624,dilutedto1X)tothefilllineoftheElutionVessel
(about35mLof1XPBS).
2. PlacethelidsontotheSampleandElutionVesselsmakingsurethatthevessels
aresealedallthewayaround.
3. Ensurethebeadsarefullyresuspendedbyagitatingthebeadvial(e.g.,vortexing
beadvialorinversionofsealedvial)andadd50μLofthebeadsuspension(beads
fromCat. no.APL50)intothespoutonthelidoftheSampleVessel.
4. Removetheplastickitfromthebagandorientatewiththevalveplungerpointing
left.ConnectthevalvefirmlytothelidsoftheSampleandElutionVessels.
Elution Vessel
Sterile 1X PBS (35 mL)
Sample Vessel Holder
(ATUBEHOLD)
Sample Vessel Spout
Sample Vessel
Capture Phase
Valve Plunger
13
Pathatrix® Listeria spp. Kit (Individual Samples) Linked to Selective Agar Plates
Methods
Samples and consumable loading
5. Holdingbothvessels,lifttheassembledvesselsandattachedkitoutoftherack
(alsoknownastheSampleVesselHolder).
6. PlacethevesselsintotheCartridge,pushingtheminfirmlyfromthebottom
upwards.
7. Next,firmlypushtherestofthekitintotheCartridge,startingwiththevalve
followedbythephaseandfinallythesyringe.
8. Pushthemagnetslideracrossintothelockingpositionandpressthemagnet
releasebuttononthesideoftheCartridgetoensurethekitispositionedcorrectly
andthemagnetswillmoveawayfromthephasefreely.
9. Resetthemagnetsintothelockingposition.
Syringe
Magnet Release Button
Valve Plunger
Phase
Sample Vessel
Elution Vessel
Cartridge Holder
(ACARTHOLD)
Sliding Magnet
Holder
14 Pathatrix® Listeria spp. Kit (Individual Samples) Linked to Selective Agar Plates
Methods
Samples and consumable loading
10. Foodsamples
Program1(P1)isusedforprocessing50mLfoodsamples,andP1istheDefault
modeonthePathatrix®AutoInstrument.
Swabsamples
Program2(P2)isusedforprocessing10mLswabsamplesandcanbeselected
bydepressingthescrollarrowkeyslocatedeithersideoftheLCDdisplay
simultaneouslyforapproximately5seconds,thenpressingtheleftarrowkey
oncetoselectP2.ThedisplaywillnowindicatethatP2hasbeenselectedby
showingPATHATRIXP2SELECTED.”
Note: ToreturntothedefaultP1runsettingforprocessingfoodsamples,again
pressbotharrowkeysfor5seconds,thenpresstheRIGHTarrowkeytoselectP1.
ThedisplaywillthenreturntothestandardPATHATRIXscreenasnormal.
11. InserttheCartridgeintothePathatrix®AutoInstrumentuntilinthelocking
position.
12. PresstheRUNbutton(i.e.,thenumberedbutton)abovetheappropriatecartridge.
TheLEDabovetheCartridgewillturngreenindicatingtherunhasbegun(P1,
approximately14minutes;P2,approximately25minutes).
†Program(P2)isusedtoprocess10mLenvironmentalsamplesandisnotAOACvalidated.
IfanAOACvalidatedprotocolisdesired,environmentalsamplesmaybeanalyzedusingP1.
15
Pathatrix® Listeria spp. Kit (Individual Samples) Linked to Selective Agar Plates
Methods
Sample unloading
Sample unloading
1. Attheendoftherun,theLEDwillflashredandgreenalternately.
2. PressthebuttonabovetheappropriateCartridgetoinitializethedrainingstep
(approximately1minute).
3. WhenthedrainingstepiscompleteandtheLEDisilluminatedred,removethe
Cartridgebypullingitout,awayfromtheinstrument.
4. RemovethesyringefromtheCartridgeandcarefullypullouttherestofthekit,
startingatthetopandworkingdownwards.WhenremovingtheSampleand
ElutionVesselsfromtheCartridge,holdfirmlybythevesselsthemselvesto
preventspillage.
5. PlacebothvesselsintheTubeRack(alsoknownastheSampleVesselHolderor
rack).
6. RemovethelidfromtheElutionVesseland,leavingtheElutionVesselinplaceon
therack,liftawaytherestoftheconsumable,includingtheSampleVessel,and
discard.
7. PlacetheElutionVesselintherackandcapwithaflatlid(providedinthe
consumablekit).Leaveintherackfor1minutetoallowcaptureofthebeads.
8. RemovealltheliquidfromtheElutionVessel,withoutremovingthevesselfrom
therack,takingcarenottodisturbthecapturedbeads.
9. RemovetheElutionVesselfromthevesselholder,add100μLofPBSintothe
ElutionVessel,andresuspendthePathatrix®beads.
10. AppropriatealiquotsofthePathatrix®beadsuspensioncanthenbeimmediately
analyzedusingthelaboratory’schosenpathogendetectionmethod.
Note: Thebeadsuspensionmayberetainedforlatertestingifnecessary.Thebeads
shouldbestoredAWAYfrommagnets(e.g.,Pathatrix®vesselholders)at5±3°Cforup
to24hours.
Detection—direct plating
Note: Werecommendstreakingthesampleouttogenerateindividualcolonies,as
opposedtospreadplating.
1. PipetteallofthePathatrix®beadsuspensionontotheedgeofwelldried
PALCAMandListeriaOxford,orequivalent,agarplates;e.g.,Chromogenic
Listeriaagar(ALOA).
2. Usingasterile10‐μLinoculationloop,streakfromthispooltogenerateisolated
colonies.
3. Allowtheplatestodryforapproximately10minutestheninvertandincubateat
37±1°Cfor18–48hours,asappropriate(24–48hourswasusedintheAOACRI
validationstudy).
16 Pathatrix® Listeria spp. Kit (Individual Samples) Linked to Selective Agar Plates
Methods
Test result interpretation and classification
Apresumptivepositiveresultisdefinedastheisolationoftypical,suspicious,or
atypicalListeriaspp.coloniesontheagarplatesused.Apresumptivepositiveisolate
shouldbesubsequentlyconfirmedbytheuseofsubculture,appropriatebiochemical
andserologicaltestsasrequired.
Test result interpretation and classification
ThePathatrix®Listeriaspp.Kitisdesignedasasamplepreparationmethodfor
presence/absencedetectionofListeriaspp.infoodmatrices
UsingthePathatrix®Listeriaspp.Kit(IndividualSamples)LinkedtoSelectiveAgar
Plates,presumptiveresultscanbeobtained,priortoconfirmation,within42hours.
Onceconfirmed,theresultsarereportedas:
Listeriaspp.Detectedin25g(samplematrices)
Listeriaspp.Notdetectedin25g(samplematrices)
A
17
Pathatrix® Listeria spp. Kit (Individual Samples) Linked to Selective Agar Plates
Specific Recommendations for
High-Background Microflora
Forcertainfoodgroupsorenvironmentalswabs,particularlywherehighlevelsof
backgroundmicrofloraarepresent,theListeriaspp.assayresultscanbeenhancedby
theuseofasecondaryMOPSBLEBbrothafterenrichmentinHalfFraser.Thelevelof
backgroundcontaminationontheagarplatescanbereducedbythismethod.
Examplesoffoodgroupsthatbenefitfromtheuseofthisapproachare:
•Rawmeat
•Rawshellfish
•Freshfinfish
•Rawvegetables
•Leafyproduce
• Salads
•Fruits
•CertainreadymealsandReadytoeat(RTE)productswithhighlevelsof
backgroundmicroflora
• Contactswabsfromhighlycontaminatedareas
B
18 Pathatrix® Listeria spp. Kit (Individual Samples) Linked to Selective Agar Plates
Background
Product overview
Description of
target
microorganisms
ThegenusListeriaiscomposedofsixspecies;L.monocytogenes,L.innocua,L. welshimeri,
L.seeligeri,L.ivanovii,L.grayiandtworecentlydiscoverednewspecies,giventhe
provisionalnamesL.marthiiandL.rocourti.L. monocytogenesisofclinicalrelevancefor
humansbecauseitisthecausativeagentforListeriosis.Listeria monocytogenesposesa
severerisktopregnantwomen,potentiallycausingspontaneousabortionorstillbirth.
Normally,L.monocytogenesistransferredtohumansthroughrawmilk,softripened
cheeses,rawvegetables,poultry,rawmeats,andraworsmokedfish.L.monocytogenes
growsattemperaturesaslowas3°C,allowingittomultiplyinrefrigeratedfoods.
Audience ThePathatrix®Listeriaspp.Kitisforprofessionaluseonlyandisintendedforuseby
qualifiedusersinterestedindeterminingthepresence/absenceofListeriaspp.infood
samples.Usersmayinclude,butarenotlimitedto,foodproducers,foodprocessors,
foodmanufacturers,retailers,andmicrobiologytestinglaboratories.
Sampling protocol ThestandardfoodsamplesizeusedinthePathatrix®Autosystemis25goffood
dilutedwith225mLofenrichmentmedium.Werecommendthatsubsamplesfor
poolingareprocessedimmediatelyor,ifstorageisrequired,thatthesamplesare
refrigeratedat5±3°C.Samplesshouldberewarmedto37±1°Cpriortoanalysiswith
thePathatrix®Autosystem.Theremainingenrichedsampleshouldbestoredat5±3°C
forupto32hoursuntiltheresultsofthepooledsamplehavebeendetermined.
Kit sensitivity Thesamplepreparationprocedureallowsyoutodetectasfewas1–10cfufrom
25gramsoffoodsample.ThelimitationofthePathatrix®Listeriaspp.Kitisinthe
abilityofthetargettoreproduceintheenrichmentmedium,becapturedbythe
magnet,andsubsequentlybeisolatedonselectiveagarplates.
CAUTION! ThePathatrix®kithasbeenevaluatedonsoftcheese,cream,andcooked
chickenfoodmatrices.Giventhewidevarietyofproductsandmanufacturing
procedures,itisrecommendedthatyoucheckthatthecompositionofthematricesto
betesteddoesnotaffectthereliabilityoftheresults.
Anegativeresultdoesnotguaranteetheabsenceoftargetorganismintheoriginal
sampleandmaybeduetotheinabilityoftheorganismtoadequatelyreproduceto
requiredlevelsintheenrichmentmedium(withsubsequentoutgrowthonselective
agarplates)potentiallydueto,butnotlimitedto,competitivemicroflora,sublethal
injury,ormatrixinhibition.
19
Pathatrix® Listeria spp. Kit (Individual Samples) Linked to Selective Agar Plates
Appendix B Background
AOAC Performance Tested Methodssm Certification B
Operating
conditions
ThePathatrix®AutoInstrumentisforindooruseonlyandforaltitudesnotexceeding
2000m(6500ft)abovesealevel.
AOAC Performance Tested Methodssm Certification
ThePathatrix®Listeriaspp.KithasbeenvalidatedandcertifiedbytheAOACResearch
Institute(Licensenumber090201B)forthedetectionofListeriaspp.infoodmatrices,
includingsoftcheese,cream,andcookedchicken.Thetestoperatesinconjunction
withapooledPathatrix®workflow.Astandard25gfoodsampleishandmixedbriefly
with225mLofenrichmentmediumandincubatedforaminimumof24 hoursat
37±1°C.Afterincubation,a10‐to50mLaliquotofthesampleissubjectedtoa
15minutePathatrix®AutoInstrumentcapturecycle.
Themethodwasvalidatedforusewiththefollowingmatrices:
•25gofsoftcheese
•25gofcream
•25gofcookedchicken
Temperature and humidity requirements
Condition Acceptable range
Temperature 5 to 40°C
Humidity Maximum relative humidity 80% for
temperatures up to 31°C, decreasing to 50%
C
20 Pathatrix® Listeria spp. Kit (Individual Samples) Linked to Selective Agar Plates
Ordering Information
Related materials from Life Technologies
Equipment, consumables, and reagents
Item Cat. no.
Related consumable kits with associated beads
Pathatrix® 5-Pooling Listeria spp. Kit APL250P
Pathatrix® 10-Pooling Listeria spp. Kit APL500P
Pathatrix® DUAL (Listeria/Salmonella spp.) Kit APD50
Equipment
Pathatrix® Auto Instrument PATHATRIXAUTO
Cartridge Rack (optional for use with the Pathatrix® Auto Instrument;
holds 5 Cartridges)
ACARTRACK
Consumables
Foam filters PFF
5-Pool Kit—Straws (254 mm) and Syringes (10 mL) POOL510MLN
Reagents
PBS, 10X, pH 7.4 AM9624 or AM9625
Related PCR assay
MicroSEQ® Listeria spp. Detection Kit 4427410
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26

Thermo Fisher Scientific Pathatrix Listeria spp. Kit Linked to Selective Agar Plates User guide

Type
User guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI