- 154 HEATER KIT
This kit is designed for DoorKing 6050/6100, 6300, 9000, 9024 AC Powered 115 VAC Input power ONLY, 9050/9100, 9150,
1601/1602/1603 and 6550 model gate operators. For cold weather climates where temperatures routinely drop below 10°F (-12°C).
A built-in thermostat will automatically control the temperature inside operator housing. Find your specific operator on next 8 pages.
Wire run distances are shown for a single 6050 operator with heater. In bi-parting (dual) gate applications, reduce the distance by one-half.
Wire run distances are shown for a single 6100 operator with heater. In bi-parting (dual) gate applications, reduce the distance by one-half.
DoorKing Part Number
High Voltage AC Input Power for a Gate Operator with a Heater
DO NOT use the “high voltage wire size and distance limitations” table in the Installation/Owner’s manuals to determine the high voltage AC input
power wire size and distance limitations for the gate operator because of a much greater current draw when using the heater. Use the wire run
table to determine the wire size and distances for your chosen gate operator when a heater is installed.
If the high voltage AC input power wiring is greater than the maximum distance shown, it is recommended that a service feeder be installed.
When large gauge wire is used, a separate junction box must be installed for the operator connection. Wire run calculations are based on
NEC 310.15(B)(16) with a maximum voltage drop of 3%. These wire runs are a general guideline but these distances may vary.
Never run low voltage rated wire insulation in the same conduit as high voltage rated wire insulation. Keep them in separate conduits.
6100
6050
Wire Size / Max Distance in Feet
Operator
and
Heater
Amps
Model Horsepower Volts 12 AWG 10 AWG 8 AWG 6 AWG
1/2 HP
1/2 HP
8.7
8.7
115 100 150 250 400
115
150 250 400100
High voltage AC input wire size and distance limitations for a single gate operator with a heater.
6050 / 6100
Connect the heater power wires.
To secondary operator
heater if installed.
DANGER
HIGH VOLTAGE!
Power Connection
Neutral
Hot
115 VAC
Power Terminal
Note for Bi-Parting Dual Gate Operators:
Run two (AWG 16-600 volt insulation)
power wires from the primary operator
power terminal through the
interconnection cable conduit to power
the secondary operator’s heater. Do Not
wire secondary heater directly to the
secondary operator’s terminal or damage
will occur.
Hot
Neu
Mounting
Plate
Install on existing
threaded studs
Heater MUST be
installed on
mounting plate.
120 S. Glasgow Avenue
Inglewood, California 90301 U.S.A.
Heater Switch
ON - Normal setting. Automatically turns the
heater and fan ON when the temperature drops
below 40°F (4°C) inside the operator, and turns
the heater and fan OFF when the temperature
rises above 55°F (13°C) inside the operator.
OFF - Turns the heater and fan off.
ON
OFF
Copyright 2020 DoorKing
®
, Inc. All rights reserved.
DANGER
HOT!
Shut off the
AC input
power to
the
operator
from the
circuit
breaker.
Keep wires
away from the
heater vents.
1601-154
115 VAC Model
3.3 Amp
1
9210-165-G-11-20
6300
DoorKing Part Number
1601-154
120 S. Glasgow Avenue
Inglewood, California 90301 U.S.A.
Wire run distances are shown for a single 6300 operator with heater. In bi-parting (dual) gate applications, reduce the distance by one-half.
6300
Wire Size / Max Distance in Feet
Operator
and
Heater
Amps
Model Horsepower Volts 12 AWG 10 AWG 8 AWG 6 AWG
1/2 HP
1 HP
8.7115
115
150 250 400100
100 160 26013.0 60
High voltage AC input wire size and distance limitations for a single gate operator with a heater.
Mounting
Plate
DANGER
HOT!
Install on existing
threaded studs
Heater MUST be
installed on
mounting plate.
Connect the heater power wires.
DANGER
HIGH VOLTAGE!
Power Connection
Neutral
Hot
115 VAC
Power Terminal
Note for Bi-Parting Dual Gate Operators:
Run two (AWG 16-600 volt insulation)
power wires from the primary operator
power terminal through the
interconnection cable conduit to power
the secondary operator’s heater. Do Not
wire secondary heater directly to the
secondary operator’s terminal or damage
will occur.
Hot
Neu
Heater Switch
ON - Normal setting. Automatically turns the
heater and fan ON when the temperature drops
below 40°F (4°C) inside the operator, and turns
the heater and fan OFF when the temperature
rises above 55°F (13°C) inside the operator.
OFF - Turns the heater and fan off.
ON
OFF
Shut off the AC input
power to the operator
from the circuit breaker.
Keep wires
away from the
heater vents.
IMPORTANT: DO NOT install this heater kit if your gate operator has the optional high voltage kit installed on it.
To secondary operator
heater if installed.
2
9210-165-G-11-20
9000
DoorKing Part Number
1601-154
120 S. Glasgow Avenue
Inglewood, California 90301 U.S.A.
Note: Operator illustrated without
some components to better show
heater mounting location.
9000
Wire Size / Max Distance in Feet
Operator
and
Heater
Amps
Model Horsepower Volts 12 AWG 10 AWG 8 AWG 6 AWG
Wire run distances are shown for a single 9000 operator with heater. In bi-parting (dual) gate applications, reduce the distance by one-half.
1/2 HP
1 HP
8.7115
115
150 250 400100
100 160 26013.0 60
High voltage AC input wire size and distance limitations for a single gate operator with a heater.
ON - Normal setting. Automatically turns
the heater ON when the temperature
drops below 40°F (4°C) inside the
operator, and turns the heater OFF when
the temperature rises above 55°F (13°C)
inside the operator.
Heater Switch
ON
OFF
OFF
- Turns the heater off.
Connect the heater power wires in electronic box.
DANGER
HIGH VOLTAGE!
Power Connection
Neutral
Hot
115 VAC
Power Terminal
Note for Bi-Parting Dual Gate Operators:
Run two (AWG 16-600 volt insulation)
power wires from the primary operator
power terminal through the
interconnection cable conduit to power
the secondary operator’s heater. Do Not
wire secondary heater directly to the
secondary operator’s terminal or damage
will occur.
Hot
Neu
Shut off the AC input
power to the operator
from the circuit breaker.
Back of Electronic Box
Install on existing
threaded studs
ON
OFF
DANGER
HOT!
Mounting
Plate
Heater MUST be
installed on
mounting plate.
Keep wires
away from the
heater vents.
Power
Wires
IMPORTANT: DO NOT install this heater kit if your gate operator has the optional high voltage kit installed on it.
To secondary operator heater if installed.
ON
OFF
3
9210-165-G-11-20
Back of Electronic Box
9024 AC Powered 115 VAC ONLY
DoorKing Part Number
1601-154
120 S. Glasgow Avenue
Inglewood, California 90301 U.S.A.
Note: Operator illustrated without
some components to better show
heater mounting location.
ON - Normal setting. Automatically turns
the heater ON when the temperature
drops below 40°F (4°C) inside the
operator, and turns the heater OFF when
the temperature rises above 55°F (13°C)
inside the operator.
Heater Switch
ON
OFF
OFF
- Turns the heater off.
Connect the heater power wires in electronic box.
DANGER
HIGH VOLTAGE!
Power Connection
Shut off the AC input
power to the operator
from the circuit breaker.
ON
OFF
DANGER
HOT!
Mounting
Plate
Heater MUST be
installed on
mounting plate.
Keep wires
away from the
heater vents.
Install on existing
threaded studs
9024
AC
Powered
Wire Size / Max Distance in Feet
Operator
and
Heater
Amps
Model Horsepower Volts 12 AWG 10 AWG 8 AWG 6 AWG
High voltage AC input wire size and distance limitations for a single gate operator with a heater.
In bi-parting (dual) gate applications, high voltage AC power is required for EACH 9024 AC Powered 115 VAC operator with heater.
Quadra Drive
DC Motor
5.1115
ONLY
170 270 430 680
115 VAC
Hot
Neu
Power
Wires
4
9210-165-G-11-20
9050 / 9100
DoorKing Part Number
1601-154
120 S. Glasgow Avenue
Inglewood, California 90301 U.S.A.
ON - Normal setting. Automatically turns
the heater ON when the temperature
drops below 40°F (4°C) inside the
operator, and turns the heater OFF when
the temperature rises above 55°F (13°C)
inside the operator.
Heater Switch
Heater Location
ON
OFF
OFF
- Turns the heater off.
DANGER
HIGH VOLTAGE!
Shut off the AC input
power to the operator
from the circuit breaker.
Heater MUST be
installed on
mounting plate.
115 VAC
Hot
Neu
ON
O
FF
Heater
Note: Operators illustrated without
some components to better show
heater mounting location.
In bi-parting (dual) gate applications, AC input power is required for EACH 9100 operator with heater.
In bi-parting (dual) gate applications, high voltage AC power is required for EACH 9050 operator with heater.
9100
9050
Wire Size / Max Distance in Feet
Operator
and
Heater
Amps
Model Horsepower Volts 12 AWG 10 AWG 8 AWG 6 AWG
1/2 HP
8.7115 100 150 250 400
1/2 HP
8.7115 150 250 400100
High voltage AC input wire size and distance limitations for a single gate operator with a heater.
O
N
OFF
Mountin
g
Plate
DANGER
HOT!
Existing
Operator
Threaded
Stud
Existing
Operator
Threaded
Stud
Connect the heater power wires in electronic box.
Power Connection
Keep wires
away from the
heater vents.
5
9210-165-G-11-20
9150
DoorKing Part Number
1601-154
120 S. Glasgow Avenue
Inglewood, California 90301 U.S.A.
ON - Normal setting. Automatically turns
the heater ON when the temperature
drops below 40°F (4°C) inside the
operator, and turns the heater OFF when
the temperature rises above 55°F (13°C)
inside the operator.
Heater Switch
Heater Location
ON
OFF
OFF
- Turns the heater off.
DANGER
HIGH VOLTAGE!
Shut off the AC input
power to the operator
from the circuit breaker.
Heater MUST be
installed on
mounting plate.
O
N
OFF
Mountin
g
Plate
DANGER
HOT!
Existing
Operator
Threaded
Stud
Existing
Operator
Threaded
Stud
Connect the heater power wires.
Power Connection
Keep wires
away from the
heater vents.
In bi-parting (dual) gate applications, high voltage AC power is required for EACH 9150 operator with heater.
9
150
Wire Size / Max Distance in Feet
Operator
and
Heater
Amps
Model Horsepower Volts 12 AWG 10 AWG 8 AWG 6 AWG
1/2 HP
1 HP
8.7115
115
150 250 400100
100 160 26013.0 60
High voltage AC input wire size and distance limitations for a single gate operator with a heater.
O
N
OF
F
Heater
9150 ONLY
115 VAC Output
Hot Hot
Neu
Note: Operators illustrated without
some components to better show
heater mounting location.
IMPORTANT: DO NOT install this heater kit if your gate operator has the optional high voltage kit installed on it.
6
9210-165-G-11-20
1601 / 1602 / 1603 Barrier Gate Operators
DoorKing Part Number
1601-154
120 S. Glasgow Avenue
Inglewood, California 90301 U.S.A.
High voltage AC input wire size and distance limitations for a single gate operator with a heater.
1/2 HP1601 / 1603
1602
1 HP
8.7115
115
150 250 400100
100 160 26013.0 60
Wire Size / Max Distance in Feet
Operator
and
Heater
Amps
Model Horsepower Volts 12 AWG 10 AWG 8 AWG 6 AWG
In bi-parting (dual) gate applications, high voltage AC power is required for EACH 1601 or 1602 operator with heater.
IMPORTANT: DO NOT install this heater kit if your gate operator has the optional high voltage kit installed on it.
Connect the heater power wires.
DANGER
HIGH VOLTAGE!
Use supplied wire stays and existing
wire restrainers to run wires.
Keep wires clear of all moving
parts and the heater vents.
Power Connection
Wire Stay
s
Existing Wire Restrainers
Install with
existing
carriage
bolts
OR
existing
threaded
studs
ON
OF
F
DANGER
HOT!
Mount
i
ng
Plate
Neutral
Hot
115 VAC
Power Terminal
HotNeu
Heater MUST be
mounted on
mounting plate.
ON - Normal setting. Automatically turns the heater and
fan ON when the temperature drops below 40°F (4°C)
inside the operator, and turns the heater and fan OFF
when the temperature rises above 55°F (13°C) inside the
operator.
OFF - Turns the heater/fan off.
Heater Switch
ON
OFF
Shut off the AC input
power to the operator
from the circuit breaker.
7
9210-165-G-11-20
6550
DoorKing Part Number
1601-154
120 S. Glasgow Avenue
Inglewood, California 90301
U.S.A.
Connect the heater power wires.
DANGER
HIGH VOLTAGE!
Heater Switch
Power Connection
Neutral
Hot
115 VAC
Power Terminal
Note for Bi-Parting Dual Gate Operators:
Run two (AWG 16-600 volt insulation)
power wires from the primary operator
power terminal through the
interconnection cable conduit to power
the secondary operator’s heater. Do Not
wire secondary heater directly to the
secondary operator’s terminal or damage
will occur.
ON - Normal setting. Automatically turns the
heater and fan ON when the temperature drops
below 40°F (4°C) inside the operator, and turns
the heater and fan OFF when the temperature
rises above 55°F (13°C) inside the operator.
OFF - Turns the heater and fan off.
ON
OFF
Hot
Neu
Use Existing 2 Bolts and Nuts
Run power wires
through chassis.
Power Wires
ON
O
F
F
DANGER
HOT!
Mounting
Plate
Shut off the AC input
power to the operator
from the circuit breaker.
1 HP
115 100 160 26013.0 60
Wire Size / Max Distance in Feet
Operator
and
Heater
Amps
Model Horsepower Volts 12 AWG 10 AWG 8 AWG 6 AWG
6550
Wire run distances are shown for a single 6550 operator with heater. In bi-parting (dual) gate applications, reduce the distance by one-half.
High voltage AC input wire size and distance limitations for a single gate operator with a heater.
Heater MUST be
installed on
mounting plate.
Keep wires
away from the
heater vents.
IMPORTANT: DO NOT install this heater kit if your gate operator has the optional high voltage kit installed on it.
To secondary operator
heater if installed.
O
N
O
F
F
8
9210-165-G-11-20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

DKS 1601-154 Heater / Fan Kit User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI