Grundfos Oxiperm Pro OCD-162 Service Instructions Manual

Type
Service Instructions Manual
Service instructions
Oxiperm
®
Pro
OCD-162
1 / 152
1. General safety regulations.............................................................................................................. 3
1.1 Purpose of this manual........................................................................................................................................3
1.2 Layout of this manual........................................................................................................................................... 3
1.3 Authorised service personnel ..............................................................................................................................4
1.4 Obligations of the operator ..................................................................................................................................4
1.5 Correct usage ......................................................................................................................................................4
1.6 Inappropriate usage............................................................................................................................................. 5
1.7 Safety and monitoring equipment........................................................................................................................5
1.8 Chemicals............................................................................................................................................................ 5
2. Product description......................................................................................................................... 7
2.1 Application examples...........................................................................................................................................7
2.2 Functional principle..............................................................................................................................................8
2.3 Components of the Oxiperm Pro ....................................................................................................................... 12
2.4 System peripheral devices and accessories...................................................................................................... 14
2.5 Power supply connections and electronic connections ..................................................................................... 16
2.6 Control and display elements ............................................................................................................................16
2.7 Operating modes ............................................................................................................................................... 19
2.8 Access codes.....................................................................................................................................................19
2.9 User menu structure ..........................................................................................................................................20
3. Transport and packaging.............................................................................................................. 25
3.1 Unpacking.......................................................................................................................................................... 25
3.2 Transport damages............................................................................................................................................ 25
4. Installation...................................................................................................................................... 26
4.1 Installation location ............................................................................................................................................26
4.2 Mounting the unit on the wall (OCD-162-5/-10)................................................................................................. 28
4.3 Mounting the unit on the floor (OCD-162-30/-60) ..............................................................................................29
4.4 Additional modules ............................................................................................................................................32
4.5 Installing the chemical containers and attaching the suction lances ................................................................. 32
4.6 Hydraulic connections........................................................................................................................................ 33
4.7 Connecting the electronic components.............................................................................................................. 36
4.8 Connecting the power supply cable................................................................................................................... 38
5. Commissioning.............................................................................................................................. 39
5.1 System configuration ......................................................................................................................................... 39
5.2 Operating software settings...............................................................................................................................40
5.3 Commissioning procedure................................................................................................................................. 44
5.4 Switching on the system – initial start-up........................................................................................................... 45
5.5 Basic setup ........................................................................................................................................................ 46
5.6 Setting the water flow meter (if applicable)........................................................................................................48
5.7 Selecting the measuring cell type and measured variables (if applicable) ........................................................ 50
5.8 Assigning measuring range(s) (if applicable)..................................................................................................... 52
5.9 Setting the output current to an external device (if applicable)..........................................................................55
5.10 Setting the ClO
2
controller (not applicable for group 3 applications) ................................................................. 56
5.11 Setting the output current to an external dosing pump (if continuous controller is selected)............................. 60
5.12 Setting the warning and alarm relay ..................................................................................................................61
5.13 Manual ventilation..............................................................................................................................................66
15.710373 V1.0
GB
95719551 1109
2 / 152
5.14 Setting the operating mode ............................................................................................................................... 68
5.15 Starting operation .............................................................................................................................................. 69
5.16 Interrupting operation ........................................................................................................................................ 71
5.17 Continuing operation after an interruption ......................................................................................................... 72
5.18 Monitoring the production and dosing process.................................................................................................. 73
5.19 Flushing............................................................................................................................................................. 81
5.20 Calibration ......................................................................................................................................................... 84
5.21 Responding to error messages ......................................................................................................................... 90
5.22 Testing the system ............................................................................................................................................ 90
5.23 Setting the user display language (if applicable)............................................................................................... 98
5.24 Saving the settings after commissioning ........................................................................................................... 98
5.25 Switching off the system.................................................................................................................................... 98
5.26 Completing the acceptance record.................................................................................................................... 98
6. Maintenance................................................................................................................................... 99
6.1 Viewing the maintenance interval.................................................................................................................... 100
6.2 Planning maintenance – obtaining maintenance kits ...................................................................................... 101
6.3 Maintaining the pumps .................................................................................................................................... 102
6.4 Maintaining the solenoid valve ........................................................................................................................ 105
6.5 Maintaining the multi-function valve ................................................................................................................ 107
6.6 Maintaining the reaction tank .......................................................................................................................... 111
6.7 Maintaining the volume compensation bag and activated carbon filter (OCD-162-5, -10).............................. 116
6.8 Maintaining the volume compensation bag and absorption filter (OCD-162-30, -60)...................................... 118
6.9 Confirming the Maintenance Release ............................................................................................................. 120
7. Servicing....................................................................................................................................... 121
7.1 Preparing for servicing .................................................................................................................................... 121
8. Fault finding ................................................................................................................................. 125
8.1 Faults with error message ............................................................................................................................... 125
8.2 Faults without error message at the OCD-162................................................................................................ 130
9. Dismantling and decommissioning the system........................................................................ 131
9.1 Planning and preparing for dismantling........................................................................................................... 131
9.2 Dismantling the hydraulic components............................................................................................................ 132
9.3 Dismantling the electrical components............................................................................................................ 133
9.4 Dismantling the system frame......................................................................................................................... 133
9.5 Packing the system for transport..................................................................................................................... 133
9.6 Final dismantling steps.................................................................................................................................... 133
9.7 Temporary storage of the dismantled system ................................................................................................. 133
9.8 Recommissioning after dismantling................................................................................................................. 134
10. Disposal........................................................................................................................................ 135
11. Technical data.............................................................................................................................. 135
11.1 Terminal connection plan ................................................................................................................................ 143
12. Spare parts list............................................................................................................................. 145
13. Applicable standards and directives ......................................................................................... 147
14. Operator’s accessories list......................................................................................................... 148
15. Photos........................................................................................................................................... 149
3 / 152
1. General safety regulations
1.1 Purpose of this manual
The Oxiperm Pro disinfection system from Grundfos Alldos reflects the best available technology and complies with
recognised safety regulations.
Compliance with applicable standards, guidelines and laws has been confirmed (declaration of conformity and list of
applicable standards and guidelines directives can be found in section 13. Applicable standards and directives).
Nevertheless, risks which are beyond the manufacturer's control may arise from the use of the system.
This manual is aimed at specialist personnel responsible for installation, commissioning, maintenance, servicing,
dismantling and (temporary) storage.
The purpose of this manual is as follows:
• to provide guidance on safe and correct installation.
• to provide guidance on safe and correct commissioning.
• to provide information about safe and correct maintenance and the correct installation of spare parts.
• to provide information about safe and correct fault finding and the correct replacement of components.
• to provide information about safe and correct dismantling, (temporary) storage and recommissioning.
• to warn against potential residual risks associated with the correct usage of the system and to identify means of
avoiding damage.
• to warn against obvious misuse or inappropriate usage of the system and to identify the need for due care when
using the system.
See the separate Installation and operating instructions for the Oxiperm Pro.
1.2 Layout of this manual
This manual contains the following standard risk and safety warnings relating to potential residual risks:
Information about potential residual risks can be found:
• on warning signs located at the installation site
• at the beginning of each section in this manual
• immediately before steps associated with a residual risk.
Warning
If these safety instructions are not observed, it may result in personal injury!
Caution
If these safety instructions are not observed, it may result in malfunction or damage to the
equipment!
Note
Notes or instructions that make the job easier and ensure safe operation.
4 / 152
1.3 Authorised service personnel
Only authorised service personnel trained by Grundfos Alldos are permitted to undertake installation, commissioning,
maintenance, servicing, dismantling and (temporary) storage of the system. Appropriate technical expertise and
familiarity with the principles of measurement and control technology are assumed.
1.3.1 Obligations of the service personnel
Service personnel are required to do the following:
• Read this manual thoroughly before commencing installation, commissioning, maintenance, service, dismantling or
(temporary) storage of the Oxiperm Pro disinfection system.
• Obtain instruction from specialist personnel of Grundfos Alldos on all service work relating to the system.
• Observe the recognised health and safety and accident prevention regulations.
See section 1.4 Obligations of the operator.
• Wear protective clothing when working with the system and with chemicals.
See section 1.3.3 Protective clothing.
• Keep secret the user and service codes for the operating software.
1.3.2 Work station for service personnel
The Oxiperm Pro disinfection system is electronically controlled. Users and service personnel operate the system via a
display with control and display elements. See fig. 17.
1.3.3 Protective clothing
Service personnel are obliged to wear protective clothing in accordance with national safety regulations
(Germany: GUV-V D5 Accident prevention regulations, "Chlorination of water", January 1997) when working with the
system and with the chemicals. The protective clothing is supplied by the operator and stored in a dry place in the
installation room.
1.4 Obligations of the operator
Owners of the building and/or operators of the Oxiperm Pro disinfection system are required to:
• Consider this manual to be part of the product and ensure that it is kept clearly accessible in the immediate vicinity
of the system for the entire service life of the system.
• Provide the installation requirements specified by the manufacturer (necessary water connections and fittings,
environmental conditions, electrical connections, protective pipe for dosing line, audible or visual warning system
for alarms. See section 4.1 Installation location.
• Have water lines and fittings inspected, maintained and serviced on a regular basis.
• Obtain official approval, if necessary, to store the chemicals.
• Instruct users in the operation of the system.
• Attach the labels supplied by the manufacturer at the installation site so that they are clearly visible.
• Disclose the user code for the operating software only to appropriately trained users.
• Ensure compliance with accident prevention regulations at the installation site (Germany: GUV-V D5 Accident
prevention regulations, "Chlorination of water", January 1997).
• Provide all users and service personnel with protective clothing in accordance with accident prevention regulations
(German GUV-V D5) (face mask, gloves, protective apron, breathing mask, if necessary).
• If the system is supplied without a dosing pump, provide an external dosing pump prior to installation, and allow
only authorised specialist personnel from Grundfos Alldos to connect it to the Oxiperm Pro disinfection system.
1.5 Correct usage
The purpose of the Oxiperm Pro disinfection system is to mix a diluted chlorine dioxide solution from 7.5 % sodium
chlorite and 9 % hydrochloric acid. In accordance with the conditions described in this manual, the chlorine dioxide
solution may be dosed continuously or discontinuously into the (drinking) water supply of a building, or it may be
introduced into a swimming pool, service water plant, wastewater plant or other industrial plant for the purposes of water
disinfection.
5 / 152
1.6 Inappropriate usage
Applications other than those listed in section 1.5 Correct usage are considered not to be in accordance with the
intended use and are not permitted. The manufacturer, Grundfos Alldos, accepts no liability for any damage resulting
from incorrect use.
The system comprises state-of-the-art components and has undergone safety-related testing.
1.7 Safety and monitoring equipment
The Oxiperm Pro disinfection system is fitted with the following safety and monitoring equipment:
• cover on the system frame
• two collecting trays for the two chemical containers (accessories)
• safety/multi-function valve at the dosing pump (optional)
• solenoid valve at the dilution water inlet
• volume compensation bag and activated carbon filter for ClO
2
gas that escapes from the reaction tank
• alarm functions in the control system.
1.8 Chemicals
1.8.1 Chlorine dioxide concentration
In the reaction tank of the Oxiperm Pro disinfection system, diluted sodium chlorite and diluted hydrochloric acid are
mixed to create a chlorine dioxide concentration of 2 g per litre of water. The system doses the diluted chlorine dioxide
solution according to the disinfection requirement into the main line to be disinfected. According to the German drinking
water ordinance (TrinkwV 2001), the chlorine dioxide concentration in drinking water must not exceed a maximum of
0.4 mg per litre of water.
The following safety instructions must be observed:
1.8.2 Storing chemicals
– Chemicals must be stored in the appropriately marked original plastic containers.
– Do not store chemicals near grease, flammable substances, oils, oxidising substances, acids or salts.
– Empty and full containers must be kept closed, especially in areas where national regulations for the prevention
of accidents apply to storage (German GUV-V D5).
Warning
Unauthorised structural modifications to the system may result in serious damage to
equipment and personal injury. It is forbidden to dismantle, modify, change the structure of,
bridge, remove, bypass or disable components, including safety equipment.
Warning
Risk of explosion when using chemicals in too high a concentration.
Only use sodium chlorite in a diluted concentration of 7.5 % by weight in accordance with
EN 938.
Only use hydrochloric acid in a diluted concentration of 9.0 % by weight in accordance with
EN 938.
The safety data sheets from the chemicals supplier must be observed.
Warning
Risk of explosion and serious damage to equipment and personal injury as a result of
operating faults due to confusing the chemical containers or suction lances.
Do not confuse the containers.
Observe the red and blue markings on chemical pumps, suction lances and chemical
containers: Red = HCl, blue = NaClO
2
.
Warning
Risk of burns when skin and clothing come into contact with sodium chlorite and hydrochloric
acid.
Affected skin and clothing must be washed in water immediately.
Warning
Risk of irritation to eyes, respiratory system and skin if chlorine dioxide is inhaled.
When changing the chemical containers, wear protective clothing in accordance with
regulations for the prevention of accidents (Germany: GUV-V D5 Accident prevention
regulations, "Chlorination of water", January 1997).
6 / 152
1.8.3 Procedure in case of an emergency
The general safety regulations and regulations for the procedure in case of an emergency as specified in
EN 12671: 2007 (D) apply.
Actions in case of an emergency:
• Ventilate the installation location immediately.
• Wear protective clothing (safety goggles, gloves, respirator and/or self-contained breathing apparatus, protective
apron).
• Implement initial help measures:
– In case of contact with the eyes, rinse immediately with plenty of water for at least 15 minutes. Consult a doctor.
– In case of contact with the skin, wash immediately with plenty of water. Remove all contaminated clothing.
– In case gas is inhaled, move the casualty to a source of fresh air. Avoid taking deep breaths. Consult a doctor
(look out for a racing pulse, as vasodilating treatment may be required).
• Spillages:
– In case of contact with clothing, remove the clothing immediately and wash with plenty of water.
Chemical spillages in buildings must be washed away with water.
• Firefighting:
– Aqueous solutions of chlorine dioxide are not directly flammable. Extinguish the surrounding fire with water,
preferably using a fire sprinkler system to dilute the ambient gas. Inform the fire brigade of the installed
production capacity and any harmful starting substances that are being stored (precursor substances) so that
precautions can be taken regarding possible risks.
For emergency phone numbers, see the acceptance report.
7 / 152
2. Product description
Fig. 1 Oxiperm Pro – without cover and peripheral devices
The Grundfos Alldos Oxiperm Pro disinfection system is used to produce and dose chlorine dioxide for the disinfection
of drinking water, process water, cooling water and wastewater.
The device itself consists of a plastic system frame, on which the internal components are mounted. It is prepared for
wall- or floor-mounting and covered by a plastic cover.
The chemicals are supplied from two original chemical containers, which are located in two collecting trays directly
under the system (Oxiperm Pro systems up to 10 g/h) or in a separate tray for each container next to the unit
(Oxiperm Pro systems with more than 10 g/h). A suction lance is inserted in each container and is permanently
connected to the corresponding chemical pump in the device. The suction lance cables are used to send "pre-empty"
and "empty" signals to the control system.
The device is connected to two water lines:
• The drinking water line for supplying dilution water and flushing water.
• The main water line to be disinfected, into which the final ClO
2
solution is dosed.
2.1 Application examples
The Oxiperm Pro disinfection system can be used for three different types of application:
Group 1: Disinfection of drinking water lines
• The flow rate of the water in the lines can fluctuate greatly (peak times when water is used for bathing and
cooking).
• Examples: Drinking water lines in:
– hotels, multi-storey buildings
– schools, hospitals, nursing homes
– showers in sports facilities
– food and beverage plants
– waterworks
Group 2: Disinfection of industrial systems
• The water quantity in these systems is relatively constant.
• Examples:
– bottle cleaning plants in breweries
– industrial process water or wastewater systems
– cooling water systems.
Group 3: Shock disinfection
• Applications requiring large quantities of disinfectant in a short time
TM03 6914 4506
OCD-162-5, -10 OCD-162-30 OCD-162-60
8 / 152
• Example:
– cleaning of whirlpool baths
2.2 Functional principle
2.2.1 Production of chlorine dioxide
Chlorine dioxide is prepared in the reaction tank as follows (see. figs. 2 and 4):
1. When a finished batch of ClO
2
solution flows out of the reaction tank and into the reservoir tank, the float drops
with the liquid level in the reaction tank. 60 seconds (OCD-162-5) or 70 seconds (OCD-162-10, -30, -60) after
the float dropped below the lowest switching point (K1), the reaction tank is empty.
2. The control unit starts a new production process by opening the solenoid valve. The level in the reaction tank
rises.
3. When the water level in the reaction tank reaches the lowest level (K1), the solenoid valve closes, and the
water supply is interrupted.
4. The control unit starts up pump 1. HCl flows into the reaction tank.
5. When the float reaches level K2, the control unit stops pump 1.
6. The control unit starts up pump 2. NaClO
2
flows into the reaction tank.
7. When the float reaches level K3, the control unit stops pump 2.
8. The reaction process begins. Reaction time: 15 minutes.
9. When the reaction time has elapsed (timer), the control unit opens the solenoid valve again. The reaction tank
is filled up with water to level K4.
10.The reaction tank now contains the ready-to-use ClO
2
solution in a concentration of approximately 2 g per litre
of water. Provided that the reservoir tank is still full, the ready-to-use ClO
2
solution remains in the reaction
tank, and the water supply is shut off.
11. When the float switch in the reservoir tank sends an "empty" (K5) signal to the control unit, it opens the
solenoid valve again, and water flows into the reaction tank. The reaction tank overflows, and the hydraulic
effect causes the entire batch to flow through a pipe in the middle of the reaction tank into the reservoir tank.
When the level in the reservoir tank rises above K5, the water supply is shut off.
12. If the system is set to "once" mode, the production stops. In "continuous" mode, the production starts again.
See step 1.
13.The dosing pump doses the ClO
2
solution with the adjusted dosing capacity from the reservoir tank to the
injection unit.
2.2.2 Flow-rate-proportional dosing
Suitable for group 1 applications – drinking water:
1. The control system is set to proportional controller.
2. A water meter measures the water flow rate in the main water line and continuously sends measured values to
the Oxiperm Pro control system.
3. The proportional controller calculates the required ClO
2
dosing volume in proportion to the water flow rate in
the main line.
4. The proportional controller sends the corresponding output signals to the dosing pump.
5. The dosing pump doses the corresponding quantity of the ClO
2
solution from the reservoir tank into the main
water line.
6. An optional measuring cell monitors the ClO
2
concentration in the main line.
2.2.3 Setpoint-controlled dosing
Suitable for group 2 applications – industrial water:
1. The control system is set to setpoint controller. A setpoint for the desired ClO
2
concentration in the main line is
specified for the setpoint controller.
2. A measuring cell monitors the ClO
2
concentration in the main line.
9 / 152
3. The measuring cell continuously sends actual values for the ClO
2
concentration to the control system of the
disinfection system.
4. The setpoint controller compares the incoming actual values with the setpoint and based on the deviation
calculates the quantity of the ClO
2
solution that is required to achieve the desired concentration.
5. The setpoint controller sends output signals to the dosing pump.
6. The dosing pump doses the corresponding quantity of the ClO
2
solution from the reservoir tank into the main
water line.
A combined controller is also available for applications with setpoint controller and flow meter.
See section 5.10.1 Selecting the controller type and switching on the controller.
Fig. 2 Longitudinal cross section through the reaction tank and reservoir tank of OCD-162-5, -10
TM03 6915 4506
Pos. Description
A Manual drain
B From overflow line of multi-function valve
C To dosing pump
D To volume compensation bag
E HCl, NaClO
2
, H
2
O
FClO
2
solution
G Deaeration reservoir tank
10 / 152
Fig. 3 Longitudinal cross section through the reaction tank and reservoir tank of OCD-162-30 and through the reaction
tank of OCD-162-60
For information on controls and operating software settings, see sections 5.2 Operating software settings and
5.10 Setting the ClO
2
controller (not applicable for group 3 applications).
TM04 0950 1709
Pos. Description
A Manual drain
B From the overflow line of the multi-function valve
C To dosing pump
D To volume compensation bag
E HCl, NaClO
2
, H
2
O
FClO
2
solution
G Deaeration reservoir tank
K1
K2
K3
K4
F
G
D
E
E
E
OCD-162-60
K1
K2
K3
K4
K5
K6
A
B
C
D
F
F
E
E
OCD-162-30
E
11 / 152
Fig. 4 Diagram of process cycle for ClO
2
production
TM03 6916 4506
Process stop
"Start ClO
2
production" menu command
Solenoid valve opens
H
2
O supply 1
Level K1 reached/solenoid valve closes,
HCl pump starts
Level K2 reached/HCl pump stops,
NaClO
2
pump starts
Level K3 reached/NaClO
2
pump stops,
reaction time timer starts
Reaction
Timer times out, solenoid valve opens
H
2
O supply 2
Level K4 reached
Yes
HCI supply
NaClO
2
supply
No
"Continuous" production?
Level K1 reached/waiting time starts
ClO
2
dosing
Level in reservoir tank rises above K5 /
solenoid valve closes
Waiting time has elapsed
Stop H
2
O
Wait until reservoir tank is empty
Reservoir tank still full?
Level in reservoir tank drops under
level K5 / solenoid valve opens
H
2
O supply 3, reaction tank overflows
No
Yes
Reservoir tank still full?
12 / 152
2.3 Components of the Oxiperm Pro
Fig. 5 Components of Oxiperm Pro (here: OCD-162-5, -10)
2.3.1 External parts
See also the photos in section 15. Photos.
TM03 6897 4506
Pos. Components
1a Water line for supplying dilution water and flushing water (via solenoid valve in the device)
1b Extraction point for dilution water with stopcock
3 Chemical container for NaClO
2
(diluted concentration of 7.5 % by volume) with suction lance and collecting tray
4 Chemical container for HCl (diluted concentration of 9 % by volume) with suction lance and collecting tray
11 Main water line to be disinfected
12 Flow meter (or contact water meter)
14 Dosing line
15 Injection unit for dosing the ClO
2
16 Measuring water pipe
17 Measuring water extraction point
18 Measuring cell for checking the chlorine dioxide concentration in the main line (optional)
19 Power supply connection
Blue Red
13 / 152
2.3.2 Internal components
Pos. Components
2 Solenoid valve for supplying dilution water and flushing water
5 Chemical pump for sodium chlorite (pump 2)
6 Chemical pump for hydrochloric acid (pump 1)
7 Reaction tank with float switch
8 Chlorine dioxide reservoir tank with float switch and drain cock (bottom left)
9 Volume compensation bag for ClO
2
gas
10 Activated carbon filter for ClO
2
gas
13 Dosing pump with multi-function valve
20 Electronic control system with measured-value sensor for check measurements
21 Display with control and display elements
14 / 152
2.4 System peripheral devices and accessories
Fig. 6 Complete OCD-162-5, -10 system with measuring cell and without extension module
Fig. 7 Complete OCD-162-30, -60 system with measuring cell and without extension module
TM03 6918 4506TM03 0875 1509
Red
Blue
17
1a
14
1b
19
15
23
26
12
24
25
16
18
17
11
15 / 152
2.4.1 Accessories for the dilution water line (not included)
• Stopcock (ball valve)
• Tapping sleeve for dilution water extraction (optional) (if necessary, with double nipple and connection piece for
hose) (optional).
• Hose with connection to solenoid valve.
Stopcock and tapping sleeve are not required, if the bypass mixing module with dilution water connection has been
selected.
2.4.2 Accessories for the main water line (not included)
• Contact water meter or fitted flow meter (in case of a new water line, water flow meter that provides signals or
ultrasonic flow meter).
• Tapping sleeve for the injection unit (optional).
• Protective pipe for the dosing line, installed from the dosing pump to the injection unit (optional).
• Grundfos Alldos DIT photometer (measures ClO
2
concentration after dosing) (optional).
2.4.3 Measuring cell (optional)
• Measuring cell
• Tapping sleeve for sample-water extraction at the main line (not included).
• Hose from the sample-water extraction point to the measuring cell.
• Hose from the measuring cell to the sample-water drain.
2.4.4 Extension modules (optional)
The standard system can be extended using modules:
• measuring cell for cold and hot water (main water up to 50 °C, pressure 4 bar) for connection to the Oxiperm Pro
• measuring module for cold and hot water (main water up to 70 °C, pressure 8 bar) for connection to the
Oxiperm Pro
• bypass mixing module for cold and hot water for connection to the Oxiperm Pro (separate installation and operating
instructions).
Pos. Components
1a
Water line for supplying dilution water and flushing water (via solenoid
valve in the device)
1b Extraction point for dilution water with stopcock
3
Chemical container for NaClO
2
(diluted concentration of 7.5 % by volume)
with suction lance and collecting tray
4
Chemical container for HCl (diluted concentration of 9 % by volume) with
suction lance and collecting tray
11 Main water line to be disinfected
12 Flow meter (or contact water meter)
14 Dosing line
15 Injection unit for dosing the ClO
2
16 Hose for sample-water extraction
17 Sample-water extraction point
18 Measuring cell
19 Power supply connection/main switch
23 Connection cable for measuring cell
24 Sample-water drain
25 Connection cable for cleaning motor
26 Hose for dilution water
Note
In case of fluctuating flow rates in the main water flow, the use of a bypass mixing module is
recommended in order to optimise mixing and reduce the risk of corrosion. See the separate
installation and operating instructions for the bypass mixing module.
16 / 152
2.5 Power supply connections and electronic connections
The Oxiperm Pro disinfection system is equipped with an electronic control system. See fig. 8.
The control system has connections for the following:
• power supply cable to the main switch
• cable from the water flow meter or flow meter
• cable from external batch tank to level control, if necessary
• cables for measuring cell AQC-D1 or AQC-D6, if necessary:
– measuring electrode and counter-electrode
– sample-water deficiency sensor
– Pt100 sensor
– pH electrode, if necessary (for pH or ORP) (AQC-D1 only)
– cleaning motor (AQC-D1 only)
• or the cables from the measuring module, if necessary:
– measuring electrode and counter-electrode
– water sensor
– Pt100 sensor
• or the cable from the mixing module, if necessary:
– flow controller.
For additional connections, see section 4.7 Connecting the electronic components.
2.6 Control and display elements
Fig. 8 The display and control panel
2.6.1 Using the control panel
TM03 6920 4506
Buttons and LEDs Functions
[Esc] button Cancels command, exits menu
[Up] button Selects the previous menu item or sets a higher numerical value
[Down] button Selects the next menu item or sets a lower numerical value
[OK] button Confirms the menu selection
[Cal] button Calibration
[Man] button Manual operation
"Alarm" LED Alarm (red)
"Caution" LED Warning (yellow)
"Cal" LED Calibration (yellow)
"Man" LED Manual operation (yellow)
17 / 152
2.6.2 Using the display
After switching on the system (not initial start-up), the following display appears:
Fig. 9 Display level after starting the system
The header indicates the status (here: no process started). For symbols and numbers for relays, see the table below.
Press [OK] to access the MAIN MENU:
During operation, press [Esc] to access the display level:
Fig. 10 PROCESS RUNNING display level
Messages in the display level
TM03 6921 4506
MAIN MENU
PROCESS
CONTROLLER
ClO
2
ALARM
SERVICE
SETUP
MAINTENANCE
TM03 6922 4506
Number or
symbol
Message in the
display level
Meaning of the message
1
Headers
PROCESS
RUNNING
ClO
2
production is active.
PROCESS STOP ClO
2
production has been stopped.
PROCESS
ABORT
ClO
2
production has been aborted by a menu command or alarm.
FLUSHING Flushing is started automatically or manually.
2
Relays
1
Relay for solenoid valve.
Display:
White number on a black background: relay active.
Black number on a white background: relay not active.
2
Relay for HCl pump:
display as for 1.
3
Relay for NaClO
2
pump:
display as for 1.
4
Alarm relay:
display as for 1.
5
Warning relay:
display as for 1.
54321
.........
24
,5
°C
pH
7
,
35
5
4
3
2
1
0,23 mg
/
l
1
2
6
7
4/3
5
8
PROCESS RUNNING
18 / 152
3
Symbol
Symbol for relay for the pulse pause controller.
Symbol for controller stop for the pulse pause controller.
4
Symbol
Symbol for continuous controller.
Box with plotted line.
The height of the line is proportional to the actuating variable (ClO
2
dosing volume).
Line not visible:
actuating variable = 0 %
Line fills the entire box:
actuating variable = 100 %
Symbol for stop of continuous controller.
White box with a diagonal line through it.
5
Symbol
Symbol for external disturbance value input (water flow as pulse or current signal).
Box with plotted triangle.
The black fill is proportional to the flow (the greater the fill, the greater the flow, 0-100 %).
(Only visible if proportional or combined controller is configured.)
6
Value
e.g. 24.5 °C Water temperature, display value is only available with connected measuring cell.
7
Value
e.g. 0.23 mg/l ClO
2
concentration, display value is only available with connected measuring cell.
8
Value
e.g. 7.35 pH value in the sample water, display value is only available with connected measuring cell.
Number or
symbol
Message in the
display level
Meaning of the message
6
6
19 / 152
2.7 Operating modes
During the commissioning process, you set up the disinfection system in accordance with the application.
After switching on and starting up ClO
2
production via menu commands, the system runs fully automatically.
Two operating modes are available for the production of ClO
2
(see section 5.14 Setting the operating mode):
• continuous operation ("continuous" mode)
• single operation ("once" mode).
• external batch tank ("ext. batch" mode)
The appropriate dosing for the application is set at the dosing pump and via the controller parameter settings.
Dosing takes place automatically.
Manual operation is used for shutting down the controller (see section 5.14 Setting the operating mode) and for
temporary manual control if required (pulse dosing).
2.8 Access codes
When the system is ready for operation, the MAIN MENU cannot be accessed without a code.
Two different access authorisations/security levels are assigned for all submenus. Each code automatically enables the
levels below it too.
• User code: By default, all user menus can initially be accessed without a code request.
(When the menu selection has been confirmed using [OK], a code request is not displayed.)
Once the user has entered his/her own user code (MAIN MENU – SETUP – CHANGE CODE), the code request
appears before any user submenu can be accessed. The modified user code must only allow access for trained
users with appropriate technical training and experience. Access is enabled for 60 minutes after entry of the code.
• Service code: This code is reserved for trained Grundfos Alldos service engineers. Access is enabled for
30 minutes after entry. The service code is necessary for commissioning. See section 5.4 Switching on the system
– initial start-up.
• Super-user code: Some menus in the maintenance section are only accessible with a super-user code.
They are not described in these instructions.
For details of how to change the user code, see section Modifying setup in the separate installation and operating
instructions. This is only needed for basic factory settings.
20 / 152
2.9 User menu structure
Users can view certain submenus in the display and can also modify certain values.
2.9.1 Finding user menus
In the following tables, the first column indicates whether users can access a submenu:
• without a code (0)
• with the user code (A).
Users can access the following submenus from the MAIN MENU (without a code or with the user code):
User menus,
Note
All software menus can be selected from the MAIN MENU using the [Up] and [Down] buttons
and accessed using [OK].
Press [Esc] to return to the menu level above.
For operating instructions for each menu, see section 5. Commissioning.
Code Main menu Submenu 1 Submenu 2 Submenu 3 Submenu 4 Submenu 5
A
Main menu
Process
Start
Start
Start ClO
2
production?
ABack
A
Abortion
Abortion
Abort ClO
2
production?
ABack
A
Operation
continuous
A once
A ext. batch
0
Service
Process
Status
Display:
Process Status
0 List of events
0
ClO
2
production
Cycles
0
Chemicals
HCl/NaClO
2
since 14.09.2006
HCl (l)
NaClO
2
(l)
reset
0 Age of ClO
2
(mm:ss)
0 Maintenance
A
Flushing
Start
A Abortion
0
Measurement
ClO
2
Measured value
0 CalData/logbook
0 Temperature
°C or °F
Measured value
0
pH or ORP
Measured value
0 CalData/logbook
0ClO
2
controller
Display:
Controller setting
0
Water flow meter
1.00 - 100.00 pulses/
sec.
(Note 5*)
50 pulses/sec., 50 %*
(or: 5 mA, 25 %)
0 Test display
Program version
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152