Dwyer Series BBV-0 User manual

Type
User manual
Series BBV-0 2-Valve Block Manifold
Specications - Installation and Operating Instructions
Bulletin V-BBV-0
The SERIES BBV-0 2-Valve Block Manifold is perfect for use over a broad range of
industrial applications including oil reneries, nuclear power stations, petrochemical
processing, and more. The Series BBV-0 is forged from 316 stainless steel bar stock
and designed to withstand repeated open and close operations. Suited to control oil,
water, toxic uids, chemicals, air, and steam; the 2-valve block manifold has (1) isolate
and (1) vent valves. Each valve stem is precision machined with hard seats to reduce
operating torque.
The BBV-0F and BBV-0N are designed to mount directly to industrial pressure
transmitters. The BBV-0F comes with two 7/16-20 UNF mounting bolts and one PTFE
gasket.
INSTALLATION
Refer to the drawing shown above. The connections to the device must be made
accordingly. The BBV-0 2-Valve Block Manifold can be mounted in any position. The
BBV-0 is tted with color-coded caps for valve identication:
ISOLATE (Blue)
VENT (Red)
The BBV-0 2-Valve Block Manifold require periodic maintenance. It is recommended
to change the sealing gaskets periodically for safety.
SPECIFICATIONS
Service: Compatible liquids, gases, or steam.
End Connections: Process connection: 1/2˝ male NPT; Instrument connection: No
ange: 1/2˝ female NPT; Flange: 1/2˝ DIN 19213 ange; Vent/test: 1/4˝ female NPT.
Wetted Materials: Body, stem, valve assembly: 316 SS; Stem packing: PTFE.
Pressure Limit: 6000 psi (400 bar).
Temperature Limit: 464°F (240°C).
Other Materials: Handle: 304 SS.
BBV-0F
BBV-0N
FLOW DIAGRAM
VENT
PROCESS
ISOL
ATE
INSTRUMENT
1. Do not remove the instrument from BBV-0 2-Valve Block
Manifold when the system is under pressure.
2. Do not remove the safety pin provided on the body.
3. Do not use the BBV-0 2-Valve Block Manifold above the recommended working
pressure and temperature given in the specications.
CAUTION
MAINTENANCE
After nal installation of the block valve, some routine maintenance is required.
The Series BBV-0 is not eld repairable, with the exception of previously stated
maintenance, and should be returned if repair is needed (eld repair should not be
attempted and may void the warranty). Be sure to include a brief description of the
problem plus any relevant application notes. Contact customer service to receive a
return goods authorization (R.G.A.) number before shipping.
W.E. ANDERSON
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360, U.S.A.
Phone: 219/879-8000
Fax: 219/872-9057
www.dwyer-inst.com
A DIVISION OF
DWYER INSTRUMENTS, INC.
By Dwyer
©Copyright 2017 Dwyer Instruments, Inc. Printed in U.S.A. 5/17 FR# 443874-00 Rev. 2
4-41/64
[118.00]
1-47/64
[44.00]
3-15/64
[82.00]
2-23/64
[60.00]
3-3/4
[95.00]
MAX OPEN
3-5/8
[92.00]
MAX. OPEN
1-5/8
[41.30]
2X Ø15/32
MOUNTING HOLES
[Ø12.00]
1/2˝ NPT PROCESS
CONNECTION
1-17/64
[32.00]
4-17/32
[115.00]
1/2˝ NPT MALE
1/2˝ NPT
FEMALE
1/4˝ NPT VENT
PORT (PLUGGED)
1-17/64
[32.00]
7-31/64
[190.15]
DIMENSIONS
BBV-0N
BBV-0F
W.E. ANDERSON
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360, U.S.A.
Phone: 219/879-8000
Fax: 219/872-9057
dwyer-inst.com
A DIVISION OF
DWYER INSTRUMENTS, INC.
  • Page 1 1
  • Page 2 2

Dwyer Series BBV-0 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI