ADTRAN Total Access 1500 Installation and Maintenance

Type
Installation and Maintenance
®
Section 61180109L1-5D
Issue 4, May 2006
CLEI Code: VAIM74ZJ_ _
61180109L1-5D 1
Trademarks: Any brand names and product names included in this document are
trademarks, registered trademarks, or trade names of their respective holders.
CONTENTS
1. General .................................................................... 1
2. Installation............................................................... 2
3. Provisioning ............................................................ 3
4. Alarms ................................................................... 11
5. Tests ...................................................................... 11
6. Maintenance .......................................................... 11
7. Specifications ........................................................ 12
8. Warranty and Customer Service ........................... 12
FIGURES
Figure 1. Quad LIU Front Panel.................................. 1
Figure 2. DIP Switches................................................ 3
Figure 3. Quad LIU Menu Tree .................................. 7
TABLES
Table 1. Compliance Codes ........................................ 2
Table 2. Front Panel LEDs.......................................... 4
Table 3. Quad LIU Switch Settings ............................ 5
Table 4. Quad LIU Specifications............................. 12
1. GENERAL
This practice is an installation and maintenance guide
for the ADTRAN
®
Total Access 1500
®
Quad Line
Interface Unit (LIU) List 1 Common Module. Figure 1
shows the Quad LIU (P/N 1180109L1) front panel.
Revision History
This is the fourth issue of this practice. This issue
reflects updates to the Total Access 1500 System
Software Release 3.0, Quad LIU software T09Q, and
incorporates the addition of new features including the
following:
Addition of a DLC counting sequence in Quad T1
mode
Incorporation of an automatic mapping for 2B+D
ISDN when in Dual T1 mode
Add support to automatically detect installation in
19-inch chassis
Removed signalling bits from 4-wire TO
A full list of features is detailed in Total Access 1500
System Release 3.0 Release Notes available at
www.adtran.com
.
Figure 1. Quad LIU Front Panel
NOTE
This release of the LIU software is designed to
operate with System Controller Unit (SCU)
software release V08 or later to support these
feature enhancements.
Description
The Quad LIU is a common module for the Total
Access 1500 chassis (P/N 1180001L1) or the Total
Access 1500 19-inch chassis (P/N 1180019L1).
The Quad LIU connects the chassis to a T1 line at the
DSX-1 or DS1 level. All data formatting and line
encoding as well as backplane timing and control are
performed by the Total Access 1500 Quad LIU.
LIU
1180109L1
A
C
P
YEL
REM
MASTER
B
D
RED
RCV
TEST
STATUS
TX
MONITOR
RX
Total Access 1500 Quad Line Interface Unit (LIU) List 1
Installation and Maintenance Practice
2 Issue 4, May 2006 61180109L1-5D
Features
The basic features of the Quad LIU include the
following:
Terminates up to 4 T1 lines providing DSX-1 or
DS1 interface to the network
Terminates 1 T1 Protect Line for LIU protection
Supports up to 96 DS0s
SF, ESF, or SLC-96 data framing formats
AMI or B8ZS line code formats
Local and remote loopbacks
Front panel bantam jacks for monitoring T1s
Local, loop, or external timing modes
Supports ANSI T1.403 in-band payload and line
loopback
Supports SLC Mode I and III
Compliance
Table 1 shows the compliance codes for the Quad LIU,
which is NRTL listed to the applicable UL Listing.
The Total Access 1500 chassis frame ground terminal
must be connected to an earth ground to ensure that the
front panel of the Quad LIU is properly grounded via
the backplane connector.
This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions:
1. This device cannot cause harmful interference.
2. This device must accept any interference received,
including interference that can cause undesired
operation.
Changes or modifications not expressly approved by
ADTRAN could void the user’s authority to operate this
equipment.
2. INSTALLATION
After unpacking the Quad LIU, inspect it for damage. If
damage has occurred, file a claim with the carrier then
contact ADTRAN Customer Service. Refer to the
Warranty and Customer Service section for further
information. If possible, keep the original shipping
container for returning the Quad LIU for repair or for
verification of shipping damage.
CAUTION
Electronic modules can be damaged by ESD.
When handling modules, wear an antistatic
discharge wrist strap to prevent damage to
electronic components. Place modules in
antistatic packing material when transporting
or storing. When working on modules, always
place them on an approved antistatic mat that is
electrically grounded.
Shipping Contents
The contents include the following items:
Quad LIU
Quad LIU Installation and Maintenance Practice
Instructions for Installing the Module
The Quad LIU plugs directly into the ADTRAN Total
Access 1500 chassis. No installation wiring is required.
The Quad LIU should be installed in the Total Access
1500 chassis in the slot labeled
LIU-A or LIU-B. Refer to
the Provisioning section prior to module insertion.
CAUTION
This release of the LIU software is designed to
operate with SCU software release V08 or later
to support feature enhancements. SCU
software can be found at www.adtran.com
under the Service/Support page.
Table 1. Compliance Codes
Code Input Output
Power Code (PC) C C
Telecommunication Code (TC) X
Installation Code (IC) A
C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
61180109L1-5D Issue 4, May 2006 3
To install the Quad LIU, perform the following steps:
1. If present, remove the LIU Blank (P/N 1180010L1)
from the appropriate LIU common module slot of
the Total Access 1500 chassis.
2. Hold the Quad LIU by the front panel while
supporting the bottom side.
3. Align the Quad LIU card edges to the guide
grooved for the slot designated
LIU-A.
4. Insert the Quad LIU until the edge connector seats
firmly into the backplane.
5. Push the ejector in place to ensure the Quad LIU is
fully seated.
NOTE
An additional
LIU-B slot is also provided for
optional redundancy. For dual operation, only
Quad LIUs of the same hardware version and
software revision should be installed.
When the Quad LIU first powers up, it performs the
power up self-tests which check the DRAM and
checksum. Once the power up self-test is complete, the
LEDs reflect the true state of the hardware.
Front Panel LEDs
The front panel LEDs provide status and alarm infor-
mation. See Table 2 on page 4 for LED descriptions.
Front Panel Pushbutton
A pushbutton switch labeled
STATUS is accessible
from the front panel to aid in test and troubleshooting.
The
MONITOR TX and RX bantam jack is provided for
T1 access.
NOTE
TX = Transmit (Out) and RX = Receive (In)
3. PROVISIONING
All options on the Quad LIU are provisionable either
manually, using internal DIP switches, or electronically
using the SCU
ADMIN port.
Manual Provisioning
The DIP switches SW1 and SW2 provide the Quad LIU
with the necessary option settings for DSX/DS1 modes
of operation. Figure 2 shows the orientation of the DIP
switches. Table 3 on page 5 shows the available DIP
switch settings.
Figure 2. DIP Switches
NOTE
DIP switch settings can be used for the initial
turn up of the system, and can automatically
assign time slots to physical slots, depending
on the setting selected. If any setting is
changed via the VT100 interface, the
REM
LED on the front panel lights indicating that
the settings have changed.
Electronic Provisioning
The craft ports on the SCU are used to change default
options and obtain access module status through menu
screens. To access the menu screens, connect a VT100
terminal or computer running a terminal emulation
program to the SCU front panel
ADMIN port using a
standard male RS-232, DB-9 cable.
ADMIN port
settings are as follows:
9600 baud
No parity
8 data bits
1 stop bit
No flow control
Windows HyperTerminal
Windows HyperTerminal can be used as a VT100
terminal emulation program. Refer to the Help section
of HyperTerminal for additional information.
NOTE
To ensure proper display background, select
VT100 terminal emulation under Settings.
ON
OFF
4 Issue 4, May 2006 61180109L1-5D
Table 2. Front Panel LEDs
Label Condition Description
A
Red
Yellow
Green
Flashing
Off
ON = T1-A in Red Alarm
ON = T1-A in Yellow Alarm
ON = T1-A Active
FLASHING = T1-A in Test
OFF = In Monitor Mode
B
Red
Yellow
Green
Flashing
Off
ON = T1-B in Red Alarm
ON = T1-B in Yellow Alarm
ON = T1-B Active
FLASHING = T1-B in Test
OFF = In Monitor Mode
C
Red
Yellow
Green
Flashing
Off
ON = T1-C in Red Alarm
ON = T1-C in Yellow Alarm
ON = T1-C Active
FLASHING = T1-C in Test
OFF = In Monitor Mode
D
Red
Yellow
Green
Flashing
Off
ON = T1-D in Red Alarm
ON = T1-D in Yellow Alarm
ON = T1-D Active
FLASHING = T1-D in Test
OFF = In Monitor Mode
P
Red
Yellow
Green
Flashing
Off
ON = T1-P in Red Alarm
ON = T1-P in Yellow Alarm
ON = T1-P Active
FLASHING = T1-P in Test
OFF = In Monitor Mode
RED
Red ON = Monitored T1 in Red Alarm
YEL
Yellow ON = Monitored T1 in Yellow Alarm
RCV
Red ON = Monitored T1 bipolar or logic error detected
REM
Green ON = Remotely Provisioned (Craft or Network)
OFF = Locally Provisioned (DIP Switches)
TEST
Yellow ON = Test Mode Active
MASTER
Green
Flashing
ON = Online Unit
FLASHING = Provisioning in progress. Failover not possible.
STATUS
Switch Momentary activation cycles through the T1s for monitoring purposes.
Activating the switch for two or more seconds causes provisioning to
toggle between local and remote.
61180109L1-5D Issue 4, May 2006 5
* Denotes factory default settings.
Note: SW1-1 through SW2-4 set up all T1s identically.
Table 3. Quad LIU Switch Settings
Switch Function Description
SW1 DSX-1 Line Build Out
and DS1 Attenuation
Selects the Line Build Out in feet, Attenuation in Decibels (dB)
Distance SW1-1 SW1-2 SW1-3
0-133 (Feet)/0 dB* OFF OFF OFF
133-266 OFF OFF ON
266-399 OFF ON OFF
399-533 OFF ON ON
533-655 ON OFF OFF
–7.5 dB ON OFF ON
–15 dB ON ON OFF
–22.5 dB ON ON ON
SW2-1
OFF
ON
Line Code Format
AMI
B8ZS*
Enables Bipolar Eight Zero Substitution (B8ZS), which allows for Clear Channel
operation for the T1 carrier system, or Alternate Mark Inversion (AMI). This
option must be configured identically with all other T1 network equipment on this
circuit.
SW2-2
OFF
ON
Framing Format
SF
ESF*
Enables either Extended Superframe Format (ESF) or Superframe Format (SF).
This option must be configured identically with all other T1 network equipment on
this circuit.
SW2-3
SW2-4
Timing Mode Determines a clock source for the Total Access 1500 channel bank.
Function SW2-3 SW2-4
Local Clock – provided by local LIU OFF OFF
Loop A Clock – uses recovered clock from T1 bit
stream*
OFF ON
External Clock input ON OFF
SW2-5
SW2-6
SW2-7
Terminal Mode Select the appropriate Terminal Type and counting mode for the Total Access 1500
system.
Terminal Mode Counting SW2-5 SW2-6 SW2-7
D4 D4 OFF OFF OFF
D4 D1D OFF OFF ON
DLC (Quad D4) D4 OFF ON OFF
SLC Mode 1* D1D OFF ON ON
SLC Mode 3 D4 ON OFF OFF
SLC Mode 3 D1D ON OFF ON
6 Issue 4, May 2006 61180109L1-5D
Password and User ID
Password protection is a function of the SCU and is
factory disabled. If password authentication is enabled,
then the SCU displays the Logon screen. A valid User
Name and Password are required to access menus.
NOTE
The factory default User Name is “user”, and
the default Password is “password”. The User
Name and Password are not case sensitive.
Menu Navigation
To traverse through the menus, select the desired entry,
and press
ENTER. To return to previous menus, press the
ESC key.
The menu tree in Figure 3 on page 7 illustrates the path
to every provisioning, performance, and test access
point in the Total Access 1500 Quad LIU menu.
Menus
The following subsections describe the Total Access
1500 Quad LIU menu screens.
Main Menu
The LIU main menu provides access to the Quad LIU
for various functions such as viewing configuration,
provisioning, viewing the current status of the module,
setup of alarms, testing, and performance monitoring.
Configuration Screen
The LIU Configuration screen is a read-only display. It
provides configuration data pertaining to the Total
Access 1500 Quad LIU and cannot be changed. Infor-
mation such as unit name, CLEI code, part number,
product revision, and software revision are displayed.
Items such as software revision reflect new software
revisions as upgrades are performed.
Provisioning Menu
The LIU Provisioning menu is a top-level provisioning
screen which contains several other provisioning
categories that are used to make provisioning changes to
the Total Access 1500 Quad LIU.
The provisioning categories are listed below with all
respective submenus listed under each category.
Bank Provisioning
The Bank Provisioning menu items are used to set
general channel bank provisioning settings. Options
include the following:
1. Bank Mode: This option is used to select the bank
mode for the Total Access 1500. The settings
include the following:
•Single T1
•Dual T1
Quad T1
SLC-96 Mode I
SLC-96 Mode III
•Manual Map
NOTE
If Manual Map is selected, time slots must be
assigned using the
Time Slot Assignment
option from the LIU Provisioning menu.
2. Counting Sequence: This option is used to select
the counting sequence of the selected T1. The
settings include the following:
•D4
•D1D
•DLC
NOTE
DLC counting is only available when in Quad
T1 Bank Mode and allows for automatic
mapping of the DS0 from each T1 to a specific
50-pin Amp connector. When provisioned,
DS0 from T1A are mapped to ports associated
with P1 (T/R), T1-B to P2 (T1/R1), T1-C to P3
(E/SG), and T1-D to P4 (M/SB) of the 23-inch
chassis (P/N 1180001L1). Not intended for use
with 19-inch chassis
3. In-band Loopback: This option is used to enable
or disable ANSI T1.403 in-band loopbacks.
4. Protection Line Switching: This option is used to
enable or disable T1 protection line switching.
NOTE
Protection Line Switching is only available for
SLC-96 Modes I and III.
61180109L1-5D Issue 4, May 2006 7
Figure 3. Quad LIU Menu Tree
1. Configuration
2. Provisioning
3. Timing Provisioning
1. Circuit Select
3. Line Buildout
2. Operation State
4. Line Code
1. Bank Mode
2. Counting Sequence
Unit Name
Part Number
CLEI Code
Product Revision
Software Revision
1. Bank Provisioning
2. DS1 Circuit Provisioning
3. Inband Loopback
1. Single T1
3. Quad T1
2. Dual T1
4. SLC-96 Mode I
5. SLC-96 Mode III
6. Manual Map
1. D4
2. D1D
1. Circuit A
3. Circuit C
2. Circuit B
5. Circuit P
4. Circuit D
1. Enable
2. Disable
1. 0-133 ft.
3. 266-399 ft.
2. 133-266 ft.
5. 533-655 ft.
4. 399-533 ft.
6. 0 dB
8. -15 dB
9. -22.5 dB
7. -7.5 dB
1. B8ZS
2. AMI
1. SLC-96
3. SF
2. ESF
1. Clock Mode
3. Secondary Timing Source
2. Primary Timing Source
2. Revertive
1. Non-revertive
1. Local
3. Loop B
2. Loop A
5. Loop D
4. Loop C
6. Loop P
7. CLK
A
1. Enable
2. Disable
5. Framing
1. Enable
2. Disable
4. Protection Line Switching
4. Time Slot Assignment
2. Assign T1 A
1. Assign by Card Slot
3. Assign T1 B
4. Assign T1 C
5. Assign T1 D
5. V90 LSB Marking
3. DLC*
* DLC Counting only applicable in Quad T1 Bank mode
8 Issue 4, May 2006 61180109L1-5D
Figure 3. Quad LIU Menu Tree (continued)
3. Status
5. Test
6. Performance Monitoring
4. Alarms
1. T1 Loopbacks
2. T1 Monitor Select
4. LIU Reset
1. None
3. T1 B
2. T1 A
5. T1 D
4. T1 C
Line Buildout
Framing
LIne Code
Loopback
Inband Loopback
Loop Status
Circuit A
Bank Mode
Timing Source
1. Enable
2. Disable
Primary
Secondary
Current
1. Daily
3. Qtr-Hour
2. Far-End Daily
5. Daily Threshold
4. Far-End Qtr-Hour
6. FE Daily Threshold
8. FE Qtr-Hour Threshold
9. Reset Performance Registers
7. Qtr-Hour Threshold
10. Restore Factory Default Thresholds
12. Disable all LIU Threshold Alarms
13. Select T1
11. Enable all LIU Threshold Alarms
Circuit C
Circuit B
Circuit P
Circuit D
1. T1-A
3. T1-C
2. T1-B
5. T1-P
4. T1-D
1. None
3. Line & Local
2. Local
5. Line
4. Payload
6. Remote Inband
6. T1 P
A
M.T.A. Status
1. CLK S OOS Alarm
7. Remote Line*
6. Remote Inband*
* Not available in SF or SLC-96 Framing.
1. T1-A
3. T1-C
2. T1-B
5. T1-P
4. T1-D
61180109L1-5D Issue 4, May 2006 9
DS1 Circuit Provisioning
The DS1 Circuit Provisioning menu items are used to
provision the DS1 circuit. The options include the
following:
1. Circuit Select: This option is used to select the
circuit to be provisioned. The settings include the
following:
Circuit A
Circuit B
Circuit C
Circuit D
Circuit P
2. Operation State: This option is used to enable or
disable the operation state of circuits A through P.
3. Line Buildout: This option is used to select the
line length or the attenuation loss of the selected
T1. The settings include the following:
0-133 feet
133-266 feet
266-399 feet
399-533 feet
533-655 feet
•0 dB
–7.5 dB
–15 dB
–22.5 dB
4. Line Code: This option is used to select the line
coding type. The settings include the following:
B8ZS: This setting is used to enable Bipolar Eight
Zero Substitution (B8ZS), which allows for Clear
Channel operation for the T1 carrier system. This
option must be configured identically with all
other T1 network equipment on this circuit.
AMI: This setting is used to enable Alternate
Mark Inversion (AMI). This option must be
configured identically with all other T1 network
equipment on this circuit.
5. Framing: This option is used to select the framing
format for the selected T1. This setting must be
configured identically with all other T1 network
equipment on this circuit. The settings include the
following:
SLC-96: This setting is used to enable SLC-96
framing.
ESF: This setting is used to enable Extended
Superframe Format.
SF: This setting is used to enable Superframe
Format.
Timing Provisioning
The Timing Provisioning menu items are used to
establish the clock mode and primary and secondary
timing source. The options include the following:
1. Clock Mode: Settings include Non-revertive or
Revertive clock mode. This decision should be
based on whether a primary and secondary timing
source are available. In the event that the primary
timing source is lost, the Total Access 1500 LIU
automatically switches to the secondary timing
source.
Revertive: This setting allows the unit to revert to
the primary timing source if and when it becomes
available.
Non-revertive: This setting allows the unit to
remain on the secondary timing source. If Non-
revertive is chosen and the secondary timing
source becomes active due to a primary timing
source failure and the secondary source fails, the
unit switches to the primary timing source if it has
become available.
2. Primary Timing Source: This option is used to
select the primary timing source for the T1s. The
settings include the following:
•Local
Loop A
Loop B
Loop C
Loop D
Loop P
•CLK
3. Secondary Timing Source:
This option is used to
select the secondary timing source for the T1s. The
settings include the following:
•Local
Loop A
Loop B
Loop C
Loop D
Loop P
•CLK
This timing source becomes the current timing
source if the primary timing source is lost. If both
timing sources are lost, the timing reverts to local.
As timing sources are regained, the current timing
source reverts to the primary or secondary timing
source as they become available.
10 Issue 4, May 2006 61180109L1-5D
Time Slot Assignment
Used to assign time slots when the bank is in manual
map mode. This option allows time slots to be assigned
by T1 A, T1 B, T1 C, T1 D or by the card slot.
V90 LSB Marking
V90 Least Significant Bit (LSB) Marking sets the LSB
to a 1 in the direction of the analog loop. This is done in
order to improve V.90 modem performance. This
option should typically be enabled when the T1 passes
through a Digital Cross Connect (DCC).
NOTE
This option is enabled on a per DS0 basis.
Status Screen
The LIU Status screen is used to quickly view the status
of the loops, the provisioned settings for each T1, the
bank mode, M.T.A. status, the settings for primary and
secondary timing, and the status of the timing source.
Alarms Menu
The LIU Alarms menu is used to enable or disable the
external clock alarms. These alarms should be enabled
when a timing source is connected to the external clock
pins.
Test Menu
The LIU Test menu is used to perform loopbacks, select
which T1 is monitored by the front panel monitor jacks,
or reset the Quad LIU.
Performance Monitoring Menu
The LIU collects and stores the Performance
Monitoring (PM) information statistics for each of the
T1s. This PM information is stored in non-volatile
memory and is accessible through the Performance
Monitoring menu. The options include the following:
1. Daily: This option is used to display daily counts
of multiple performance monitoring statistics.
2. Far-End Daily: This option is used to display
daily counts of multiple performance monitoring
statistics associated with the far-end.
3. Qtr-Hour: This option is used to display counts
of performance monitoring statistics in seven
15-minute intervals.
4. Far-End Qtr-Hour: This option is used to display
counts of performance monitoring statistics in
seven 15-minute intervals associated with the far-
end.
5. Daily Threshold: This option is used to set
threshold points for daily counts and enable or
disable an alarm that occurs when this threshold is
exceeded.
6. FE Daily Threshold: This option is used to set
threshold points for far-end daily counts and enable
or disable an alarm that occurs when this threshold
is exceeded.
7. Qtr-Hour Threshold: This option is used to set
threshold points for 15-minute counts and enable
or disable an alarm that occurs when this threshold
is exceeded.
8. FE Qtr-Hour Threshold: This option is used to
set far-end threshold points for 15-minute counts
and enable or disable an alarm that occurs when
this threshold is exceeded.
9. Reset Performance Registers: This option is used
to reset all performance registers.
10. Restore Factory Default Thresholds: This option
is used to reset thresholds back to factory defaults.
11. Enable all LIU Threshold Alarms: This option is
used to enable all LIU threshold alarms.
12. Disable all LIU Threshold Alarms: This option is
used to disable all LIU threshold alarms.
13. Select T1: This option is used to select the T1 for
which performance monitoring statistics are to be
displayed.
For each statistic, the following specific data is
stored:
Near End – Line:
- Code Violations (BVP)
- Errored Seconds (ES), and Severely Errored
Seconds (SES)
Near End – Path:
- Code Violation (BVP)
- Errored Seconds (ES)
- Severely Errored Seconds (SES)
- Bursty Errored Seconds (BES)
- Severely Errored Framing Seconds (SEFS)
- Controlled Slip Seconds (CSS)
- Unavailable Seconds (US)
61180109L1-5D Issue 4, May 2006 11
Far End – Path:
- Code Violation (BVP)
- Errored Seconds (ES)
- Severely Errored Seconds (SES)
- Bursty Errored Seconds (BES)
- Severely Errored Framing Seconds (SEFS)
- Controlled Slip Seconds (CSS)
- Unavailable Seconds (US)
The threshold for each statistic can be indepen-
dently enabled, disabled, or have a specific value
entered. When enabled, and crossing of the thresh-
old value results in a threshold entry into the Total
Access 1500 Alarm Log. All thresholds are
defaulted to disabled.
4. ALARMS
The Total Access 1500 Quad LIU supports an external
clock input out-of-service alarm and can be enabled or
disabled. When the alarms are enabled, an alarm
condition is created when the external timing source is
lost.
5. TESTS
The Test menu controls testing for the Total Access
1500 Quad LIU. The Test menu is used to select either
T1 A or B for testing, perform local and remote
loopbacks, select which T1 to monitor, and reset the
LIU. The loopbacks are described below.
Loopback Tests
The Quad LIU supports loopback tests to aid circuit
turnup and maintenance efforts. These tests are initiated
from the Total Access Site Manager or the Total Access
1500 local
ADMIN port on the SCU.
Local Loopback
T1 data is looped back toward the customer. The
transmit data is looped back after it has passed through
the framer and LIU circuitry.
Line and Local Loopback
The Quad LIU supports a bidirectional loopback via
menu access only. The loopback in the network
direction is of a line loopback type.
Payload Loopback
For a Payload Loopback, the T1 data is looped back
toward the network. The framing pattern, CRC6 calcu-
lation, and FDL bits are not looped back.
Line Loopback
For a Line Loopback, the T1 data is looped back toward
the network with framing and line coding unchanged.
Remote In-band Loopback
A Remote In-band Loopback initiates the transmission
of an in-band line loopback code toward the far end as
specified in ANSI T1.403.
Remote Line Loopback
A Remote Line loopback initiates the transmission of a
Facility Data Link (FDL) line loop up code toward the
far end as specified in ANSI T1.403. This loopback is
only available when the Total Access 1500 is provi-
sioned for Extended Superframe (ESF).
Remote Payload Loopback
A Remote Payload Loopback initiates the transmission
of a FDL Payload loop up code toward the far end as
specified in ANSI T1.403. This loopback is only
available when the Total Access 1500 is provisioned for
Extended Superframe (ESF).
6. MAINTENANCE
The Total Access 1500 Quad LIU requires no routine
maintenance for normal operation.
ADTRAN does not recommend that repairs be
attempted in the field. Repair services can be obtained
by returning the defective unit to ADTRAN. Refer to
the Warranty and Customer Service section for further
information.
12 Issue 4, May 2006 61180109L1-5D
7. SPECIFICATIONS
Specifications for the Total Access 1500 Quad LIU are
detailed in Table 4.
8. WARRANTY AND CUSTOMER SERVICE
ADTRAN will replace or repair this product within the
warranty period if it does not meet its published specifi-
cations or fails while in service. Warranty information
can be found at www.adtran.com/warranty
.
Refer to the following subsections for sales, support,
Customer and Product Service (CAPS) requests, or
further information.
ADTRAN Sales
Pricing/Availability:
800-827-0807
ADTRAN Technical Support
Pre-Sales Applications/Post-Sales Technical
Assistance:
800-726-8663
Standard hours: Monday - Friday, 7 a.m. - 7 p.m. CST
Emergency hours: 7 days/week, 24 hours/day
ADTRAN Repair/CAPS
Return for Repair/Upgrade:
(256) 963-8722
Repair and Return Address
Contact CAPS prior to returning equipment to
ADTRAN.
ADTRAN, Inc.
CAPS Department
901 Explorer Boulevard
Huntsville, Alabama 35806-2807
Table 4. Quad LIU Specifications
Specification Description
Environmental
Operating Temperature:
Storage Temperature:
Relative Humidity:
Maximum Current Draw
@ –48 VDC:
Maximum Heat
Dissipation:
–40°C to +65°C
–40°C to +85°C
95 percent maximum @
50°C, noncondensing
Online: 0.152 amps
Offline: 0.055 amps
Online: 7.3 watts
Offline: 2.6 watts
Physical
Dimensions:
Weight:
Height: 3.125 inches
Width: 1.14 inches
Depth: 10.1 inches
1 pound
Part Number
Total Access 1500
Quad LIU: 1180109L1
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

ADTRAN Total Access 1500 Installation and Maintenance

Type
Installation and Maintenance

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI