ADTRAN D4 DS0 DP Practices

Type
Practices
Section 61109.003L1-5A
Issue 1, January 1997
CLEI Code D4D2T1W_ _ _
ADTRAN Model D4 DS0 DP
SD4/Performance Monitoring
GENERAL
For use in all D4 channel bank and SLC 96 terminal applications
NEAR and FAR logic level bantam test access
Non-intrusive monitoring of received data from NEAR or FAR direction
Switched 56k tandem signaling option
Error correction, latching loopback, and zero code suppression options
Remotely provisionable; compatible with Performance Monitoring and
Digital System-6 interfaces
OPTIONS
ERROR CORRECTION is enabled by turning SW1-1 on.
Select the appropriate RATE from switches SW1-2 to SW1-5. Only one rate switch should be turned on.
Select SWITCHED 56 (SW1-6) to maintain A and B bit signaling between two carrier system timeslots. When in the off
position, data is passed transparently between carrier timeslots.
Select the appropriate BANK TYPE from switches SW3-1 to SW3-3. Only one of these switches should be turned on.
ZERO CODE SUPPRESSION is enabled by turning switch SW3-4 on.
LATCHING LOOPBACK is enabled by turning switch SW3-5 on.
LED INDICATORS
REM (Remote Provisioning): On indicates unit has been remotely provisioned, flashing indicates remote control link is
active. Push AP (Alternate Provisioning) button totoggle between manual and remote provisioning.
PM (Performance Monitor): Indicates unit has established PM link with PM channel bank commons
•LB (Loopback): Indicates latching DS0 or DS1 loopback activation
TESTING
The ADTRAN DS0 DP SD4/PM is equipped with logic level bantam test access jacks that permit testing in both
directions using a portable test set. Choose NEAR to test toward the 4-wire office signal direction; choose FAR to
test toward the T-carrier.
In the FAR direction, a DS0 DP latching loopback sequence for the first DSO DP will loop the unit directly connected
to the test set. In the NEAR direction, a DS0 DP latching loopback sequence for the first DS0 DP will be transmitted
across the 4-wire interface to the tandem DS0 DP unit.
C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
Rx
Tx
AP
REM
PM
LB
L
O
G
I
C
DS0 DP
1109003L1
SD4/PM
The ADTRAN D4 DS0 DP SD4/PM provides the interface between the WECO-compatible
D4 channel bank or SLC 96 terminal and the standard DS-0 4-wire central office signal. The
DS0 DP may be used to interoperate with another DS0 DP or OCU DP across a T-carrier
system or interface other DS-0 level equipment such as a multipoint junction unit (MJU) or
subrate multiplexer unit (SRMU). Either DS-0A or DS-0B formatted signals are accepted by
the DS0 DP. In SW56 mode, the ADTRAN DS0 DP SD4/PM will maintain A and B bit
signaling between two carrier systems. The unit can be remotely provisioned through
ADTRAN Performance Monitoring and Digital System 6 interfaces.
PRACTICES
61109.003L1-5A
Trademarks: Any brand names and product names included in this document are trademarks, registered trademarks, or trade names of their respective
holders.
WARRANTY AND CUSTOMER SERVICE
ADTRAN will replace or repair this product within ten years from the date of shipment if the product does not
meet its published specifications or if it fails while in service. For detailed warranty, repair, and return information,
refer to the ADTRAN Equipment Warranty and Return Policy and Procedure.
Return Material Authorization (RMA) is required prior to returning equipment to ADTRAN. ADTRAN does not
recommend that repairs be performed in the field.
For service, RMA requests, or additional information, contact us using the following numbers:
ADTRAN Technical Support ............ (800) 726-8663
Standard Support Hours .............. Monday-Friday, 7 a.m.-7 p.m. CST
Emergency Support...................... 7 days/week, 24 hours/day
ADTRAN Sales ...................................(800) 827-0807
ADTRAN Repair/RMA ....................... (205) 963-8722
Repair and Return Address:
ADTRAN, Inc.
Customer Service Department
901 Explorer Boulevard
Huntsville, Alabama 35806-2807
61109.003L1-5A