ADC ICX-250 User manual

  • Hello! I am an AI chatbot trained to assist you with the ADC ICX-250 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
ADCP-62-023
Issue 1, September 1998
1027494
ICX
-250
User Manual
iv Front Matter
ADCP-62-023 Issue 1, September 1998
© 1998, ADC Telecommunications, Inc.
REVISION HISTORY
EDITION/ISSUE DATE REASON FOR CHANGE
Issue 1 09/98 Original.
LIST OF CHANGES
The technical changes incorporated into this issue are listed below.
PAGE IDENTIFIER DESCRIPTION OF CHANGE
New Manaul
TRADEMARK INFORMATION
ADC and ADC Telecommunications, are registered trademarks of ADC Telecommunications, Inc.,
ICX is a trademark of ADC Telecommunications, Inc., SLC-96 is a registered trademark of AT&T Technologies, Inc.,
Bellcore is trademark of Bellcore.
DISCLAIMER OF LIABILITY
Contents herein are current as of the date of publication. ADC reserves the right to change the contents without prior notice. In no event
shall ADC be liable for any damages resulting from loss of data, loss of use, or loss of profits and ADC further disclaims any and
all liability for indirect, incidental, special, consequential or other similar damages. This disclaimer of liability applies to all
products, publications and services during and after the warranty period.
This publication may be verified at any time by contacting ADC’s Technical Assistance Center at 1-800-366-3891, extension 3223 (in
U.S.A. or Canada) or 612-946-3223 (outside U.S.A. and Canada), or by writing to ADC Telecommunications, Inc., Attn: Technical
Assistance Center, Mail Station #77, P.O. Box 1101, Minneapolis, MN 55440-1101, U.S.A.
© 1998, ADC Telecommunications, Inc.
All Rights Reserved
Printed in U.S.A.
ADC Telecommunications, Inc.
P.O. Box 1101, Minneapolis, Minnesota 55440-1101
In U.S.A. and Canada: 1-800-366-3891
Outside U.S.A. and Canada: (612) 938-8080
Fax: (612) 946
-
3292
Front Matter v
Issue 1, September 1998 ADCP-62-023
© 1998, ADC Telecommunications, Inc.
TABLE OF CONTENTS
Content Page
IMPORTANT SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
INDUSTRY CANADA REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
FCC PART 15 INFORMATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .viii
FCC REGULATORY REQUIREMENTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .viii
UL APPROVED. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ix
CSA APPROVED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ix
UNPACKING THE ICX-250 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
WHO TO CALL FOR HELP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
PRODUCT OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
BENEFITS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
TR-08 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
ICX-250 SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
INSTALLING THE ICX-250 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
CHOOSING A SITE FOR THE ICX-250 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
RACK MOUNTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
LOCATING THE ICX-250 ON A DESKTOP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
WALL MOUNTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
THE ICX-250 UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
INTERNAL LAYOUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
INTERNAL DIP SWITCHES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
DIP SWITCH SETTINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
SETUP AND CONFIGURE THE ICX-250 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
SWITCHES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
FXS SUPERVISION TABLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
EXTERNAL DIP SWITCHES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
DIP SWITCH SETTINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
CONFIGURATION REFERENCE DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
CONNECTOR TYPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
CONNECTOR PINOUTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
POWER REQUIREMENTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
POWER INSTALLATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
ALARM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
GROUNDING REQUIREMENTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
CABLING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
TESTING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
SLIDE SWITCH SETTINGS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
T1 LOOPBACK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
DATA PORT 1 AND 2 LOOPBACK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
LED INDICATORS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
vi Front Matter
ADCP-62-023 Issue 1, September 1998
© 1998, ADC Telecommunications, Inc.
TABLE OF CONTENTS
Content Page
WARRANTY/SOFTWARE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
REPAIR/ADVANCE REPLACEMENT POLICY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
REPAIR CHARGES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
REPLACEMENT/SPARE PRODUCTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
RETURNED MATERIAL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
SYSTEM INTEGRATION SERVICES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
CUSTOMER SUPPORT SERVICES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Front Matter vii
Issue 1, September 1998 ADCP-62-023
© 1998, ADC Telecommunications, Inc.
IMPORTANT SAFETY INSTRUCTIONS
Read and follow all warning notices and instructions marked on the product or included in this guide.
1. This product is intended to be used with a three-wire grounding type plug. This is a safety feature.
Equipment grounding is vital to ensure safe operation. Do not defeat the purpose of the grounding
type plug by modifying the plug or using an adapter.
2. Prior to installation use an outlet tester or a voltmeter to check the AC receptacle for the presence of
earth ground. If the receptacle is not properly grounded, the installation must not continue until a
qualified electrician has corrected the problem. In addition, a connection for earth or safety grounding
is provided on the chassis. It is a #6 threaded stud located next to the AC inlet receptacle.
3. Slots and openings in the ICX-250 are provided for ventilation. To ensure reliable operation of the
product and to protect if from overheating, these slots and openings must not be blocked or covered.
4.
DO NOT
allow anything to rest on the power cord and do not locate the product where persons could
step or walk on the power cord.
5.
DO NOT
attempt to service this product yourself, as opening or removing covers may expose you
to dangerous high voltage points or other risks. Refer all servicing to qualified service personnel.
6. Special cables, which may be required by the regulatory inspection authority for the installation site,
are the responsibility of the customer.
7. When installed in the final configuration, the product must comply with the applicable Safety Standards
and regulatory requirements of the country in which it is installed. If necessary, consult with the
appropriate regulatory agencies and inspection authorities to ensure compliance.
8. A rare phenomenon can create a voltage potential between the earth grounds of two or more buildings.
If products installed in separate buildings are interconnected, the voltage potential may cause a
hazardous condition. Consult a qualified electrical consultant to determine whether or not this
phenomenon exists and, if necessary, implement corrective action prior to interconnecting the product.
INDUSTRY CANADA REQUIREMENTS
NOTICE:
The Canadian Industry Canada label identifies certified equipment. This certification
means that the equipment meets certain telecommunications network protective, operational and
safety requirements. The Department does not guarantee the equipment will operate to the user’s
satisfaction.
Before installing this equipment, users should ensure that it is permissible to be connected to the
facilities of the local telecommunications company. The equipment must also be installed using an
acceptable method of connection. In some cases, the company’s inside wiring associated with a
single line individual service may be extended by means of a certified connector assembly (tele-
phone extension cord). The customer should be aware that compliance with the above conditions
may not prevent degradation of service in some situations.
Repairs to the certified equipment should be made by an authorized Canadian maintenance facility
designated by the supplier. Any repairs or alterations made by the user to this equipment, or equip-
ment malfunctions, may give the telecommunications company cause to request the user to discon-
nect the equipment.
Users should ensure for their own protection that the electrical ground connections of the power
utility, telephone lines and internal metallic water pipe system, if present, are connected together.
This precaution may be particularly important in rural areas.
viii Front Matter
ADCP-62-023 Issue 1, September 1998
© 1998, ADC Telecommunications, Inc.
CAUTION:
Users should not attempt to make such connections themselves, but should contact
the appropriate electric inspection authority, or electrician, as appropriate.
The Ringer Equivalence Number (REN) assigned to each terminal device denotes the percentage
of the total load to be connected to a telephone loop which is used by the device, to prevent over-
loading. The termination on a loop may consist of any combination of devices subject only to the
requirement that the total REN of all the devices does not exceed 5. The RInger Equivalence Num-
ber of this unit is Not Applicable.
FCC PART 15 INFORMATION
This device has been tested and found to comply with FCC Part 15 “Class A” regulations for digi-
tal devices. Operation is subject to the following two conditions: (1) This device may not cause
harmful interference and (2) This device must accept any interference that may cause undesired
operation.
These FCC limits are designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy, and, if not installed and used in accordance with this User Manual,
may cause harmful interference to radio communications. Operation of this equipment in a resi-
dential area may cause harmful interference. If this happens, the user would be required to correct
the interference at his own expense.
FCC REGULATORY REQUIREMENTS
Notice to Users of T1 Service
The following instructions are provided to ensure compliance with the Federal Communications
Commission (FCC) Rules, Part 68. FCC Regulartory Number: 1H5USA-32637-DE-N.
1. Before connecting your unit, you must inform the telephone company of the following information:
2. If the unit appears to be malfunctioning, it should be disconnected from the telephone lines until you
learn if your equipment or the telephone line is the source of the trouble. If your equipment needs repair,
it should not be reconnected until it is repaired.
3. If the telephone company finds that this equipment is exceeding tolerable parameters, the telephone company
can temporarily disconnect service, although they will attempt to give you advance notice if possible.
4. Under the FCC Rules, no customer is authorized to repair this equipment. This restriction applies
regardless of whether the equipment is in or out of warranty.
Port ID REN/SOC FIC USOC
T1 Line 6.0N 04DU9-BN RJ48C / Dual Bantam Jacks
T1 Line 6.0N 04DU9-DN RJ48C / Dual Bantam Jacks
T1 Line 6.0N 04DU9-1KN RJ48C / Dual Bantam Jacks
T1 Line 6.0N 04DU9-1SN RJ48C / Dual Bantam Jacks
Front Matter ix
Issue 1, September 1998 ADCP-62-023
© 1998, ADC Telecommunications, Inc.
5. If the telephone company alters their equipment in a manner that will affect use of this device,
they must give you advance warning so as to give you the opportunity for uninterrupted service.
You will be advised of your right to file a complaint with the FCC.
6. An affidavit must be completed by the installer.
7. In the event of equipment malfunction, all repairs should be performed by our Company or an
authorized agent. It is the responsibility of users requiring service to report the need for service
to our Company or to one of our authorized agents.
UL APPROVED
The ICX-250 has been designed and tested in accordance with the requirements of UL1950.
CSA APPROVED
The ICX-250 has been designed and tested in accordance with the requirements of CSA C22.2
No. 950.
Welcome 1
Issue 1, September 1998 ADCP-62-023
© 1998, ADC Telecommunications, Inc.
CHAPTER 1
Welcome
This chapter introduces you to the features and benefits
of ICX-250.
Contents
Unpacking the ICX-250 . . . . . . . . . . . . . 2
Product Overview. . . . . . . . . . . . . . . . . . 3
2 Welcome Unpacking the ICX-250
ADCP-62-023 Issue 1, September 1998
© 1998, ADC Telecommunications, Inc.
Unpacking the ICX-250
This product is shipped as a complete package. Be very careful when
unpacking the carton. Check to see if all items are included in the box by
checking against the list shown below (Kit of Parts). In the event any items
are missing, contact your distributor for further instructions.
Opening Up the Carton
Keep all the packaging materials for future use in case the unit has to be
returned for maintenance and/or replacement.
Kit of Parts
• 2 Mounting brackets
• A 3-Conductor DC power plug
• A 2-Conductor alarm closure plug
• 6 6 x 5/16” self-tapping screws
• 4 12/24 x 1/2” screws
• 1 AC power cord
ICX-250 User Manual (this book)
The
ICX-250 User Manual
contains common tasks: configuration, installation,
maintenance, and testing of the unit
.
Hardware and Cabling
The ICX-250 unit comes packaged with an AC power cord to provide power
to the unit. It is also shipped with two angle brackets and screws to rack mount
your ICX-250
(this is explained further in Chapter 2 of this manual)
.
Who to Call for Help
Contact ADC Telecommunications if any items are missing or you want to order another ICX-250
unit. For technical support for your
ICX-250 unit call the BBG Technical Assistance Center at 1-800-
366-3891, extension 3223 (in U.S.A. or Canada) or 612-946-3223 (outside U.S.A. and Canada)
.
Product Overview Welcome 3
Issue 1, September 1998 ADCP-62-023
© 1998, ADC Telecommunications, Inc.
Product Overview
Bundled Service deployment is a snap thanks to the ICX-250 from ADC Telecommunications.
ADCs’ ICX-250 allows cost-effective and quick deployment of analog voice and data services on a
single T1 access trunk.
The ICX-250 sports a sleek, low profile chassis and is configured via DIP switches, eliminating the
need for PC based craft interface and specialized training. LEDs are provided for monitoring the
status of ICX-250 under normal operation as well as under test conditions. Maintenance and
diagnostics are further enhanced via loopbacks and test patterns, all configurable from the DIP
switches. Additionally, network loopbacks can be used to test from a remote office.
ICX-250 addresses access needs for sites requiring economical adaptation of FXS analog voice
based key systems and PBXs to T1 services. ICX-250 supports TR-08 as well as ESF and D4
framing. Additionally, ICX-250 provides two high speed EIA530A/V.35 ports for insertion of
Routers or other data traffic in bundled service arrangements. For sites needing up to 24 analog
lines, with or without data requirements, ADC’s ICX-250 is an ideal solution.
The ICX-250s primary function is to allow for remote termination of lines from a centrally-
located switch. Data ports are also provided on the unit for those applications where high speed
data deployment would be required.
The ICX-250 product is complimentary to the leading ICX-500 and Integrated Communications
Access server (ICX).
The ICX-250 from ADC Telecommunications - never before have bundled services been so
economical and easy to install and maintain.
Features
• Voice and data channel bank with integral CSU/DSX Interface
• Sleek, low profile, one rack unit (1 RU) chassis
• Choice of 12 or 24 FXS analog voice ports
• Two high speed EIA530A/V.35 data ports
• Extensive diagnostics
• LED status indicators for maintenance
• DIP switch configuration
• TR-08 support
Benefits
• Minimal Installation Costs - DIP switch based configuration simplifies
installation, eliminates need for a computer terminal, and reduces training costs.
• 1 RU design allows easy installation in tight spaces. Rack, wall or desktop
mounting options are available.
• Simplified Maintenance - manual test DIP switches, maintenance test and LED
status indicators, all simplify maintenance operations.
4 Welcome Product Overview
ADCP-62-023 Issue 1, September 1998
© 1998, ADC Telecommunications, Inc.
TR-08
The TR-TSY-000008 Bellcore
TM
standard (commonly referred to as TR-08) describes the generic
requirements for interfacing between local digital switches and remote digital terminals via the
SLC 96
TM
digital loop carrier system.
TR-08 has three operational modes (ICX-250 supports mode I):
• Modes I & III are non-concentrated and provide unique mapping between channel
numbers and DS1 time slots.
• Mode II is concentrated and there are no pre-determined relationships between the
channels and timeslots. This allocation of channels to time slots is made possible by the
exchange of messages between the Local Digital Switch (LDS) and remote terminal (RT).
Although commonly referred to as the TR-08 standard, the RT channel numbering scheme supported
by the ICX-250 unit is described in section 9.9 of the Bellcore publication TR-TSY-000057.
The ICX-250 provides SLC-96 Frame Format and Data Link.
When a T1 port is configured for TR-08 format, the voice channels assigned to this port are identified
by “channel number” (according to the TR-TSY-000008 document), which may be different from
the T1 time slot number. The ICX-250 supports only Group A. The relation between a channel number
and corresponding slot number for TR-08 is shown in the following table.
Channel Numbers123456789101112131415161718192021222324
Time Slots 135791113151719212324681012141618202224
Product Overview Welcome 5
Issue 1, September 1998 ADCP-62-023
© 1998, ADC Telecommunications, Inc.
ICX-250 Specifications
Chassis
Specification
Height
Width
Depth
Weight
1.75 inches (with feet 2 inches)
17.25 inches
12 inches
Approximately 10 pounds
Installation
Desktop
Wall Mount
Rackmount
Power Supply
Ring Generator
AC
DC
120V .6A Max. 60Hz (104 - 140 VAC)
–48V, –24V, or +24V 1.8A Max. (22.5 - 57 VDC)
Integrated AC/DC converter and Ringing Generator
Nominal 50 VRMS
Frequency 20 +/–1 Hz
DC component: –30 volts nominal
Crest factor cf, where 1.2=<cf=<1.6
Ringing Capability: 40 Vrms across 1 REN at the end of a 400 ohms loop.
Environment
Operating Temperature
Storage Temperature
Relative Humidity
0
0
C to 40
0
C
–40
0
C to 66
0
C
5 to 85% Humidity, Non-Condensing
Regulatory
Compliance
FCC Regulatory #
FCC Part 15 Class A
UL 1950 and CSA C22.2 950
FCC Part 68 and Industry Canada CS-03
1H5USA-32637-DE-N
Product Numbers
240212
240224
12 FXS ports, 2 EIA530A/V.35 data ports
24 FXS ports, 2 EIA530A/V.35 data ports
T1 Interface
Physical
Frame Format
Line Code
CSU Line Build Out
(LBO)
DSX Line Length
Clocking
FDL
One RJ48
D4, ESF, TR-08
AMI, B8ZS
0 dB, –7.5 dB, –15.0 dB
0.6 dB at 0-266 ft., 1.8 dB at 266 - 533 ft., 3.0 dB at 533 - 655 ft.
Internal Stratum 4, Line
Per ANSI T1.403 and AT&T TR62411
FXS Interface
Physical
FXS Supervision Mode
FXS Signaling
TLP
Impedance
Ringing Voltage
One 50-pin Female Amphenol
FXS, FXS-DN, FXS-DN-Wink, TR-08
Loop Start, Ground Start, Loop Start w/ forward Disconnect, Ground
Start Immediate, Ground Start Automatic, Universal Voice Grade,
Universal Voice Grade Automatic, Single-Party
–3 dB/–9 dB on Rx, + 3 dB/+9 dB on Tx
600 Ohm
50 Vrms
On hook transmission for Caller ID support
Data Interface
Physical
Data Rate
Two (2) EIA530A/V.35 ports (DB25)
Nx56K, Nx64K (N = 1 to 24)
Diagnostics
Extensive power-up self test
LED Indicators
QRSS Test Pattern on T1
2047 Test Pattern on Data ports
Loopbacks for FXS, T1 and Data ports
CSU Loopback detection
Performance statistics over FDL
Bantam jacks for in-session T1 monitoring and line testing
DIP Switch
Settings
FXS, T1, Data port Loopbacks, CSU Loopback Detection, Clocking,
T1 Frame Format, T1 Line Code, T1 Line Build Out, FXS TLP, FXS
Supervision, FXS Signaling, Trunk Conditioning, Test Patterns, Data rate.
System Basics 7
Issue 1, September 1998 ADCP-62-023
© 1998, ADC Telecommunications, Inc.
CHAPTER
2
System Basics
This chapter gives you quick, simple instructions to get you up
and running. You will also learn how to install and mount the
ICX-250 unit.
Contents
Installing the ICX-250. . . . . . . . . . . . . . . 8
The ICX-250 Unit . . . . . . . . . . . . . . . . . .13
8 System Basics Installing the ICX-250
ADCP-62-023 Issue 1, September 1998
© 1998, ADC Telecommunications, Inc.
Installing the ICX-250
The ICX-250 unit can be installed in a rack, on a desktop or attached to a
wall using appropriate wall anchors and brackets. It is necessary to read
the information that follows to ensure proper reliability of unit.
Choosing a Site for the ICX-250
When choosing a site for your ICX-250 unit make sure that the
instructions on installing the unit are followed. Provide adequate
ventilation and ample room for cable routing.
Temperature Specifications
Shipping and storage –40
o
C to +66
o
C
Operating temperature range 0
o
C to +40
o
C
Relative Humidity 5 to 85% Non-Condensing
Note:
The
ICX-250 is equipped with a fan to ensure
proper cooling and reliability. In the event that the
installation environment temperature exceeds the
standards above, it is recommended that adjustments
be made. Improper operation outside of these temperatures may
result in performance degradation.
Precautionary Procedures
There are several precautions to take before installing and/or servicing the
ICX-250 unit.
CAUTION
Never install telephone wiring during a lightning
storm.
Never install telephone jacks in wet locations unless the jack is
specifically designed for this purpose ONLY.
Never touch uninsulated telephone wires or terminals unless the
telephone line has been disconnected at the network interface.
Use CAUTION
when installing or modifying telephone lines.
Never attempt to service this product unless you are an
authorized service technician. Doing so can result in injury or
damage to the unit and void all warranties.
Installing the ICX-250 System Basics 9
Issue 1, September 1998 ADCP-62-023
© 1998, ADC Telecommunications, Inc.
Rack Mounting
The chassis comes with brackets for rack mounting. The installation site
for rack mounting should provide proper room for ventilation and cable
routing. Provide at least 2 inches of clearance between each ICX-250 unit
to allow for removal of the top if necessary for resetting of switches.
Check all grounding instructions when
installing the ICX-250 unit in a rack. Proper
grounding is mandatory at all times.
The following figure depicts a 19” rack mount configuration.
FXS Channel Status
Data Loop 2
Lcl. Off Net.
1 3 5 7 9 11 13 15 17 19 21 23
2 4 6 8 10 12 14 16 18 20 22 24
Center Mount
Flush Mount
10 System Basics Installing the ICX-250
ADCP-62-023 Issue 1, September 1998
© 1998, ADC Telecommunications, Inc.
The following figure depicts a 23” rack mount configuration.
!!
ATTENTION
!!
Set all options prior to installing
mounting brackets, top cover cannot be removed
once brackets are in place.
Installing the ICX-250 System Basics 11
Issue 1, September 1998 ADCP-62-023
© 1998, ADC Telecommunications, Inc.
Locating the ICX-250 on a Desktop
Each unit can be easily set on top of a desk or table. A stable environment
is necessary for peak performance of each unit.
11263-A
(Four)
Rubber Feet
Rubber feet are necessary for proper ventilation and air flow of the unit
when mounted on a flat surface. Removing them may damage the unit.
ICX-250
1357911131517192123
2 4 6 8 10 12 14 16 18 20 22 24
FXS Status Channel
T1 Status
T1 Loop
Test Pattern
Test Pattern
T1 Test
Self Check
ICX-250
1357911131517192123
2 4 6 8 10 12 14 16 18 20 22 24
FXS Status Channel
T1 Status
T1 Loop
Test Pattern
Test Pattern
T1 Test
Self Check
ICX-250
1357911131517192123
2 4 6 8 10 12 14 16 18 20 22 24
FXS Status Channel
T1 Status
T1 Loop
Test Pattern
Test Pattern
T1 Test
Self Check
DO NOT Remove Rubber Feet
12 System Basics Installing the ICX-250
ADCP-62-023 Issue 1, September 1998
© 1998, ADC Telecommunications, Inc.
Wall Mounting
Prior to wall mounting check to see if the environment is stable and free
from any extreme temperatures, humidity or vibrations of any sort. The
unit should be mounted with the fan to the top with at least 2 inches of
clear space on the sides, above, and below for adequate air flow. Allow at
least 6 inches for cable clearance and access to switches.
When attaching unit(s) to a wall make sure that appropriate fasteners such
as masonry anchors, heavy duty wood screws or expansion bolts are used
for heavy objects.
!!ATTENTION!!
Set all options prior to installing
mounting brackets, top cover cannot be removed
once brackets are in place.
Note:
Additional support hardware may be necessary
(not included with unit) to secure the unit properly to
the wall. If the surface is not solid enough to hold the
unit and attached cabling, it is recommended that a
small piece of 3/4” plywood be fastened to the wall before
attaching the unit. This will help ensure a more stable environment
.
ANGLE
BRACKET
Wall
The ICX-250 Unit System Basics 13
Issue 1, September 1998 ADCP-62-023
© 1998, ADC Telecommunications, Inc.
T
he ICX-250 Unit
The ICX-250 comes equipped with either 12 FXS (model 240212) or 24
FXS (model 240224) analog voice ports depending on which model you
purchase. Each unit is designed to allow easy accessibility to switches and
electrical connectors. The diagrams below illustrate the front and rear
layout of the unit. The diagram on the next page illustrates the internal
layout of the unit.
Note:
The 12 FXS or 24 FXS models are not field
upgradeable.
ICX-250 - Front Panel
ICX-250 - Rear Panel
ICX-250
1357911131517192123
2 4 6 8 10 12 14 16 18 20 22 24
FXS Status Channel
Data Loop 2
Lcl. / Off / Net.
Data Loop 1
Lcl. / Off / Net.
T1 Loop
Net. / Off / Lcl.
1 / Off / 2Off / QRSS
T1 Status
T1 Loop
Test Pattern
Test Pattern
T1 Test
Self Check
11261-A
120 VAC–.6A 60Hz
24/48 VDC
+ – G
T1
Rx
Tx
T1 Line
T1Data 2Data 2Data 11121324
Alm.
Data 1
FXS Loopback
FXS Loop Pairs
11264-A
25 PAIR AMPHENOL
CONNECTOR FOR 24
FXS TIP AND RING PAIRS
DIP SWITCHES TO SET
LOOPBACK FOR EACH
FXS CHANNEL
ALARM RELAY
FOR EXTERNAL
ALARM SYSTEM
TWO DB25 FEMALE
CONNECTORS FOR
DATA PORT 1 AND 2
SIGNALS
DIP SWITCHES USED FOR DATA
PORT 1 AND 2 CONFIGURATION
DIP SWITCHES
USED FOR T1
INTERFACE
CONFIGURATION
RJ48 CONNECTOR
FOR TRANSMIT AND
RECEIVE TIP AND
RING PAIRS
DUAL BANTAM
JACK
(MONITOR JACKS)
TERMINAL BLOCK FOR
DC POWER SUPPLY
EARTH GROUND
POWER INPUT FOR
120 VAC RECEPTACLE
14 System Basics The ICX-250 Unit
ADCP-62-023 Issue 1, September 1998
© 1998, ADC Telecommunications, Inc.
Internal Layout
12 FXS Analog Voice Ports
The illustration below shows the internal layout of the 12 FXS analog
voice port unit.
1 2 3 4 5 6 7 8
ON DIP
S7
1 2 3 4 5 6 7 8
ON DIP
S6
1 2 3 4 5 6 7 8
ON DIP
S14
1 2 3 4 5 6 7 8
ON DIP
S16
1 2 3 4 5 6 7 8
ON DIP
S15
S1
S2
S3
S4 S5
FRONT
BACK
FAN
/