GENERAL
INTRODUCTION
These instructions are for Baxter DPC1S
dehumidifying proofer. The DPC1S 40.5 inch deep
cabinet can be shipped assembled requiring minimal
field assembly. This cabinet can also be shipped
unassembled requiring field assembly. Both shipping
methods will require leveling and connection to
utilities. All utility connections are the responsibility of
the customer. All information, illustrations and
specifications contained in this manual are based on
the latest product information available at the time
indicated on the cover of the manual. Retain these
instructions for future reference.
UNPACKING
Remove crating from cabinet and check for possible
shipping damage. If cabinet is found to be damaged
after un-crating, save packaging material and contact
the carrier within 15 days of delivery. If location has
multiple cabinets, keep serial numbered crates
together. Check contents against packing list with
shipment. Refer to hardware list for identifying
hardware usage.
LOCATION
• Flooring:
Level floor within 1/8" per foot up to 3/4" in
all directions.
NOTE: For units supplied without a cabinet floor, the
equipment is to be installed on flooring materials that
are corrosion resistant and cleanable. Flooring
materials meeting these requirements may include
masonry materials. If a floor drain is located inside the
proofer, any exposed hardware should be constructed
of non-ferrous material.
• Drain connection:
1/2" FNPT (Female National Pipe Thread)
rear or front drain connection at 5" above
finished floor, route to air gap drain.
• Water connection:
Water and waste piping and connections
shall comply with the International Plumbing
Code 2003, International Code Council
(ICC), or to the Uniform Plumbing Code
2003, International Association of Plumbing
and Mechanical Officials (IAPMO).
NOTE: Plumbing connections must comply with
applicable sanitary, safety and plumbing codes and
provide adequate backflow protection to comply with
applicable federal, state and local codes.
• 3/4" MGHT (Male Garden Hose
Thread) water line connection at 95"
above finished floor. Connection to
solenoid requires 3/4" FGHT (Female
Garden Hose Thread); 3/4" FGHT - to
- 1/2" FNPT adaptor is provided.
• 30-80 psi flow.
• Cold water.
• Water Quality:
• Hardness 2-4 GPG. pH 7.0 to 8.0.
• Chloride concentration 0-30ppm.
• Sediment <.5 micron.
• Turbidity <.5NTU.
• Total dissolved solids <400ppm.
• The electrical diagram is located on the cover of
the component box. Cabinets require a single
phase or three phase 208-240 volt electrical
connection. Neutral wire circuitry needed to
provide 110-120 volt for miscellaneous control
components. A separate 110-120 volt line may
be run or a transformer option will be required if
110-120 volt is not available. Consult Bakery
Product Support for 110-120 volt line or
transformer option requirements.
• Single Phase (L1, L2, Neutral, Ground).
• Three Phase (L1, L2, L3, Neutral, Ground).
CLEARANCE DIMENSIONS
Cabinets UL/CSA Listed for 0" clearance for back and
side walls.
A 2" to 4" back clearance is recommended when
plumbing rear drain connection.
Top of cabinet requires a minimum of 24" clearance
for servicing accessibility.
Side wall(s) require a minimum of 1" clearance for
better performance if the DPC1S cabinet is installed
next to an oven.
DPC1S DEHUMIDIFYING PROOFING CABINET INSTALLATION INSTRUCTIONS - GENERAL
F45568 Rev. D (0923) Page 4 of 35