PLUMBING CONNECTIONS (PEQ Series Proofer only)
WARNING: PLUMBING CONNECTIONS MUST COMPLY WITH APPLICABLE SANITARY, SAFETY,
AND PLUMBING CODES.
Make sure the water supply has proper hardness and pH. The recommended water hardness range
is 4 – 6 grains per gallon. The recommended pH range is 6.5 to 8.0. Consult your local water company
and/or water conditioner dealer before installing a PEQ Series Proofer.
ELECTRICAL CONNECTIONS (Cord-Connected Roll-Ins) 120 Volts / 60 Hertz / 1 Phase Only
WARNING: THIS MACHINE IS PROVIDED WITH A THREE-PRONG GROUNDING PLUG. THE
OUTLET TO WHICH THIS PLUG IS CONNECTED MUST BE PROPERLY GROUNDED. IF THE
RECEPTACLE IS NOT THE PROPER GROUNDING TYPE, CONTACT AN ELECTRICIAN.
ELECTRICAL CONNECTIONS (Permanently Connected Roll-Ins)
WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH APPLICABLE
PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL
CODES.
WARNING: DISCONNECT THE ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE
DISCONNECT SWITCH TO INDICATE THAT YOU ARE WORKING ON THE CIRCUIT.
Refer to the wiring diagram supplied with the cabinet.
PRESTART CHECKS (Refrigeration Cabinets Only)
REFRIGERANT LINES — Check for tubing shifts due to shipping that would cause operating noise,
wear, or leaks.
DEFROST TIMER (Low Temperature Units and Convertible Models in Low Temperature Mode) —
When power is initially applied to the cabinet, the exterior dial of the defrost time clock (Fig. 5) must
be set to the correct time of day.
To access the defrost timer, remove the front
trim panel (Fig. 4) by lifting up and out. Open
door on the defrost timer box. Turn the inside
knob counterclockwise until the exterior dial is
positioned so the correct time of day is at the
time of day pointer. Replace the front trim
panel when done.
The defrost timer (Fig. 5) is set at the factory
for four 26-minute defrost cycles per day (2 AM,
8 AM, 2 PM, and 8 PM). Depending on local
conditions, it may be necessary to change the
frequency or duration of defrost cycles.
If the power supply is interrupted, the defrost
timer must be reset to the correct time of day. Fig. 8
PL-41397-1
TIME-OF-DAY POINTER
BEGIN DEFROST
END DEFROST
(26 MINUTES)
EXTERIOR DIAL (24 HOUR)
TURN KNOB
COUNTERCLOCKWISE
DEFROST CYCLE PINS