– 10 –
Denitions and Default Values for Proofer
/* P0 Software Version Number
/* P1 Fahrenheit or Celsius
/* P2 Temp Oset for Calib. Min. 0 Max. 40, 20 is zero oset
/* P3 Hum Oset for Calib. Min. 0 Max. 40, 20 is zero oset
/* P4 Minimum Temp for Proof 65°F
/* P5 Maximum Temp for Proof 115°F
/* P6 Minimum Humid for Proof 25%
/* P7 Maximum Humid for Proof 95%
/* P8 Recipe Lock 1 = Locked, 0 = Unlocked
/* P9 Preheat without humidity Preset T=105°F, Time out after 15 min. If Timer START/STOP button is not
pressed after 30 sec, the unit will go to Proof operation.
/* P10 Vent Fan Run Time 60 sec.
/* P11 Vent Open Time 60 sec.
/* P12 Hum Recheck Time 180 sec.
/* P13 Hi Humidity Vent % 3%
Default Parameter Values
0001 /* P0 Software Version Number
F /* P1 F=Fahrenheit, C=Celsius
20 /* P2 Temp Oset for Calib.
20 /* P3 Hum Oset for Calib.
65 /* P4 Minimum Temp for Proof
115 /* P5 Maximum Temp for Proof
25 /* P6 Minimum Humid for Proof
95 /* P7 Maximum Humid for Proof
1 /* P8 Recipe Lock 1=Locked 0=Unlocked
1 /* P9 Preheat 1= disabled, 0=enable
60 /* P10 Vent Fan Run Time (seconds)
60 /* P11 Vent Open Time (seconds)
180 /* P12 Hum Recheck Time (seconds)
3 /* P13 Hi Humidity Vent %