INSTALLATION INSTRUCTIONS & USER MANUAL
T210014 V1.00 FEB 2018 -ZIP HYDROCHILL 50
TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK
WWW.ZIPWATER.CO.UK
ZIP
HYDROCHILL
INSTALLATION INSTRUCTIONS & USER MANUAL
MODEL NUMBER:
HC50 range
High capacity chiller systems
2
INSTALLATION INSTRUCTIONS & USER MANUAL
T210014 V1.00 FEB 2018 -ZIP HYDROCHILL 50
TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK
WWW.ZIPWATER.CO.UK
TABLE OF CONTENTS
Precautions and recommendations ....................................................................... 3
Before installing the HydroChill ............................................................................. 5
Approvals............................................................................................................... 5
Product description ................................................................................................ 6
Explanation of product codes ................................................................................ 7
Water supply connection kit................................................................................... 8
Water supply connection detail , assembled ......................................................... 9
General CO
2
cylinder safety guidelines ................................................................ 10
Filter removal, replacement & ush ..................................................................... 11
Ultraviolet ltration ............................................................................................... 12
30 litre capacity models technical data, features and installation ........................ 13
60 litre capacity models technical data, features and installation ........................ 24
80-280 litre capacity models technical data, features and installation ................ 35
Sanitisation .......................................................................................................... 53
Maintenance & cleaning ...................................................................................... 53
Safeguarding the environment ............................................................................ 54
Warranty .............................................................................................................. 55
Contact details ..................................................................................................... 56
3
INSTALLATION INSTRUCTIONS & USER MANUAL
T210014 V1.00 FEB 2018 -ZIP HYDROCHILL 50
TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK
WWW.ZIPWATER.CO.UK
PRECAUTIONS AND GENERAL RECOMMENDATIONS
HydroChill is for internal use.
Keep away from water jets.
Always connect the HydroChill
to a water main that supplies
wholesome (cat 1) drinking water.
Before rst use, the HydroChill
must be sanitised by an
authorised technician.
After installation, ensure that the unit is not resting on the power cable.
Check that the unit is level and that it is resting on a surface with sufcient
load bearing capacity, in an environment that is suitable for its size and use.
Before any maintenance or cleaning operation is carried out, remove the
mains plug from the socket or disconnect the electrical power supply.
Ensure that the product is not sited close to sources of heat.
To guarantee adequate ventilation, leave at least 10cm clearance envelope of
space around the HydroChill.
Install the HydroChill in a clean, dry, well-ventilated environment. The
HydroChill is designed to function in environments with a temperature range
of between 5°C and 32°C - Climate Class N.
Take care not to damage the cooling uid circuit, it is lled with R290 gas
, which is highly ammable. It is essential to ensure that the tubes of the
refrigerant circuit are not damaged.
Ensure that it is possible to disconnect the electrical power supply either by
removing the mains plug or via a double pole isolation switch, with a contact
separation of at least 3mm in all poles.
The Appliance must be protected by an RCD or RCBO.
Check that the voltage shown on the rating plate corresponds to the
voltage being supplied at the installation site.
The HydroChill must not be cleaned with a water jet. Do not position other
electrical equipment in the immediate vicinity of the HydroChill.
Turn off the main water inlet isolation valve if the HydroChill is not to be used
for a long period.
Keep the areas surrounding the HydroChill dry, to avoid the risk of slipping.
CO
2
: You can have serious health problems if breathing air containing
concentrations of CO
2
up to 15000ppm (1.5%) for more than 10 minutes.
Proper ventilation must be provided to ensure that, in case of escape,
concentrations of CO
2
remain below this level.
If the supply cable is damaged, it must be replaced by a Zip service
technician or similarly qualied person in order to avoid a hazard.
Do not use extension leads or adapters.
This appliance is not intended to be used by persons (including children
!
4
INSTALLATION INSTRUCTIONS & USER MANUAL
T210014 V1.00 FEB 2018 -ZIP HYDROCHILL 50
TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK
WWW.ZIPWATER.CO.UK
PRECAUTIONS AND GENERAL RECOMMENDATIONS
aged from 8 years) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they are given
supervision or instruction concerning use of the appliance by a person
responsible for their safety.
Children should be supervised to ensure that they do not play with the
appliance.
The appliance is only to be installed in locations where it can be
overseen by trained personnel.
This equipment is to be installed in compliance with the local plumbing
regulations.
Water pipe connections and xtures directly connected to a wholesome
(cat 1) water supply shall be sized, installed, and maintained in
accordance with local regulations.
This manual is based on information available when approved for printing.
Continuing design renements could cause changes that may not be included
in it. Visit www.zipwater.co.uk
5
INSTALLATION INSTRUCTIONS & USER MANUAL
T210014 V1.00 FEB 2018 -ZIP HYDROCHILL 50
TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK
WWW.ZIPWATER.CO.UK
BEFORE INSTALLING THE HYDROCHILL
Congratulations for choosing a HydroChill.
We have designed and manufactured this product with great care to ensure
that it will dispense water of the highest quality.
In order to get the most out of your HydroChill, please read the instructions in
this manual and retain the manual for future reference.
APPROVALS
This HydroChill is designed, manufactured and marketed in compliance with:
The safety objectives of the Machinery Directive 2006/42/C.
The protection requirements of the Electromagnetic Compatibility Directive
2014/30/EU.
The electrical safety of the product is ensured only when it is properly connected
to an efcient, legally compliant grounding circuit.
6
INSTALLATION INSTRUCTIONS & USER MANUAL
T210014 V1.00 FEB 2018 -ZIP HYDROCHILL 50
TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK
WWW.ZIPWATER.CO.UK
PRODUCT DESCRIPTION
HydroChill — an under counter water
cooler with capacity options between 30 and
150 litres / hour.
The main features of the unit are as follows:
Modern design using strong materials.
Highly insulated ice-bank
Cooling serpentine coil made with AISI
grade 316 stainless steel for wholesome
water.
3 water options chilled, sparkling and
ambient water.
Body and internal fabrication parts made
entirely from stainless steel.
Professional dispensing taps made in 3
options.
Professional carbonator - stainless steel.
Easy opening for maintenance.
Capacity 80 to 280 litre models
Capacity 60 litre models
Capacity 30 litre models
7
INSTALLATION INSTRUCTIONS & USER MANUAL
T210014 V1.00 FEB 2018 -ZIP HYDROCHILL 50
TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK
WWW.ZIPWATER.CO.UK
PRODUCT CODES
Explanation of HydroChill range product code
HC HydroChill
Range
Product group
10 range
20 range
50 range
C Chilled only
* Chilled sparkling
*T* Dispensing tap
IT* Buttons
BIT Bridge
XX
HC X
XXX
XXX
Dispensing tap
2A 2 Tap
2P 2 Tap + badge
3A 3 Tap
3P 3 Tap + badge
** None
Control
Conguration
X
XX
U With UV
* Without UV
UV FILTRATION
Capacity (l)
30
60
80
150
280
Example
HC50CBITU280 Is a HC50, chilled only, bridge tap, with UV, 280 lire capacity.
* digit suppressed in product code.
8
INSTALLATION INSTRUCTIONS & USER MANUAL
T210014 V1.00 FEB 2018 -ZIP HYDROCHILL 50
TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK
WWW.ZIPWATER.CO.UK
WATER SUPPLY CONNECTIONS
Water supply connection kit
Line counter
Ø8mm - Ø1/4”
coupler
1/4” pipe
Ø8mm pipe
Filter head
1/4” stem elbow for tight
radius lter head connections
Water block
15mm to 1/2”
coupler
1/2” BSP - 1/4”
push t
WARNING (also see
precautions pages 3 & 4)
!
Connection to the mains water supply using the connection kit
To connect the HydroChill to the mains water supply, always use a new set of
connectors, pipes & ttings.
Mains water pressure limits, see Technical data pages 18,29,46.
Check that the mains pressure is between 2.5 bar and 3,5 bar.
To enhance the quality of the sparkling water dispensed, an incoming ow
rate in excess of 3.5 l/min is recommended.
If the water pressure is higher than 3,5 bar it is necessary to install a pressure
reducer.
Ø9.5mm pipe
(150-280 models)
Ø9.5mm - Ø1/4”
coupler
(150-280 models)
9
INSTALLATION INSTRUCTIONS & USER MANUAL
T210014 V1.00 FEB 2018 -ZIP HYDROCHILL 50
TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK
WWW.ZIPWATER.CO.UK
WATER SUPPLY CONNECTIONS
Water supply connection detail, assembled
Incoming cold
mains water
supply
Isolation valve
(not supplied)
Water block
15mm to 1/2”
coupler
1/2” BSP - 1/4”
push t
Filter head
Filter
(supplied)
Line counter
1/4” pipe
Ø8mm pipe
To HydroChill
Ø8mm - Ø1/4”
coupler
Ø9.5mm - Ø1/4”
coupler
(150-280 models)
Ø9.5mm
(150-280 models)
10
INSTALLATION INSTRUCTIONS & USER MANUAL
T210014 V1.00 FEB 2018 -ZIP HYDROCHILL 50
TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK
WWW.ZIPWATER.CO.UK
CO
2
(SPARKLING MODELS)
General CO
2
cylinder safety guidelines
1
2
3
4
5
1
Cap
2
Valve connection
3
Markings
4
Shoulder
5
Body
All of the cylinders must be tted with a
valve protector cap, which must be on tight
at all times when the cylinder is not in use.
The cylinders must be handled with care. It
is essential to avoid:
Clashes with other cylinders or surfaces;
dropping the cylinders; or
subjecting them to mechanical stress.
All of the above may compromise their
integrity and resistance.
The cylinders must not be lifted by the
cap, or dragged, rolled or slid along the
oor even if only being moved for short
distances.
An appropriate hand cart or other suitable
means of transport should be used.
Do not use magnetic lifters or slings with
rope.
!
WARNING (also see precautions
pages 3 & 4)
CO
2
connection (sparkling models)
CO
2
cylinder
(not supplied)
CO
2
regulator
Ø8mm pipe
To
HydroChill
11
INSTALLATION INSTRUCTIONS & USER MANUAL
T210014 V1.00 FEB 2018 -ZIP HYDROCHILL 50
TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK
WWW.ZIPWATER.CO.UK
FILTRATION
If the HydroChill is switched off for a long period of time
(e.g. more than a weekend), run water through the chilled
water outlet for at least 5 minutes before consumption.
Caution
Water will drip as the cartridge is removed.
Do not tilt the cartridge as water may spill from it if
tilted.
Isolate the water supply.
Unpack replacement cartridge and remove sanitary
cap, write today’s date where shown on the label.
Avoid touching the lter o-rings and lter opening as
this may cause bacterial contamination of the cartridge.
Align the front cartridge label to the left (as shown in
the “insert lter” diagram below), and push the new
cartridge up into the lter head.
Turn the cartridge a quarter turn anticlockwise until
it comes to a complete stop and locks, with the front
label facing forward.
Turn on the water supply.
Flush the lter by dispensing chilled or ambient water
for 5 mins.
When completed, clean up and dispose of old cartridge
and packaging.
Remove lter
Insert lter
Rotate
Insert
!
WARNING
!
Filter removal, replacement & ush
Rotate
Pull
12
INSTALLATION INSTRUCTIONS & USER MANUAL
T210014 V1.00 FEB 2018 -ZIP HYDROCHILL 50
TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK
WWW.ZIPWATER.CO.UK
ULTRAVIOLET (UV) FILTRATION
!
WARNING
The light emitted by the ultraviolet lamp may cause serious burns to the
eyes and skin.
Installation repair and maintenance shall only be reformed by personnel
qualied to work on UV products.
Sterilizing UV lter
Alongside the carbon lter, it is also possible to have your water cooler tted
with a UV-C (λ=254 nm) sterilizing lter on the dispensing point.
The UV-C light emitted by the special 4W mercury vapour lamp is lethal for all
micro-organisms (bacteria, viruses, mould, algae, etc.); for this reason, water
treated with the UV-C sterilizer will be micro-biologically pure.
Technical data
Material AISI 304 and quartz tube
Power rating 24V AC
Power consumption 4Wh
Maximum capacity of the lamp 9.000 h (max 12 months)
The UV sterilizer complies with European quality and safety guidelines.
13
INSTALLATION INSTRUCTIONS & USER MANUAL
T210014 V1.00 FEB 2018 -ZIP HYDROCHILL 50
TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK
WWW.ZIPWATER.CO.UK
30 LITRE CAPACITY MODELS -TECHNICAL DATA & INSTALLATION
Front of HydroChill 30 litre ................................................................................... 14
Rear of HydroChill 30 litre ................................................................................... 15
Rating plate ......................................................................................................... 16
Dimensions .......................................................................................................... 17
Technical data ..................................................................................................... 18
Installation ........................................................................................................... 19
Table of contents
14
INSTALLATION INSTRUCTIONS & USER MANUAL
T210014 V1.00 FEB 2018 -ZIP HYDROCHILL 50
TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK
WWW.ZIPWATER.CO.UK
30 LITRE - TECHNICAL FEATURES
Electrical power switch
1
2
3
Front of HydroChill
Electrical power cable connector
Adjustable thermostat
Ventilation conduit
4
1
2
3
4
15
INSTALLATION INSTRUCTIONS & USER MANUAL
T210014 V1.00 FEB 2018 -ZIP HYDROCHILL 50
TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK
WWW.ZIPWATER.CO.UK
30 LITRE - TECHNICAL FEATURES
Rear of HydroChill
7
1 2 3
4
6
5
1
2
3
4
5
6
7
Sparkling water outlet pipe tting Ø8mm
Ambient water outlet pipe tting Ø8mm
Chilled water outlet pipe tting Ø8mm
Carbonator safety valve
CO
2
inlet pipe tting Ø8mm
Wholesome (cat 1) water intlet pipe tting Ø8mm
Compensator (sparkling models)
16
INSTALLATION INSTRUCTIONS & USER MANUAL
T210014 V1.00 FEB 2018 -ZIP HYDROCHILL 50
TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK
WWW.ZIPWATER.CO.UK
30 LITRE - TECHNICAL FEATURES
Rating plate
Class N
Made in ItalySerial no.
PRODUCT
230V ~ 50 Hz KW A
RoHS
COMPLIANT
2011/65/EU
wholesome
water only
GAS g
Product identifying
part number
Supply voltage
Unique product
serial number
Refrigerant gas
type & weight
Conformity to EU product
directives
Power rating Current rating
Conformity to EU
environmental
directives
Climate class
Country of origin
Water supply
requirements
(situated on the back
of product)
17
INSTALLATION INSTRUCTIONS & USER MANUAL
T210014 V1.00 FEB 2018 -ZIP HYDROCHILL 50
TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK
WWW.ZIPWATER.CO.UK
30 LITRE - - DIMENSIONS
416
377
260
416
133
30 litre models
18
INSTALLATION INSTRUCTIONS & USER MANUAL
T210014 V1.00 FEB 2018 -ZIP HYDROCHILL 50
TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK
WWW.ZIPWATER.CO.UK
30 LITRE - TECHNICAL DATA
Technical Data Sheet HC 30
Cooling capacity, l/h 30
Continuous supply, l 6
Cold water temperature°C 5 - 12 *
Cooling technology Aluminium fusion block heat exchanger
Cold Water Coil Stainless Steel AISI 316
Pump Professional membrane carbonation pump
Condensation Ventilation
Adjustable thermostat Yes
Refrigerant gas R290
Electricity supply, V 230 - 50 Hz
Compressor power, HP 1/6
Power, W 210 W - 0.9 A
Inlet water Pipe, mm (”) Ø 8 (5/16)
Inlet CO
2
pipe, mm (”) Ø 8 (5/16)
Inlet water pressure, bar
(MPa)
2.5 bar (0.25) - 3.5 bar (0.35)
Dimensions WxDxH (mm) 260x416x416
Packaging dimensions
(WxDxH) mm
330x440x540
Net weight (kg) 25
Gross weight (kg) 27
* rated at a room temp. of 25°C and inlet water temp. of 20°C
19
INSTALLATION INSTRUCTIONS & USER MANUAL
T210014 V1.00 FEB 2018 -ZIP HYDROCHILL 50
TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK
WWW.ZIPWATER.CO.UK
30 LITRE - INSTALLATION
Unpacking
Remove the machine from the box and remove the inner packing.
In 30 model, the packaging can be
easily moved by the handles on the
two sides of the box (1).
Once you have unpacked the
HydroChill,ensure that it is not
damaged.
If the HydroChill has been shipped
horizontally or at an angle, it will be
necessary to wait at least 8 hours
before setting it up, in order to allow
the cooling circuit to reset itself.
Ensure that the unit is installed and
connected to the main supply by a
qualied technician in compliance with
the manufacturer’s instructions and
local safety guidelines.
Note there are no user serviceable part
inside the HydroChill.
1
20
INSTALLATION INSTRUCTIONS & USER MANUAL
T210014 V1.00 FEB 2018 -ZIP HYDROCHILL 50
TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK
WWW.ZIPWATER.CO.UK
30 LITRE - INSTALLATION
Siting the HydroChill
Wear safety gloves when handling the
HydroChill.
Site the HydroChill away from sources of
heat.
Ensure surface is level.
Leave at least 10cm around the unit to
allow for adequate ventilation.
Sanitise the HydroChill before rst use as
described on page 53.
Cut a hole (1) of 37x130mm on the
surface of the cabinet chosen for the
installation to allow the expulsion of hot air
from the cooling circuit.
Make sure the ventilation conduit (2) of
the unit aligns with the hole.
If it is not possible to drill the support
surface, remove the ventilation conduit
and make sure there is still 10 cm of
space around the HydroChill.
130mm
+
-
1
1
37mm
+
-
1
1
130mm
+
-
1
1
37mm
+
-
1
1
2
1
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56

Zip HydroChill 50 User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI