  • Hello! I am an AI chatbot trained to assist you with the APEC Water Systems RO-PUMP User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
APEC Booster Pumped R.O. SYSTEM:
Installation Addendum
How to install your RO-PUMP system:
The steps for installing the Booster Pumped RO system is the same as the included manual.
Please follow the direction in the Installation Manual from pages 1-12.
When you get to Step 6: “Connecting The System” in the manual (page 13), please use
this Addendum for “Summary of Tubing Connections”. Once tubing connections are
completed, proceed to page 14 - “Details on Tubing Connections”.
Step 6: Connecting The System
There are 4 connections:
Point A to X: Connect RO to COLD water supply — Red tubing.
Point G to Y: Connect product water from 5
th
-stage filter to tank — Yellow tubing*.
Point H to Z: Connect product water from 5
th
-stage output to dispensing faucet — Clear tubing.
Drain line to W: Connect waste water from 4
th
-stage membrane to the drain pipe — Black tubing.
* Note: The Yellow tubing is a 2-way line. Product water enters and leaves the tank via this
same line.
1
free drinking water.com
Fig. 10
Plug in Power after you have installed your system and
opened the feed water to the unit.
The Transformer and the Pump each has a “plastic connector piece”. Join these 2 pieces
together to connect the Transformer to the pump. Connect the Pump’s Transformer into an
electrical outlet. This will activate the Booster Pump on your system.
Fittings Type: All the fittings on the Booster-Pumped RO head are “Quick-Connect” type fittings. To
connect and remove tubing from ports, please see the diagrams below.
To Connect: Simply push the tubing into the Quick-Connect fitting tightly. NO inserts, sleeve,
or nuts are needed to secure the connection. No Teflon tape!
To Disconnect: Push in and hold down on the collet ring around the base of the fitting, then
pull out tubing.