Dell PowerSwitch Z9100-ON Owner's manual

Category
Network switches
Type
Owner's manual
Dell EMC PowerSwitch Z9100ON
Installation Guide
March 2021
March 2021
Rev. A06
Notes, cautions, and warnings
NOTE: A NOTE indicates important information that helps you make better use of your computer.
CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid
the problem.
WARNING: A WARNING indicates a potential for property damage, personal injury, or death.
© 2015 - 2021 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries.
Other trademarks may be trademarks of their respective owners.
Chapter 1: About this guide........................................................................................................... 5
Related documents............................................................................................................................................................. 5
Chapter 2: The Z9100ON switch.................................................................................................. 6
Introduction...........................................................................................................................................................................6
Features................................................................................................................................................................................. 7
Physical dimensions.............................................................................................................................................................7
LED display............................................................................................................................................................................ 7
LED behavior...................................................................................................................................................................8
Prerequisites....................................................................................................................................................................... 10
Z9100ON configurations................................................................................................................................................10
Switch status....................................................................................................................................................................... 11
Luggage tag......................................................................................................................................................................... 11
Chapter 3: Site preparations........................................................................................................ 12
Site selection.......................................................................................................................................................................12
Cabinet placement............................................................................................................................................................. 12
Rack mounting.................................................................................................................................................................... 13
Z9100ON ground............................................................................................................................................................. 13
Fans and airflow................................................................................................................................................................. 13
Power.................................................................................................................................................................................... 13
Storing components.......................................................................................................................................................... 13
Chapter 4: NEBS compliance....................................................................................................... 15
Important information....................................................................................................................................................... 15
NEBS-compliant ground installation..............................................................................................................................15
Chapter 5: Z9100ON installation................................................................................................ 18
Unpack..................................................................................................................................................................................18
Ground cable....................................................................................................................................................................... 18
Rack or cabinet installation..............................................................................................................................................19
ReadyRails installation................................................................................................................................................ 20
Two-post flush-mount configuration..................................................................................................................... 20
Two-post center-mount configuration................................................................................................................... 21
Four-post threaded configuration........................................................................................................................... 22
Z9100-ON switch installation......................................................................................................................................... 23
1U front-rack installation........................................................................................................................................... 23
Optics installation..............................................................................................................................................................25
Optics removal............................................................................................................................................................. 25
Port connectivity...............................................................................................................................................................25
Switch power up................................................................................................................................................................26
After Z9100ON installation...........................................................................................................................................26
Switch replacement..........................................................................................................................................................26
Contents
Contents 3
Chapter 6: Power supplies...........................................................................................................28
Components....................................................................................................................................................................... 28
AC or DC power supply installation...............................................................................................................................29
DC power supply connection....................................................................................................................................29
AC or DC power supply replacement............................................................................................................................ 31
Chapter 7: Fans........................................................................................................................... 32
Components....................................................................................................................................................................... 32
Fan module installation.....................................................................................................................................................33
Fan module replacement................................................................................................................................................. 33
Fan air filter replacement................................................................................................................................................ 33
Chapter 8: Management ports..................................................................................................... 35
RS-232 console port access...........................................................................................................................................35
MicroUSB-B console port access................................................................................................................................. 36
USB storage....................................................................................................................................................................... 36
Before you install an OS...................................................................................................................................................37
Switch check...................................................................................................................................................................... 38
Chapter 9: Specifications............................................................................................................ 39
Switch physical design.....................................................................................................................................................39
IEEE standards...................................................................................................................................................................40
Agency compliance........................................................................................................................................................... 40
USA Federal Communications Commission statement............................................................................................ 40
European Union EMC Directive Conformance statement....................................................................................... 41
Japan VCCI Compliance for Class A Equipment........................................................................................................42
Korean certification of compliance............................................................................................................................... 42
Safety Standards and Compliance Agency certifications........................................................................................43
Electromagnetic Compatibility ...................................................................................................................................... 43
Product recycling and disposal...................................................................................................................................... 44
Chapter 10: Dell EMC support......................................................................................................45
4
Contents
About this guide
This guide provides site preparation recommendations, step-by-step procedures for rack mounting and desk mounting, inserting
optional modules, and connecting to a power source.
CAUTION: To avoid electrostatic discharge (ESD) damage, wear grounding wrist straps when handling this
equipment.
NOTE: Only trained and qualified personnel can install this equipment. Read this guide before you install and power up this
equipment. This equipment contains two power cords. Disconnect both power cords before servicing.
NOTE: This equipment contains optical transceivers, which comply with the limits of Class 1 laser radiation.
Figure 1. Class 1 laser product tag
NOTE: When no cable is connected, visible and invisible laser radiation may be emitted from the aperture of the optical
transceiver ports. Avoid exposure to laser radiation and do not stare into open apertures.
Regulatory
Regulatory Model No. Z9100
Marketing Model No. Z9100
Topics:
Related documents
Related documents
For more information about the Z9100ON switch, see the following documents:
Dell Networking Getting Started Guide for the Z9100Open Networking (ON) System
Dell Networking Release Notes for the Z9100Open Networking (ON) System
Dell Networking Command Line Reference Guide for the Z9100Open Networking (ON) System
Dell Networking Configuration Guide for the Z9100Open Networking (ON) System
Open Networking Hardware Diagnostic Guide for the Z9100ON System
NOTE: For the most recent documentation, visit Dell EMC support: www.dell.com/support.
1
About this guide 5
The Z9100ON switch
The following sections describe the Dell EMC Z9100ON switch:
Topics:
Introduction
Features
Physical dimensions
LED display
Prerequisites
Z9100ON configurations
Switch status
Luggage tag
Introduction
The Z9100-ON is a one rack unit compact 10/25/40/50/100 GbE switch. The switch includes 32 fixed quad form-factor
pluggable 28 (QSFP28) optics for 40/100 GbE aggregation and 10/25/40/50 GbE top-of-rack (ToR) and end-of-row (EoR)
applications. The Z9100ON switch includes two hot-swap AC or DC power supply units (PSUs) and five hot-swap fan units.
Figure 2. Z9100ON I/O-side view
1.
MicroUSB-B console port 2. RS-232/RJ45 serial console port
3. Thirtytwo 10/25/40/50/100 QSFP28 ports 4. 1000M/10G SFP+ ports
5. Stack ID 6. USB Type A storage
7. 10/100/1000BaseT Ethernet management port 8. Luggage tag
2
6 The Z9100ON switch
Figure 3. Z9100ON PSU-side view
1. Fan modules
2. Power supply units
Features
The Z9100ON offers the following features.
QSFP ports support 10/25/40/50/100 GbE
Two 1000M/10G SFP+ ports
One micro universal serial bus (MicroUSB-B) console port
One 2.0 USB Type-A port for additional file storage
One 10/100/1000BaseT Ethernet management port
Rangeley central processing unit (CPU) system with 8GB DDR III RAM.
Temperature monitoring
Software-readable thermal monitor
Real time clock (RTC) support
Two hot-pluggable redundant power supplies
Power management monitoring
Five removable fans
Standard 1U chassis
Physical dimensions
The Z9100-ON has the following physical dimensions:
434 x 462 x 44 mm (W x D x H)
17.1 x 18.2 x 1.72 inches (W x D x H)
Handle: 40 mm (1.57 inches)
LED display
The Z9100ON includes LED displays on the I/O side of the switch. This section describes open networking installation
environment (ONIE) LED behaviors. Some LED behaviors may change after you install your software.
NOTE:
If you are installing third-party software, for LED information, see your third-party operating software
documentation.
The Z9100ON switch 7
LED behavior
The following Z9100ON switch LED behavior is seen during open networking installation environment (ONIE) operations:
Figure 4. Z9100ON LEDs
1. Master LED 2. Switch LED
3. Locator LED 4. QSFP28 LED
5. SFP+ LED 6. Stack ID
7. SFP+ LED 8. RJ45 Ethernet Management Port LEDs
9. Fan LED 10. Power LED
Table 1. Z9100ON LED behavior
LED Description
Master LED
OffSwitch is in Stacking Slave mode.
Solid GreenSwitch is in Stacking Master or Standalone
mode.
Switch LED
OffNo power.
Solid GreenNormal.
Blinking GreenPOST is in process.
Solid amberMajor system error.
Blinking amberMinor system alert.
Locator LED
OffLocator is idle.
Blinking blueLocator is functioning.
SFP+ LED
OffNo link.
Solid greenLink is active.
Flashing greenport activity.
RJ45 Ethernet Port LEDs
OffNo link.
Solid greenLink on maximum speed, 1 Gbps speed.
Solid amberLink on lower speed, 10/100 Mbps speeds.
Flashing greenPort activity.
Stacking ID
Stack unit number.
Management Port LED
OffNo link or activity.
Solid greenPort link on maximum speed.
Solid amberPort link on lower speed.
Flashing greenPort activity.
8 The Z9100ON switch
Table 1. Z9100ON LED behavior (continued)
LED Description
Fan LED
OffNo powe.r
Solid greenFan powered and running at the expected
RPM.
Flashing amberFan failed or incompatible airflow
direction, PSU or fan trays with differing airflows.
Power LED
OffNo power.
Solid greenNormal operation.
Solid amberPOST in progress.
Blinking amberNoncritical system error; PSU fan failure
or power supply failure.
Table 2. QSFP28 port LEDs
LED Description
Link LED
OffNo link.
Solid greenPort activity operating at maximum port
speed.
Solid amberPort activity operating at lower speed.
Activity LED
OffNo link.
Flashing green, ~30 msPort activity operating at
maximum port speed.
Flashing amber, ~30 msPort activity operating at lower
port speed.
Table 3. QSFP28 port LEDs for 4x25 GbE or 4x10 GbE mode
LED Description
Link LED
OffNo link.
Solid greenPort link is 4x25 GbE.
Solid amberPort link is 4x10 GbE.
Activity LED
OffNo link
Flashing green, ~30 msPort link is 4x25 GbE.
Flashing amber, ~30 msPort link is 4x10 GbE.
Table 4. QSFP28 port LEDs for 2x50 GbE mode
LED Description
Link LED
OffNo link.
Solid greenPort link is 2x50 GbE.
Activity LED
OffNo link
Flashing amber, ~30 msPort link is 2x50 GbE.
Table 5. SFP+ port LEDs
LED Description
Link LED
OffNo link.
Solid greenLink operating at maximum port speed.
Solid amberLink operating at lower speed.
Activity LED
OffNo link.
Flashing green, ~30 msport activity.
Flashing amber, ~30 msport activity.
The Z9100ON switch 9
Prerequisites
The following is a list of components needed for successful installation of the Z9100-ON:
NOTE: Detailed installation instructions for the Z9100-ON are provided in Site Preparations and Install the Z9100-ON.
Z9100ON switch, or multiple switches if stacking
AC or DC country- and regional-specific cables. Used to connect the AC or DC power source to each of the switches AC or
DC power supplies.
ReadyRail mounting brackets for rack installation, included
Screws for rack installation
#1 and #2 Phillips screwdrivers, not included
Ground cable screws for L-bracket, included
Copper and fiber cables
Other components are:
Ground cable screw, M3 or M4 depending on your switch
Extra mounting brackets
Z9100ON configurations
You can order the Z9100ON switch in several configurations.
You can order the following supported hardware components:
Z9100ON AC or DC normal airflow: thirtytwo 10/25/40/50/100 GbE ports with two SFP+ 10 GbE ports, two AC or DC
power supply and five fan subsystems. Airflow is from the I/O side to the power supply side.
Z9100ON AC or DC reverse airflow: thirtytwo 10/25/40/50/100 GbE ports with two SFP+ 10 GbE ports, two AC or DC
power supply and five fan subsystems. Airflow from the power supply side to the I/O side.
Fan with airflow from the I/O side to the PSU sidenormal airflow
Fan with airflow from the PSU side to the I/O sidereverse airflow
AC or DC power supply with airflow from the I/O side to the PSU sidenormal airflow
AC or DC power supply with airflow from the PSU side to the I/O sidereverse airflow
10
The Z9100ON switch
Switch status
You can view Z9100ON status information using the light emitting diodes (LEDs).
Luggage tag
The Z9100ON switch has a pull-out tag, known as a luggage tag, on the I/O-side of the switch. The luggage tag includes
switch ID information.
Figure 5. Z9100ON luggage tag
1.
Service tag 2. PPID
3. MAC address 4. Express service code
The Z9100ON switch 11
Site preparations
The Z9100ON is suitable for installation as part of a common bond network (CBN).
You can install the switch in:
Network telecommunication facilities
Data centers
Other locations where the National Electric Code (NEC) applies
For more information about Z9100ON specifications, see Specifications.
NOTE: Install the Z9100ON switch into a rack or cabinet before installing the components.
Topics:
Site selection
Cabinet placement
Rack mounting
Z9100ON ground
Fans and airflow
Power
Storing components
Site selection
Install Dell EMC equipment in restricted access areas.
A restricted access area is one in which service personnel can only gain access using a special tool, lock, key or other means of
security. The authority responsible for the location must control the site access.
Ensure that the area where you install your Z9100ON switch meets the following safety requirements:
Near an adequate power source. Connect the switch to the appropriate branch circuit protection as defined by your local
electrical codes.
Environmentalswitch locationtemperature range is from 32° to 113°F (from 0° to 45°C).
Ambientswitch operatingtemperature range is from 10° to 35°C (from 50° to 95°F).
Relative humidity is from 5 to 85 percent noncondensing.
In a dry, clean, well-ventilated, and temperature-controlled room, away from heat sources such as hot air vents or direct
sunlight.
Away from sources of severe electromagnetic noise.
Positioned in a rack or cabinet, or on a desktop with adequate space in the front, back, and sides for proper ventilation and
access.
Install the switch in information technology rooms in accordance with Article 645 of the National Electrical Code and NFPA
75.
Cabinet placement
Install the Z9100ON only in indoor cabinets designed for use in a controlled environment.
Do not install the Z9100ON in outside cabinets. For cabinet placement requirements, see Site Selection.
The cabinet must meet minimum size requirements. Airflow must be in accordance with the Electronic Industries Alliance (EIA)
standard. Ensure that there is a minimum of 5 inches (12.7 cm) between the intake and exhaust vents and the cabinet wall.
3
12 Site preparations
Rack mounting
When you prepare your equipment rack, ensure that the rack is grounded.
Ground the equipment rack to the same ground point the power service in your area uses. The ground path must be permanent.
Z9100ON ground
Dell EMC recommends you ground the Z9100-ON switch. Use your switch in a common bond network (CBN).
Connect the grounding cables as described in Z9100-ON Installation.
Fans and airflow
The Z9100ON fans support two airflow options: normal and reverse. Normal airflow is from the I/O side to the PSU side.
Reverse airflow from the PSU side to the I/O side.
Fan combinations
Installation of the fans is done as part of the factory install based on SKU type. The Z9100-ON has stock keeping units (SKUs)
that support the following configurations:
AC or DC PSU with fan airflow from the I/O to the PSUnormal airflow
AC or DC PSU with fan airflow from the PSU to the I/Oreverse airflow
Be sure to order the fans suitable to support your sites ventilation. Use a single type of airflow fan in your switch. Do not mix
reverse and normal airflows in a single Z9100ON switch.
For proper ventilation, position the Z9100-ON in an equipment rack or cabinet with a minimum of 5 inches (12.7 cm) of
clearance around the exhaust vents.
Power
To connect the switch to the applicable power source, use the appropriate power cable. A power cable is included with the
switch.
When installing AC or DC switches, follow the requirements of the National Electrical Code, ANSI/NFPA 70, where applicable.
The switch powers-up when you connect the power cable between the switch and the power source.
CAUTION: Always disconnect the power cable before you service the power supply slots.
CAUTION: On an AC switch, use the power supply cable as the main disconnect device. Ensure that the socket-
outlet is located and installed near the equipment and is easily accessible.
NOTE: Module power is software controlled. You do not see module LEDs when the switch powers up in ONIE.
Storing components
If you do not install your Z9100ON and components immediately, Dell EMC recommends properly storing the switch and all
optional components by following these guidelines:
Storage location temperature must remain constant. The storage range is from -40°C to 70°C (-40° to 158°F).
Store on a dry surface or floor, away from direct sunlight, heat, and air conditioning ducts.
Store in a dust-free environment.
Site preparations
13
NOTE: ESD damage can occur when components are mishandled. Always wear an ESD-preventive wrist or heel ground
strap when handling the Z9100ON and its accessories. After you remove the original packaging, place the Z9100ON and
its components on an antistatic surface.
14 Site preparations
NEBS compliance
For your switch to be network equipment building system (NEBS) compliant, you must follow the instructions detailed in this
section.
To be NEBS compliant, orient your switch in the rack so that the air inlet is from the front aisle and the air exhaust is to the
back aisle.
Topics:
Important information
NEBS-compliant ground installation
Important information
WARNING: The SFP+, QSFP, QSFP28, console, Ethernet management, and universal serial bus (USB) ports
are suitable for connection to intrabuilding or unexposed wiring or cabling only. You MUST NOT metallically
connect the ports to interfaces that connect to the out side plant (OSP) or its wiring. Use these interfaces as
intrabuilding interfaces only (Type-2 or Type-4 ports as described in GR-1089-CORE, Issue 6) and they require
isolation from the exposed OSP cabling. Adding primary protectors is not sufficient protection to connect these
interfaces metallically to OSP wiring.
WARNING: If you install and connect the Z9100-ON switch to a commercial AC power source, you must connect
the switch to an external special protection device (SPD).
To be NEBs compliant:
Locate your switch in a restricted-access area were only trained personnel are allowed access.
Install and connect your switch to the common bonding network (CBN).
You can also install and connect your switch to the central office.
Connect the battery returns of your switch as DC-I.
Ground your switch using a copper ground conductor.
Clean and coat all bare grounding connection points on your switch with an anti-oxidant solution before making connections.
Bring all unplated surfaces on your switch to a bright finish and treat them with an anti-oxidant solution before making
connections.
To ensure electrical continuity, remove any nonconductive surfaces on your switch from the threads and connection points.
Use the two-hole, Listed, compression-type lug with an AWG 14 gauge wire for switch grounding.
NOTE: The Z9100-ON can operate at -40.5 VDC to -60 VDC at a maximum current level of 15A.
NOTE: The Z9100-ON is Earthquake Z4-compliant when you attach the ReadyRails to the four-post frame using threaded
hardware. Do not use the tool-less or two-post installation methods.
NEBS-compliant ground installation
Before you install the switch into a rack, install the ground (GND) lug assembly.
Your switch includes two installed M3 screws on the lower-left side of your switch. Your switch also includes an assembled
UL-certified GND lug with bracket, packaged separately. If any parts are missing, contact your Dell EMC sales representative.
4
NEBS compliance 15
Figure 6. GND lug assembly
1. Remove the two installed M3 screws from the lower-left side of your switch.
NOTE: Keep these screws.
2. Remove the bracket assembly from the shipping bag.
3. Clean the bracket and lug surfaces thoroughly, and apply an anti-oxidant solution to the mating surfaces.
4. Attach the switch ground using the Ground cable instructions.
5. Using the two removed screws, attach the GND lug bracket assembly to your switch, as shown.
Torque the M3 screws to ±45 in-lbs.
Figure 7. Attach GND lug assembly
16
NEBS compliance
Figure 8. GND lug assembly attached
6. Install your switch into your rack using the Z9100-ON Installation instructions.
NEBS compliance 17
Z9100ON installation
To install the Z9100ON switch, complete the installation procedures in the order described.
Always handle the Z9100ON and its components with care. Avoid dropping the switch or its field replaceable units (FRUs).
NOTE: ESD damage can occur if components are mishandled. Always wear an ESD-preventive wrist or heel ground strap
when handling the Z9100ON and its components. As with all electrical devices of this type, take all the necessary safety
precautions to prevent injury when installing this switch.
NOTE: For more information, see the Open Networking Hardware Diagnostic Guide for the Z9100ON System.
Topics:
Unpack
Ground cable
Rack or cabinet installation
Z9100-ON switch installation
Optics installation
Port connectivity
Switch power up
After Z9100ON installation
Switch replacement
Unpack
NOTE: Before unpacking the switch, inspect the container and immediately report any evidence of damage.
When unpacking the Z9100-ON switch, ensure that the following items are included:
One Z9100-ON switch
One RJ-45 to DB-9 female cable
Two sets of rail kits, no tools needed
Two PSUs
Five fan units
Two country- and region-specific AC or DC power cables
Dell Networking Getting Started Guide for the Z9100Open Networking (ON) System
Safety and Regulatory Information
Warranty and Support Information
Ground cable
NOTE:
For AC-powered switches, although the third conductor of the AC power cord provides a ground path, Dell EMC
recommends grounding your switch with a dedicated ground wire.
NOTE: For DC-powered switches, the only way to safely ground your switch is to attach a dedicated ground wire.
Depending on the type of switch, to attach a ground cable to the switch, you need one of the included M3 or M4 screws. The
switch ships with one of the following two configurations:
One threaded hole using an included M3 screw.
Two threaded holes using one of the two included M4 screws.
5
18 Z9100ON installation
In both configurations, the ground cable is not included. To properly ground the switch, Dell EMC recommends a one- or
two-hole lug, M3 or M4 hole size. The switch hole lugs must be a UL-recognized, crimp-type lug.
CAUTION: Grounding conductors
must
be made of copper. Do not use aluminum conductors.
NOTE: Coat the one-hole lug with an anti-oxidant compound before crimping. Also, bring any unplated mating surfaces
to a bright finish and coat with an anti-oxidant before mating. Plated mating surfaces must be clean and free from
contamination.
NOTE: The rack installation ears are not suitable for grounding.
To connect the ground cable to the switch, follow these steps:
1. Remove the ground cable from the shipping bag and cut it to the desired length. The cable length must facilitate proper
operation of the fault interrupt circuits. Use the shortest cable route allowable.
2. Use one of the following to attach the ground cable:
Using one threaded M3 hole, attached the ground cable to the lug using an M3 screw with a captive internal tooth lock
washer, as shown. Torque the screw to ±45 in-lbs.
Using one of the two M4 threaded holes, attach the ground cable to the lug. Use an M4 screw with a captive internal
tooth lock washer, as shown. Torque the screw to ±56 in-lbs.
3. Attach the other end of the ground cable to a suitable ground point such as the rack or cabinet.
The rack installation ears are not a suitable grounding point.
Rack or cabinet installation
You may either place the switch on a rack shelf or mount the switch directly into a 19" wide, EIA-310- E-compliant rack.
Compliant racks include four-post, two-post, or threaded. The ReadyRails system is provided for 1U front-rack and two-post
installations.
The ReadyRails system includes separately packaged rail assemblies.
CAUTION:
Your switch is not NEBS Earthquake Z4-compliant if you use the 1U tool-less square-hole or two-post
installation methods.
WARNING: This guide is a condensed reference. Read the safety instructions in your Safety, Environmental, and
Regulatory information booklet before you begin.
NOTE: The illustrations in this document are not intended to represent a specific switch.
NOTE: Do not the use the mounted ReadyRails as a shelf or a workplace.
Rack mount safety considerations
Rack loadingOverloading or uneven loading of racks may result in shelf or rack failure and can damage the equipment and
possible personal injury. Stabilize racks in a permanent location before loading begins. Mount the components starting at the
bottom of the rack, then work to the top. Do not exceed your racks load rating.
Power considerationsConnect only to the power source specified on the unit. When multiple electrical components are
installed in a rack, ensure that the total component power ratings do not exceed the circuit capabilities. Overloaded power
sources and extension cables present fire and shock hazards.
Elevated ambient temperatureIf installed in a closed rack assembly, the operating temperature of the rack environment
may be greater than the room ambient temperature. Use care not to exceed the 45°C (113°F) maximum ambient
temperature of the switch.
Reduced airflowDo not compromise the amount of airflow required for safe operation of the equipment. Install the
equipment in the rack so that the equipment constantly has the correct amount of airflow surrounding it.
Reliable earthingMaintain reliable earthing of rack-mounted equipment. Pay particular attention to the supply connections
other than the direct connections to the branch circuit, for example: use of power strips.
Do not mount the equipment with the back panel facing downward.
Z9100ON installation
19
ReadyRails installation
The ReadyRails rack mounting system is provided to easily configure your rack for installation of your Z9100ON switch.
You can install the ReadyRails system using the 1U tool-less method or one of three possible 1U tooled methods. The tooled
installation methods include two-post flush mount, two-post center mount, or four-post threaded.
CAUTION: Do not use this method if you need your switch to be NEBS Earthquake Z4-compliant.
1. Face the ReadyRails flange ears facing outward. Place one rail between the left and right vertical posts. Align and seat the
back flange rail pegs in the back vertical post flange.
The center extraction shows the pegs in both the square and nonthreaded round holes.
Figure 9. 1U tool-less configuration
2. Align and seat the front flange pegs in the holes on the front side of the vertical post.
3. Repeat this procedure for the second rail.
To remove each rail, pull on the latch release button on each flange ear and unseat each rail.
Two-post flush-mount configuration
CAUTION: Your switch is not NEBS Earthquake Z4-compliant if you use this installation method.
1. Remove the latch castings from the front side of each ReadyRails assembly, item 1.
To remove the two screws from each front flange ear on the switch side of the rail and remove each latch casting, use
a torx screwdriver. Retain the latch castings for future rack requirements. It is not necessary to remove the back flange
castings.
20
Z9100ON installation
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45

Dell PowerSwitch Z9100-ON Owner's manual

Category
Network switches
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI