Danfoss SpeedUp - Strongboard Carpet User guide

  • Hello! I am an AI chatbot trained to assist you with the Danfoss SpeedUp - Strongboard Carpet User guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Application sheet
SpeedUp
Carpet
Strongboard carpet
1
2
3
4
5
1 Carpet ≥ 5 mm
2 Strongboard carpet 10 mm
3 SpeedUp heat panel + FH composite pipe 30 mm
4 Support batten (30mm)
5 Additional insulation EPS 035 DEO 20 mm
6 SpeedUp perimeter insulation
7 If necessary moisture barrier
Floor nish ≥ 5 mm Carpet
Construction height ≥ 65 mm Height including oor nish
Weight ~ 18 kg / m² Weight including oor nish
Thermal resistance R 1,43 m²K / W The minimum thermal resistance requirement of DIN EN 1264 is
fullled. For water table ≤ 5 m the R-value must be increased.
Thermal transmission coecient U 0,63 W / m²K In renovations and building extensions up to 50 m² U-value = 0.5
W/m²K must be maintained. Always follow the planning data.
Design load ≤ 2,0 kN / m²
Point load (≥ 20 cm²) ≤ 2,0 kN Sum point load ≤ design load; please notice special heavy ob-
jects (aquaria etc.)
Impact subsonic noise reduction NA dB
Application area
Residential spaces, hallways and attic spaces in residential buildings and hotel rooms.
Corresponds to categories A1, A2 and A3 of DIN 1055-3. Oce spaces, hallways in oce
buildings, medical oces, stations and spaces with human occupancy, and commercial
spaces with oor areas up to 50 m² in residential or oce buildings. Corresponds to
categories B1, D1 and D2 of DIN 1055-3.
Requirements & special features
A level, smooth and structurally sound surface is necessary for full surface contact with
the heating elements (elevated requirements according to DIN 18202 Table 3, row 4).
Structural sealing according to DIN 18195 must be placed beneath the oor panel in
case of structures facing the ground, and otherwise on the unnished oor. Supply /
return panels and cut panels (insulation panels or SpeedUp panels) must be glued to
the substrate and to each other. Lay vapour barrier under Strongboard for carpet. Prime
Strongboard for carpet immediately after completion. Observe all installation instruc-
tions and manufacturers instructions.
Additional insulation
20 mm EPS 035 DEO 200 kPa; existing buildings: 40 mm XPS 035 500 kPa
Construction
According to EnEV, EN 1264, DIN 1055, 18195 and 18202
Construction number 86
Technical Data Floors/ceilings facing unheated rooms or the ground
6
7