  • Hello! I'm your AI assistant. I've reviewed the user manual for the Tynetec Sensor Controller models ZXT473 and ZXT474. This manual covers the setup, use, and features of the device, including bed/chair occupancy monitoring, alarm settings, and integration with other alarm systems. I am ready to answer your questions about the Sensor Controller and its functionalities.
  • What is the Sensor Controller primarily used for?
    What other sensors can the Sensor Controller be used with besides bed and chair sensors?
    Can bedside or table lamps be automatically controlled with the Sensor Controller?
    Does the Sensor Controller have automatic British Summer Time adjustment?
DocNo.FM0600issueH1Page1
169MHzTelecareDevices
SensorController
_______________________________________________________________________________________________________________

   
CompatiblewithReachathomealarms,Adventxtwardencall,
AltecResponseandTouchsafeProNursecallsystems
Canbeusedforbedorchairoccupancymonitoring
Fullyconfigurablewithtextdisplaymenus
RealtimeclockwithautoBSTadjustment
Suppliedwithmainsadapter&rechargeablebattery
CompatiblewithGadgetmainsswitchers
Dimensions:190mmx100mmx32mm(HxWxD)
Weight:285grams(incbattery)
SensorControllerwithstandardbedsensor:ProductCodeZXT473
SensorControllerwithstandardchairsensor:ProductCodeZXT474
WhatistheSensorControllerusedfor?
Thesensorcontrollerisnormallyusedforbedorchairoccupancymonitoring;ifapersongetsintobed/sitsintheirchair,thengetsup
againanddoesnotreturnwithinapresetperiodanalarmcallwillbetransmitted.Alternativelythesensorcontrollercanbeusedwitha
floorpressurematoradoorcontacttoraiseaninstantalarm.Bedsideortablelampscanbeturnedon/offautomaticallyusingthe
optionalGadgetmainsswitchers.
HowdoestheSensorControllerwork?
Thesensorcontrollerisnormallysuppliedwithastandardbedorchairsensorasacompletepackage.Thecontrollerandothersensor
optionsarealsoavailableseparatelyifcustompackagesarerequired.
ThesensorcontrollermustbeinstalledwithaReachathomealarm,anAdventxtwardencallsystem,anAltecResponselocalcarer
alarmunitoraTouchsafeProNursecallsystem.
ThesensorcontrollerhasarealtimeclockwithautomaticBritishSummerTimeadjustments(i.e.the+/‐1hourclockchangesaremade
automaticallyonthecorrectdayeveryMarchandOctober).
Withastandardbedorchairsensoranalarmcanberaisedeitherinstantlyapersonleavestheirbed/chairoraftera1to99minute
programmableabsenceperiodifthepersondoesnotreturntotheirbed/chair.Ifthepersondoesnotreturnandanalarmisraisedbut
theyareOK,thenanoptional1to99minuteprogrammableresetperiodcanbeset.Ifthepersonisnotdetectedbackintheirbed/chair
attheendofthisperiodthenanalarmwillberaisedagain.
Monitoringstartswhenapersonhasbeenintheirbed/chairfor30seconds(defaultloggedinbedtime).Continuousmonitoringis
possibleifthecontrollerissettobeonallthetime.Alternativelyupto3activeperiodscanbeprogrammedtorepeateveryday.There
isalsotheoptiontoraiseanalarmifapersonisnotintheirbed/chairaftera0to999minuteprogrammabledelayfromthestartofthe
monitoringperiod.
Monitoringwillendattheendofeachmonitoringperiodunlessthestillinbed/chairoptionisset.Thisisa0to999minute
programmableperiodifthepersonisstillintheirbed/chairattheendofthisperiodanalarmwillberaised.
IfthepersonisgoingtobeawayfromhomeforafewdaystheSensorControllerhasanawaymodefeaturewhichtemporarilysuspends
monitoringtopreventfalsealarms.Whenthepersonreturnshometheunitmustbeswitchedbackintohomemodeandnormal
monitoringwillresume.
ThesensorcontrollerhasaCarerCallbuttontoactivateanalarmcallatanytime.AnoptionalPearPushleadisavailabletoactivatea
carercallandswitchlampson/off(Gadgetmainsswitcherrequired).
WithaMagicStickorSensAlertbed/chairsensoranalarmcanberaisedeitherinstantlyapersonleavestheirbed/chairoraftera
programmable0to999secondcountdowndelay.Thealarmcanbecancelledduringthecountdownbypressingthekey.
Withapressurematordoorcontactanalarmcanberaisedeitherinstantlyapersonstepsonthematoropensthemonitoreddooror
afteraprogrammable0to999secondcountdowndelay.Thealarmcanbecancelledduringthecountdownbypressingthekey.
Bedsideortablelampscanbeturnedon/offautomaticallywithGadgetmainsswitchers(availableseparately).
AnRJ45doubleadapterisusedtoconnect2sensorspercontroller‐Note:bothsensorsmustbethesametype.
Tynetec andAidcallare businessunitsofLegrandElectricLtd
Unit10CowleyRoad,BlythRiversideBusinessPark,Blyth
Northumberland,NE245TF.Tel:01670352371Fax:01670362807
Email:sales@tynetec.co.ukWeb:www.tynetec.co.uk
DocNo.FM0600issueH1Page2
CONTENTS
SectionTopicPage
1HowtoconnecttheSensorController2
2HowtoinstallaBedSensor3
3HowtoinstallaChairSensor 3
4HowtoinstallaPressureMat3
5HowtoinstallDoorContacts3
6HowtoinstallaMagicStickBedSensor 4
7HowtoinstallaMagicStickChairSensor4
8HowtoinstallaSensAlertOverMattressBedSensor4
9HowtoinstallaSensAlertOverCushionChair Sensor 4
10HowtoswitchtheSensorControllerON/OFF5
11LowBatteryWarning5
12NavigatingtheDisplayMenu’s5
13QuickSetupMode5
14AdvancedSetupMode7
15RegistrationMode8
16RegisteringaSensorControllerontoaReachAthomeAlarm9
17RegisteringaSensorControllerontoanAdventxtWardenCall 10
18RegisteringaSensorControllerontoanAltecResponse CarerAlarm 11
19RegisteringaSensorControllerontoaTouchsafeProNursecall12
20Home/AwayMode13
21CarerCallFacility13
22OptionalPearPush13
1.HOWTOCONNECTTHESENSORCONTROLLER
Thesensorcontrollerincludesapowerleadandarechargeablebattery,dependingonthepackageitmayalsobesuppliedwitheithera
bedsensororachairsensor.Alternativebed/chairsensors,pressuremat,doorcontactsanddoubleadapterareavailableseparately.


1. Thesensorcontrollershouldbewithin3metresofamainssupply,ifanextensioncableisnecessarycareshouldbetakento
ensurethatnoonecantripoverthepowerlead.
2. SlidethebatterycompartmentopenontherearofthesensorcontrollerandconnecttheRECHARGEABLEBATTERY.
3. PlugthePOWERLEADintothePOWERSOCKETandconnecttothemainssupply.
4. PlugtheBED/CHAIRSENSOR/MAGICSTICKorPRESSUREMATorDOORCONTACTintotheSENSORSOCKET.
5. Note:anRJ45DOUBLEADAPTERcanbeusedtoconnect2oftheSAMETYPEsensorsintotheSENSORSOCKET.
6. TheI/OSOCKETisonlyusedforanoptionalPearPushleadortoconnecttheauxiliaryrelayoutput
STANDARDBED
SENSOR
STANDARDCHAIR
SENSOR
DOOR
CONTACT
PRESSURE
MAT
I
/
OSOCKET
SENSORSOCKET
POWERSOCKET
POWER
LEAD
SENSOR
CONTROLLER
RECHARGEABLE
BATTERY
RJ45 DOUBLE
ADAPTER
BED/CHAIRMAGIC
STICK
OVERMATTRESS
BEDSENSOR
OVERCUSHION
CHAIRSENSOR
DocNo.FM0600issueH1Page3
Door Frame
Door
2.HOWTOINSTALLABEDSENSOR
TheBedSensormustbeplacedbetweenthebedbaseandthemattress.
Checkthebaseisinreasonableconditionwithaflatfirmsurfacetolaythesensoron.
Thesensorshouldbeplacedacrossthewidthofthebedatapointwherethe
hipsofthepersonwillbewhenlyingdown.Ensuretheconnectingcable
exitssafelywithoutcausingatriphazard.
Plugtheleadintothesensorcontroller.
SpareBedSensorwith2mLead:ProductCodeZCS844
Dimensions:650mmx130mmx10mm(LxWxD)
RJ45DoubleAdapter(usedtoconnect2bedsensors):ProductCodeP10285
3.HOWTOINSTALLACHAIRSENSOR
TheChairSensormustbeplacedbetweentheseatbaseandthecushion.
Checkthebaseisinreasonableconditionwithaflatfirmsurfacetolaythesensoron.
Thesensorshouldbeplacedacrossthewidthofthechairatapointwherethe
personwillbesitting.Ensuretheconnectingcableexitssafelywithout
causingatriphazard.
Plugtheleadintothesensorcontroller.
SpareChairSensorwith2mLead:ProductCodeZCS859
Dimensions:325mmx130mmx10mm(LxWxD)
RJ45DoubleAdapter(usedtoconnect2chairsensors):ProductCodeP10285
4.HOWTOINSTALLAPRESSUREMAT
ThePressureMatmustbeplacedunderthecarpetorarug
alongsidethebedsoitwillbestoodonwhen
thepersongetsoutofbed.
Thematshouldbeplacedsotheconnectingcableexits
safelywithoutcausingatriphazard.
Plugtheleadintothesensorcontroller.
PressureMatwith2mleadisorderedseparately:ProductCodeZCS857
Dimensions:520mmx400mmx6mm(LxWxD)
RJ45DoubleAdapter(usedtoconnect2pressuremats):ProductCodeP10285
5.HOWTOINSTALLDOORCONTACTS
TheDoorContactsshouldbeinstalledbya
competentpersonontheframe
ofthedoorbeingmonitored.
Fixthecontact(partwithwireconnected)
tothedoorframe.Clipthecabletothe
doorframeandroutesafelywithout
causingatriphazard.
Fixthemagnettothedoor.Thereshould
benomorethan10mmbetweenthe   Magnet
2partswhenthedoorisclosed.  
Plugtheleadintothesensorcontroller.
DoorContactwith2mleadisorderedseparately:ProductCodeZCS854
RJ45DoubleAdapter(usedtoconnect2doorcontacts):ProductCodeP10285
Cable to Sensor Controller
DocNo.FM0600issueH1Page4
6.HOWTOINSTALLAMAGICSTICKBEDSENSOR
PlacetheMagicStickbetweenthebedbaseandthe
mattressensuringtheconnectingcableexitssafely
withoutcausingatriphazard.
  

   


MagicStickBedSensorwith3mleadisorderedseparately:ProductCodeZCS851
Dimensions:1000mmx15mmx7mm(LxWxD)
RJ45DoubleAdapter(usedtoconnect2BedSensors):ProductCodeP10285
7.HOWTOINSTALLAMAGICSTICKCHAIRSENSOR
PlacetheMagicStickbetweentheseatbaseandthecushionwithitrunningcentrallyacrossthewidthofthechair.
CheckthebaseisinreasonableconditionwithaflatfirmsurfacetolaytheMagicStickon.
Ensuretheconnectingcableexitssafelywithoutcausingatriphazard.
The“button”sideofthesensorstripshouldbelaiddownwardsandsecuredusingtheVelcrostraps.
Plugtheleadintothesensorcontroller.
MagicStickChairSensorwith3mleadorderedseparately:ProductCodeZCS852
Dimensions:400mmx15mmx7mm(LxWxD)
RJ45DoubleAdapter(usedtoconnect2chairsensors):ProductCodeP10285
8.HOWTOINSTALLASENSALERTOVERMATTRESSBEDSENSOR
TheSensAlertBedSensormustbeplacedontopofthemattressbelowthesheet.
SeetheplacementoptionsprintedontheBedSensor.
Ensuretheconnectingcableexitssafelywithoutcausingatriphazard.
Plugtheleadintothesensorcontroller.
SensAlertBedSensorwith2mLeadisorderedseparately:ProductCodeZCS861
Dimensions:750mmx250mmx5mm(LxWxD)
RJ45DoubleAdapter(usedtoconnect2bedsensors):ProductCodeP10285
9.HOWTOINSTALLA
S
ENSALERTOVERCUSHIONCHAIR
S
ENSOR
TheSensAlertChairSensormustbeplacedontopoftheseatcushion.
SeetheplacementoptionsprintedontheChairSensor.
Ensuretheconnectingcableexitssafelywithoutcausingatriphazard.
Plugtheleadintothesensorcontroller.
SensAlertChairSensorwith2mLeadisorderedseparately:ProductCodeZCS862
Dimensions:375mmx250mmx5mm(LxWxD)
RJ45DoubleAdapter(usedtoconnect2chairsensors):ProductCodeP10285
NeverplacetheMagic
S
t
i
ckontopofthemattress.
1.Ifthebedhasahardflatbasethe“button”sideofthe
sensorstripshouldbelaiddownwards.
2.SecuretheMagicSticktothebedbaseusingthe
Velcrostrapsprovided.
3.Ifthebedhasanopenframebasethe“flat”side
ofthesensorstripshouldbelaiddownwards.
4.SecuretheMagicSticktothestrutsofthebase
usingtheVelcrostrapsprovided.
5.Plugtheleadintothesensorcontroller.
DocNo.FM0600issueH1Page5
10.HOWTO
S
WITCHON/OF
F
Oncethepowerleadispluggedinandswitchedonthedisplay
willflashPressENTERforSetup”.
PresstheENTERkeyandtheMainMenuwillbedisplayed.
ThebatterysymbolshouldbeflashinginthetopoftheMain
Menudisplaytoindicatethebatteryisbeingcharged.
After20secondsthedisplaywillgoblank,theunitisstillon
butthedisplaygoesofftosavepower.
Thesensorcontrollershouldbeleftpluggedinandswitched
onatalltimes‐thiswillensureitsbatteryisalwaysfully
chargedandalarmswillalwaysbetransmitted.
TOSWITCHOFF
SwitchthemainssupplyOFFandunplugpowerlead.
PresstheENTERkeytodisplaytheMainMenu.
PressthekeytoselectPowerOff thenpressENTER.
ThedisplaywillshowTheControllerisPoweringDown
beforeswitchingoff.
11.LOWBATTERYWARNING
Ifthemainspowerfailsthesensorcontrollerwillcontinueto
operatefromitsbattery.
Thelengthoftimethesensorcontrollerwilloperateforon
batteryalonewilldependonusage.
Whenthebatteryisrunninglowtheunitwillbeepand
displaySendingaLowBatteryAlarm”.
Whenthebatteryisexhaustedtheunitwilldisplay
LowBatteryControllerisPoweringDownbefore
turningitselfoff.
Whenthemainspowerisrestoreditwillneedatleast8hours
tofullyrechargethebattery.
Thelowbatterybeepcanbedisabledinprogramming.
Detailedinformationonbatterymanagementforall
Tynetec/Aidcallproductsisavailable‐requestacopyof
DocNo.FM0630.
12.NAVIGATINGTHEDISPLAYMENU
S
PresstheENTERkeyonceandthedisplaywillilluminate.
Usethekeystoscrollup/downthroughtheoptions.
The arrowsinthetoprightofthedisplayindicatemore
menuoptionsareavailableusingtheup/downkeys.
Main Menu V1.07A
Quick Setup
Advanced Setup
Power Off
ScrolldownpastPowerOffandthedisplaywillshow;
Main Menu V1.07A
Exit
Themenuoptionhighlightedinarrowscanbeselected
withtheENTERkey.
Thiswilleithertakeyoutoanothersubmenuorgiveyouthe
optiontochangesettings.
Usethekeystoincrease/decreasethesettinghighlighted
bythecursor.
Usethekeystomovethecursorback/forwardsbetween
fields.
ToreturntotheMainMenupressthe&keystogether.
ToexittheMainMenuselectExitandpresstheENTER
key,thedisplaywillblank.
13.QUICKSETUPMODE
SelectQuickSetupfromtheMainMenuandpressthe
ENTERkey,thedisplaywillshow;
Would you like to set
the date and time ?
yes = enter, next =
PressENTERandthedisplaywillchangetoEnterDate
(useDD/MM/YYformat).
UsethekeystosettheDate(DD)thenpress
UsethekeystosettheMonth(MM)thenpress
UsethekeystosettheYear(YY)thenpressENTERand
thedisplaywillchangetoEnterDay
UsethekeystosettheDaythenpressENTERandthe
displaywillchangetoEnterTime(24hourformat).
UsethekeystosettheHour(HH)thenpress
UsethekeystosettheMinutes(MM)thenpressENTER
andthedisplaywillchangetoAutoBST
UsethekeystosetAutoBSTOnorOffthenpressENTER
(OnmeanstheBritishSummerTime+/‐1houradjustments
willbemadeautomaticallyeveryMarch/October).
Thedisplaywillgobacktothesetdateandtimemenu,
pressthekeytomovetothenextoption;
Would you like to set
the sensor type ?
yes = enter, next =
PresstheENTERkeyandthedisplaywillchangeto
SetSensorType;BedStandard”.Usethekeystoselect
from;BedMagicStickorChairStandardorChairMagicStick
orAuxthenpressENTER.Note:use“Aux”forpressuremator
doorcontact.Use“BedMagicStick”forSensAlertbedsensor.
Use“ChairMagicStick”forSensAlertchairsensor.
Thedisplaywillgobacktothesetsensortypemenu,press
thekeytomovetothenextoption;
Would you like to set
the on/off times ?
yes = enter, next =
PresstheENTERkeyandthedisplaywillchangeto
OnAllTheTime?No
Chooseifyouwantthebed/chairmonitoredallthetimeor
duringpresetperiodseachday.
UsethekeystochooseYesorNothenpressENTER.
IfyouchooseNothedisplaywillchangeto
EnterStartTime100:00(24HRformat).
UsethekeystosettheHourthenpress
UsethekeystosettheMinutesthenpressENTERand
thedisplaywillchangetoEnterStopTime100:00
DocNo.FM0600issueH1Page6
13.QUICKSETUPMODE‐CONTINUED
RepeatasabovetosettheStopTimethenpresstheENTER
keythedisplaywillchangetoAnotherTimeSlot?No
UsethekeytoselectYestoentermoretimeslotsorpress
theENTERkey.
Thedisplaywillgobacktotheseton/offtimesmenu,press
thekeytomovetothenextoption;
Would you like an
instant alarm ?
yes = enter, next =
PresstheENTERkeyandthedisplaywillchangeto
InstantAlarm?No
UsethekeystochooseYesorNothenpressENTER.
IfyouchooseYesanalarmwillbesentimmediatelythe
personleavestheirbed/chair.
Thedisplaywillgobacktotheinstantalarmmenu,press
thekeytomovetothenextoption;
Would you like a delay
before an alarm ?
yes = enter, next =
PresstheENTERkeyandthedisplaywillchangeto
EnterTimeDelay;00Mins
Usethekeystosetthedelaybeforeanalarmfrom
1to99MinutesthenpresstheENTERkey.
Thedisplaywillgobacktothedelaybeforealarmmenu,
pressthekeytomovetothenextoption;
Would you like a
NOT IN BED alarm ?
yes = enter, next =
PresstheENTERkeyandthedisplaywillchangeto
NotinBedAlarm;No
UsethekeystochooseYesorNothenpressENTER.
IfyouchooseNothemonitoringwillstartwhenthepersonis
detectedinbed.
IfyouchooseYesthedisplaywillchangeto
NotinBedAlarm;HowLong?000Mins
Usethekeystosetthenotinbedalarmfrom0to999
minutesthenpresstheENTERkey(analarmwillbesentifthe
personisnotinbedafterthisperiod).
Thedisplaywillgobacktothenotinbedalarmmenu,press
thekeytomovetothenextoption;
Would you like a
STILL IN BED alarm ?
yes = enter, next =
PresstheENTERkeyandthedisplaywillchangeto
StillinBedAlarm;No
UsethekeystochooseYesorNothenpressENTER.
IfyouchooseNothemonitoringwillendattheendofthe
monitoringperiod.
IfyouchooseYes,thedisplaywillchangeto
StillinBedAlarm;HowLong?000Mins
Usethekeystosetthestillinbedalarmfrom0to999
minutesthenpresstheENTERkey(analarmwillbesentifthe
personisstillinbedafterthisperiod).
Thedisplaywillgobacktothestillinbedalarmmenu,press
thekeytomovetothenextoption;
Would you like to
calibrate sensor ?
yes = enter, next =
Note:thisoptionisnotrelevantforMagicSticks,SensAlert
orAuxsensors.
Ifusingastandardbed/chairsensorpresstheENTERkeyand
thedisplaywillchangetoPutSensorUnderMattress/Chair
andPressENTERWhenReady
Placethesensorunderthemattressorchaircushionthen
presstheENTERkey.
Thedisplaywillshow30SecsLeft…PLEASEWAIT…and
countdowntozerowhilethesensorisbeingcalibrated.
Thedisplaywillgobacktothecalibratesensormenu,press
thekeytomovetothenextoption;
Would you like to
go into test mode ?
yes = enter, next =
PresstheENTERkeyandthedisplaywillchangeto;
Test Mode
…….. No Client ……..
exit
Gettheclienttolieonthebed/sitinthechairandthedisplay
shouldshow…..ClientDetected…..
Remainonthebed/chairfor10secondsandthedisplaywill
showUnitissendingstatusINcode
Afterashortdelay(whentheINstatusisbeingtransmitted)
thedisplayshouldshow…..ClientLoggedIN…..
Gettheclientoffthebed/outthechairandthedisplaywill
showUnitissendingstatusOUTcode
Afterashortdelay(whentheOUTstatusisbeingtransmitted)
thedisplayshouldshow…..ClientOUT…..
After10secondstheunitwillstarttobeepandthedisplaywill
show…..Alarm…..
Afterafurther10secondsandthedisplaywillshowUnitis
sendingALARMcode
EndofTestMode.
Note:iftheclientisnotdetectedasinthebed/chairthenyou
mayneedtoadjustthesensitivitygototheAdvanced
Setup
CalibrateandTest
ChangeSensitivityoption.
Seepage9.
Thedisplaywillgobacktothetestmodemenu,pressthe
keytomovetothenextoption;
DocNo.FM0600issueH1Page7
13.QUICKSETUPMODE‐CONTINUED
Would you like a low
battery alarm beep ?
yes = enter, next =
PresstheENTERkeyandthedisplaywillchangeto
LowBatteryBeep?No
UsethekeystochooseYesorNothenpressENTER.
IfyouchooseYestheunitwillbeepasawarningwhenits
batterypowerisrunninglow.
ThedisplaywillgobacktotheLowBatteryBeepmenu,
pressthekeytomovetothenextoption;
Would you like a
beep when armed ?
yes = enter, next =
PresstheENTERkeyandthedisplaywillchangeto
BeepWhenArmed?No
UsethekeystochooseYesorNothenpressENTER.
ThedisplaywillgobacktotheBeepWhenArmedmenu,
pressthekeytomovetothenextoption;
Would you like to
register the device ?
yes = enter, next =
Theoptionisusedtoregisterthesensorcontrollerontothe
athomealarm,wardencall,carercallorNursecallsystem.
BeforepressingENTERtherelevantproductmustbeputinto
“LearnMode”seepage8onwards.
PresstheENTERkeyandthedisplaywillchangeto
Registrationdataisbeingsent
AfterashortdelaythedisplaywillgobacktotheRegister
Devicemenu,pressthekeytomovetothenextoption;
To exit press the
enter button
yes = enter, next =
PressENTERtogobacktotheMainMenuorpressthekey
togobacktothebeginningoftheQuickStartMenu.
14.ADVANCEDSETUPMOD
E
FromtheMainMenudisplayselectAdvancedSetupand
presstheENTERkeyforthefollowingoptions;
Advanced Setup
Calibrate and Test
Alarm Setup
Clock Setup
Advanced Setup
Lights Setup
Factory Setup
Exit
SelectCalibrateandTestthenpressENTER;
Calibrate and Test
Calibrate Sensor
View In/Out States
Change Sensitivity
Calibrate and Test
Test Mode
Exit
CalibrateSensorplacethebed/chairsensorinpositionand
pressENTERtolearntheunoccupiedweight.
ViewIn/OutStatesofeachtransducerinthebed/chairsensor.
ChangeSensitivityofeachtransducer(0=leastsensitiveto5
=mostsensitive).
TestModechecktheclientisdetectedin/outofthe
bed/chair(seepage5fordetails).
FromtheAdvancedSetupmenuselectAlarmSetup
thenpresstheENTERkey;
Alarm Setup
Set Timeout
Set Sensor Type
Always On
Alarm Setup
Active Period 1
Active Period 2
Active Period 3
Alarm Setup
Not/Still in Bed
Low Battery Alert
Logged in Bed Time
Alarm Setup
Beep When Armed
Exit
SetTimeout(0to99mins)forAbsenceandReset;
Absence=timeapersonisallowedoutoftheirbed/chair.
Reset=timeapersonisallowedtogetbackintotheir
bed/chairafteran“outofbed/chair”alarmhasbeenactivated.
SetSensorTypeas;StandardBed,MagicStickBed,Standard
Chair,MagicStickChairorAux.
IfAuxischosenthenyougettheoptiontochangetheAlarm
Code(default34=doorexit)andtheCountdown(delay
beforealarm)0to999secs.
AlwaysOnEnable/Disable,ifdisabledsettheActivePeriods;
ActivePeriods13‐setStart/Stoptimesforupto3active
periodsperday(Note:theserepeateveryday).
Not/StillinBed‐Enable/Disableeachoftheseoptionsandset
thedelaybeforealarm(0to999mins).
LowBatteryAlert‐Enable/Disabletheaudiblebeep.
LoggedinBedTime=timeapersonmustbeintheirbed/chair
beforemonitoringstarts(0to999secs).
BeepWhenArmed‐Enable/Disableanaudiblebeepwhen
monitoringstarts.
DocNo.FM0600issueH1Page8
14.ADVANCED
S
ETUPMODE‐CONTINUED
FromtheAdvancedSetupmenuselectClockSetupthen
presstheENTERkey;
Clock Setup
Set Date 01:01:00
Set Day Mon
Set Time 00:00
Clock Setup
Auto BST
Exit
SetDateinDD/MM/YYformat.
SetDayMontoSun.
SetTimeinHH/MMformatusing24hourclock.
AutoBSTusethekeystoEnableorDisable
automatic+/‐1hourBritishSummerTimeadjustments.
FromtheAdvancedSetupmenuselectLightsSetupthen
presstheENTERkey;
Lights Setup
Radiplugs Setup
RadiPlugs Address
Gadgets Setup
Lights Setup
Gadgets Address
X10 Setup
X10 House Code
Lights Setup
X10 Lights Off
X10 Light 1 Setup
X10 Light 1 Setup
Lights Setup
Exit
Mainslampscanbeswitchedon/offautomaticallywhenusers
getin/outoftheirbed/chairusing“Gadget”mainsswitchers.
FormoreinformationonsetupseetheGadgetInstallation
Guide:DocNo.FM0671

Gadgets
Note:theRadiplugandX10mainsswitchersarelegacy
productswhicharenowdiscontinued.
FromtheAdvancedSetupmenuselectFactorySetup
thenpresstheENTERkey;
Factory Setup
Load Defaults
Program ID
Register Device
Factory Setup
I/O Setup
Exit
LoadDefaultsandApplytorestorefactorysettingsasbelow;
Date01:01:00
Time00:00withAutoBSTon
Sensortype:uncalibratedbedsensor
Onallthetime:No
Activestart/stoptimeperiods:all00:00(disabled)
Instantalarm:Yes
DelaybeforeAlarm:No
NotinBedAlarm:No
StillinBedAlarm:No
LowBatteryBeep:Yes
Radiplugs,X10&Gadgets:alldisabled.
ProgramIDtoenterthelast6digitsfromtheproductlabel.
RegisterDevicetolearntheunitontoanathomealarm,
wardencall,carercallorNursecallsystem.
I/OSetuptochooseaPearPushoraRelayOutput,
UsethekeystoEnableorDisableaPearPushswitch
(seesection22).
Ifthepearpushisdisabledyouwillgettheoptiontosetthe
RelayOnTimefrom0to99seconds.Therelayactivateswith
anyalarmN/OcontactsonI/Osocketpins1&3.
Note:itisonlypossibletosetaPearPushoraRelayOutput
(notboth).
15.REGISTRATIONMODE
Thesensorcontrollermustberegisteredontoanathome
alarm,wardencall,carercallorNursecallsystem.The
simplestwaytotransmitregistrationdataistopressthe
CARERCALLbutton.

 )))))))

Seethefollowingpagesforhowtoputeachoftheabove
productsinto“LearnMode”.
Therangeofallradiodevicescanbeaffectedby
theworkingenvironment.Alwaystakecare
duringinstallationandperformseveraltestcalls.
“Bed
Occupancy”
DocNo.FM0600issueH1Page9
16.REGISTERINGA
S
ENSORCONTROLLERONTOAREACHA
T
HOMEALAR
M
1.PuttheReachunitintoradiodevicelearnmode…

    


2.Activatethesensorcontroller…

  


3.Exitradiodevicelearnmode…
 
    


4.CheckwiththeControlCentrethatitisconvenienttoperformatestcall,presstheCARERCALLbuttonandconfirmtheyreceivethe
correctalarmcalltypei.e.bedoccupancy,chairoccupancyordoorexit.
DeletingaSensorControllerfromaReachathomealarmunit
Enter1670usingthekeypadontherearoftheReachunitthefrontlightwillFLASHFASTGREENandtheunitwillannounce
ProgramMode‐Ready”.
Enter#041andtheReachwillannounceDeleteRadioDevicefollowedbyaBeep”.
Enterthe8digitsensorcontrollerIDtobedeleted;aftertheBeeppress#toexit.
PressthekeytoexitProgramMode;theunitwillsoundaDoubleBeepandthefrontlightwillreturntoSTEADYGREEN.
The8digitIDismadeupofthe2digitsensortypecodee.g.bedsensor=33,chairsensor=38ordoorexit=34followedbythe6digit
unitIDwhichcanbefoundonalabelonthebackofthesensorcontroller.
TheinstructionsgivenaboveforthestandardReachproductalsoappliestotheReachPlus,ReachPlusGSM
andReachUltramodels.Refertotheinstructionbookletsprovidedwiththeseproductsformoreinformation
onprogrammingandtestingradiodevices.

Trigger
Radio
Device
PressandHOLDtheGREENbuttonontheReachunit.
WhenthefrontlightFLASHESFASTGREENreleasethe
buttonandtheReachwillannounceTriggerRadioDevice”.
Younowhave1minutetoactivatethesensorcontroller.
PresstheGREENbuttonontheReachunit.
ThefrontlightwillreturntoSTEADYGREENandtheReach
isbackinnormaloperatingmode.
PresstheCARERCALLbuttonandtheReachwillannouncethetype
ofsensorthathasbeensetup…
aunitwithabedsensorwillannounceBedOccupancy
or
aunitwithachairsensorwillannounceChairOccupancy
or
aunitwithapressurematordoorcontactwillannounceDoorExit
DocNo.FM0600issueH1Page10
17.REGISTERINGA
S
ENSORCONTROLLERONTOANADVENTxtWARDENCALL
1.PuttheAdventxtsystemintoradiodevicelearnmode…
 
    
 

2.Activatethesensorcontroller…

 


3.ExittheAdventxtsystemradiodevicelearnmode…
 
     


4.PresstheCARERCALLbuttonandcheckthecorrectalarmcalltypeisreportedonthewardencallsystem.
DeletingaSensorControllerfromanAdventxtwardencallsystem
PresstheLINEkeyandwaitfortheReadyprompt.
Enter5001followedbythekey.
Entertheflatnumberthebedmonitorisbeingdeletedfromfollowedbythekey.
PresstheCARERCALLbuttononthesensorcontrollertobedeleted.
WaitforthePendantDisabledEnterFlatprompt.
Pressthe#keyandwaitfortheReadyprompt,thenpresstheLINEkeytocleartheconnection.
RefertotheAdventxtoperatorsmanual(DocNo.FM0420)providedwiththewardencallsystemformore
informationonprogrammingandtestingradiodevices.
UsingtheManager’sDECTtelephone;
PresstheLINEkeyandwaitfortheReadyprompt.
Enter5000followedbythekey.
Entertheflatnumberthesensorcontrollerisbeinginstalledin
followedbythekey.
Younowhave1minutetoactivatethesensorcontroller.
Ready”
UsingtheManager’sDECTtelephone;
Pressthe#keyandwaitfortheReadyprompt.
PresstheLINEkeytocleartheconnectionandthewardencallsystemis
nowbackinnormaloperatingmode.
PresstheCARERCALL button.
WaitfortheEnterLocationCodepromptthenpress0(nolocation)
followedbythekey.
WaitforthePendantEnabledEnterFlatprompt.
Ready”
DocNo.FM0600issueH1Page11
1
8
.REGISTERINGA
S
ENSORCONTROLLERONTOANALTECRESPONSECARERALAR
M
1.PuttheAltecResponseunitintoradiodevicelearnmode…

    
 

2.Activatethesensorcontroller…

  




3.ExittheAltecResponseradiodevicelearnmode…

     


4.PresstheCARERCALLbuttonandcheckthecorrectalarmcalltypeisdisplayedontheAltecResponseunit.
DeletingaSensorControllerfromanAltecResponselocalcareralarmunit
PressENTERtoactivatethewakeupdisplaythenENTERagaintodisplaythemainmenu
PressENTERtoselectRadioDevices
PressthekeytoselectDeleteDevicethenpressENTER
ThedisplaywillpromptyoutoTriggertheSensor
PresstheCARERCALLbuttononthesensorcontrollertobedeleted‐thedisplaywillshowthedevicetypeandits8digitID
IfthisisthedeviceyouactivatedpressthekeytoselectDeletethenpressENTER
Ifit’sNOTthedeviceyouactivatedpresstheENTERkeytoselectRejectthentryagain
ToexitthemodeselectExitthenpresstheENTERkey.
RefertotheAltecResponseinstallationguide(DocNo.FM0548)providedwiththeportablealarmunitfor
moreinformationonprogrammingandtestingradiodevices.
PresstheCARERCALLbutton.
ThedisplaywillshowtheSensorTypeandthesensorcontroller8digitIDnumber.
ChecktheIDiscorrect,pressthekeytoselectAcceptthenpressENTER.
Note:ifanotherdevicehasbeenpickeduppressENTERtoRejectandtryagain.
ThedisplaywillshowFlat,usethe&keystochoosethedwellingtype.
PressthekeytoselectNo:000000thenpresstheENTERkey.
Usethe&keystoselecteachdigitoftheflatnumberandthe&keys
tomovebetweendigitsthenpresstheENTERkey.
PresskeyseveraltimestoselectExitthenpresstheENTERkey.
ThedisplaywillpromptyoutoTriggertheSensoragain.
PressENTERtoactivatethewakeupdisplaythenENTERagaintodisplay
themainmenu.
PressENTERtoselectRadioDevices
PressENTERtoselectLearnDevice
ThedisplaywillpromptyoutoTriggertheSensor”.
Younowhave20secondstoactivatethesensorcontroller.
FromtheLearnDevicemenuselectExitthenpressENTER.
FromtheRadioDevicesmenuselectExitthenpressENTER.
Thedisplaywillreturntothewakeupscreenandgoblankafter10seconds.
TheAltecResponseisnowbackinnormaloperatingmode.
tynetec
tynetec
DocNo.FM0600issueH1Page12
19.REGISTERINGA
S
ENSORCONTROLLERONTOATOUCHSAFEPRONURSECALL
1.PuttheTouchsafeProMasterPanelintoTelecareregistrationmode;touchthescreenandLogonasanEngineeroraManager
(passwordrequired),thenfromthemainmenupagetouchtheTelecarebuttontoopenthescreenshownbelow…


2.EnterthesensorcontrollerID…


3.PresstheClosebuttontoexitTelecaremodeandtheNursecallpanelisnowbackinnormaloperatingmode.
4.PresstheCARERCALLandcheckthecallisdisplayedontheNursecallpanellikethis…
Thescreenbannerisyellowforabedoccupancycall(Touchthebannertodisplaynotes).
PresstheAcceptbuttononthebannertosilencethealarm‐thiswillalso
notifyallotherpanelsthecallisbeingdealtwith.
Thescreenbannerchangestopurplewhenacallisaccepted.
YoumustvisittheappropriateNursecallCallPointtocancelthecall.
DeletingaSensorControllerfromaTouchsafeProNursecallsystem
SelectthesensorcontrollerIDtobedeletedfromtheDeleteTelecareDevicepulldownlistbox(prefixedwitha“T33/34/38”).
DetailsoftheSensorControllerselectedwillbedisplayedintheRoom,HouseCodeandIDboxesbelow.
IfthedetailsshownarecorrectpresstheDeletebutton.
PresstheClosebuttontoexit.
RefertotheTouchsafeProDisplayPaneluserguide(DocNo.FM5505)providedwiththeNursecallsystemfor
moreinformation.

The8digitIDisprintedonalabelontherearofthesensorcontroller.
Note:thisIDwillalwaysstartwith33xxxxxx(bedsensor).Youmustchangethefirst
2digitsto38xxxxxxforachairsensoror34xxxxxxforapressuremat/doorcontact.

TouchtheAddTelecareDeviceboxthenusetheonscreenkeypadtoentertheID.
Hint:enterazoneintheFilterboxtonarrowthesearchfortheroom(seebelow).
SelecttheusersCallPointIDfromtheRoompulldownlistboxthenpressSave.
Note:thisistheroomunitthatwillbewillbeusedtocancelthecall.
Usekeypadtoenter
8digitIDhere
Selecttherelevant
CallPointIDhere
Savewhendone
Closetoexitmode
Onscreenkeypad
CALLING
CANCEL
HC345ID001
ZXT450W65210
Ser:10154095
ID:33040508
EE1315V1.07A
JD
PresstheLIGHTGREY
buttontocancelthecall
DocNo.FM0600issueH1Page13
20.HOME/AWAYMOD
E
IfthepersonisgoingtobeawayfromhomeformorethanonedayyoumustselectAWAYMODEtopreventfalse“notinbed”alarms.
WhenthesensorcontrollerisinitsnormaloperatingmodethekeyisusedtotogglebetweenHOME/AWAYmode.
Pressthiskeyonceandthedisplaywillshow;
The unit is now in
AWAY mode
Afterabout10secondsthedisplaywillblank‐duringthismodenoalarmcallswillbesent.
REMEMBER:whenthepersonreturnshomethesensorcontrollermustbeputbackintotheHOMEmode.
PresstheHOME/AWAYkeyonceandthedisplaywillshow;
The unit is now in
HOME mode
Afterabout10secondsthedisplaywillblank‐normalmonitoringisnowresumed.
21.CARERCALLFACILITY
TheCarerCallfacilitycanbeusedtoraiseaninstantalarmcallviathewardencallsystem,athomealarmorNursecallsystem.
WhenthesensorcontrollerisinitsnormaloperatingmodethekeyisusedtosendaCARERCALL.
Pressthiskeyonceandthedisplaywillshow;
Unit is sending a
CARER CALL alarm
…… PLEASE WAIT……
Afterabout10secondsthedisplaywillblank.
Youwillhearreassurancetonesfromtheathomealarmorwardencallintercomwhenthecallisbeingmade.
22.OPTIONALPEARPUSH
ThePearPushswitchoptionmustbeenabledintheI/OSetupseesection14(page8).
ThePearPushhas2functions;PEARPUSH
1.Presson/offtotogglealampon/off(Gadgetmainsswitchersrequired).
2.Pressandholdformorethan3secondstoactivateanalarmcall.
PearPushwith2mLead:ProductCodeZNC680

IfGadgetmainsswitchersarefittedthenthelampwillalsocomeonwithanalarmcall.
TynetecandAidcalloperateapolicyofcontinuousimprovementandreservetherighttochangeproductspecificationswithoutnotice.
IfanyvariationtothedetailscontainedinthisdocumentaresuspectedpleasecontactTynetec’scustomersupportdepton01670352371.
/