_________________________________________________________________________
________________________________________________________________
Doc No. FM0826 V1.08 Page 1
• Fixed trigger device
• Used to support the care of dementia patients
• Compatible with Reach IP, Advent XT2, Carer Response
and Touchsafe Pro V4.01 onward
• Complies with BS EN 50134-2:2017
• Integrated left and right-side reed switches
• Surface magnetic door contact
• On/off power switch
• Red alarm transmit LED indicator
• Green alarm received LED indicator
• 2 No. AAA Alkaline batteries
• Low battery warning
• Operating Temperature: +5oC to +40oC
• Telecare Transceiver: 869.2125MHz Class 1.5
• Digital Heartbeat
• Weight: 55 grams
• Dimensions: 85mm x 34mm x 24mm (HxWxD)
• Product Code: ZXT830
The door alarm can be used to raise a door open alarm
when a door is opened. The Reach IP can be setup with an
active time span (i.e. start/end time) when the door alarm
will be active. Door open alarms will only be reported if
the door is opened within this pre-set time period.
Note: with this type of door alarm, it is not possible to set
an active time span on the Advent XT2 or Carer Response.
With these products a door open alarm will be reported
whenever the door is opened.
Positioning
The door alarm can be mounted on the door frame and
the magnet on the door, or vice-versa. The magnet can be
placed on either side of the door alarm. The distance
between the door alarm and the magnet must not exceed
10mm when the door is closed. If the door is made from
metal the magnet may need to be closer.
Alarm Condition
When a monitored door is opened, it transmits an alarm
and the LED will illuminate red for 4 seconds. When the
alarm is acknowledged by the Reach IP or XT2 system the
LED will illuminate green for 2 seconds – it does not go
green when used with a Carer Response. A new alarm will
not be triggered until the door has been closed and
opened again.
In/out Passage Delay Option
The in/out passage delay option allows Carers to enter and
leave without triggering an alarm call.
If the in/out passage delay is enabled, the door alarm waits
5 seconds before sending an alarm when the door is
opened. During this time the LED will flash red. If the
power switch is turned off when the LED is flashing red an
alarm call will not be triggered.
When leaving, an alarm is not triggered if the door is
opened during the first 5 seconds after the power switch is
turned on.
Low Battery Condition
A low battery condition will be reported automatically to
the Alarm Receiving Centre (ARC) or the local Manager.
The batteries should be replaced as soon as possible within
30 days.
Out of Range Notification (Reach IP)
The Reach IP can monitor all radio peripheral devices to
determine whether they have been damaged or removed
from an installation. Should the Reach IP be unable to
detect a device’s heartbeat it will automatically generate a
“radio out of range” notification. Firstly, investigate if
there’s a genuine reason for the alert, if not, arrange for
the peripheral device to be replaced immediately.
The “Radio out of range timer” can be set from 30 hours to
99999 hours in Pulse CMP. “Radio supervision” can be
disabled by unchecking the tick box associated with each
peripheral device in Pulse CMP.
Maintenance
Test the door alarm once every month.
Clean with a damp cloth, do not use solvents or cleaners
on the door alarm.
Disposal
Waste electrical products should not be disposed
of with normal household waste. The door alarm
is ideally suited for disposal within the waste
electronic and electrical equipment (WEEE)
recycling scheme. Please recycle where facilities exist.
Check with your local authority or contact your supplier for
recycling/disposal advice.