  • Hello! I am an AI chatbot trained to assist you with the Savant ENC-TRANS-00 Reference guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
The Savant SmartLighting Transorb Board (ENC-TRANS), Quick Reference Guide provides
installation information.
Box Contents
(1) Transorb Board (ENC-TRANS-00)
(2) Screws 6-32 x 0.375 in (039-5150-600)
(1) Quick Reference Guide (this document)
Required Accessories
Two Module Enclosure (ENC-2000-xx)
Four Module Enclosure (ENC-4000-xx)
Specifications
Environmental
Environmental
Temperature
32° to 95° F (0° to 35° C) - Ambient Operating
Dimensions and Weight
Dimensions and Weight
Height
2.20 in/5.59 cm
Width
2.20 in/5.59 cm
Weight
1.0 lb/ 0.45 kg (shipping weight)
Compliance
Compliance
RoHS
Compliant
!"#$%&&'$()'**+ !"#$%&&'()$*+,-./'0,12,"*"$#
62 LiteTouch Installation and Troubleshooting Manual
Plug a data cable into the five-pin connector on the transorb board, and
plug the other end into the DATA IN port on the first module.
2. Connect another data cable to the DATA OUT port on the first module
and to the DATA IN port on the second module.
3. Continue to connect a cable to the DATA OUT port of one module and
the DATA IN port of the next module until all control modules in the
enclosure are connected.
!"#$
!"#"$%&'&()$*+,-$(+#$.+((,.#$#+$/+%,'$-0//1&,-2$3+3,(#"'4$.+(#".#$*"#"$&(/0#$
3+*01,-2$+'$3"&(#"&(,*$.+(#".#$*"#"$&(/0#$3+*01,-5$611$3+*01,-$#7"#$30-#$8,$
&(.10*,*$&($#7,$*"#"$%&'&()$7"9,$!6:6$;<$"(*$!6:6$=>:$/+'#-5$
When finished, all control modules in each enclosure should be connected
in a string to the first module (top module), which is connected to the tran-
sorb board via the 5-pin connector.
,$-."/'0"1&2#3-)#
42 / ) $ ( ) -
In large installations (more than eight enclosures), or when you have mul-
tiple enclosure locations, you can string enclosures together to reduce the
number of data homeruns to the CCU. While this helps to simplify the
wiring, you should be aware that an early circuit breaker failure in the
Module Bus Connector
RJ-45 Ports
!"#$%&&'()$*+,-./'0,12,"*"$# !"#$%&&'$()'**+
LiteTouch Installation and Troubleshooting Manual 63
string leaves all modules beyond the failure without communication to the
CCU.
!"#$
!"#$%"&#'($)&*#$+(*,&-$)&*#.$&-$/"#$(,/,$0,1'#$23%/$1#$04--#0/#($/4$#,0"$24(5
3'#6$/4$#,0"$/*,-%4*1$14,*(6$,-($/4$/"#$7789$:/$%#*;#%$,%$,$<*43-($*#=#*#-0#$
=4*$04223-&0,/&4-%9
LiteTouch number 08-2105-01 wire is recommended for data wiring. It
contains two twisted-pair, 22-gauge wires and an insulated bare shield
wire. The cable is shielded with mylar. The table below shows LiteTouch
wire colors. The cable color used for data wiring is green.
6800-202
U
L
®
LISTED
71TO
IND. CONT. EQ.
®
L
R
50210
3550
SO
.
700
WEST
SL
C
.,
U
T
AH
84119
(801)
268-8 668
F
A
X
(801)
268 -9200
TE
CH
H
OT
L
I
N
E
1-800-527- 5527
W
A
RNING
A
S
H
O
R
TE
D
LO
AD
W
I
LL
DA
M
A
GE
M
O
DU
LE
..
T
H
I
S
I
S
N
OT
C
OVE
R
E
D
B
Y
W
ARRAN
TY
.
TO
A
VO
I
D
POSS
I
B
LE
DA
M
A
GE
TO
M
O
DU
LE
AC
POWE
R
M
U
ST
B
E
R
E
M
OVE
D
B
EFO
R
E
C
O
NN
E
C
T
I
N
G
O
R
D
I
S
C
O
NN
E
C
T
I
N
G
LO
AD
S
.
®
R
ated
2
A
mp
s
15
V
o
l
t
s
M
a
x
.
N
e
u
t
r
a
l
120
V
A
C
60
HZ
N
e
u
t
r
a
l
120
V
A
C
60
HZ
W
I
R
E
RAN
GE
10
-
16
A
WG
.
/
TO
R
Q
U
E
10
-
12
I
N
.
L
B
S
.
/
60
c
M
I
N
.
C
OPPE
R
W
I
R
E
O
N
LY
POW
E
R
DC P
o
s
.
DC C
om
.
F
U
S
E
A
G
C
5
A
mp
.
N
OT
U
SE
D
POW
E
R
DC P
o
s
.
DC C
om
.
F
U
S
E
A
G
C
5
A
mp
.
N
OT
U
SE
D
P
ower
OUTPUT 5
OUTPUT 6
OUTPUT 7
OUTPUT 8
INPUT 120VAC 6 0Hz
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
NEUTRAL
OUTPUT 1
OUTPUT 2
OUTPUT 3
OUTPUT 4
6800-270
®
®
LISTED
71TO
IND. CONT. EQ.
1
s
t
DI
G
IT
2
n
d
DI
G
IT
A
DD
R
E
SS
S
WITCH
E
S
A
DD
R
E
SS
R
A
T
E
D
20
A
MP
S
TOT
A
L
,
12 0
V
O
L
T
S
TUN
G
S
T
E
N
NOT TO
E
XC
EE
D
16
A
MP
S
ON
A
NY
S
IN
G
L
E
OUTPUT
C
A
UTION
R
I
S
K
O
F
E
L
E
CT
R
IC
A
L
S
HOC
K
. H
E
A
T
S
IN
K
I
S
L
I
V
E
. DI
S
CONN
E
CT
F
R
OM POW
E
R
B
E
F
O
R
E
S
E
R
V
ICIN
G
.
®
1
2
3
4
5
R
E
C
E
I
V
E
+
R
E
C
E
I
V
E
T
R
A
N
S
MIT +
T
R
A
N
S
MIT –
G
ND/
S
HI
E
L
D
D
A
T
A
IN
1
2
3
4
5
R
E
C
E
I
V
E
+
R
E
C
E
I
V
E
T
R
A
N
S
MIT +
T
R
A
N
S
MIT –
G
ND/
S
HI
E
L
D
D
A
T
A
OUT
NO.
1
NO.
2
NO.
3
NO.
4
NO.
5
NO.
6
NO.
7
NO.
8
NO.
1
NO.
2
NO.
3
NO.
4
NO.
5
NO.
6
NO.
7
NO.
8
A
CTI
V
E
L
O
A
D
L
E
D
S
3550
S
O.
700
W
E
S
T •
S
L
C., UT
A
H
84119
(
801
)
268
-
8668
F
A
X
(
801
)
268
-
9200
• T
E
CH HOT
L
IN
E
1
-
800
-
527
-
5527
W
A
R
NIN
G
A
S
HO
R
T
E
D
L
O
A
D WI
LL
B
L
OW
F
U
S
E
A
ND C
A
N D
A
M
A
G
E
M ODU
L
E
.
THI
S
I
S
NOT CO
V
E
R
E
D
B
Y W
A
RR
A
NTY.
WI
R
E
R
A
N
G
E
10
-
16
A
W
G
.
TO
R
QU
E
10
-
12
IN.
L
B
S
.
60
c
M IN. COPP
E
R
WI
R
E
ON
L
Y
U
S
E
F
A
S
T
A
CTIN
G
20
A
MP
F
U
S
E
S
.
1
2
3
4
5
6
7
8
M
A
NU
A
L
O
FF
ON
S
E
RI
A
L
NO.
____________________________________
POWER
1
2
3
4
5
6
7
8
R
E
MOT
E
M
A
NU
A
L
ON
COMMON
C
D
imm er
OUTPUT 5
OUTPUT 6
OUTPUT 7
OUTPUT 8
INPUT 120VAC 6 0Hz
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
NEUTRAL
OUTPUT 1
OUTPUT 2
OUTPUT 3
OUTPUT 4
6800-270
®
®
LISTED
71TO
IND. CONT. EQ.
1
s
t
DI
G
IT
2
n
d
DI
G
IT
A
DD
R
E
SS
S
WITCH
E
S
A
DD
R
E
SS
R
A
T
E
D
20
A
MP
S
TOT
A
L
,
12 0
V
O
L
T
S
TUN
G
S
T
E
N
NOT TO
E
XC
EE
D
16
A
MP
S
ON
A
NY
S
IN
G
L
E
OUTPUT
C
A
UTION
R
I
S
K
O
F
E
L
E
CT
R
IC
A
L
S
HOC
K
. H
E
A
T
S
IN
K
I
S
L
I
V
E
. DI
S
CONN
E
CT
F
R
OM POW
E
R
B
E
F
O
R
E
S
E
R
V
ICIN
G
.
®
1
2
3
4
5
R
E
C
E
I
V
E
+
R
E
C
E
I
V
E
T
R
A
N
S
MIT +
T
R
A
N
S
MIT –
G
ND/
S
HI
E
L
D
D
A
T
A
IN
1
2
3
4
5
R
E
C
E
I
V
E
+
R
E
C
E
I
V
E
T
R
A
N
S
MIT +
T
R
A
N
S
MIT –
G
ND/
S
HI
E
L
D
D
A
T
A
OUT
NO.
1
NO.
2
NO.
3
NO.
4
NO.
5
NO.
6
NO.
7
NO.
8
NO.
1
NO.
2
NO.
3
NO.
4
NO.
5
NO.
6
NO.
7
NO.
8
A
CTI
V
E
L
O
A
D
L
E
D
S
3550
S
O.
700
W
E
S
T •
S
L
C., UT
A
H
84119
(
801
)
268
-
8668
F
A
X
(
801
)
268
-
9200
• T
E
CH HOT
L
IN
E
1
-
800
-
527
-
5527
W
A
R
NIN
G
A
S
HO
R
T
E
D
L
O
A
D WI
LL
B
L
OW
F
U
S
E
A
ND C
A
N D
A
M
A
G
E
M ODU
L
E
.
THI
S
I
S
NOT CO
V
E
R
E
D
B
Y W
A
RR
A
NTY.
WI
R
E
R
A
N
G
E
10
-
16
A
W
G
.
TO
R
QU
E
10
-
12
IN.
L
B
S
.
60
c
M IN. COPP
E
R
WI
R
E
ON
L
Y
U
S
E
F
A
S
T
A
CTIN
G
20
A
MP
F
U
S
E
S
.
1
2
3
4
5
6
7
8
M
A
NU
A
L
O
FF
ON
S
E
RI
A
L
NO.
____________________________________
POWER
1
2
3
4
5
6
7
8
R
E
MOT
E
M
A
NU
A
L
ON
COMMON
C
D
imm er
LISTED
71TO
IND. CONT. EQ.
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
1
s
t
DI
G
IT
2
s
t
DI
G
IT
POW
E
R
A
DD
R
E
SS
S
WITCH
E
S
NEUTRAL 1
LINE 1
LOAD 1
LINE 2
LOAD 2
LINE 3
LOAD 3
LINE 4
LOAD 4
LINE 5
LOAD 5
LINE 6
LOAD 6
LINE 7
LOAD 7
LINE 8
LOAD 8
1
2
3
4
5
R
E
C
E
I
V
E
+
R
E
C
E
I
V
E
T
R
A
N
S
MIT +
T
R
A
N
S
MIT –
G
ND/
S
HI
E
L
D
D
A
T
A
IN
1
2
3
4
5
6
7
8
9
1
2
3
4
5
R
E
C
E
I
V
E
+
R
E
C
E
I
V
E
T
R
A
N
S
MIT +
T
R
A
N
S
MIT –
G
ND/
S
HI
E
L
D
D
A
T
A
OUT
NO.
1
NO.
2
NO.
3
NO.
4
NO.
5
NO.
6
NO.
7
NO.
8
A
CTI
V
E
L
O
A
D
L
E
D'
S
INT
E
RR
L
OC
K
S
WITCH
E
S
R
E
MOT
E
M
A
NU
A
L
ON
COMMON
M
A
NU
A
L
ON
3550
S
O.
700
W
E
S
T •
S
L
C., UT
A
H
84119
(
801
)
268
-
8668
F
A
X
(
801
)
268
-
9200
• T
E
CH HOT
L
IN
E
1
-
800
-
527
-
5527
W
A
RNING
A
S
HO
R
T
E
D
L
O
A
D WI
LL
D
A
M
A
G
E
M ODU
L
E
.
THI
S
I
S
NOT CO
V
E
R
E
D
B
Y W
A
RR
A
NTY.
TO T
E
S
T
F
O
R
S
HO
R
T, CONN
E
CT
L
IN
E
TO
L
O
A
D
S
A
ND
A
PP
L
Y POW
E
R
B
E
F
O
R
E
CONN
E
CTIN
G
L
O
A
D
S
TO
SS
C M ODU
L
E
.
TO
A
V
OID PO
SS
I
B
L
E
D
A
M
A
G
E
TO MODU
L
E
A
C POW
E
R
M U
S
T
B
E
R
E
MO
V
E
D
B
E
F
O
R
E
CONN
E
CTIN
G
O
R
DI
S
CONN
E
CTIN
G
L
O
A
D
S
.
WI
R
E
R
A
N
G
E
12
-
22
A
W
G
.
TO
R
QU
E
10
-
12
IN.
L
B
S
.
60
c
M IN. COPP
E
R
WI
R
E
ON
L
Y
®
U
L
®
U
L
®
SERIAL NO.
RELAY RATINGS
VOLTAGE
INC.
FLUOR.
LV.
LOAD TYPE RATING
8.3A @ 120/250V AC
12A @ 120/250V AC
12A @ 120/250V AC
AC
60 Hz
1/2 HP @ 120VAC
1 HP @ 240VAC
MOTOR
S
E
R
I
A
L
NO.
_________________
C
12345678
R
ela
y
6800-202
U
L
®
LISTED
71TO
IND. CONT. EQ.
®
L
R
50210
3550
SO
.
700
WEST
SL
C
.,
U
T
AH
84119
(801)
268-8 668
F
A
X
(801)
268-9200
TE
CH
H
OT
L
I
N
E
1-800 -527-5527
W
A
RNING
A
S
H
O
R
TE
D
LO
AD
W
I
LL
DA
M
A
GE
M
O
DU
LE
..
T
H
I
S
I
S
N
OT
C
OVE
R
E
D
B
Y
W
ARRAN
TY
.
TO
A
VO
I
D
POSS
I
B
LE
DA
M
A
GE
TO
M
O
DU
LE
AC
POWE
R
M
U
ST
B
E
R
E
M
OVE
D
B
EFO
R
E
C
O
NN
E
C
T
I
N
G
O
R
D
I
S
C
O
NN
E
C
T
I
N
G
LO
AD
S
.
®
R
ated
2
A
mp
s
15
V
o
l
t
s
M
a
x
.
N
e
u
t
r
a
l
120
V
A
C
60
HZ
N
e
u
t
r
a
l
120
V
A
C
60
HZ
W
I
R
E
RAN
GE
10
-
16
A
WG
.
/
TO
R
Q
U
E
10
-
12
I
N
.
L
B
S
.
/
60
c
M
I
N
.
C
OPPE
R
W
I
R
E
O
N
LY
POW
E
R
DC P
o
s
.
DC C
om
.
F
U
S
E
A
G
C
5
A
mp
.
N
OT
U
SE
D
POW
E
R
DC P
o
s
.
DC C
om
.
F
U
S
E
A
G
C
5
A
mp
.
N
OT
U
SE
D
P
ower
OUTPUT 5
OUTPUT 6
OUTPUT 7
OUTPUT 8
INPUT 120VAC 6 0Hz
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
NEUTRAL
OUTPUT 1
OUTPUT 2
OUTPUT 3
OUTPUT 4
6800-270
®
®
LISTED
71TO
IND. CONT. EQ.
1
s
t
DI
G
IT
2
n
d
DI
G
IT
A
DD
R
E
SS
S
WITCH
E
S
A
DD
R
E
SS
R
A
T
E
D
20
A
MP
S
TOT
A
L
,
12 0
V
O
L
T
S
TUN
G
S
T
E
N
NOT TO
E
XC
EE
D
16
A
MP
S
ON
A
NY
S
IN
G
L
E
OUTPUT
C
A
UTION
R
I
S
K
O
F
E
L
E
CT
R
IC
A
L
S
HOC
K
. H
E
A
T
S
IN
K
I
S
L
I
V
E
. DI
S
CONN
E
CT
F
R
OM POW
E
R
B
E
F
O
R
E
S
E
R
V
ICIN
G
.
®
1
2
3
4
5
R
E
C
E
I
V
E
+
R
E
C
E
I
V
E
T
R
A
N
S
MIT +
T
R
A
N
S
MIT –
G
ND/
S
HI
E
L
D
D
A
T
A
IN
1
2
3
4
5
R
E
C
E
I
V
E
+
R
E
C
E
I
V
E
T
R
A
N
S
MIT +
T
R
A
N
S
MIT
G
ND/
S
HI
E
L
D
D
A
T
A
OUT
NO.
1
NO.
2
NO.
3
NO.
4
NO.
5
NO.
6
NO.
7
NO.
8
NO.
1
NO.
2
NO.
3
NO.
4
NO.
5
NO.
6
NO.
7
NO.
8
A
CTI
V
E
L
O
A
D
L
E
D
S
3550
S
O.
700
W
E
S
T •
S
L
C., UT
A
H
84119
(
801
)
268
-
8668
F
A
X
(
801
)
268
-
9200
• T
E
CH HOT
L
IN
E
1
-
800
-
527
-
5527
W
A
R
NIN
G
A
S
HO
R
T
E
D
L
O
A
D WI
LL
B
L
OW
F
U
S
E
A
ND C
A
N D
A
M
A
G
E
M ODU
L
E
.
THI
S
I
S
NOT CO
V
E
R
E
D
B
Y W
A
RR
A
NTY.
WI
R
E
R
A
N
G
E
10
-
16
A
W
G
.
TO
R
QU
E
10
-
12
IN.
L
B
S
.
60
c
M IN. COPP
E
R
WI
R
E
ON
L
Y
U
S
E
F
A
S
T
A
CTIN
G
20
A
MP
F
U
S
E
S
.
1
2
3
4
5
6
7
8
M
A
NU
A
L
O
FF
ON
S
E
RI
A
L
NO.
____________________________________
POWER
1
2
3
4
5
6
7
8
R
E
MOT
E
M
A
NU
A
L
ON
COMMON
C
D
imm er
OUTPUT 5
OUTPUT 6
OUTPUT 7
OUTPUT 8
INPUT 120VAC 6 0Hz
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
NEUTRAL
OUTPUT 1
OUTPUT 2
OUTPUT 3
OUTPUT 4
6800-270
®
®
LISTED
71TO
IND. CONT. EQ.
1
s
t
DI
G
IT
2
n
d
DI
G
IT
A
DD
R
E
SS
S
WITCH
E
S
A
DD
R
E
SS
R
A
T
E
D
20
A
MP
S
TOT
A
L
,
12 0
V
O
L
T
S
TUN
G
S
T
E
N
NOT TO
E
XC
EE
D
16
A
MP
S
ON
A
NY
S
IN
G
L
E
OUTPUT
C
A
UTION
R
I
S
K
O
F
E
L
E
CT
R
IC
A
L
S
HOC
K
. H
E
A
T
S
IN
K
I
S
L
I
V
E
. DI
S
CONN
E
CT
F
R
OM POW
E
R
B
E
F
O
R
E
S
E
R
V
ICIN
G
.
®
1
2
3
4
5
R
E
C
E
I
V
E
+
R
E
C
E
I
V
E
T
R
A
N
S
MIT +
T
R
A
N
S
MIT –
G
ND/
S
HI
E
L
D
D
A
T
A
IN
1
2
3
4
5
R
E
C
E
I
V
E
+
R
E
C
E
I
V
E
T
R
A
N
S
MIT +
T
R
A
N
S
MIT
G
ND/
S
HI
E
L
D
D
A
T
A
OUT
NO.
1
NO.
2
NO.
3
NO.
4
NO.
5
NO.
6
NO.
7
NO.
8
NO.
1
NO.
2
NO.
3
NO.
4
NO.
5
NO.
6
NO.
7
NO.
8
A
CTI
V
E
L
O
A
D
L
E
D
S
3550
S
O.
700
W
E
S
T •
S
L
C., UT
A
H
84119
(
801
)
268
-
8668
F
A
X
(
801
)
268
-
9200
• T
E
CH HOT
L
IN
E
1
-
800
-
527
-
5527
W
A
R
NIN
G
A
S
HO
R
T
E
D
L
O
A
D WI
LL
B
L
OW
F
U
S
E
A
ND C
A
N D
A
M
A
G
E
M ODU
L
E
.
THI
S
I
S
NOT CO
V
E
R
E
D
B
Y W
A
RR
A
NTY.
WI
R
E
R
A
N
G
E
10
-
16
A
W
G
.
TO
R
QU
E
10
-
12
IN.
L
B
S
.
60
c
M IN. COPP
E
R
WI
R
E
ON
L
Y
U
S
E
F
A
S
T
A
CTIN
G
20
A
MP
F
U
S
E
S
.
1
2
3
4
5
6
7
8
M
A
NU
A
L
O
FF
ON
S
E
RI
A
L
NO.
____________________________________
POWER
1
2
3
4
5
6
7
8
R
E
MOT
E
M
A
NU
A
L
ON
COMMON
C
D
imm er
LISTED
71TO
IND. CONT. EQ.
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
1
s
t
DI
G
IT
2
s
t
DI
G
IT
POW
E
R
A
DD
R
E
SS
S
WITCH
E
S
NEUTRAL 1
LINE 1
LOAD 1
LINE 2
LOAD 2
LINE 3
LOAD 3
LINE 4
LOAD 4
LINE 5
LOAD 5
LINE 6
LOAD 6
LINE 7
LOAD 7
LINE 8
LOAD 8
1
2
3
4
5
R
E
C
E
I
V
E
+
R
E
C
E
I
V
E
T
R
A
N
S
MIT +
T
R
A
N
S
MIT –
G
ND/
S
HI
E
L
D
D
A
T
A
IN
1
2
3
4
5
6
7
8
9
1
2
3
4
5
R
E
C
E
I
V
E
+
R
E
C
E
I
V
E
T
R
A
N
S
MIT +
T
R
A
N
S
MIT –
G
ND/
S
HI
E
L
D
D
A
T
A
OUT
NO.
1
NO.
2
NO.
3
NO.
4
NO.
5
NO.
6
NO.
7
NO.
8
A
CTI
V
E
L
O
A
D
L
E
D'
S
INT
E
RR
L
OC
K
S
WITCH
E
S
R
E
MOT
E
M
A
NU
A
L
ON
COMMON
M
A
NU
A
L
ON
3550
S
O.
700
W
E
S
T •
S
L
C., UT
A
H
84119
(
801
)
268
-
8668
F
A
X
(
801
)
268
-
9200
• T
E
CH HOT
L
IN
E
1
-
800
-
527
-
5527
W
A
RNING
A
S
HO
R
T
E
D
L
O
A
D WI
LL
D
A
M
A
G
E
M ODU
L
E
.
THI
S
I
S
NOT CO
V
E
R
E
D
B
Y W
A
RR
A
NTY.
TO T
E
S
T
F
O
R
S
HO
R
T, CONN
E
CT
L
IN
E
TO
L
O
A
D
S
A
ND
A
PP
L
Y POW
E
R
B
E
F
O
R
E
CONN
E
CTIN
G
L
O
A
D
S
TO
SS
C M ODU
L
E
.
TO
A
V
OID PO
SS
I
B
L
E
D
A
M
A
G
E
TO MODU
L
E
A
C POW
E
R
M U
S
T
B
E
R
E
MO
V
E
D
B
E
F
O
R
E
CONN
E
CTIN
G
O
R
DI
S
CONN
E
CTIN
G
L
O
A
D
S
.
WI
R
E
R
A
N
G
E
12
-
22
A
W
G
.
TO
R
QU
E
10
-
12
IN.
L
B
S
.
60
c
M IN. COPP
E
R
WI
R
E
ON
L
Y
®
U
L
®
U
L
®
SERIAL NO.
RELAY RATINGS
VOLTAGE
INC.
FLUOR.
LV.
LOAD TYPE RATING
8.3A @ 120/250V AC
12A @ 120/250V AC
12A @ 120/250V AC
AC
60 Hz
1/2 HP @ 120VAC
1 HP @ 240VAC
MOTOR
S
E
R
I
A
L
NO.
_________________
C
12345678
R
ela
y
OUTPUT 5
OUTPUT 6
OUTPUT 7
OUTPUT 8
INPUT 120VAC 6 0Hz
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
NEUTRAL
OUTPUT 1
OUTPUT 2
OUTPUT 3
OUTPUT 4
6800-270
®
®
LISTED
71TO
IND. CONT. EQ.
1
s
t
DI
G
IT
2
n
d
DI
G
IT
A
DD
R
E
SS
S
WITCH
E
S
A
DD
R
E
SS
R
A
T
E
D
20
A
MP
S
TOT
A
L
,
12 0
V
O
L
T
S
TUN
G
S
T
E
N
NOT TO
E
XC
EE
D
16
A
MP
S
ON
A
NY
S
IN
G
L
E
OUTPUT
C
A
UTION
R
I
S
K
O
F
E
L
E
CT
R
IC
A
L
S
HOC
K
. H
E
A
T
S
IN
K
I
S
L
I
V
E
. DI
S
CONN
E
CT
F
R
OM POW
E
R
B
E
F
O
R
E
S
E
R
V
ICIN
G
.
®
1
2
3
4
5
R
E
C
E
I
V
E
+
R
E
C
E
I
V
E
T
R
A
N
S
MIT +
T
R
A
N
S
MIT –
G
ND/
S
HI
E
L
D
D
A
T
A
IN
1
2
3
4
5
R
E
C
E
I
V
E
+
R
E
C
E
I
V
E
T
R
A
N
S
MIT +
T
R
A
N
S
MIT –
G
ND/
S
HI
E
L
D
D
A
T
A
OUT
NO.
1
NO.
2
NO.
3
NO.
4
NO.
5
NO.
6
NO.
7
NO.
8
NO.
1
NO.
2
NO.
3
NO.
4
NO.
5
NO.
6
NO.
7
NO.
8
A
CTI
V
E
L
O
A
D
L
E
D
S
3550
S
O.
700
W
E
S
T •
S
L
C., UT
A
H
84119
(
801
)
268
-
8668
F
A
X
(
801
)
268
-
9200
• T
E
CH HOT
L
IN
E
1
-
800
-
527
-
5527
W
A
R
NIN
G
A
S
HO
R
T
E
D
L
O
A
D WI
LL
B
L
OW
F
U
S
E
A
ND C
A
N D
A
M
A
G
E
M ODU
L
E
.
THI
S
I
S
NOT CO
V
E
R
E
D
B
Y W
A
RR
A
NTY.
WI
R
E
R
A
N
G
E
10
-
16
A
W
G
.
TO
R
QU
E
10
-
12
IN.
L
B
S
.
60
c
M IN. COPP
E
R
WI
R
E
ON
L
Y
U
S
E
F
A
S
T
A
CTIN
G
20
A
MP
F
U
S
E
S
.
1
2
3
4
5
6
7
8
M
A
NU
A
L
O
FF
ON
S
E
RI
A
L
NO.
____________________________________
POWER
1
2
3
4
5
6
7
8
R
E
MOT
E
M
A
NU
A
L
ON
COMMON
C
D
imm er
OUTPUT 5
OUTPUT 6
OUTPUT 7
OUTPUT 8
INPUT 120VAC 6 0Hz
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
NEUTRAL
OUTPUT 1
OUTPUT 2
OUTPUT 3
OUTPUT 4
6800-270
®
®
LISTED
71TO
IND. CONT. EQ.
1
s
t
DI
G
IT
2
n
d
DI
G
IT
A
DD
R
E
SS
S
WITCH
E
S
A
DD
R
E
SS
R
A
T
E
D
20
A
MP
S
TOT
A
L
,
12 0
V
O
L
T
S
TUN
G
S
T
E
N
NOT TO
E
XC
EE
D
16
A
MP
S
ON
A
NY
S
IN
G
L
E
OUTPUT
C
A
UTION
R
I
S
K
O
F
E
L
E
CT
R
IC
A
L
S
HOC
K
. H
E
A
T
S
IN
K
I
S
L
I
V
E
. DI
S
CONN
E
CT
F
R
OM POW
E
R
B
E
F
O
R
E
S
E
R
V
ICIN
G
.
®
1
2
3
4
5
R
E
C
E
I
V
E
+
R
E
C
E
I
V
E
T
R
A
N
S
MIT +
T
R
A
N
S
MIT –
G
ND/
S
HI
E
L
D
D
A
T
A
IN
1
2
3
4
5
R
E
C
E
I
V
E
+
R
E
C
E
I
V
E
T
R
A
N
S
MIT +
T
R
A
N
S
MIT –
G
ND/
S
HI
E
L
D
D
A
T
A
OUT
NO.
1
NO.
2
NO.
3
NO.
4
NO.
5
NO.
6
NO.
7
NO.
8
NO.
1
NO.
2
NO.
3
NO.
4
NO.
5
NO.
6
NO.
7
NO.
8
A
CTI
V
E
L
O
A
D
L
E
D
S
3550
S
O.
700
W
E
S
T •
S
L
C., UT
A
H
84119
(
801
)
268
-
8668
F
A
X
(
801
)
268
-
9200
• T
E
CH HOT
L
IN
E
1
-
800
-
527
-
5527
W
A
R
NIN
G
A
S
HO
R
T
E
D
L
O
A
D WI
LL
B
L
OW
F
U
S
E
A
ND C
A
N D
A
M
A
G
E
M ODU
L
E
.
THI
S
I
S
NOT CO
V
E
R
E
D
B
Y W
A
RR
A
NTY.
WI
R
E
R
A
N
G
E
10
-
16
A
W
G
.
TO
R
QU
E
10
-
12
IN.
L
B
S
.
60
c
M IN. COPP
E
R
WI
R
E
ON
L
Y
U
S
E
F
A
S
T
A
CTIN
G
20
A
MP
F
U
S
E
S
.
1
2
3
4
5
6
7
8
M
A
NU
A
L
O
FF
ON
S
E
RI
A
L
NO.
____________________________________
POWER
1
2
3
4
5
6
7
8
R
E
MOT
E
M
A
NU
A
L
ON
COMMON
C
D
imm er
OUTPUT 5
OUTPUT 6
OUTPUT 7
OUTPUT 8
INPUT 120VAC 6 0Hz
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
NEUTRAL
OUTPUT 1
OUTPUT 2
OUTPUT 3
OUTPUT 4
6800-270
®
®
LISTED
71TO
IND. CONT. EQ.
1
s
t
DI
G
IT
2
n
d
DI
G
IT
A
DD
R
E
SS
S
WITCH
E
S
A
DD
R
E
SS
R
A
T
E
D
20
A
MP
S
TOT
A
L
,
12 0
V
O
L
T
S
TUN
G
S
T
E
N
NOT TO
E
XC
EE
D
16
A
MP
S
ON
A
NY
S
IN
G
L
E
OUTPUT
C
A
UTION
R
I
S
K
O
F
E
L
E
CT
R
IC
A
L
S
HOC
K
. H
E
A
T
S
IN
K
I
S
L
I
V
E
. DI
S
CONN
E
CT
F
R
OM POW
E
R
B
E
F
O
R
E
S
E
R
V
ICIN
G
.
®
1
2
3
4
5
R
E
C
E
I
V
E
+
R
E
C
E
I
V
E
T
R
A
N
S
MIT +
T
R
A
N
S
MIT –
G
ND/
S
HI
E
L
D
D
A
T
A
IN
1
2
3
4
5
R
E
C
E
I
V
E
+
R
E
C
E
I
V
E
T
R
A
N
S
MIT +
T
R
A
N
S
MIT –
G
ND/
S
HI
E
L
D
D
A
T
A
OUT
NO.
1
NO.
2
NO.
3
NO.
4
NO.
5
NO.
6
NO.
7
NO.
8
NO.
1
NO.
2
NO.
3
NO.
4
NO.
5
NO.
6
NO.
7
NO.
8
A
CTI
V
E
L
O
A
D
L
E
D
S
3550
S
O.
700
W
E
S
T •
S
L
C., UT
A
H
84119
(
801
)
268
-
8668
F
A
X
(
801
)
268
-
9200
• T
E
CH HOT
L
IN
E
1
-
800
-
527
-
5527
W
A
R
NIN
G
A
S
HO
R
T
E
D
L
O
A
D WI
LL
B
L
OW
F
U
S
E
A
ND C
A
N D
A
M
A
G
E
M ODU
L
E
.
THI
S
I
S
NOT CO
V
E
R
E
D
B
Y W
A
RR
A
NTY.
WI
R
E
R
A
N
G
E
10
-
16
A
W
G
.
TO
R
QU
E
10
-
12
IN.
L
B
S
.
60
c
M IN. COPP
E
R
WI
R
E
ON
L
Y
U
S
E
F
A
S
T
A
CTIN
G
20
A
MP
F
U
S
E
S
.
1
2
3
4
5
6
7
8
M
A
NU
A
L
O
FF
ON
S
E
RI
A
L
NO.
____________________________________
POWER
1
2
3
4
5
6
7
8
R
E
MOT
E
M
A
NU
A
L
ON
COMMON
C
D
imm er
OUTPUT 5
OUTPUT 6
OUTPUT 7
OUTPUT 8
INPUT 120VAC 6 0Hz
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
NEUTRAL
OUTPUT 1
OUTPUT 2
OUTPUT 3
OUTPUT 4
6800-270
®
®
LISTED
71TO
IND. CONT. EQ.
1
s
t
DI
G
IT
2
n
d
DI
G
IT
A
DD
R
E
SS
S
WITCH
E
S
A
DD
R
E
SS
R
A
T
E
D
20
A
MP
S
TOT
A
L
,
12 0
V
O
L
T
S
TUN
G
S
T
E
N
NOT TO
E
XC
EE
D
16
A
MP
S
ON
A
NY
S
IN
G
L
E
OUTPUT
C
A
UTION
R
I
S
K
O
F
E
L
E
CT
R
IC
A
L
S
HOC
K
. H
E
A
T
S
IN
K
I
S
L
I
V
E
. DI
S
CONN
E
CT
F
R
OM POW
E
R
B
E
F
O
R
E
S
E
R
V
ICIN
G
.
®
1
2
3
4
5
R
E
C
E
I
V
E
+
R
E
C
E
I
V
E
T
R
A
N
S
MIT +
T
R
A
N
S
MIT –
G
ND/
S
HI
E
L
D
D
A
T
A
IN
1
2
3
4
5
R
E
C
E
I
V
E
+
R
E
C
E
I
V
E
T
R
A
N
S
MIT +
T
R
A
N
S
MIT –
G
ND/
S
HI
E
L
D
D
A
T
A
OUT
NO.
1
NO.
2
NO.
3
NO.
4
NO.
5
NO.
6
NO.
7
NO.
8
NO.
1
NO.
2
NO.
3
NO.
4
NO.
5
NO.
6
NO.
7
NO.
8
A
CTI
V
E
L
O
A
D
L
E
D
S
3550
S
O.
700
W
E
S
T •
S
L
C., UT
A
H
84119
(
801
)
268
-
8668
F
A
X
(
801
)
268
-
9200
• T
E
CH HOT
L
IN
E
1
-
800
-
527
-
5527
W
A
R
NIN
G
A
S
HO
R
T
E
D
L
O
A
D WI
LL
B
L
OW
F
U
S
E
A
ND C
A
N D
A
M
A
G
E
M ODU
L
E
.
THI
S
I
S
NOT CO
V
E
R
E
D
B
Y W
A
RR
A
NTY.
WI
R
E
R
A
N
G
E
10
-
16
A
W
G
.
TO
R
QU
E
10
-
12
IN.
L
B
S
.
60
c
M IN. COPP
E
R
WI
R
E
ON
L
Y
U
S
E
F
A
S
T
A
CTIN
G
20
A
MP
F
U
S
E
S
.
1
2
3
4
5
6
7
8
M
A
NU
A
L
O
FF
ON
S
E
RI
A
L
NO.
____________________________________
POWER
1
2
3
4
5
6
7
8
R
E
MOT
E
M
A
NU
A
L
ON
COMMON
C
D
imm er
OUTPUT 5
OUTPUT 6
OUTPUT 7
OUTPUT 8
INPUT 120VAC 6 0Hz
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
NEUTRAL
OUTPUT 1
OUTPUT 2
OUTPUT 3
OUTPUT 4
6800-270
®
®
LISTED
71TO
IND. CONT. EQ.
1
s
t
DI
G
IT
2
n
d
DI
G
IT
A
DD
R
E
SS
S
WITCH
E
S
A
DD
R
E
SS
R
A
T
E
D
20
A
MP
S
TOT
A
L
,
12 0
V
O
L
T
S
TUN
G
S
T
E
N
NOT TO
E
XC
EE
D
16
A
MP
S
ON
A
NY
S
IN
G
L
E
OUTPUT
C
A
UTION
R
I
S
K
O
F
E
L
E
CT
R
IC
A
L
S
HOC
K
. H
E
A
T
S
IN
K
I
S
L
I
V
E
. DI
S
CONN
E
CT
F
R
OM POW
E
R
B
E
F
O
R
E
S
E
R
V
ICIN
G
.
®
1
2
3
4
5
R
E
C
E
I
V
E
+
R
E
C
E
I
V
E
T
R
A
N
S
MIT +
T
R
A
N
S
MIT –
G
ND/
S
HI
E
L
D
D
A
T
A
IN
1
2
3
4
5
R
E
C
E
I
V
E
+
R
E
C
E
I
V
E
T
R
A
N
S
MIT +
T
R
A
N
S
MIT
G
ND/
S
HI
E
L
D
D
A
T
A
OUT
NO.
1
NO.
2
NO.
3
NO.
4
NO.
5
NO.
6
NO.
7
NO.
8
NO.
1
NO.
2
NO.
3
NO.
4
NO.
5
NO.
6
NO.
7
NO.
8
A
CTI
V
E
L
O
A
D
L
E
D
S
3550
S
O.
700
W
E
S
T •
S
L
C., UT
A
H
84119
(
801
)
268
-
8668
F
A
X
(
801
)
268
-
9200
• T
E
CH HOT
L
IN
E
1
-
800
-
527
-
5527
W
A
R
NIN
G
A
S
HO
R
T
E
D
L
O
A
D WI
LL
B
L
OW
F
U
S
E
A
ND C
A
N D
A
M
A
G
E
M ODU
L
E
.
THI
S
I
S
NOT CO
V
E
R
E
D
B
Y W
A
RR
A
NTY.
WI
R
E
R
A
N
G
E
10
-
16
A
W
G
.
TO
R
QU
E
10
-
12
IN.
L
B
S
.
60
c
M IN. COPP
E
R
WI
R
E
ON
L
Y
U
S
E
F
A
S
T
A
CTIN
G
20
A
MP
F
U
S
E
S
.
1
2
3
4
5
6
7
8
M
A
NU
A
L
O
FF
ON
S
E
RI
A
L
NO.
____________________________________
POWER
1
2
3
4
5
6
7
8
R
E
MOT
E
M
A
NU
A
L
ON
COMMON
C
D
imm er
OUTPUT 5
OUTPUT 6
OUTPUT 7
OUTPUT 8
INPUT 120VAC 6 0Hz
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
NEUTRAL
OUTPUT 1
OUTPUT 2
OUTPUT 3
OUTPUT 4
6800-270
®
®
LISTED
71TO
IND. CONT. EQ.
1
s
t
DI
G
IT
2
n
d
DI
G
IT
A
DD
R
E
SS
S
WITCH
E
S
A
DD
R
E
SS
R
A
T
E
D
20
A
MP
S
TOT
A
L
,
12 0
V
O
L
T
S
TUN
G
S
T
E
N
NOT TO
E
XC
EE
D
16
A
MP
S
ON
A
NY
S
IN
G
L
E
OUTPUT
C
A
UTION
R
I
S
K
O
F
E
L
E
CT
R
IC
A
L
S
HOC
K
. H
E
A
T
S
IN
K
I
S
L
I
V
E
. DI
S
CONN
E
CT
F
R
OM POW
E
R
B
E
F
O
R
E
S
E
R
V
ICIN
G
.
®
1
2
3
4
5
R
E
C
E
I
V
E
+
R
E
C
E
I
V
E
T
R
A
N
S
MIT +
T
R
A
N
S
MIT –
G
ND/
S
HI
E
L
D
D
A
T
A
IN
1
2
3
4
5
R
E
C
E
I
V
E
+
R
E
C
E
I
V
E
T
R
A
N
S
MIT +
T
R
A
N
S
MIT
G
ND/
S
HI
E
L
D
D
A
T
A
OUT
NO.
1
NO.
2
NO.
3
NO.
4
NO.
5
NO.
6
NO.
7
NO.
8
NO.
1
NO.
2
NO.
3
NO.
4
NO.
5
NO.
6
NO.
7
NO.
8
A
CTI
V
E
L
O
A
D
L
E
D
S
3550
S
O.
700
W
E
S
T •
S
L
C., UT
A
H
84119
(
801
)
268
-
8668
F
A
X
(
801
)
268
-
9200
• T
E
CH HOT
L
IN
E
1
-
800
-
527
-
5527
W
A
R
NIN
G
A
S
HO
R
T
E
D
L
O
A
D WI
LL
B
L
OW
F
U
S
E
A
ND C
A
N D
A
M
A
G
E
M ODU
L
E
.
THI
S
I
S
NOT CO
V
E
R
E
D
B
Y W
A
RR
A
NTY.
WI
R
E
R
A
N
G
E
10
-
16
A
W
G
.
TO
R
QU
E
10
-
12
IN.
L
B
S
.
60
c
M IN. COPP
E
R
WI
R
E
ON
L
Y
U
S
E
F
A
S
T
A
CTIN
G
20
A
MP
F
U
S
E
S
.
1
2
3
4
5
6
7
8
M
A
NU
A
L
O
FF
ON
S
E
RI
A
L
NO.
____________________________________
POWER
1
2
3
4
5
6
7
8
R
E
MOT
E
M
A
NU
A
L
ON
COMMON
C
D
imm er
OUTPUT 5
OUTPUT 6
OUTPUT 7
OUTPUT 8
INPUT 120VAC 6 0Hz
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
NEUTRAL
OUTPUT 1
OUTPUT 2
OUTPUT 3
OUTPUT 4
6800-270
®
®
LISTED
71TO
IND. CONT. EQ.
1
s
t
DI
G
IT
2
n
d
DI
G
IT
A
DD
R
E
SS
S
WITCH
E
S
A
DD
R
E
SS
R
A
T
E
D
20
A
MP
S
TOT
A
L
,
12 0
V
O
L
T
S
TUN
G
S
T
E
N
NOT TO
E
XC
EE
D
16
A
MP
S
ON
A
NY
S
IN
G
L
E
OUTPUT
C
A
UTION
R
I
S
K
O
F
E
L
E
CT
R
IC
A
L
S
HOC
K
. H
E
A
T
S
IN
K
I
S
L
I
V
E
. DI
S
CONN
E
CT
F
R
OM POW
E
R
B
E
F
O
R
E
S
E
R
V
ICIN
G
.
®
1
2
3
4
5
R
E
C
E
I
V
E
+
R
E
C
E
I
V
E
T
R
A
N
S
MIT +
T
R
A
N
S
MIT –
G
ND/
S
HI
E
L
D
D
A
T
A
IN
1
2
3
4
5
R
E
C
E
I
V
E
+
R
E
C
E
I
V
E
T
R
A
N
S
MIT +
T
R
A
N
S
MIT
G
ND/
S
HI
E
L
D
D
A
T
A
OUT
NO.
1
NO.
2
NO.
3
NO.
4
NO.
5
NO.
6
NO.
7
NO.
8
NO.
1
NO.
2
NO.
3
NO.
4
NO.
5
NO.
6
NO.
7
NO.
8
A
CTI
V
E
L
O
A
D
L
E
D
S
3550
S
O.
700
W
E
S
T •
S
L
C., UT
A
H
84119
(
801
)
268
-
8668
F
A
X
(
801
)
268
-
9200
• T
E
CH HOT
L
IN
E
1
-
800
-
527
-
5527
W
A
R
NIN
G
A
S
HO
R
T
E
D
L
O
A
D WI
LL
B
L
OW
F
U
S
E
A
ND C
A
N D
A
M
A
G
E
M ODU
L
E
.
THI
S
I
S
NOT CO
V
E
R
E
D
B
Y W
A
RR
A
NTY.
WI
R
E
R
A
N
G
E
10
-
16
A
W
G
.
TO
R
QU
E
10
-
12
IN.
L
B
S
.
60
c
M IN. COPP
E
R
WI
R
E
ON
L
Y
U
S
E
F
A
S
T
A
CTIN
G
20
A
MP
F
U
S
E
S
.
1
2
3
4
5
6
7
8
M
A
NU
A
L
O
FF
ON
S
E
RI
A
L
NO.
____________________________________
POWER
1
2
3
4
5
6
7
8
R
E
MOT
E
M
A
NU
A
L
ON
COMMON
C
D
imm er
OUTPUT 5
OUTPUT 6
OUTPUT 7
OUTPUT 8
INPUT 120VAC 6 0Hz
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
NEUTRAL
OUTPUT 1
OUTPUT 2
OUTPUT 3
OUTPUT 4
6800-270
®
®
LISTED
71TO
IND. CONT. EQ.
1
s
t
DI
G
IT
2
n
d
DI
G
IT
A
DD
R
E
SS
S
WITCH
E
S
A
DD
R
E
SS
R
A
T
E
D
20
A
MP
S
TOT
A
L
,
12 0
V
O
L
T
S
TUN
G
S
T
E
N
NOT TO
E
XC
EE
D
16
A
MP
S
ON
A
NY
S
IN
G
L
E
OUTPUT
C
A
UTION
R
I
S
K
O
F
E
L
E
CT
R
IC
A
L
S
HOC
K
. H
E
A
T
S
IN
K
I
S
L
I
V
E
. DI
S
CONN
E
CT
F
R
OM POW
E
R
B
E
F
O
R
E
S
E
R
V
ICIN
G
.
®
1
2
3
4
5
R
E
C
E
I
V
E
+
R
E
C
E
I
V
E
T
R
A
N
S
MIT +
T
R
A
N
S
MIT –
G
ND/
S
HI
E
L
D
D
A
T
A
IN
1
2
3
4
5
R
E
C
E
I
V
E
+
R
E
C
E
I
V
E
T
R
A
N
S
MIT +
T
R
A
N
S
MIT
G
ND/
S
HI
E
L
D
D
A
T
A
OUT
NO.
1
NO.
2
NO.
3
NO.
4
NO.
5
NO.
6
NO.
7
NO.
8
NO.
1
NO.
2
NO.
3
NO.
4
NO.
5
NO.
6
NO.
7
NO.
8
A
CTI
V
E
L
O
A
D
L
E
D
S
3550
S
O.
700
W
E
S
T •
S
L
C., UT
A
H
84119
(
801
)
268
-
8668
F
A
X
(
801
)
268
-
9200
• T
E
CH HOT
L
IN
E
1
-
800
-
527
-
5527
W
A
R
NIN
G
A
S
HO
R
T
E
D
L
O
A
D WI
LL
B
L
OW
F
U
S
E
A
ND C
A
N D
A
M
A
G
E
M ODU
L
E
.
THI
S
I
S
NOT CO
V
E
R
E
D
B
Y W
A
RR
A
NTY.
WI
R
E
R
A
N
G
E
10
-
16
A
W
G
.
TO
R
QU
E
10
-
12
IN.
L
B
S
.
60
c
M IN. COPP
E
R
WI
R
E
ON
L
Y
U
S
E
F
A
S
T
A
CTIN
G
20
A
MP
F
U
S
E
S
.
1
2
3
4
5
6
7
8
M
A
NU
A
L
O
FF
ON
S
E
RI
A
L
NO.
____________________________________
POWER
1
2
3
4
5
6
7
8
R
E
MOT
E
M
A
NU
A
L
ON
COMMON
C
D
imm er
R
WIRE RANGE 10-16 AWG.
TORQUE 7 IN. LBS.
60 c MIN. COPPER WIRE ONLY
CAUTION: RISK OF ELECTICAL SHOCK. HEAT SINK
IS LIVE. DISCONNECT AT POWER BEFORE SERVICING.
A SHORTED LOAD WILL BLOW FUSE AND
CAN DAMAGE MODULE. THIS IS NOT
COVERED BY WARRANTY.
WHEN DRIVING TRANSFORMER COUPLED
LOADS, THE ACTUALLOAD WATTAGE MUST
BE AT LEAST 60% OF THE TRANSFORMERS V/A
RATING OR TRANSFORMER HUM, FLASHING
AND/OR DAMAGE MAY OCCUR.
TO AVOID POSSIBLE DAMAGE TO MODULE, AC POWER
MUST BE REMOVED BEFORE CONNECTING OR
DISCONNECTING LOADS.
MFG. CODE
Label P/N 6800-258.01
ADDRESS
MANUAL
ON
ACTIVE
OUTPUT
LEDS
MANUAL
REMOTE
ON
INPUT120 VAC
60 Hz.
LOAD TYPELOAD TYPE
TUNGSTENTUNGSTEN
RELAY RATINGRELAY RATING
15 A/120 VAC MAX. PER OUTPUT
20 A/120 VAC MAX. PER OUTPUT
40 A/120 VAC MAX. PER OUTPUT
15 A/120 VAC MAX. PER OUTPUT
20 A/120 VAC MAX. PER OUTPUT
40 A/120 VAC MAX. PER OUTPUT
USE SLOW BLOW 15 AMP FUSES.
D
imm er
R
WIRE RANGE 10-16 AWG.
TORQUE 7 IN. LBS.
60 c MIN. COPPER WIRE ONLY
CAUTION: RISK OF ELECTICAL SHOCK. HEAT SINK
IS LIVE. DISCONNECT AT POWER BEFORE SERVICING.
A SHORTED LOAD WILL BLOW FUSE AND
CAN DAMAGE MODULE. THIS IS NOT
COVERED BY WARRANTY.
WHEN DRIVING TRANSFORMER COUPLED
LOADS, THE ACTUALLOAD WATTAGE MUST
BE AT LEAST 60% OF THE TRANSFORMERS V/A
RATING OR TRANSFORMER HUM, FLASHING
AND/OR DAMAGE MAY OCCUR.
TO AVOID POSSIBLE DAMAGE TO MODULE, AC POWER
MUST BE REMOVED BEFORE CONNECTING OR
DISCONNECTING LOADS.
MFG. CODE
Label P/N 6800-258.01
ADDRESS
MANUAL
ON
ACTIVE
OUTPUT
LEDS
MANUAL
REMOTE
ON
INPUT120 VAC
60 Hz.
LOAD TYPELOAD TYPE
TUNGSTENTUNGSTEN
RELAY RATINGRELAY RATING
15 A/120 VAC MAX. PER OUTPUT
20 A/120 VAC MAX. PER OUTPUT
40 A/120 VAC MAX. PER OUTPUT
15 A/120 VAC MAX. PER OUTPUT
20 A/120 VAC MAX. PER OUTPUT
40 A/120 VAC MAX. PER OUTPUT
USE SLOW BLOW 15 AMP FUSES.
D
imm er
R
WIRE RANGE 10-16 AWG.
TORQUE 7 IN. LBS.
60 c MIN. COPPER WIRE ONLY
CAUTION: RISK OF ELECTICAL SHOCK. HEAT SINK
IS LIVE. DISCONNECT AT POWER BEFORE SERVICING.
A SHORTED LOAD WILL BLOW FUSE AND
CAN DAMAGE MODULE. THIS IS NOT
COVERED BY WARRANTY.
WHEN DRIVING TRANSFORMER COUPLED
LOADS, THE ACTUALLOAD WATTAGE MUST
BE AT LEAST 60% OF THE TRANSFORMERS V/A
RATING OR TRANSFORMER HUM, FLASHING
AND/OR DAMAGE MAY OCCUR.
TO AVOID POSSIBLE DAMAGE TO MODULE, AC POWER
MUST BE REMOVED BEFORE CONNECTING OR
DISCONNECTING LOADS.
MFG. CODE
Label P/N 6800-258.01
ADDRESS
MANUAL
ON
ACTIVE
OUTPUT
LEDS
MANUAL
REMOTE
ON
INPUT120 VAC
60 Hz.
LOAD TYPELOAD TYPE
TUNGSTENTUNGSTEN
RELAY RATINGRELAY RATING
15 A/120 VAC MAX. PER OUTPUT
20 A/120 VAC MAX. PER OUTPUT
40 A/120 VAC MAX. PER OUTPUT
15 A/120 VAC MAX. PER OUTPUT
20 A/120 VAC MAX. PER OUTPUT
40 A/120 VAC MAX. PER OUTPUT
USE SLOW BLOW 15 AMP FUSES.
D
imm er
R
WIRE RANGE 10-16 AWG.
TORQUE 7 IN. LBS.
60 c MIN. COPPER WIRE ONLY
CAUTION: RISK OF ELECTICAL SHOCK. HEAT SINK
IS LIVE. DISCONNECT AT POWER BEFORE SERVICING.
A SHORTED LOAD WILL BLOW FUSE AND
CAN DAMAGE MODULE. THIS IS NOT
COVERED BY WARRANTY.
WHEN DRIVING TRANSFORMER COUPLED
LOADS, THE ACTUALLOAD WATTAGE MUST
BE AT LEAST 60% OF THE TRANSFORMERS V/A
RATING OR TRANSFORMER HUM, FLASHING
AND/OR DAMAGE MAY OCCUR.
TO AVOID POSSIBLE DAMAGE TO MODULE, AC POWER
MUST BE REMOVED BEFORE CONNECTING OR
DISCONNECTING LOADS.
MFG. CODE
Label P/N 6800-258.01
ADDRESS
MANUAL
ON
ACTIVE
OUTPUT
LEDS
MANUAL
REMOTE
ON
INPUT120 VAC
60 Hz.
LOAD TYPELOAD TYPE
TUNGSTENTUNGSTEN
RELAY RATINGRELAY RATING
15 A/120 VAC MAX. PER OUTPUT
20 A/120 VAC MAX. PER OUTPUT
40 A/120 VAC MAX. PER OUTPUT
15 A/120 VAC MAX. PER OUTPUT
20 A/120 VAC MAX. PER OUTPUT
40 A/120 VAC MAX. PER OUTPUT
USE SLOW BLOW 15 AMP FUSES.
D
imm er
R
WIRE RANGE 10-16 AWG.
TORQUE 7 IN. LBS.
60 c MIN. COPPER WIRE ONLY
CAUTION: RISK OF ELECTICAL SHOCK. HEAT SINK
IS LIVE. DISCONNECT AT POWER BEFORE SERVICING.
A SHORTED LOAD WILL BLOW FUSE AND
CAN DAMAGE MODULE. THIS IS NOT
COVERED BY WARRANTY.
WHEN DRIVING TRANSFORMER COUPLED
LOADS, THE ACTUALLOAD WATTAGE MUST
BE AT LEAST 60% OF THE TRANSFORMERS V/A
RATING OR TRANSFORMER HUM, FLASHING
AND/OR DAMAGE MAY OCCUR.
TO AVOID POSSIBLE DAMAGE TO MODULE, AC POWER
MUST BE REMOVED BEFORE CONNECTING OR
DISCONNECTING LOADS.
MFG. CODE
Label P/N 6800-258.01
ADDRESS
MANUAL
ON
ACTIVE
OUTPUT
LEDS
MANUAL
REMOTE
ON
INPUT120 VAC
60 Hz.
LOAD TYPELOAD TYPE
TUNGSTENTUNGSTEN
RELAY RATINGRELAY RATING
15 A/120 VAC MAX. PER OUTPUT
20 A/120 VAC MAX. PER OUTPUT
40 A/120 VAC MAX. PER OUTPUT
15 A/120 VAC MAX. PER OUTPUT
20 A/120 VAC MAX. PER OUTPUT
40 A/120 VAC MAX. PER OUTPUT
USE SLOW BLOW 15 AMP FUSES.
D
imm er
R
WIRE RANGE 10-16 AWG.
TORQUE 7 IN. LBS.
60 c MIN. COPPER WIRE ONLY
CAUTION: RISK OF ELECTICAL SHOCK. HEAT SINK
IS LIVE. DISCONNECT AT POWER BEFORE SERVICING.
A SHORTED LOAD WILL BLOW FUSE AND
CAN DAMAGE MODULE. THIS IS NOT
COVERED BY WARRANTY.
WHEN DRIVING TRANSFORMER COUPLED
LOADS, THE ACTUALLOAD WATTAGE MUST
BE AT LEAST 60% OF THE TRANSFORMERS V/A
RATING OR TRANSFORMER HUM, FLASHING
AND/OR DAMAGE MAY OCCUR.
TO AVOID POSSIBLE DAMAGE TO MODULE, AC POWER
MUST BE REMOVED BEFORE CONNECTING OR
DISCONNECTING LOADS.
MFG. CODE
Label P/N 6800-258.01
ADDRESS
MANUAL
ON
ACTIVE
OUTPUT
LEDS
MANUAL
REMOTE
ON
INPUT120 VAC
60 Hz.
LOAD TYPELOAD TYPE
TUNGSTENTUNGSTEN
RELAY RATINGRELAY RATING
15 A/120 VAC MAX. PER OUTPUT
20 A/120 VAC MAX. PER OUTPUT
40 A/120 VAC MAX. PER OUTPUT
15 A/120 VAC MAX. PER OUTPUT
20 A/120 VAC MAX. PER OUTPUT
40 A/120 VAC MAX. PER OUTPUT
USE SLOW BLOW 15 AMP FUSES.
D
imm er
R
WIRE RANGE 10-16 AWG.
TORQUE 7 IN. LBS.
60 c MIN. COPPER WIRE ONLY
CAUTION: RISK OF ELECTICAL SHOCK. HEAT SINK
IS LIVE. DISCONNECT AT POWER BEFORE SERVICING.
A SHORTED LOAD WILL BLOW FUSE AND
CAN DAMAGE MODULE. THIS IS NOT
COVERED BY WARRANTY.
WHEN DRIVING TRANSFORMER COUPLED
LOADS, THE ACTUAL LOAD WATTAGE MUS T
BE AT LEAST 60% OF THE TRANSFORMERS V/A
RATING OR TRANSFORMER HUM, FLASHING
AND/OR DAMAGE MAY OCCUR.
TO AVOID POSSIBLE DAMAGE TO MODULE, AC POWER
MUST BE REMOVED BEFORE CONNECTING OR
DISCONNECTING LOADS.
MFG. CODE
Label P/N 6800-258.01
ADDRESS
MANUAL
ON
ACTIVE
OUTPUT
LEDS
MANUAL
REMOTE
ON
INPUT120 VAC
60 Hz.
LOAD TYPELOAD TYPE
TUNGSTENTUNGSTEN
RELAY RATINGRELAY RATING
15 A/120 VAC MAX. PER OUTPUT
20 A/120 VAC MAX. PER OUTPUT
40 A/120 VAC MAX. PER OUTPUT
15 A/120 VAC MAX. PER OUTPUT
20 A/120 VAC MAX. PER OUTPUT
40 A/120 VAC MAX. PER OUTPUT
USE SLOW BLOW 15 AMP FUSES.
D
imm er
R
WIRE RANGE 10-16 AWG.
TORQUE 7 IN. LBS.
60 c MIN. COPPER WIRE ONLY
CAUTION: RISK OF ELECTICAL SHOCK. HEAT SINK
IS LIVE. DISCONNECT AT POWER BEFORE SERVICING.
A SHORTED LOAD WILL BLOW FUSE AND
CAN DAMAGE MODULE. THIS IS NOT
COVERED BY WARRANTY.
WHEN DRIVING TRANSFORMER COUPLED
LOADS, THE ACTUAL LOAD WATTAGE MUS T
BE AT LEAST 60% OF THE TRANSFORMERS V/A
RATING OR TRANSFORMER HUM, FLASHING
AND/OR DAMAGE MAY OCCUR.
TO AVOID POSSIBLE DAMAGE TO MODULE, AC POWER
MUST BE REMOVED BEFORE CONNECTING OR
DISCONNECTING LOADS.
MFG. CODE
Label P/N 6800-258.01
ADDRESS
MANUAL
ON
ACTIVE
OUTPUT
LEDS
MANUAL
REMOTE
ON
INPUT120 VAC
60 Hz.
LOAD TYPELOAD TYPE
TUNGSTENTUNGSTEN
RELAY RATINGRELAY RATING
15 A/120 VAC MAX. PER OUTPUT
20 A/120 VAC MAX. PER OUTPUT
40 A/120 VAC MAX. PER OUTPUT
15 A/120 VAC MAX. PER OUTPUT
20 A/120 VAC MAX. PER OUTPUT
40 A/120 VAC MAX. PER OUTPUT
USE SLOW BLOW 15 AMP FUSES.
D
imm er
R
WIRE RANGE 10-16 AWG.
TORQUE 7 IN. LBS.
60 c MIN. COPPER WIRE ONLY
CAUTION: RISK OF ELECTICAL SHOCK. HEAT SINK
IS LIVE. DISCONNECT AT POWER BEFORE SERVICING.
A SHORTED LOAD WILL BLOW FUSE AND
CAN DAMAGE MODULE. THIS IS NOT
COVERED BY WARRANTY.
WHEN DRIVING TRANSFORMER COUPLED
LOADS, THE ACTUAL LOAD WATTAGE MUS T
BE AT LEAST 60% OF THE TRANSFORMERS V/A
RATING OR TRANSFORMER HUM, FLASHING
AND/OR DAMAGE MAY OCCUR.
TO AVOID POSSIBLE DAMAGE TO MODULE, AC POWER
MUST BE REMOVED BEFORE CONNECTING OR
DISCONNECTING LOADS.
MFG. CODE
Label P/N 6800-258.01
ADDRESS
MANUAL
ON
ACTIVE
OUTPUT
LEDS
MANUAL
REMOTE
ON
INPUT120 VAC
60 Hz.
LOAD TYPELOAD TYPE
TUNGSTENTUNGSTEN
RELAY RATINGRELAY RATING
15 A/120 VAC MAX. PER OUTPUT
20 A/120 VAC MAX. PER OUTPUT
40 A/120 VAC MAX. PER OUTPUT
15 A/120 VAC MAX. PER OUTPUT
20 A/120 VAC MAX. PER OUTPUT
40 A/120 VAC MAX. PER OUTPUT
USE SLOW BLOW 15 AMP FUSES.
D
imm er
R
WIRE RANGE 10-16 AWG.
TORQUE 7 IN. LBS.
60 c MIN. COPPER WIRE ONLY
CAUTION: RISK OF ELECTICAL SHOCK. HEAT SINK
IS LIVE. DISCONNECT AT POWER BEFORE SERVICING.
A SHORTED LOAD WILL BLOW FUSE AND
CAN DAMAGE MODULE. THIS IS NOT
COVERED BY WARRANTY.
WHEN DRIVING TRANSFORMER COUPLED
LOADS, THE ACTUAL LOAD WATTAGE MUS T
BE AT LEAST 60% OF THE TRANSFORMERS V/A
RATING OR TRANSFORMER HUM, FLASHING
AND/OR DAMAGE MAY OCCUR.
TO AVOID POSSIBLE DAMAGE TO MODULE, AC POWER
MUST BE REMOVED BEFORE CONNECTING OR
DISCONNECTING LOADS.
MFG. CODE
Label P/N 6800-258.01
ADDRESS
MANUAL
ON
ACTIVE
OUTPUT
LEDS
MANUAL
REMOTE
ON
INPUT120 VAC
60 Hz.
LOAD TYPELOAD TYPE
TUNGSTENTUNGSTEN
RELAY RATINGRELAY RATING
15 A/120 VAC MAX. PER OUTPUT
20 A/120 VAC MAX. PER OUTPUT
40 A/120 VAC MAX. PER OUTPUT
15 A/120 VAC MAX. PER OUTPUT
20 A/120 VAC MAX. PER OUTPUT
40 A/120 VAC MAX. PER OUTPUT
USE SLOW BLOW 15 AMP FUSES.
D
imm er
R
WIRE RANGE 10-16 AWG.
TORQUE 7 IN. LBS.
60 c MIN. COPPER WIRE ONLY
CAUTION: RISK OF ELECTICAL SHOCK. HEAT SINK
IS LIVE. DISCONNECT AT POWER BEFORE SERVICING.
A SHORTED LOAD WILL BLOW FUSE AND
CAN DAMAGE MODULE. THIS IS NOT
COVERED BY WARRANTY.
WHEN DRIVING TRANSFORMER COUPLED
LOADS, THE ACTUAL LOAD WATTAGE MUS T
BE AT LEAST 60% OF THE TRANSFORMERS V/A
RATING OR TRANSFORMER HUM, FLASHING
AND/OR DAMAGE MAY OCCUR.
TO AVOID POSSIBLE DAMAGE TO MODULE, AC POWER
MUST BE REMOVED BEFORE CONNECTING OR
DISCONNECTING LOADS.
MFG. CODE
Label P/N 6800-258.01
ADDRESS
MANUAL
ON
ACTIVE
OUTPUT
LEDS
MANUAL
REMOTE
ON
INPUT120 VAC
60 Hz.
LOAD TYPELOAD TYPE
TUNGSTENTUNGSTEN
RELAY RATINGRELAY RATING
15 A/120 VAC MAX. PER OUTPUT
20 A/120 VAC MAX. PER OUTPUT
40 A/120 VAC MAX. PER OUTPUT
15 A/120 VAC MAX. PER OUTPUT
20 A/120 VAC MAX. PER OUTPUT
40 A/120 VAC MAX. PER OUTPUT
USE SLOW BLOW 15 AMP FUSES.
D
imm er
R
WIRE RANGE 10-16 AWG.
TORQUE 7 IN. LBS.
60 c MIN. COPPER WIRE ONLY
CAUTION: RISK OF ELECTICAL SHOCK. HEAT SINK
IS LIVE. DISCONNECT AT POWER BEFORE SERVICING.
A SHORTED LOAD WILL BLOW FUSE AND
CAN DAMAGE MODULE. THIS IS NOT
COVERED BY WARRANTY.
WHEN DRIVING TRANSFORMER COUPLED
LOADS, THE ACTUAL LOAD WATTAGE MUS T
BE AT LEAST 60% OF THE TRANSFORMERS V/A
RATING OR TRANSFORMER HUM, FLASHING
AND/OR DAMAGE MAY OCCUR.
TO AVOID POSSIBLE DAMAGE TO MODULE, AC POWER
MUST BE REMOVED BEFORE CONNECTING OR
DISCONNECTING LOADS.
MFG. CODE
Label P/N 6800-258.01
ADDRESS
MANUAL
ON
ACTIVE
OUTPUT
LEDS
MANUAL
REMOTE
ON
INPUT120 VAC
60 Hz.
LOAD TYPELOAD TYPE
TUNGSTENTUNGSTEN
RELAY RATINGRELAY RATING
15 A/120 VAC MAX. PER OUTPUT
20 A/120 VAC MAX. PER OUTPUT
40 A/120 VAC MAX. PER OUTPUT
15 A/120 VAC MAX. PER OUTPUT
20 A/120 VAC MAX. PER OUTPUT
40 A/120 VAC MAX. PER OUTPUT
USE SLOW BLOW 15 AMP FUSES.
D
imm er
RECEIVE +RECEIVE +
11
RECEIVE -RECEIVE -
22
TRANSIT +TRANSIT +
33
TRANSIT -TRANSIT -
44
GND/SHIELDGND/SHIELD
55
RECEIVE +RECEIVE +
11
RECEIVE -RECEIVE -
22
TRANSIT +TRANSIT +
33
TRANSIT -TRANSIT -
44
GND/SHIELDGND/SHIELD
55
DATA INDATA IN
DATA OUTDATA OUT
ACTIVE
OUTPUT
LEDS
ACTIVE
OUTPUT
LEDS
MFG. CODEMFG. CODE
Label P/N 6800-266.01Label P/N 6800-266.01
LOAD TYPELOAD TYPE
GENERAL PURPOSEGENERAL PURPOSE
ADDRESS ADDRESS
S
W
I
T
C
H
ES
S
W
I
T
C
H
ES
1st 1st
DIGITDIGIT
2nd 2nd
DIGITDIGIT
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
COMMONCOMMON
MANUAL
REMOTE
ON
MANUAL
REMOTE
ON
CC
RELAY RATINGSRELAY RATINGS
12 A/120 VAC MAX. PER OUTPUT
96 A/120 VAC MAX. PER MODULE
12 A/120 VAC MAX. PER OUTPUT
96 A/120 VAC MAX. PER MODULE
A SHORTENED LO AD WILL BLOW F USE AND
CAN DAMAGE MODULE.
THIS IS NOT COVERED BY WARRANTY
A SHORTENED LO AD WILL BLOW F USE AND
CAN DAMAGE MODULE.
THIS IS NOT COVERED BY WARRANTY
WARNI NGWARNI NG
LINE 1 AND NEUTRAL 1 MUST BE
CONNECTED TO POWER THE MODULE
LINE 1 AND NEUTRAL 1 MUST BE
CONNECTED TO POWER THE MODULE
3400 SOUTH WEST TEMPLE SLC, UTAH 84115 (801) 486-8500 FAX 801-486-8569 3400 SOUTH WEST TEMPLE SLC, UTAH 84115 (801) 486-8500 FAX 801-486-8569 TECHNICAL SUPPORT 1-800-527-5527TECHNICAL SUPPORT 1-800-527-5527
NO. 1
NO. 2
NO. 3
NO. 4
NO. 5
NO. 6
NO. 7
NO. 8
NO. 1
NO. 2
NO. 3
NO. 4
NO. 5
NO. 6
NO. 7
NO. 8
MANUAL
ON
WIRE RANGE 10-16 AWG.
TORQUE 7 IN. LBS.
60 c MIN. COPPER WIRE ONLY.
WIRE RANGE 10-16 AWG.
TORQUE 7 IN. LBS.
60 c MIN. COPPER WIRE ONLY.
USE SLOW BLOW 12 AMP FUSES.USE SLOW BLOW 12 AMP FUSES.
NO. 1
NO. 2
NO. 3
NO. 4
NO. 5
NO. 6
NO. 7
NO. 8
NO. 1
NO. 2
NO. 3
NO. 4
NO. 5
NO. 6
NO. 7
NO. 8
MOTORMOTOR
1 HP @ 240 VAC PER CHANNEL
1/2 HP @ 120 VAC PER CHANNEL
1 HP @ 240 VAC PER CHANNEL
1/2 HP @ 120 VAC PER CHANNEL
POWERPOWER
ADDRESS
OFF/ON
1-2
3-4
5-6
7-8
1-2
3-4
5-6
7-8
OFF/ON
INTERLOCK
SWITCHES
NEUTRALNEUTRAL
LOAD NO.LOAD NO.
1
2
3
4
5
6
7
8
R
ela
y
RECEIVE +RECEIVE +
11
RECEIVE -RECEIVE -
22
TRANSIT +TRANSIT +
33
TRANSIT -TRANSIT -
44
GND/SHIELDGND/SHIELD
55
RECEIVE +RECEIVE +
11
RECEIVE -RECEIVE -
22
TRANSIT +TRANSIT +
33
TRANSIT -TRANSIT -
44
GND/SHIELDGND/SHIELD
55
DATA INDATA IN
DATA OUTDATA OUT
ACTIVE
OUTPUT
LEDS
ACTIVE
OUTPUT
LEDS
MFG. CODEMFG. CODE
Label P/N 6800-266.01Label P/N 6800-266.01
LOAD TYPELOAD TYPE
GENERAL PURPOSEGENERAL PURPOSE
ADDRESS ADDRESS
S
W
I
T
C
H
ES
S
W
I
T
C
H
ES
1st 1st
DIGITDIGIT
2nd 2nd
DIGITDIGIT
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
COMMONCOMMON
MANUAL
REMOTE
ON
MANUAL
REMOTE
ON
CC
RELAY RATINGSRELAY RATINGS
12 A/120 VAC MAX. PER OUTPUT
96 A/120 VAC MAX. PER MODULE
12 A/120 VAC MAX. PER OUTPUT
96 A/120 VAC MAX. PER MODULE
A SHORTENED LO AD WILL BLOW F USE AND
CAN DAMAGE MODULE.
THIS IS NOT COVERED BY WARRANTY
A SHORTENED LO AD WILL BLOW F USE AND
CAN DAMAGE MODULE.
THIS IS NOT COVERED BY WARRANTY
WARNI NGWARN ING
LINE 1 AND NEUTRAL 1 MUST BE
CONNECTED TO POWER THE MODULE
LINE 1 AND NEUTRAL 1 MUST BE
CONNECTED TO POWER THE MODULE
3400 SOUTH WEST TEMPLE SLC, UTAH 84115 (801) 486-8500 FAX 801-486-8569 3400 SOUTH WEST TEMPLE SLC, UTAH 84115 (801) 486-8500 FAX 801-486-8569 TECHNICAL SUPPORT 1-800-527-5527TECHNICAL SUPPORT 1-800-527-5527
NO. 1
NO. 2
NO. 3
NO. 4
NO. 5
NO. 6
NO. 7
NO. 8
NO. 1
NO. 2
NO. 3
NO. 4
NO. 5
NO. 6
NO. 7
NO. 8
MANUAL
ON
WIRE RANGE 10-16 AWG.
TORQUE 7 IN. LBS.
60 c MIN. COPPER WIRE ONLY.
WIRE RANGE 10-16 AWG.
TORQUE 7 IN. LBS.
60 c MIN. COPPER WIRE ONLY.
USE SLOW BLOW 12 AMP FUSES.USE SLOW BLOW 12 AMP FUSES.
NO. 1
NO. 2
NO. 3
NO. 4
NO. 5
NO. 6
NO. 7
NO. 8
NO. 1
NO. 2
NO. 3
NO. 4
NO. 5
NO. 6
NO. 7
NO. 8
MOTORMOTOR
1 HP @ 240 VAC PER CHANNEL
1/2 HP @ 120 VAC PER CHANNEL
1 HP @ 240 VAC PER CHANNEL
1/2 HP @ 120 VAC PER CHANNEL
POWERPOWER
ADDRESS
OFF/ON
1-2
3-4
5-6
7-8
1-2
3-4
5-6
7-8
OFF/ON
INTERLOCK
SWITCHES
NEUTRALNEUTRAL
LOAD NO.LOAD NO.
1
2
3
4
5
6
7
8
R
ela
y
6800-218
3550
SO
.
700
WEST
SL
C
.,
U
T
AH
84119
(801)
268-8 668
F
A
X
(801)
268-9200
TE
CH
H
OT
L
I
N
E
1-800-527- 5527
W
A
R
NIN
G
A
S
H
O
R
TE
D
LO
AD
W
I
LL
DA
M
A
G
E
M
O
DU
LE
.
T
H
I
S
I
S
N
OT
C
O
VE
R
E
D
B
Y
W
ARRAN
TY
.
TO
A
V
O
I
D
P
O
SS
I
B
LE
DA
M
A
G
E
TO
M
O
DU
LE
AC
P
O
WE
R
M
U
ST
B
E
R
E
M
O
VE
D
B
EF
O
R
E
C
O
NN
E
C
T
I
N
G
O
R
D
I
S
C
O
NN
E
C
T
I
N
G
LO
AD
S
.
R
A
TIN
G
S
P
R
IM
A
R
Y
:
2
A
MP
S
,
12 0
V
A
C M
A
X.
S
E
COND
A
R
Y
:
15
-
20
V
DC UN
R
E
G
U
L
A
T
E
D
N
e
u
t
r
a
l
120
V
A
C
60
HZ
N
e
u
t
r
a
l
120
V
A
C
60
HZ
W
I
R
E
RAN
G
E
10
-
16
A
W
G
.
/
TO
R
Q
U
E
10
-
12
I
N
.
L
B
S
.
/
60
M
I
N
.
C
O
PPE
R
W
I
R
E
O
N
LY
POW
E
R
DC P
o
s
.
DC C
om
.
F
U
S
E
A
G
C
5
A
mp
.
N
OT
U
SE
D
POW
E
R
DC P
o
s
.
DC C
om
.
F
U
S
E
A
G
C
5
A
mp
.
N
OT
U
SE
D
®
CC
DATE:
P
ower
6800-218
3550
SO
.
700
WEST
SL
C
.,
U
T
AH
84119
(801)
268-8 668
F
A
X
(801)
268-9200
TE
CH
H
OT
L
I
N
E
1-800-527- 5527
W
A
R
NIN
G
A
S
H
O
R
TE
D
LO
AD
W
I
LL
DA
M
A
G
E
M
O
DU
LE
.
T
H
I
S
I
S
N
OT
C
O
VE
R
E
D
B
Y
W
ARRAN
TY
.
TO
A
V
O
I
D
P
O
SS
I
B
LE
DA
M
A
G
E
TO
M
O
DU
LE
AC
P
O
WE
R
M
U
ST
B
E
R
E
M
O
VE
D
B
EF
O
R
E
C
O
NN
E
C
T
I
N
G
O
R
D
I
S
C
O
NN
E
C
T
I
N
G
LO
AD
S
.
R
A
TIN
G
S
P
R
IM
A
R
Y
:
2
A
MP
S
,
12 0
V
A
C M
A
X.
S
E
COND
A
R
Y
:
15
-
20
V
DC UN
R
E
G
U
L
A
T
E
D
N
e
u
t
r
a
l
120
V
A
C
60
HZ
N
e
u
t
r
a
l
120
V
A
C
60
HZ
W
I
R
E
RAN
G
E
10
-
16
A
W
G
.
/
TO
R
Q
U
E
10
-
12
I
N
.
L
B
S
.
/
60
M
I
N
.
C
O
PPE
R
W
I
R
E
O
N
LY
POW
E
R
DC P
o
s
.
DC C
om
.
F
U
S
E
A
G
C
5
A
mp
.
N
OT
U
SE
D
POW
E
R
DC P
o
s
.
DC C
om
.
F
U
S
E
A
G
C
5
A
mp
.
N
OT
U
SE
D
®
CC
DATE:
P
ower
Transorb
Board
Transorb
Board
Transorb
Board
Transorb
Board
From power supply to CCU
and control station connector(s)
TO FIRST ENCLOSURE
TRANSORB BOARD
From power supply to CCU
and control station connector(s)
TO CCU
,-$)./01('2-3)'*/&/3#
Red
Black
White (spare)
Green
Bare (shielded)
OUT IN
Transorb Board
Installation
!!
Transorb Board
Four-Module Enclosure
CAUTION: Before removing or installing a Transorb board in the Enclosure,
disconnect all the power.
To install the Transorb board do the following:
1. Remove theTransorb board from the anti-static bag .
2. Place the Transorb board in the enclosure.
3. Using the screws supplied, screw the Transorb board into the Enclosure with a Phillips head
screwdriver.
Grounding Procedure
To avoid damage from electrostatic discharge (ESD) when handling boards, use a grounding
strap as shown below:
Observe the following precautions to prevent ESD discharge damage:
1. Use an approved ESD wrist grounding strap or an approved wrist or ankle strap. Ensure
the grounding strap makes good skin contact.
2. Before installing or removing a Savant Transorb board, connect the clip end of the ground
strap to a grounded surface.
If you plan to return a replaced Transorb board to Savant Systems LLC: While wearing the
grounded strap, place the board in the anti-static bag that it was originally shipped in or any
static shielding bag to avoid ESD damage to the board.
NOTE: The wrist strap only protects the component from ESD voltages on the body; ESD
voltages on clothing can still cause damage.
CAUTION: Keep these wires on their respective side of the enclosure. Do not
cross over or under the voltage barrier with wires.
Additional Documentation
Additional Documentation is available at: dealers.SavantSystems.com
Knowledge Base > Savant Hardware > Lighting Control > Enclosures
009-0815-01
ENC-TRANS-00
120612
Copyright © 2012 Savant Systems, LLC. SAVANT and RacePoint Blueprint are trademarks of Savant Systems, LLC.
All brand names, product names and trademarks are the property of their respective owners.
Savant Systems, LLC reserves the right to change product specifications without notice.
/