General warnings
Important personal safety instructions: READ CAREFULLY!
Installation, programming, commissioning and maintenance must only be performed by qualified and experi-
enced personnel in compliance with applicable regulations.
Wear antistatic shoes and clothing if working on the control board.
Keep hold of these warnings.
Always disconnect the electrical power supply during cleaning or maintenance.
This product should only be used for the purpose for which it was explicitly designed. Any other use is con-
sidered dangerous.
The manufacturer declines all liability for any damage as a result of improper, incorrect or unreasonable use.
This product complies with the relevant directives in force.
Decommissioning and disposal. Dispose of the packaging and the device at the end of its life cycle responsibly,
in compliance with the laws in force in the country where the product is used. The recyclable components are
marked with a symbol and the material’s ID marker.
THE DATA AND INFORMATION SHOWN IN THIS MANUAL ARE TO BE CONSIDERED AS SUBJECT TO CHANGE AT ANY TIME AND WITHOUT THE NEED
FOR ANY ADVANCE WARNING.
MEASUREMENTS, UNLESS OTHERWISE INDICATED, ARE IN MILLIMETRES.
PACKAGE CONTENTS
Package contents
- CD with the software GSMManager, “Installation Ma-
nual” “Setting Manual” and “Software Manual GSM-
Manager,
- Interface module BXRS2301.
y Note
For a more detailed explanation about all the parameters mentioned below, refer to the “Setting Manual”
or the “Installation Manual”.
CN1
RS 232
RX
TX
CN1
RS 232
TX
RX
Cavo seriale
NON INCLUSO
per connessione a PCl
Connessione
al combinatore
1 - DCD
2 - RX
3 - TX
4 - DTR
5 - GND
6 - DSR
7 - RTS
8 - CTS
9 - RI
12345
6
F
789
A
B
Page 3 - Manual FA00538-EN - vers. 1 - 02/2017- © Came S.p.A. - The contents of the manual are to be considered as subject to change at any time and without the need for any advance warning.
SOFTWARE INSTALLATION
The GSM series diallers were created to be programmed also via a PC interface.
This setting mode makes device configuration quicker and more complete.
The software is installed on the PC by copying the folder “GSMManager” from the installation CD to the PC folder
to be used for the purpose.
Once the GSMManager application is installed, a serial connection must be created between the PC and the dialler.
This connection must be made using the dedicated interface module supplied with the software and a standard
serial cable (not included in the package).
If the dialler connection was made correctly, launching the application “GSMManager.exe” will permit accessing
the setting mode.
To make the PC connection, instead of using an RS232 serial cable connected directly to the socket on the module
A, you can also use the terminals TX, RX, –, making sure that the wiring is as shown in figure B.
Serial cable (not included) for
PC connection
To the dialler
(connector CN6)
Dialler connection
Serial cable NOT
INCLUDED for PC
connection
1
2
3
A
B
C
D
Page 4 - Manual FA00538-EN - vers. 1 - 02/2017- © Came S.p.A. - The contents of the manual are to be considered as subject to change at any time and without the need for any advance warning.
ACCESS TO SETTING
From the main screen, from the dropdown menu [DE-
VICE] select [COMMUNICATION PORT] [SEARCH] to
identify the serial port used for the communication A.
Once the communication port is identified, select
[ENABLE COMMUNICATION] to connect to the dialler.
Upon activation of communication, the [MASTER
CODE] (default 111999) will be requested B.
Once communication is activated, [RECEIVE CONFIGU-
RATION] makes it possible to import the setting from
the PC to the dialler.
If this is modified to update the dialler, use [SEND CON-
FIGURATION] 1.
Once configuration is complete, to deactivate the com-
munication use [DISABLE COMMUNICATION] 2.
GSMManager may work in a connected or non con-
nected mode with the dialler.
When working in non connected mode, the type of dial-
ler can be selected from the menu [DEVICE TYPE] 3
and the configuration file (.ccf) to be used subsequently
can be saved on your PC.
4
E
A
B
Page 5 - Manual FA00538-EN - vers. 1 - 02/2017- © Came S.p.A. - The contents of the manual are to be considered as subject to change at any time and without the need for any advance warning.
Using the dropdown menu [LANGUAGE] 4 you can se-
lect the desired software setting language B.
SETTING PARAMETER CONFIGURATION
Enabled
To arm/disarm the system, press [ENABLED] A.
Once the communication is activated, the configuration
parameters listed below can be configured.
- [DEFINITION OF THE MASTER CODE]
- [USER SETTINGS]
- [CUSTOMISING SMS]
- [INPUT SETTING]
- [OUTPUT SETTING]
- [GENERAL SETTING CONFIGURATION]
- [DATE / TIME SETTING]
- [EVENT MEMORY CONSULTATION]
Master Code
Select the menu [MASTER CODE] (default 111999) to
modify the default master code required to access set-
ting B.
Save your selections with [OK].
To exit the menu without saving, select [CANCEL].
A
B
3
C
Page 6 - Manual FA00538-EN - vers. 1 - 02/2017- © Came S.p.A. - The contents of the manual are to be considered as subject to change at any time and without the need for any advance warning.
User Configuration
Select the menu [USER CONFIG.] 1.
A window will appear with the number of available users 2 and all parameters that can be configured for each
individual user 3.
The parameters that can be configured are:
- [CODE]
- [PHONE],
- [PRIORITY],
- [PROVIDER SMS],
- [INPUT1-2-3-4],
- [TAMPER],
- [POWER FAULT],
- [BATTERY FAULT],
- [RESTORED TAMPER],
- [RESTORED POWER],
- [GSM LOW SIGNAL],
- [PERIODIC MESSAGE],
- [CLIP FUNCTION]
- [CLIP NOTIFICATION].
4EG
FH
D
Figura 13
9JK
E
Page 7 - Manual FA00538-EN - vers. 1 - 02/2017- © Came S.p.A. - The contents of the manual are to be considered as subject to change at any time and without the need for any advance warning.
[CODE]
In this field D a system arming/disarming code can
be assigned to a specific user for the selected system.
[PHONE]
In this field E you can enter the telephone number to
which the alarm messages defined for this user will be
sent, according to the methods selected for him.
The telephone number must be in the format
+393335555555.
[PRIORITY]
From this dropdown menu F it is possible to attribute
a priority level (1, 2 or 3) to each user.
[PROVIDER SMS]
Selecting this option G you can establish for each
user if he may or may not receive [PROVIDER SMS]
(for example, credit messages).
[INPUT 1, 2, 3, 4]
From this dropdown menu H you can define the me-
thod used to notify events to the specific user.
[TAMPER] [POWER FAULT]
[BATTERY FAULT] [RESTORED POWER]
[RESTORED TAMPER]
[GSM LOW SIGNAL] [PERIODIC TEST]
In these dropdown menus I you can define the me-
thod used to notify events to the specific user.
[CLIP FUNCTION]
From this dropdown menu J it is possible to remotely
activate an output remote control function at zero cost
with a single ring to the dialler.
[CLIP NOTIFICATION]
For the above described function, it is also possible,
with the dropdown menu, K to define the type of con-
firmation to send, if necessary, to the user who sent
the clip command.
Save your selections with [OK].
To exit the menu without saving, select [CANCEL].
F
23
1
G
Page 8 - Manual FA00538-EN - vers. 1 - 02/2017- © Came S.p.A. - The contents of the manual are to be considered as subject to change at any time and without the need for any advance warning.
SMS Setting
This field, [SMS SETTING], makes it possible to custo-
mise the SMS text of the alarm messages that will be
sent to the users (maximum 20 characters).
Save your selections with [OK].
To exit the menu without saving, select [CANCEL].
Input CONFIGURATION
Select the menu [INPUT CONFIGURATION] 1.
A window will appear with the number of inputs B and all parameters that can be configured for each individual
input 3.
The parameters that can be configured are:
- [TYPE]
- [FUNCTION]
- [DELAYED]
- [RESTORING SMS]
- [ENABLING]
- [PARTIAL ARMING INCLUDED]
- [FILTER]
4 5
G
FH I J
H
I
Page 9 - Manual FA00538-EN - vers. 1 - 02/2017- © Came S.p.A. - The contents of the manual are to be considered as subject to change at any time and without the need for any advance warning.
[TYPE]
From this dropdown menu 4 you can define the type
of transition of the input signal that the dialler inter-
prets as an alarm signal.
[FUNCTION]
From this dropdown menu 5 you can define the type
of function that follows the input.
[DELAYED]
Selecting this option 6 you can define if the input will
have a delay upon arming or when sending the alarm.
[RESTORING SMS]
Selecting this option 7 you can select if the dialler
sends a notification via SMS Restore Msg of input at
rest status.
[ENABLING]
Selecting this option 8 you can select whether or not
to enable an input.
[PARTIAL ARMING INCLUDED]
By ticking this menu 9 you can select if the input must
be included or not in the list of inputs specified for par-
tial arming.
[FILTER]
With this menu J you can define if the dialler must ap-
ply an alarm filter (0-250 seconds) to the alarm signal.
Save your selections with [OK].
To exit the menu without saving, select [CANCEL].
12
3
J
456
K
Page 10 - Manual FA00538-EN - vers. 1 - 02/2017- © Came S.p.A. - The contents of the manual are to be considered as subject to change at any time and without the need for any advance warning.
Output CONFIGURATION
Select the menu [OUTPUT CONFIGURATION] A.
A window will appear with the number of available ou-
tputs B and all parameters that can be configured for
each output C.
The parameters that can be configured are:
- [TYPE]
- [FUNCTION]
- [ON]
[TYPE]
From this menu 4 you can define the type of operation
for that output (follow or impulsive).
y Note
Value 0 indicates that the output is a [FOLLOW] type.
By selecting this value, the output will repeat exactly
the status of the activation event.
Any other value, between 1 and 255, indicates that
the output is [IMPULSIVE]. This value indicates the
length of the impulse.
[FUNCTION]
From this dropdown menu 5 you can select the event
that will enable the output.
[ON]
By ticking this menu 6 you can select whether or not
to enable an output.
Save your selections with [OK].
To exit the menu without saving, select [CANCEL].
1
L
2
3
M
N
Page 11 - Manual FA00538-EN - vers. 1 - 02/2017- © Came S.p.A. - The contents of the manual are to be considered as subject to change at any time and without the need for any advance warning.
Parameters
Select the menu [GENERAL SETTINGS] A.
The parameters that can be configured are:
- [LANGUAGE]
- [CYCLICAL CALLING]
- [END CYCLE]
- [CALLS NUMBER]
- [CALLS BREAK]
- [ADDRESS MESSAGE]
- [IN/OUT DELAY]
- [PERIODIC MESSAGE]
- [DISPLAYING NUMBER]
- [POS. FAULT RELAY]
- [PROVIDER FORWARDING]
- [PROVIDER NUMBER]
[LANGUAGE]
From this dropdown menu B you can select the lan-
guage desired for dialler operation.
[CYCLICAL CALLING]
From this dropdown menu C you can define the be-
haviour of the dialler if the user does not respond to an
alarm call.
4
5
6
G
H
I
J
O
P
Q
Page 12 - Manual FA00538-EN - vers. 1 - 02/2017- © Came S.p.A. - The contents of the manual are to be considered as subject to change at any time and without the need for any advance warning.
[END CYCLE]
From this dropdown menu 4 you can define if the
dialler will interrupt the calling sequence when the
first user is notified or if it will continue to call also
the subsequent users unless explicitly interrupted by a
user with the DTMF command (command 99).
y Note
If you’re using only the notification via [SMS] with
[END CYCLE] set to [YES], the cycle ends with the
first notified user. We suggest, therefore to use, at
least for the first user, the notification by voice call.
[CALLS NUMBER]
From this menu 5 you can select the number of call
attempts (1-10) or the number of cycles to the users in
the case of an alarm call.
[CALLS BREAK]
From this menu 6 you can select the time (0-255 se-
conds) that must pass between alarm calls.
[ADDRESS MESSAGE]
From this dropdown menu 7 you can define if the
voice alarm message, which is sent when there is an
alarm, should identify the system.
[IN/OUT DELAY]
From this menu 8 you can define an in/out activation
delay.
[PERIODIC MESSAGE]
From this menu 9 you can set how often the dialler
should send the periodic test message.
[DISPLAYING NUMBER]
From this menu J you can decide if the dialler number
is shown to the user who receives the alarm call.
K
L
M
R
S
T
Page 13 - Manual FA00538-EN - vers. 1 - 02/2017- © Came S.p.A. - The contents of the manual are to be considered as subject to change at any time and without the need for any advance warning.
[POSITIVE FAULT. RELAY]
From this menu K you can define the type of operation
of the failure output.
[PROVIDER FORWARDING]
From this menu L you can define if the dialler should
send the messages originating from the provider to the
enabled users or not.
[PROVIDER NUMBER]
In this menu M you can enter the telephone number of
the provider of reference (for example +404 for VODA-
FONE, +40916 for TIM and +155 for WIND).
Save your selections with [OK].
To exit the menu without saving, select [CANCEL].
A
B
C
1
U
V
Page 14 - Manual FA00538-EN - vers. 1 - 02/2017- © Came S.p.A. - The contents of the manual are to be considered as subject to change at any time and without the need for any advance warning.
Date and Time
Select the menu [DATE/TIME] A.
This function makes it possible to set the date and time
of the system in a very intuitive manner.
Save your selections with [OK].
To exit the menu select [CANCEL].
EventS
Select the menu [EVENTS] A.
With this menu B you can manage the system memo-
ry that can contain a maximum of 50 events.
To reset the [EVENT LOG] click on [CLEAR] C.
y Note
The dialler’s [EVENT LOG] can only be reset using
the software [GSMMANAGER].
To exit the menu select [CANCEL].
Page 15 - Manual FA00538-EN - vers. 1 - 02/2017- © Came S.p.A. - The contents of the manual are to be considered as subject to change at any time and without the need for any advance warning.
Came S.p.A.
Via Martiri Della Libertà, 15 Via Cornia, 1/b - 1/c
31030 Dosson di Casier
Treviso - Italy
33079 Sesto al Reghena
Pordenone - Italy
(+39) 0422 4940
(+39) 0422 4941
(+39) 0434 698111
(+39) 0434 698434
www.came.com
English - Manual FA00538-EN - vers. 1 - 02/2017 - © Came S.p.A.
The contents of the manual are to be considered as subject to change at any time and without the need for any advance warning.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

CAME 64440060 Software Manual

Type
Software Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI