RAIS Geo Instructions For Installation, Use And Maintenance Manual

Type
Instructions For Installation, Use And Maintenance Manual

This manual is also suitable for

ENGLISH RAISmanualforRaisGeo
1
INSTRUCTIONSFORINSTALLATION,
USEANDMAINTENANCE
RAISGEO
IMPORTANTINFORMATION
Onfirstlightingthestoveyoumustbecarefuln ottotoucht hepainted
surfacesanditisMOSTIMPORTANTthatthedooriskeptslightly‘ajarin
orderforthedoorsealandsealanttocure.
Thiswillpreventthedoorsealstickingtothepaintedbo dyandbecoming
damaged.
ENGLISH RAISmanualforRaisGeo
2
ENGLISH RAISmanualforRaisGeo
3
INTRODUCTION...………………………………………………………….. 4
WARRANTY..……………………………… …………………….………….. 4
SPECIFICATIONS……………………………………………… ………….. 5
CONVECTION………………………………………………………………. 6
INSTALLATIONINSTRUCTIONS ………………………………….……… 7
CHIMNEY………………………………………………………….…………. 89
INSTALLATION…………………………… ………………………………... 10
INSTALLATIONWITHTURNTABLE….…………………………………. 1119
INSTALLATIONDISTANCETOCOMBU STIBLEWALL……………… 20
CORNERINSTALLATION45°…………….………………………………. 21
INSTALLATIONDISTANCETONONCO MBUSTIBLEWALL………. 22
FORTHEINSTALLER……………………………………………………… 23
OPERATINGINSTRUCTIONS…………………………………………….. 24
FUEL…………………………………………………………………………... 24
DRYINGANDSTORAGE…………………………………………………… 25
REGULATIONOFCOMBUSTIONAIR…………………………………… 26
USINGTHEWOODBURNINGSTOVE…………………………………… 27
ADJUSTMENTOFAIRDAMPER…………………………………………. 27
CONTROL………………………………… ………………………………….. 27
FIRSTUSAGE………………………………………………………………… 28
LIGHTINGANDFUELLING………………………………………………… 2930
CLEANINGANDCARE………………… ………………………………….. 31
CLEANINGOFTHEFLUEWAYS………………………………………… 32
PROBLEMSOLVING……………………………………………………….. 33
ACCESSORIESANDSPAREPARTS……………………………………. 34
SPAREPARTDIAGRAMRAISTOPAS…….………...…………………. 3435
SPAREPARTDIAGRAMRAISOPUS……....…………………………… 3637
Revision:
Date :2011
RaisGeo
ENGLISH RAISmanualforRaisGeo
4
ARaiswoodburningstoveismorethanjustaheatsource:i talsoshowsthatyoucare
aboutdesignandqualityinyourhome.
Tomakethemostofyourwoodburningstoveitisimportantthatyoureadthemanual
thoroughlybeforeinstallingandusingit.
Inthecaseofwarrantycoverage,andforgeneralqueriesregardingyourwoodburn
ingstove,itisimportantthatyouknowthestove’sproductionnumber.
Wethereforerecommendthatyounotedownthenumberinthetablebelow.
Theproductionnumberislocatedinthetopoftheconvectio nbox.
Warranty
YourRaiswoodburningstovecomeswitha5yearwarranty.
Thewarranty,however,doesnotcoverheatinsulatingmaterials,glassandseals.
TheseareavailabletoorderfromyourlocalRaisdealer/stockist.
Anyalterationsmadetothestovewillvoidthewarranty.
Introduction
ThankyouforpurchasingaRaiswoodburningstove.
TheseapplianceshavebeenapprovedbyHETASas
intermittentoperatingappliancesforburningwoodlogsonl y.
ENGLISH RAISmanualforRaisGeo
5
RAISGEO161 RAISGEO126
Nominaloutput(kW): 5 5
Min./Max.output( kW): 38 38
Heatingarea(m
2
): Approx100 Approx100
Size,widt h/depth/height(mm): 490/490/1610 490/490/1260
Combustionchamberwidth/depth/height(mm). 288/288/500 288/288/500
Recommendedamountofwoodwhenfuelling(kg)
(Basedon2  3logsofwoodapprox.25cm)
1.6 1.6
Min.uptake/Min.draught(Pascal): 12 12
Weight(kg):  450 450
Efficiency(%): 79 79
ParticlesafterNS3058/3059(g/kg): 3.95 3.95
DustmeasuredaccordingtoDin+(mg/Nm
3
):
Smokegasmassflow(g/s): 5 5
Smokegastemperature(°C): 274 274
Intermittentoperation: Fuellingshouldbeundertaken
within3hours
Specifications
ENGLISH RAISmanualforRaisGeo
6
Thestovesareequippedwithcooldoorhandles  aRaisspecialfeature whichmeans
youcouldalmostdoawaywithgloves.Beaware,however,thatallexteriorsurfaces
becomehotduringuse  sotakeextremecare.
Convection
Raisstovesareconvectionstoves.Thismeansthatthestove’sbackandsidepanelsare
notoverheated.Convectionmeansthatthereisacirculationofair,whichensuresthat
theheatisdistributedmoreevenlythroughoutthee ntireroom.Thecoldairissuckedinat
thebaseofthestoveandupthroughtheconvectionchannel,whichrunsalongthe
stove’scombustionchamber.Theheatedaircomesoutatt hetopofthestove,which
ensuresacirculationofwarmairthroughouttheroom.
ENGLISH RAISmanualforRaisGeo
7
InstallationInstructions
Thefollowingpagesgiveinstructionsforthesafeandpro perinstall ationofthisheating
applianceintheUK.Theseinstructionscoverthebasicprinciplesofinstallation,
althoughsomedetailsmayneedslightmodificationtosuitparticularlocalsiteconditions.
InallcasestheinstallationmustcomplywithcurrentUKBuildingRegulations,Local
AuthorityByelawsandotherspecificationsorregulationsastheyaffecttheinstallationof
thestove.
PleasenotethatitisalegalrequirementunderEnglandandWalesBuildingRegulations
thattheinstallationofthestoveiseithercarriedoutunderlocalAuthorityBuilding
ControlapprovalorisinstalledbyaCompetentPersonregisteredwithaGovernment
approvedCompetentPersonsScheme.HETASoperatesuchaschemeandalistingof
theirregisteredCompetentPersonscanbefoundontheirwebsiteatwww.hetas.co.uk.
ItshouldbenotedthatthecurrentBuildingRegulationsrequirementsaregivenin
ApprovedDocumentJ.Theserequirementsmayalsobemetbyadoptingt herelevant
recommendationsgiveninBritishStandardsBS8303,BS6461andBS7566.
WARNING.HealthandSafetyAdviceNotice.
TheinstallationofthisheatingapplianceisgovernedbytheHealthandSafetyatWork
Act1974.itistheresponsibilityoftheinstallertoensurethatallrequirementsofthisAct
aremetduringtheinstallationworks.Attentionisdrawninparticulartothefollowing:
Handling: Theapplianceisaheavyitemandadequatefacilitiesmustbeavailable
forloading,unloadingandsitehandling.
FireCement: Sometypesoffirecementarecausticandshouldnotbeallowedtocome
intocontactwiththeskin.Protectiveglovesshouldbewornwhen
handlingfirecement.Incaseofcontactwiththeskin,washimmediately
withplentyofwater.
Asbestos: Thisstovecontainsnoasbestos.Ifthereisapossibilityofdisturbingany
asbestosinthecourseoftheinstallation,thenpleaseseekspecialist
guidanceanduseappropriateprotectiveequipment.
MetalParts: Wheninstalli ngorservicingthisstovecareshouldbetakentoavoidthe
possibilityofpersonalinjury.
ImportantWarning  PreparatoryWorkandsafetyChecks:
· Thisstovemustnotbeinstalledintoachimneywhichservesanyotherheating
appliance.
· Theremustnotbeanextractorfanfittedinthesameroomasthestove,asthiscan
causethestovetoemitfumesintotheroom.
· Ifthisapplianceisinstalledintoanexistingchimney,thechimneymustfirstbe
sweptandexaminedforsoundnessandsuitability,beforetheapplianceisinstalled
(seealsosectionheaded‘Chimney’).
ENGLISH RAISmanualforRaisGeo
8
Chimney
Thechimneyisthedrivingforcewhichmakesthestovefunction.Inorderforthestoveto
performsatisfactorilythechimneyheightmustbesufficienttoensurethecorrectdr aught
of14to18Pa,soastocleartheproductsofcombustionandpreventproblemsofsmoke
leakingintotheroomwhenthestoveislit.
Note:Achimneyheightofnotlessthan4.5metres,measuredverticallyfromtheoutletof
thestovetothetopofthechimney,shouldbesatisfactory.
AlternativelythecalculationproceduregiveninBS5854:1980maybeusedasthebasis
fordecidingwhetheraparticularchimneydesignwillprovidesufficientdraught.
Theoutletfromthechimneyshouldbeabovetheroofofthebuildinginaccordancewith
theprovisionsoftheBuildingRegulationsApprovedDocumentJ.
Iftheinstallationisintoanexistingchimney,thenitmustbesoundandhavenocracksor
otherfaultswhichmayallowfumesintothehouse.Olderproperties,especially,mayhave
chimneyfaultsorthecrosssectionmaybetoolargei.e.morethan230x230mm.
Remedialactionshouldbetakenifrequired,expertadviceshouldbesoughtwhere
required.
Ifthechimneyrequireslining,thenasuitablesolidfuelfluelinermustbe used,in
accordancewithBuildingRegulationsApprovedDocumentJ.
Anyexistingchimneymustbeclearofobstructionandshouldhavebeensweptclean
immediatelybeforetheinstallationofthestove.Ifthestoveisfittedinplaceofanopen
fire,thenthechimneyshouldbesweptonemonthafterinstallationtoclearanysootfalls
whichmayhaveoccurredduetothedifferenceincombustionbetweenthestoveandthe
openfire.
Ifthereisnoexistingchimneytheneitheraprefabricatedblockchimney,inaccordance
withBuildingRegulationsApprovedDocumentJoratwinwallinsulatedstainlesssteel
fluetoBS4543canbeused.Thesechimneysmustbefittedinaccordancewiththe
manufacturer’sinstructionsandtheBuildingRegulations.
Asinglewallmetalfluepipeissuitableforconnectingthestovetothechimneybutis
notsuitableforusingforthecompletechimney.Thechimneyand
connectingfluepipemusthaveaminimumdiameterof150mmandit’s
dimensionshouldbenotlessthanthesizeoftheoutletsocketofthestovewhichis
150mm.Anybendinthechimneyorconnectingfluepipeshouldnotexceed45°.90°
bendsshouldnotbeused.
Combustiblematerialshouldnotbelocatedwheretheheatdissipatingthroughthe
wallsoffireplacesorfluescouldigniteit.Thereforewheninstallingthestoveinthe
presenceofcombustiblematerialsdueaccountmustbetakenofthe
guidanceontheseparationofcombustiblematerialgiveninBuildingRegulationsAp
provedDocumentJandalsointhesestoveinstructions.
ENGLISH RAISmanualforRaisGeo
9
Ifitisfoundthatthereisexcessivedraughtinthechimneytheneitheran
adjustablefluedamperoralternativelyadraughtstabilisershouldbefitted.The
adjustablefluedampershouldnotcloseofftheflueentirely,butshouldinits
closedpositionleaveaminimumcontinuousopeningfreeareaofatleast20%
ofthetotalcrosssectionalareaoftheflueorfluepipe.
Adequateprovisione.g.easilyaccessiblesootdoorordoorsmustbeprovided
forsweepingthechimneyandconnectingfluepipe.
Youshouldalsofamiliariseyourselfwiththedraughtconditionsforchimneys
with2flues.
Forstrongdraughts,thechimneyorflueshouldbefittedwithadraught
stabiliser.Inwhichcase,itisimportanttoensurethatthereisafreeflowthrough
areaofminimum20cm
2
whentheregulatinggateisshut.Otherwise,thefuel
energymaynotbeusedoptimally.
If,atanytime,youareunsureabouttheconditionofthechimney,youshould
contactachimneysweep.
Rememberthataccesstothesootdoorshouldbekeptcl ear.
ENGLISH RAISmanualforRaisGeo
10
Installation
Itisprohibitedtocarryoutunauthorisedalterationstothestove.
Theremustbeplentyoffreshairintheroomwherethestoveisbeinginstalled,inorderto
ensurepropercombustion.Notethatanymechanicalexhaustventilatione.g.an
extractionhoodmayreducetheairsupply.Anyairgrillesmustbeplacedinsucha
manner,thattheairsupplyisnotblocked.
Thestoveisequippedwithfourconvectionairoutlets,whichmaybeconnectedwith
suitableairductstootherrooms.
BuildingRegulationsApprovedDocumentJgivesspecificguidanceontherequired
permanentventilationintotheroomforcombustionairofsolidfuelappliances.
Thefloorstructuremustbeabletocarrytheweightofthewoodburningstove,aswellas
theweightofachimney,ifnecessary.
WhenyouchoosewheretosetupyourRAISwoodburningstove,youshouldconsiderthe
heatdistributiontotheotherrooms.Thiswillenableyoutogetthebestuseoutofyour
stove.
Thestoveshouldbesetupatasafedistancefrominflammablematerials.
Seethemanufacturer'splateonthewoodburningstove.
ENGLISH RAISmanualforRaisGeo
11
ENGLISH RAISmanualforRaisGeo
12
1 Locatethestovewhereitistobeinstalled,itcannotbemovedoncethe
soapstonehasbeeninstalled.
A Therearflueconnectioncanbeinstalledafterthethirdrowofsoapstone
hasbeenpositioned(Geo161only).
B Fortopflueconnection,removethemarkedopeningwithaplasticor
rubberhammer.
C Installationuptotheceiling,theeasiestoptionistousetheRaissliding
fluesystemandadaptor.Thesteeltopplateshouldbepushedontothe
fluepipe.
2 Adjustthelegssothattheyarelevel.
Loosenthecounterscrew.
Adjusttheleg.
Tightenthecounterscrew.
3 Positionthesoapstoneasshownonthediagramandscrewthemtogether
withtheenclosedmountings.
Dependingonthechoiceofflueoutlet,youareleftwithonepieceof
soapstone,eithernumber7023or7033/7036.
4 Insertthefirebox.
A Ensurethatthefireboxiscentredwithinthestovebody,itmustNOT
touchthesoapstone.
B Ifyouareusingtherearflueoutletoption,ensurethattheexitholesare
aligned.
ENGLISH RAISmanualforRaisGeo
13
5 Withanexternalairconnection;
Mounttheairsupplyatthebottomofthestovewithaflexiblehoseanda
clamp.
6 Withoutanexternalairconnection;
Fittheventgrille(seestep5onpage16)
ENGLISH RAISmanualforRaisGeo
14
ENGLISH RAISmanualforRaisGeo
15
ENGLISH RAISmanualforRaisGeo
16
ENGLISH RAISmanualforRaisGeo
17
ENGLISH RAISmanualforRaisGeo
18
ENGLISH RAISmanualforRaisGeo
19
ENGLISH RAISmanualforRaisGeo
20
Installationdistanceincaseofcombustiblewall
Tofindoutwhetherthewallnexttowherethestoveisgoingtobeinstalledisflammable,
youshouldcontactyourbuildi ngcontractororthelocalbuildingauthorities.
Thehearthshouldbeabletoaccommodatetheweightofthestove.Thechimneymustbe
independentlysupportedbywallbracketsoraceilingsupportplate.Theweightofthestove
isindicatedinthebrochure.
Thestoveshouldalwaysbeinstalledonanoncombustiblehearthofasizeandconstruction
thatisinaccordancewiththeprovisi onsofthecurrentUKBuildingRegulati onsApproved
DocumentJ.
Ifthestoveistobeinstalledonawoodenfloor,itmustbecoveredwithanoncombustible
materialatleast12mmthick,inaccordancewithUKBuildingRegulationsApproved
DocumentJ,toadistanceof300mminfrontofthestoveand150mmtoeachside
measuringfromthedoorofthecombustionchamber.
Theclearancedistancestocombustiblematerialbeneath,surroundingoruponthehearth
andwallsadjacenttothehearthshouldcomplywiththeguidanceontheseparationof
combustiblematerialgiveninUKBuildingRegulationsApprovedDocumentJandalsoin
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38

RAIS Geo Instructions For Installation, Use And Maintenance Manual

Type
Instructions For Installation, Use And Maintenance Manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI