RAIS Q-TEE Instructions For Installation, Use And Maintenance Manual

Category
Stoves
Type
Instructions For Installation, Use And Maintenance Manual

RAIS Q-TEE is a high-performing wood-burning stove designed to provide efficient and clean heating for your home. Its convection technology ensures even heat distribution throughout the room, while the cool door handles offer added safety. With a nominal output of 4.7kW, it can effectively heat areas up to 90 square meters. Enjoy a warm and cozy ambiance while saving energy with this eco-friendly heating solution.

RAIS Q-TEE is a high-performing wood-burning stove designed to provide efficient and clean heating for your home. Its convection technology ensures even heat distribution throughout the room, while the cool door handles offer added safety. With a nominal output of 4.7kW, it can effectively heat areas up to 90 square meters. Enjoy a warm and cozy ambiance while saving energy with this eco-friendly heating solution.

ENGLISH RAISmanualforRaisQTee
1
INSTRUCTIONSFORINSTALLATION,
USEANDMAINTENANCE
RAISQTEE
IMPORTANTINFORMATION
Onfirstlightingthestove youmustbecarefulnottotouchthepainted
surfacesanditisMOSTIMPORTANTthatthedooriskeptslightly‘ajarin
orderforthedoorseal andsealanttocure.
Thiswillpreventthedoorsealstickingtothe paintedbodyandbecoming
damaged.
ENGLISH RAISmanualforRaisQTee
2
ENGLISH RAISmanualforRaisQTee
3
Revision:
Date :2011
INTRODUCTION ………………………………………………………….. 4
WARRANTY …………………………………………………….………….. 4
SPECIFICATIONS………………………………………………………….. 5
CONVECTION………………………………………………………………. 6
INSTALLATIONINSTRUCTIONS ………………………………….……… 7
CHIMNEY…………………………………………………….…………. 89
HEARTH………………………………………………………………… 9
INSTALLATION………………………………………………..……... 11
COMMISSIONINGANDHANDOVER……………………………… 11
MANUFACTURERSPLATE………………………………………………. 12
CHANGINGTHECHIMNEYCONNECTION…………………………….. 13
INSTALLATIONDISTANCETOCOMBUSTIBLEWALL…………....... 1416
INSTALLATIONDISTANCETONONCOMBUSTIBLEWALL……… 17
FORTHEINSTALLER……………………………………………………… 17
OPERATINGINSTRUCTIONS…………………………………………….. 22
FUEL…………………………………………………………………………... 22
DRYINGANDSTORAGE…………………………………………………… 23
REGULATIONOFCOMBUSTIONAIR…………………………………… 23
ROOMVENTILATIONANDSTOVES…………………………………….. 23
USINGTHEWOODBURNINGSTOVE…………………………………… 24
FIRSTUSAGE………………………………………………………………… 25
LIGHTINGANDFUELLING………………………………………………… 2627
CLEANINGANDCARE…………………………………………………….. 28
CLEANINGOFTHEFLUEWAYS………………………………………… 29
PROBLEMSOLVING……………………………………………………….. 30
ACCESSORIESANDSPAREPARTS……………………………………. 31
SPAREPARTDIAGRAM…….………..……………………………………. 3233
FITTINGTHEDIRECTAIRBOX…………………………………………… 3435
LOCKBLOCKFORSTEELDOORS………………………………………. 36
QUICKGUIDE…………………………………………………………………. 37
ENGLISH RAISmanualforRaisQTee
4
ARaiswoodburningstoveismorethanjustaheatsource:italsoshowsthatyou
careaboutdesignandqualityinyourhome.
Tomakethemostofyourwoodburningstoveitisimportantthatyoureadthemanual
thoroughlybeforeinstallingandusingit.
Inthecaseofwarrantycoverage,andforgeneralqueriesregardingyourwood
burningstove,itisimportantthatyouknowthestove’sproductionnumber.
Wethereforerecommendthatyounotedownthenumberinthetablebelow.
Theproductionnumberislocatedatthebackofthestoveatthebottom.
Warranty
YourRaiswoodburningstovecomeswitha5yearwarranty.
Thewarranty,however,doesnotcoverheatinsulatingmaterials,glassandseals.
TheseareavailabletoorderfromyourlocalRaisdealer/stockist.
Anyalterationsmadetothestovewillvoidthewarranty.
Introduction
ThankyouforpurchasingaRaiswoodburningstove.
TheseapplianceshavebeenapprovedbySCA/HETASas
intermittentoperatingappliancesforburningwoodl ogsonly.
TheseapplianceshavebeenapprovedforuseinSmokelessZones
ENGLISH RAISmanualforRaisQTee
5
QTee57
Nominaloutput(kW): 4.7
Min./Max.outp ut(kW): 45
Heatingarea(m
2
): Ca.3090
Size,widt h/depth/height(mm): 425/372/570
Combustionchamberwidth/depth/height(mm). 317/270/270
Recommendedamountofwoodwhenfuelling(kg)
(Basedon2  3logsofwoodapprox.25cm)
1.5
Min.uptake/Min.draught(Pascal): 12
Weight(kg): (SteelDoo r/GlassDoor) 79/81
Smokegasmassflow(g/s): 3.7
Smokegastemperature(°C): 283
Intermittentoperation: Fuellingshould
beundertaken
within3hours
Efficiency(%) 73
ParticlesafterNS3058/3059(g/kg) 3.6
DustmeasuredaccordingtoDin+(mg/Nm
3
) 20
QTee65
4.7
45
Ca.3090
425/372/650
317/270/270
1.5
12
82/84
73
3.6
20
3.7
283
Fuellingshould
beundertaken
within3hours
QTee85
4.7
45
Ca.3090
425/372/850
317/270/270
1.5
12
94/96
73
3.6
20
3.7
283
Fuellingshould
beundertaken
within3hours
Specifications
PleaseNote,thisappliancehasbeentestedbythemanufacturersandworksona3mstraightflue.
ENGLISH RAISmanualforRaisQTee
6
Convection
Raisstovesareconvectionstoves.Thismeansthatthestove’sbackandsidepanelsare
notoverheated.Convectionmeansthatthereisacirculationofair,whichensuresthat
theheatisdistributedmoreevenlythroughouttheentireroom.Thecoldairissuckedin
atthebaseofthestoveand upthroughtheconvectionchannel,whichrunsalongthe
stove’scombustionchamber.Theheatedaircomesoutatthetopofthestove,which
ensuresacirculationofwarmairthroughouttheroom.
Thestovesareequippedwithcooldoorhandles  aRaisspecialfeature which
meansyoucouldalmostdoawaywithgloves.Beaware,however,thatallexterior
surfacesbecomehotduringuse  sotakeextremecare.
ENGLISH RAISmanualforRaisQTee
7
PleasenotethatitisalegalrequirementunderEnglandandWalesBuilding
RegulationsthattheinstallationofthestoveiseithercarriedoutunderLocal
AuthorityBuildingControlapprovalorisinstalledbyaCompetentPerson
registeredwithaGovernmentapprovedCompetentPersonsScheme.HETASLtd
operatesuchaSchemeandalistingoftheirRegisteredCompetentPersonsca n
befoundontheirwebsiteatwww.hetas.co.uk.
COAlarms:
Buildingregulationsrequirethatwheneveraneworreplacementfixedsolidfuel
orwood/biomassapplianceisinstalledinadwellingacarbonmonoxidealarm
mustbefittedinthesameroomastheappliance.Furtherguidanceonthe
installationofthecarbonmonoxidealarmisavailableinBSEN50292:2002and
fromthealarmmanufacturer’sinstructions.
Provisionofanalarmmustnotbeconsideredasubstituteforeitherinstallingthe
appliancecorrectlyorensuringregularservicingandmaintenanceoftheappli
anceandchimneysystem.
HEALTHANDSAFETYPRECAUTIONS
Specialcaremustbetakenwheninstallingthestovesuchthattherequirementsofthe
HealthandSafetyatWorkActaremet.
Handling
Adequatefacilitiesmustbeavailableforloading,unloadingandsitehandling.
FireCement
Sometypesoffirecementarecausticandshould notbeallowedtocomeintocontact
withtheskin.Incaseofcontactwashimmediatelywithplentyofwater.
Asbestos
Thisstovecontainsnoasbestos.Ifthereisapossibilityofdisturbinganyasbestosin
thecourseofinstallationthenpleaseseek specialistguidanceanduseappropriate
protectiveequipment.
MetalParts
Wheninstallingorservicingthisstovecareshouldbetakentoavoidthepossibilityof
personalinjury.
Theseinstructions togetherwiththoseintheinstructionbookletcover
thebasicprinciplestoensurethesatisfactoryinstallationofthestove,
althoughdetailmayneedslightmodificationtosuitparticularlocalsite
conditions.
InallcasestheinstallationmustcomplywithcurrentBuildingRegulations,
LocalAuthorityByelawsandotherspecificationsorregulationsastheyaffect
theinstallationofthestove.
ItshouldbenotedthattheBuildingRegulationsrequirementsmaybemetby
adoptingtherelevantrecommendationsgiveninBritishStandardsBS8303,
BSEN152871:2007asanalternativemeanstoachieveanequivalentlevelof
performancetothatobtainedfollowingtheguidancegiveninApproved
DocumentJ.
ENGLISH RAISmanualforRaisQTee
8
STOVEPERFORMANCE
IntheUKthestovehasbeenapprovedbyHETASLtdasanintermittentoperating
applianceforburningwoodlogsonl y.
PREPARATORYWORKANDSAFETYCHECKS
IMPORTANTWARNING
Thisstovemustnotbeinstalledintoachimneythatservesanyotherheatingappliance.
Theremustnotbeanextractorfanfittedinthesameroomasthestoveasthiscancause
thestovetoemitfumesintotheroom.
Chimney
Inorderforthestovetoperformsatisfactorilythechimneyheightmustbesufficientto
ensureanadequatedraughtofapproximately15Pasoastocleartheproductsof
combustionandpreventsmokeproblemsintotheroom.
NOTE:Achimneyheightofnotlessthan4.5metresmeasuredverticallyfromtheoutletof
thestovetothetopofthechimneyshouldbesatisfactory.Alternativelythecalculation
proceduregiveninEN133841maybeusedasthebasisfordecidingwhetheraparticular
chimneydesignwillprovidesufficientdraught.
PleaseNote,thisappliancehasbeentestedbythemanufacturersandworksona3m
straightflue.
Theoutletfromthechimneyshouldbeabovetheroofofthebuildinginaccordancewith
theprovisionsofBuildingRegulationsApprovedDocumentJ.
Ifinstallationisintoanexistingchimneythenitmustbesoundandhavenocracksorother
faultswhichmightallowfumesintothehouse.Olderproperties,especially,mayhave
chimneyfaultsorthecrosssectionmaybetoolargei.e.morethan230mmx230mm.
Remedialactionshouldbetaken,ifrequired,seekingexpertadvice,ifnecessary.Ifitis
foundnecessarytolinethechimneythenafluelinersuitableforsolidfuelmustbeusedin
accordancewithBuildingRegulationsApprovedDocumentJ.
Anyexistingchimneymustbeclearofobstructionandhavebeenswe ptcleanimmediately
beforeinstallationofthestove.Ifthestoveisfittedinplaceofanopenfirethenthe
chimneyshouldbesweptonemonthafterinstallationtoclearanysootfallswhichmay
haveoccurredduetothedifferenceincombustionbetweenthestoveandtheopenfire.
Ifthereisnoexistingchimneytheneitheraprefabricatedblockchimneyinaccordance
withBuildingRegulationsApprovedDocumentJoratwi nwall edinsulatedstainlesssteel
fluetoBS4543canbeused.Thesechimneysmustbefittedinaccordancewiththe
manufacturer’sinstructionsandBuildingRegulations.
ENGLISH RAISmanualforRaisQTee
9
Asinglewallmetalfluepipeissuitableforconnectingthestovetothec himneybutisnot
suitableforusingforthecompletechimney.Thechimneyandconnectingfluepipemust
haveaminimumdiameterof125mmanditsdimensionshouldbenotlessthanthesizeof
theoutletsocketofthestove.
Anybendinthechimneyorconnectingfluepipeshouldnotexceed45°.90°bendsshould
notbeused.
Combustiblematerialshouldnotbelocatedwheretheheatdissipatingthroughthewallsof
fireplacesorfluescouldigniteit.Thereforewheninstallingthestoveinthepresenceof
combustiblematerialsdueaccountmustbetakenoftheguidanceontheseparationof
combustiblematerialgiveninBuildingRegulationsApprovedDocumentJandalsoin
thesestoveinstructions.
Ifitisfoundthatthereisexcessivedraughti nthechimneythenadraughtstabilisershould
befitted.Fittingofadraughtstabiliserwillaffecttherequirementforthepermanentair
supplyintotheroominwhichthestoveisfittedinaccordancewithApprovedDocumentJ
(seealsocombustionairsupply).
Adequateprovisione.g.easilyaccessiblesootdoorordoorsmustbeprovidedfor
sweepingthechimneyandconnectingfluepipewhereitisnotintendedforthechimneyto
besweptthroughtheappliance,alsotopermitvisualchecksontheintegrityoftheflue
whentheapplianceisserviced.
Hearth
Thehearthshouldbeabletoaccommodatetheweightofthestoveanditschimneyifthe
chimneyisnotindependentlysupported.Theweightofthestoveisindicatedinthe
brochure.
Thestoveshouldalwaysbeinstalledonanoncombustiblehearthofasi zeand
constructionthatisinaccordancewiththeprovisionsofthecurrentBuildingRegulations
ApprovedDocumentJ.
Theclearancedistancestocombustiblematerialbeneath,surroundingoruponthehearth
andwallsadjacenttothehearthshouldcomplywiththeguidanceontheseparationof
combustiblematerialgiveninBuildingRegulationsApprovedDocumentJandalsoin
thesestoveinstructions.
If the stove is to be installed on a combustible floor surface, it must be covered with a
noncombustible material at l east 12mm thick, in accordance with Building Regulations
ApprovedDocumentJ,toadistanceof30cminfrontofthestoveand15cmtoeachside
measuringfromthedoorofthecombustionchamber.
ENGLISH RAISmanualforRaisQTee
10
Combustionairsupply
Inorderforthestovetoperformefficientlyandsafelythereshouldbeanadequateair
supplyintotheroominwhichthestoveisinstalledtoprovidecombustionair.Thisis
particularlynecessaryiftheroomisdoubleglazedorafluedraughtstabiliserisoperat
inginthesameroomastheappliance.Itmaybenecessarytoincrease theairventsize
inpropertywithlowairpermeability(<5.0m
3
/(h.m
2
).
Theprovisionofairsupplytothestovemustbei naccordancewithcurrentBuilding
RegulationsApprovedDocumentJ.Anopeni ngwindowisnotappropriateforthis
purpose.
IMPORTANTNOTE:Ifapplicableandtheapplianceisbeingfittedwithinanexisting
fireplacerecess,specialistadviceshouldbesoughtbeforefittingany permanent
ventilationwithinthisarea.
Connectiontochimney
Stovesmayhaveachoiceofeitherarearortopfl uegasconnectorthatallows
connectiontoeitheramasonrychimneyoraprefabricatedfactorymadeinsulatedmetal
chimneyinaccordancewiththeirinstructions.Insomecasesitmaybenecessarytofit
anadaptortoincreasethediameterofthefluetotheminimumrequired150mmsection
ofthechimneyorliner.
ElectricalServices
Theinstallationofanyelectricalservicesduringtheinstallationofthisappliancemustbe
carriedoutbyaregisteredcompetentelectricianandinaccordancewiththe
requirementsofthelatestissueofBS7671
CarbonMonoxideAlar m
AcarbonmonoxidealarmcomplyingwithBSEN50292mustbefittedinthesameroom
astheappliance.Itshouldbepositionedontheceilingatleast300mmfromanywallor,
ifitislocatedonawall,ashighupaspossible(aboveanydoorsandwindows)butnot
within150mmoftheceiling.Thealarmshouldalsobebetween1mand3mhorizontally
fromtheappliance.
ENGLISH RAISmanualforRaisQTee
11
Installation
Itisprohibitedtocarryoutunauthorisedalterationstothestove.
Theremustbeplentyoffreshairintheroomwherethestoveisbeinginstalled,i n
ordertoensurepropercombustion.Notethatanymechanicalexhaustventilation
e.g.anextractionhoodmayreducethea irsupply.Anyairgrillesmustbeplaced
insuchamanner,thattheairsupplyisnotblocked.
BuildingRegulationsApprovedDocumentJgivesspecificguidanceontherequired
permanentventilationintotheroomforcombustionai rofsolidfuelappliances.
Thefloorstructuremustbeabletocarrytheweightofthewoodburningstove,as
wellastheweightofachimney,ifnecessary.
WhenyouchoosewheretosetupyourRAISwoodburningstove,yo ushould
considertheheatdistributiontotheotherrooms.Thiswillenableyoutogetthebest
useoutofyourstove.
Thestoveshouldbesetupatasafedistancefrominflammablematerials.
Seethemanufacturer'splateonthewoodburningstove.
Commissioningandhandover
Ensureloosepartsarefittedinaccordancewitht heinstructionsgiveninthe
instructionbooklet.
Oncompletionoftheinstallationallowasuitableperiodoftimeforanyfirecement
andmortartodryout,whenasmallfiremaybelitandcheckedtoensurethe
smokeandfumesaretakenfromthestoveupt hechimneyandemittedsafelyto
atmosphere.Donotrunatfulloutputforatleast24hours.
Oncompletionoftheinstallationandcommissioningensurethattheoperating
instructionsforthestoveareleftwiththecustomer.Ens uretoadvisethecustomer
onthecorrectuseoftheappliancewithth efuelslikelytobeusedonthestoveand
warnthemtouseonlytherecommendedfuelsforthestove.
Advisetheuserwhattodoshouldsmokeorfumesbeemittedfromthestove.The
customershouldbewarnedtouseafireguardtoBS8423:2002(ReplacesBS
6539)inthepresenceofchildren,agedand/orinfirmpersons.
ENGLISH RAISmanualforRaisQTee
12
ENGLISH RAISmanualforRaisQTee
13
Removethecasingknockout.
Removetheprotectivecover/sealandplaceoverthe
holeinthetopmakesurethatthesealispositioned
properly.TightentheassemblyusingthethreeM6nuts.
Theflueoutletspigot,whichcanbefoundinthestoveina
bag,andtheholderfortheupperfluediverterare
assembledwith3M6x20nutsandbolts.
Theupperfluediverter,baffleplateandtopplateare
assembledinreverseorder.
Changingthechimneyconnection
ENGLISH RAISmanualforRaisQTee
14
Installationdistancetocombustiblewall
Tofindoutwhetherthewallnexttowherethestoveisgoingtobeinstalledisflammable,
youshouldcontactyourbuildingcontractororthelocalbuildingauthorities.
Thehearthshouldbeabletoaccommodatetheweightofthestove.Thechimneymustbe
independentlysupportedbywallbracketsoraceilingsupportplate.Thewei ghtofthestove
isindicatedinthebrochure.
Thestoveshouldalwaysbeinstalledonanoncombustiblehearthofasi zeandconstruction
thatisinaccordancewiththeprovisionsofthecurrentUKBuildingRegulationsApproved
DocumentJ.
Ifthestoveistobeinstalledonawoodenfloor,itmustbecoveredwithanoncombustible
materialatleast12mmthick,inaccordancewithUKBuildingRegulationsApproved
DocumentJ,toadistanceof300mminfrontoft hestoveand150mmtoeachside
measuringfromthedoorofthecombustionchamber.
Theclearancedistancestocombustiblematerialbeneath,surroundingoruponthehearth
andwallsadjacenttothehearthshouldcomplywiththeguidanceontheseparationof
combustiblematerialgiveninUKBuildingRegulationsApprovedDocumentJandalsoin
thesestoveinstructions.
Informtheuserthattheappliancehasbeencommissi onedandreadytouseandgive
instructiononthesafeoperationofthestove.
TheseInstructionsmustbeleftwiththeuserandt heusershouldbeinstructedtokeepthem
inasafeplace.
ENGLISH RAISmanualforRaisQTee
15
Normalsetupcornersetting
Uninsulatedflue Insulatedflue
A. Distancetofurniture 650mm 650mm
Distancetoflammablematerials:
B. infront(floor) 300mm 300mm
C. totheside(floor) 150mm 150mm
D. totherear(floor) 350mm 275mm
E. tothesideofthewall 275mm 225mm
ENGLISH RAISmanualforRaisQTee
16
Cornersetting45°fixedsocket
Uninsulatedflue Insulatedflue
A. Distancetofurniture 650mm 650mm
Distancetoflammablematerials:
B. infront(floor) 300mm 300mm
C. totheside(floor) 150mm 150mm
D. totherear(wall) 225mm 175mm
E. tothesideofthewall 275mm 225mm
ENGLISH RAISmanualforRaisQTee
17
Installationdistanceincaseofnoncombustiblewall
Werecommendamini mumdistancetononcombustiblematerialof50mm(F)for
cleaningconsiderations.
Usinguninsulatedfluepipe,theminimumdistancetoacombustiblewallmustbe
450mmor225mmifthewallisheatshielded(seeSectionJoftheBuildingRegu
lations)fromthefluepipe.
FortheInstaller
Finallybeforefiringthestoveforthefirsttimeacheckshouldbemadetoensurethat
theassemblyandstoveinstallationhasbeensatisfactoryandthattherearenoleaksin
anysealsintheapplianceandapplianceconnectionstot hechimney.
Ensurethattheapplianceandchimneyfluearefunctioningcorrectlybeforefinally
handingovertotheuser.Ifnecessaryreadthelaterpartsofthismanualforguidance
oncarerequiredwhenfirstlighting.
Informtheuserthattheappliancehasbeencommissi onedandreadytouseandgive
instructiononthesafeoperationofthestove.
TheseInstructionsmustbeleftwiththeuserandt heusershouldbeinstructedtokeep
theminasafeplace.
ENGLISH RAISmanualforRaisQTee
18
WARNINGNOTE
Properlyinstalled,operatedandmaintainedthi sstovewillnotemitfumesintothe
dwelling.Occasionalfumesfromdeashingandrefuellingmayoccur.However,
persistentfumeemissionispotentiallydangerousandmustnotbetolerated.Inthe
eventoffumeemissionfromtheappliance,thenthefollowingimmediateaction
shouldbetaken:
(a) Opendoorsandwindowstoventilateroomandthenleavethepremises
(b) Letthefiregoout
(c) Whensafetodoso,checkforflueorchimneyblockageandcleanifrequi red
(d) Donotattempttorelightthefireuntilthecauseofthefumeemissionhasbeen
identifiedandcorrected.Ifnecessaryseekexpertadvice.
Themostcommoncauseoffumeemissionisfluewayorchimneyblockage.For
yourownsafetythesemustbekeptcleanatall times.
IMPORTANTNOTES
General
Beforelightingthestovecheckwiththeinstallerthattheinstallationworkandcom
missioningchecksdescribedintheinstallationinstructionshavebeencarriedout
correctlyandthatthechimneyhasbeensweptclean,issounda ndfreefromany
obstructions.Aspartofthestoves’commissioningandhandovertheinstaller
shouldhaveshownyouhowtooperatethestovecorrectly.
COAlarm
YourinstallershouldhavefittedaCOalarminthesameroomastheappliance.If
thealarmsoundsunexpectedly,followtheinstructionsgivenunder“WarningNote”
above.
Useoffireguard
Whenusingthestoveinsituationswherechildren,agedand/orinfirmpersonsare
presentafireguardmustbeusedtopreventaccidentalcontactwiththestove.
ThefireguardshouldbemanufacturedinaccordancewithBS8423:2002
(ReplacesBS6539).
IfthefireisleftunattendedasparkguardtoBS3248,specificati onforspark
guardsforusewithsolidfuelappliancesshouldbeused.
Chimneycleaning
Thechimneyshouldbesweptatleasttwiceayear.Itisimportantthatthefluecon
nectionandchimneyaresweptpriortolightingupafteraprolongedshutdownpe
riod.
ENGLISH RAISmanualforRaisQTee
19
Ifthestoveisfittedinplaceofanopenfirethenthechimneywillrequiresweepi ng
afteramonthofcontinuousoperation.Thisi saprecautiontoensurethatany
“softer”depositsleftfromtheopenfireusagehavenotbeenloosenedbythehigher
fluetemperaturesgeneratedbytheclosedstove.
Insituationswhereitisnotpossibletosweepthroughthestovetheinstallerwill
haveprovidedalternativemeans,suchasasootdoor.Aftersweepingthechim
neythestoveflueoutletandthefluepipeconnectingthestovetothechimney
mustbecleanedwithafluebrush.
SpecialNotesforuseinaSmokeControlArea(RaisQTee):
Refuellingontoalowfirebed
Ifthereisinsufficientburningmaterialinthefirebedtolightanewfuelcharge,ex
cessivesmokeemissioncanoccur.Refuellingmustbecarriedoutontoasufficient
quantityofglowingembersandashthatthenewfuelchargewilligniteinareason
ableperiod.Iftherearetoofewembersinthefirebed,addsuitableki ndlingtopre
ventexcessivesmoke
Fueloverloading
Themaximumamountoffuelspecifiedinthismanualshouldnotbeexceeded,
overloadingcancauseexcesssmoke.
Operationwithdoorleftopen
Operationwiththedooropencancauseexcesssmoke.Theappliancemustnot
beoperatedwiththeappliancedoorleftopenexceptasdirectedintheinstruc
tions.
Dampersleftopen
Operationwiththeaircontrolsordampersopenca ncauseexcesssmoke.Theap
pliancemustnotbeoperatedwithaircontrolsordampersdoorleftopenexceptas
directedintheinstructions.
PeriodsofProlongedNonUse
Ifthestoveistobeleftunusedforaprolongedperiodoftimethenitshouldbe
givenathoroughcleantoremoveashand unburnedfuelresidues.Toenablea
goodflowofairthroughtheappliancetoreducecondensationandsubsequent
damage,leavetheaircontrolsfullyopen.
Extractorfan
Theremustnotbeanextractorfanfittedinthesameroomasthestoveasthiscan
causethestovetoemitsmokeandfumesintot heroom.
Aerosolsprays
Donotuseanaerosolsprayonornearthestovewhenitisalight.
Useofoperatingtools
Alwaysusetheoperatingtoolsprovidedwhenhandlingpartslikelytobehotwhen
thestoveisinuse.
ENGLISH RAISmanualforRaisQTee
20
ChimneyFires
Ifthechimneyisthoroughlyandregularlyswept,chimneyfiresshouldnotoccur.
However,ifachimneyfiredoesoccurturnoffthestoveimmediatelyandisolate
themainselectricitysupply(ifapplicable),andtightlyclosethedoorsofthestove.
Thisshouldcausethechimneyfiretogoout.Ifthechimneyfiredoesnotgoout
whentheaboveactionistakenthenthefirebrigadeshouldbecalledimmediately.
Donotrelightthestoveuntilthechimneyandfluewayshavebeencleanedandex
aminedbyaprofessional.
Permanentairvent
Thestoverequiresapermanentandadeq uateairsupplyinorderforittooperate
safelyandefficiently.
InaccordancewithcurrentBuildingRegulationstheinstallermayhavefittedaper
manentairsupplyventintotheroominwhichthestoveisinstalledtoprovidecom
bustionair.Thisairventshouldnotunderanycircumstancesbeshutofforsealed.
USEROPERATINGINSTRUCTIONSWOOD
Pleasereadtheimportantnoticesgivenabovebeforereferringtothemaininstruc
tionbookfordetailedoperatinginstructions.
HETASLtdApproval
HETASapprovalmaybelimitedtospecificfueltypesasdetailedinthemainin
structionmanuals.Approvaldoesnotcoverthe useofotherfuelseitheraloneor
mixedwiththerecommendedfuel,nordoesitcoverinstructionsfortheuseof
otherfuels.
Recommendedfuels
Stovesmaybedesignedtoburndryseasonedwoodlogsand/orsolidmineralfuel
asindicatedinthemainstovemanuals.
Dooroperation
Thedoorhandlemaybecomehotduringoperation,usethetooltoopenandclosethe
doors,ifappropriate.
Lightingoffire
Placesomefirelightersorpaperanddrykindlingwoodo nthegrateandcoverwith
asmallamountoffuel.Setaircontrolstomaximumandsetlighttofirelightersor
paper.Closethedoorsandallowfiretoburnuntilfueliswellalightthenloadwith
morefuelandadjustaircontrolstotherequiredlevelofheatoutput.
Beforerelightingthefirecleanthefirebedofashandclinkerandemptythe
ashpan.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42

RAIS Q-TEE Instructions For Installation, Use And Maintenance Manual

Category
Stoves
Type
Instructions For Installation, Use And Maintenance Manual

RAIS Q-TEE is a high-performing wood-burning stove designed to provide efficient and clean heating for your home. Its convection technology ensures even heat distribution throughout the room, while the cool door handles offer added safety. With a nominal output of 4.7kW, it can effectively heat areas up to 90 square meters. Enjoy a warm and cozy ambiance while saving energy with this eco-friendly heating solution.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI