RAIS 800 is a wood-burning stove offering efficient and clean heating with a nominal output of 5kW, heating an area of approximately 100 square meters. It features a convection design for even heat distribution, boasts cool-touch door handles for safety, and provides intermittent operation with fuelings within 3 hours. Installation requirements include a suitable chimney with a minimum height of 4.5 meters and a diameter of at least 150mm, while maintaining a minimum distance to combustible walls.

RAIS 800 is a wood-burning stove offering efficient and clean heating with a nominal output of 5kW, heating an area of approximately 100 square meters. It features a convection design for even heat distribution, boasts cool-touch door handles for safety, and provides intermittent operation with fuelings within 3 hours. Installation requirements include a suitable chimney with a minimum height of 4.5 meters and a diameter of at least 150mm, while maintaining a minimum distance to combustible walls.

ENGLISH RAISmanualforRais800
1
INSTRUCTIONSFORINSTALLATION,
USEANDMAINTENANCE
RAIS800
IMPORTANTINFORMATION
Onfirstlightingthestove youmustbecarefulnottotouchthepainted
surfacesanditisMOSTIMPORTANTthatthedooriskeptslightly‘ajarin
orderforthedoorseal andsealanttocure.
Thiswillpreventthedoorsealstickingtothe paintedbodyandbecoming
damaged.
ENGLISH RAISmanualforRais800
2
ENGLISH RAISmanualforRais800
3
INTRODUCTION ………………………………………………………….. 4
WARRANTY …………………………………………………….………….. 4
SPECIFICATIONS………………………………………………………….. 5
CONVECTION………………………………………………………………. 6
INSTALLATIONINSTRUCTIONS ………………………………….……… 7
CHIMNEY………………………………………………………….…………. 89
INSTALLATION……………………………………………………………... 10
INSTALLATIONOFSTOVE………………………………………………. 11
INSTALLATIONDISTANCETOCOMBUSTIBLEWALL……….…….. 1213
INSTALLATIONDISTANCETONONCOMBUSTIBLEWALL…..…… 1415
FORTHEINSTALLER……………………………………………………… 17
OPERATINGINSTRUCTIONS…………………………………………….. 18
FUEL…………………………………………………………………………... 18
DRYINGANDSTORAGE…………………………………………………… 19
REGULATIONOFCOMBUSTIONAIR…………………………………… 19
USINGTHEWOODBURNINGSTOVE…………………………………… 20
FIRSTUSAGE………………………………………………………………… 21
LIGHTINGANDFUELLING………………………………………………… 2223
CLEANINGANDCARE…………………………………………………….. 24
CLEANINGOFTHEFLUEWAYS………………………………………… 25
PROBLEMSOLVING……………………………………………………….. 26
ACCESSORIESANDSPAREPARTS……………………………………. 27
SPAREPARTDIAGRAM…….………..……………………………………. 2829
RAIS800
Revision:
Date :2011
ENGLISH RAISmanualforRais800
4
ARaiswoodburningstoveismorethanjustaheatsource:italsoshowsthatyoucare
aboutdesignandqualityinyourhome.
Tomakethemostofyourwoodburningstoveitisimportantthatyoureadthemanual
thoroughlybeforeinstallingandusingit.
Inthecaseofwarrantycoverage,andforgeneralqueriesregardingyourwoodburn
ingstove,itisimportantthatyouknowthestove’sproductionnumber.
Wethereforerecommendthatyounotedownthenumberinthetablebelow.
Theproductionnumberislocatedinthetopoftheconvectionbox.
Warranty
YourRaiswoodburningstovecomeswitha5yearwarranty.
Thewarranty,however,doesnotcoverheatinsulatingmaterials,glassandseals.
TheseareavailabletoorderfromyourlocalRaisdealer/stockist.
Anyalterationsmadetothestovewillvoidthewarranty.
Introduction
ThankyouforpurchasingaRaiswoodburningstove.
TheseapplianceshavebeenapprovedbyHETASas
intermittentoperatingappliancesforburningwoodl ogsonly.
ENGLISH RAISmanualforRais800
5
Rais800
Nominaloutput(kW): 5
Min./Max.outp ut(kW): 4.75.5
Heatingarea(m
2
): Ca.100
Size,widt h/depth/height(mm): 541/490/1227
Combustionchamberwidth/depth/height(mm). 370/380/411
Recommendedamountofwoodwhenfuelling(kg)
(Basedon2  3logsofwoodapprox.25cm)
1.5
Min.uptake/Min.draught(Pascal): 12
Weight(kg):  130
Efficiency(%): 77
ParticlesafterNS3058/3059(g/kg): 2.7
DustmeasuredaccordingtoDin+(mg/Nm
3
):
Smokegasmassflow(g/s): 6.4
Smokegastemperature(°C): 297
Intermittentoperation: Fuellingshouldbe
undertaken
within3hours
PleaseNote,thisappliancehasbeentestedbythemanufacturersandworksona
3mstraightflue.
ENGLISH RAISmanualforRais800
6
Thestovesareequippedwithcooldoorhandles  aRaisspecialfeature whichmeans
youcouldalmostdoawaywithgloves.Beaware,however,thatallexteriorsurfaces
becomehotduringuse  sotakeextremecare.
Convection
Raisstovesareconvectionstoves.Thismeansthatthestove’sbackandsidepanelsare
notoverheated.Convectionmeansthatthereisacirculationofair,whichensuresthat
theheatisdistributedmoreevenlythroughouttheentireroom.Thecoldairissuckedinat
thebaseofthestoveandupthroughtheconvectionchannel,whichrunsalongthe
stove’scombustionchamber.Theheatedaircomesoutatthetopofthestove,which
ensuresacirculationofwarmairthroughouttheroom.
ENGLISH RAISmanualforRais800
7
InstallationInstructions
Thefollowingpagesgiveinstructionsforthesafeandproperinstallationofthisheating
applianceintheUK.Theseinstructionscoverthebasicprincipl esofinstallation,
althoughsomedetailsmayneedslightmodificationtosuitparticularlocalsiteconditions.
InallcasestheinstallationmustcomplywithcurrentUKBuildingRegulations,Local
AuthorityByelawsandotherspecificationsorregulationsastheyaffecttheinstallationof
thestove.
PleasenotethatitisalegalrequirementunderEnglandandWalesBuildingRegulations
thattheinstallationofthestoveiseithercarriedoutunderlocalAut horityBuilding
ControlapprovalorisinstalledbyaCompetentPersonregi steredwithaGovernment
approvedCompetentPersonsScheme.HETASoperatesuchaschemeandalistingof
theirregisteredCompetentPersonscanbefoundontheirwebsiteatwww.hetas.co.uk.
ItshouldbenotedthatthecurrentBuildingRegulationsrequirementsaregivenin
ApprovedDocumentJ.Theserequirementsmayalsobemetbyadoptingtherelevant
recommendationsgiveninBritishStandardsBS8303,BS6461andBS7566.
WARNING.HealthandSafetyAdviceNotice.
TheinstallationofthisheatingapplianceisgovernedbytheHealthandSafetyatWork
Act1974.itistheresponsibilityoftheinstallertoensurethatallrequirementsofthisAct
aremetduringtheinstallationworks.Attentionisdraw ninparticulartothefollowing:
Handling: Theapplianceisaheavyitemandadequa tefacilitiesmustbeavailable
forloading,unloadingandsitehandling.
FireCement: Sometypesoffirecementarecausti candshouldnotbeallowedtocome
intocontactwiththeskin.Protectiveglovesshouldbewornwhen
handlingfirecement.Incaseofcontactwiththeskin,washimmediately
withplentyofwater.
Asbestos: Thisstovecontainsnoasbestos.Ifthereisapossibilityofdisturbingany
asbestosinthecourseoftheinstallation,thenpleaseseekspeciali st
guidanceanduseappropriateprotectiveequipment.
MetalParts: Wheninstallingorservicingthisstovecareshouldbetakentoavoidthe
possibilityofpersonalinjury.
ImportantWarning  PreparatoryWorkandsafetyChecks:
· Thisstovemustnotbeinstalledintoachimneywhichservesanyotherheating
appliance.
· Theremustnotbeanextractorfanfittedinthesameroomasthestove,asthiscan
causethestovetoemitfumesintotheroom.
· Ifthisapplianceisinstalledintoanexistingchimney,thechimneymustfirstbe
sweptandexaminedforsoundnessands uitabili ty,beforetheapplianceisinstalled
(seealsosectionheaded‘Chimney’).
ENGLISH RAISmanualforRais800
8
Chimney
Thechimneyisthedrivingforcewhichmakesthestovefunction.Inorderforthestoveto
performsatisfactorilythechimneyheightmustbesufficienttoensurethecorrectdraught
of14to18Pa,soastocleartheproductsofcombustionandpreventproblemsofsmoke
leakingintotheroomwhenthestoveislit.
Note:Achimneyheightofnotlessthan4.5metres,measuredverticallyfromtheoutletof
thestovetothetopofthechimney,shouldbesatisfactory.
AlternativelythecalculationproceduregiveninBS5854:1980maybeusedasthebasis
fordecidingwhetheraparticularchimneydesignwillprovidesufficientdraught.
PleaseNote,thisappliancehasbeentestedbythemanufacturersandworksona3m
straightflue.
Theoutletfromthechimneyshouldbeabovetheroofofthebuildinginaccordancewith
theprovisionsoftheBuildingRegulationsApprovedDocumentJ.
Iftheinstallationisintoanexistingchimney,thenitmustbesoundandhavenocra cksor
otherfaultswhichmayallowfumesintothehouse.Olderproperties,especially,mayhave
chimneyfaultsorthecrosssectionmaybetoolargei.e.morethan230x230mm.
Remedialactionshouldbetakenifrequired,expertadviceshouldbeso ughtwhere
required.
Ifthechimneyrequireslining,thenasuitablesolidfuelfluelinermustbeused,in
accordancewithBuildingRegulationsApprovedDocumentJ.
Anyexistingchimneymustbeclearofobstructionandshouldhavebe ensweptclean
immediatelybeforetheinstallationofthestove.Ifthestoveisfittedinplaceofanopen
fire,thenthechimneyshouldbesweptonemonthafterinstallationtoclearanysootfalls
whichmayhaveoccurredduetothedifferenceincombustionbetweenthestoveandthe
openfire.
Ifthereisnoexistingchimneytheneitheraprefabricatedblockchimney,inaccordance
withBuildingRegulationsApprovedDocumentJoratwi nwall insulatedstainlesssteel
fluetoBS4543canbeused.Thesechimneysmustbefittedinaccordancewiththe
manufacturer’sinstructionsandtheBuildingRegulations.
Asinglewallmetalfluepipeissuitableforconnectingthestovetothec himneybutis
notsuitableforusingforthecompletechimney.Thechimneyand
connectingfluepipemusthaveaminimumdiameterof150mmandit’s
dimensionshouldbenotlessthanthesizeoftheoutletsocketofthestovewhichis
150mm.Anybendinthechimneyorconnectingfluepipeshouldnotexceed45°.90°
bendsshouldnotbeused.
Combustiblematerialshouldnotbelocatedwheretheheatdissipatingthroughthe
wallsoffireplacesorfluescouldigniteit.Thereforewheninstallingthestoveinthe
presenceofcombustiblematerialsdueaccountmustbetakenofthe
guidanceontheseparationofcombustibl ematerialgiveninBuildingRegulationsAp
provedDocumentJandalsointhesestoveinstructions.
ENGLISH RAISmanualforRais800
9
Ifitisfoundthatthereisexcessivedraughti nthechimneytheneitheran
adjustablefluedamperoralternativelyadraughtstabilisershouldbefitted.The
adjustablefluedampershouldnotcloseofftheflueentirely,butshouldinits
closedpositionleaveaminimumcontinuousopeningfreeareaofatleast20%
ofthetotalcrosssectionalareaoftheflue orfluepipe.
Adequateprovisione.g.easilyaccessiblesootdoorordoorsmustbeprovided
forsweepingthechimneyandconnectingfluepipe.
Youshouldalsofamiliariseyourselfwiththedraughtconditionsforchimneys
with2flues.
Forstrongdraughts,thechimneyorflueshouldbefittedwithadraught
stabiliser.Inwhichcase,itisimportanttoensurethatt hereisafreeflowthrough
areaofminimum20cm
2
whentheregulatinggateisshut.Otherwise,thefuel
energymaynotbeusedoptimally.
If,atanytime,youareunsureabouttheconditionofthechimney,youshould
contactachimneysweep.
Rememberthataccesstothesootdoorshouldbekeptclear.
ENGLISH RAISmanualforRais800
10
Installation
Itisprohibitedtocarryoutunauthorisedalterationstothestove.
Theremustbeplentyoffreshairintheroomwherethestoveisbeinginstalled,i norderto
ensurepropercombustion.Notethatanymechanicalexhaustventilatione.g.an
extractionhoodmayreducetheairsupply.Anyai rgrillesmustbeplacedinsucha
manner,thattheairsupplyisnotblocked.
Thestoveisequippedwithfourconvectionairo utlets,whichmaybeconnectedwith
suitableairductstootherrooms.
BuildingRegulationsApprovedDocumentJgivesspecificguidanceontherequired
permanentventilationintotheroomforcombustionai rofsolidfuelappliances.
Thefloorstructuremustbeabletocarrytheweightofthewoodburningstove,aswellas
theweightofachimney,ifnecessary.
WhenyouchoosewheretosetupyourRAISwoodburningstove,yo ushouldconsiderthe
heatdistributiontotheotherrooms.Thiswillenableyoutogetthebestuseoutofy our
stove.
Thestoveshouldbesetupatasafedistancefrominflammablematerials.
Seethemanufacturer'splateonthewoodburningstove.
ENGLISH RAISmanualforRais800
11
Installationofstove:
NOTE! Adecisionmustbemadeconcerningthepositioningoftheinletsandoutlets
oftheconvectionsystem.Discolourationofthewallabovethedoorsandthe
convectionairoutletsmayoccurduetoconvectedhotair.
RAIScannottakeresponsibilityforanybuildingworkorconsequential
damage.
Thestoveshouldbeinspectedfordefects atreceipt.
Liftthestovefromthepallettotheplaceofinstall ationontoasuitablyprotectedfloor.
Thestovecanbemountedontheoptionaladjustablestand(seepage29).
TheseareavailabletoorderfromyourlocalRaisdealer/stockist.
Usingaspiritlevelagainstthedoorandbodyofthestove,ensurethatthestoveis
perfectlylevelandmakeadjustmentsusingthelevellingboltsinthebase.
Removedoorfromthestove.Becarefulnottodamagetheglassorpaint.
Sealthefluepipeontotheflueoutletusingfirecementandselftappingscrewsand
connecttothechimney.
Installthefreshairinletconnectiontothepi pestub,ifrequired.
Thestoveisnowreadytobebuiltinusingeitherstudwallsorsolidwalls.
Whenthewallshavebeenfinishedanddecorated,thedoorcanberefitted.
Removeallprotectiveplasticandtapepriortocommissioning.
MadetomeasureframesareavailabletoorderwiththestovefromyourRaisdealer/
stockist.
ENGLISH RAISmanualforRais800
12
InsulationabilitysuchasAquapanel(coefficientofthermalconductivity0.36W/mk)
orbetter.Pleaseusemetalstud.
ENGLISH RAISmanualforRais800
13
ENGLISH RAISmanualforRais800
14
Insulatedfluepipe
fromthestove
ENGLISH RAISmanualforRais800
15
ENGLISH RAISmanualforRais800
16
Installationdistanceincaseofcombustiblewall
Tofindoutwhetherthewallnexttowherethestoveisgoingtobeinstalledisflammable,
youshouldcontactyourbuildingcontractororthelocalbuildingauthorities.
Thehearthshouldbeabletoaccommodatetheweightofthestove.Thechimneymust
beindependentlysupportedbywallbracketsoraceili ngsupportplate.Theweightofthe
stoveisindicatedinthebrochure.
Thestoveshouldalwaysbeinstalledonanoncombustiblehearthofasi zeand
constructionthatisinaccordancewiththeprovisionsofthecurrentUKBuilding
RegulationsApprovedDocumentJ.
Ifthestoveistobeinstalledonawoodenfloor,itmustbecoveredwitha
noncombustiblematerialatleast12mmthick,inaccordancewithUKBuilding
RegulationsApprovedDocumentJ,toadistanc eof300mminfrontofthestoveand
150mmtoeachsidemeasuringfromthedooroft hecombustionchamber.
Theclearancedistancestocombustiblematerialbeneath,surroundingoruponthe
hearthandwallsadjacenttothehearthshouldcomplywiththeguidanceonthe
separationofcombustiblematerialgiveninUKBuildingRegulationsApproved
DocumentJandalsointhesestoveinstructions.
Installationdistancesfornoncombustiblewall
Werecommendamini mumdistancetononcombustiblematerialof50mm(F)for
cleaningconsiderations.
Usinguninsulatedfluepipe,theminimumdistancetoacombustiblewallmustbe
450mmor225mmifthewallisheatshielded(seeSectionJoftheBuildingRegulations)
fromthefluepipe.
ENGLISH RAISmanualforRais800
17
FortheInstaller
Finallybeforefiringthestoveforthefirsttimeacheckshouldbemadetoensurethatthe
assemblyandstoveinstallationhasbeensatisfactoryandthattherearenoleaksinany
sealsintheapplianceandapplianceconnectionstothechimney.
Ensurethattheapplianceandchimneyfluearefunctioningcorrectlybeforefinally
handingovertotheuser.Readthelaterpartsofthismanualforguidanceoncare
requiredwhenfirstlighting.
Informtheuserthattheappliancehasbeencommissi onedandreadytouseandgive
instructiononthesafeoperationofthestove.
TheseInstructionsmustbeleftwiththeuserandt heusershouldbeinstructedtokeep
theminasafeplace.
ENGLISH RAISmanualforRais800
18
ONLYUSERECOMMENDEDFUELS
Thefollowingtableshowsthecalorificvalueofdifferenttypesofwood,whichhavebeen
storedfor2yearsandwhichhavearesidualmoistureof15 17%.
Wood Kgdrywoodprm
3
comparedtobeech/oak
Hornbeam 640 110%
Beechandoak 580 100%
Ash 570 98%
Maple 540 93%
Birch 510 88%
Mountainpine 480 83%
Fir 390 67%
Poplar 380 65%
1kgofwoodyieldsthesameheatenergyirrespectiveofwoodtype.
1kgofbeechmerelytakesuplessspacethan1kgoffir.
Operatinginstructions
PleasenotethatHETASApplianceApprovalonlycoverstheuseofdryseasonedwood
logsonthisappliance.HETASApprovaldoesnotcovertheuseofotherfuelseither
aloneormixedwiththewoodlogs,nordoesitcoverinstructionsfortheuseofother
fuels.
Fuel
ThestoveisdesignedandapprovedinaccordancewithEN13240andNS3058for
stokingsplit,driedfirewood.Thefirewoodmusthaveawatercontentof1522%andits
max.lengthshouldbethelengthofthecombustionchamberminus5060mm.
Stokingwithwetfirewoodcausesbothsoot,envi ronmentalpollutionandbadfuel
economy.Freshlycutwoodcontainsapprox.5070%waterandisthoroughlyunsuitable
forstoking.Allowatleast1yearofstoragetimefornewl ycutwoodbeforeusing.Wood
withadiameterofmorethan100mmshouldbesplit.Regardlessofwoodsize,itshould
alwayshaveatleastonesurfaceareafreeofbark.
Wedonotrecommendstokingwithpainted,laminatedorimpregnatedwood,woodwith
asyntheticsurface,paintedrefusewood,chipboard,plywood,domesticwaste,paper
briquettesandpitcoal,asthiswillproducemalodoroussmoke,whichcouldbe
poisonous.
Whenfiringwiththeabovementioneditemsandamountslargerthanthose
recommended,thestoveissubjectedtoalargeramountofheat,whichresultsina
higherchimneytemperatureandlowerefficiency.Thiscanresultinthestoveand
chimneybecomingdamagedandwouldvoidthewarranty.
Thecalorificvalueofthefirewoodiscloselyconnectedtothemoisturelevel.
Moistfirewoodhasalowheatvalue.Themorewatert hewoodcontains,themore
energyittakesforthiswatertovaporise,resultinginthisenergybeinglost.
ENGLISH RAISmanualforRais800
19
Dryingandstorage
Dryingwoodtakestime:properairdryingtakesapproximately2years.
Herearesometips:
Storethewoodsawn,splitandstackedinanairy,sunnyplace,whichisprotectedagainst
rain(thesouthsideofthehouseisparticularlysuitable).
Storethefirewoodstacksatahand'sbreadthapart,asthisensuresthattheairflowing
throughtakesthemoisturewithit.Avoidcoveringthefirewoodstackswithplastic,asthis
preventsthemoisturefromescaping.Itisagoodi deatobringthefirewoodintothehouse
23daysbeforeyouneedit.
Regulatingthecombustionair
AllRAISstovesareequippedwithaonehandedoperatingleverforreg ulatingthedamper.
Thestovespecificregulatingmechanismscanbeseenonthediagrams.
Primaryairisthecombustionairaddedtotheprimarycombustionzone,i.e.thebedof
glowingembers.Thisair,whichiscold,isonlyusedinthelightingstage.Secondaryairis
theairwhichisaddedinthegascombustionzone,i.e.airwhichcontributestothe
combustionofthepyrolysisgasses(preheatedair,whichisusedforthecleanerglass
systemandcombustion).Thisairissuckedthroughthedamperunderthecombusti on
chamberandispreheatedthroughthesid echannelsandthenemittedashotscavenging
airontotheglass.Thehotairrinsestheglassandkeepsitsootfree.
Thetertiarychannel,whichcanbeseenatthetopofthecombustionchambertowardsthe
back,servestocombustthefinalgasresidues.
Bysettingtheintervalbetweenposition1 and2,theenergycontentinthefirewoodisused
optimally,asthereisoxygenforcombustionandfortheburningofthepyrolysisgasses.
Whentheflamesareaclearyellowthedamperhasbeensetcorrectly.Findingthecorrect
positioncomeswithtimeafteryouhaveusedforstoveforawhile.
Itisnotrecommendedthatyouturnitdowncompl etely.Amistakecommonlymadeis
shuttingthedampertooearlybecauseitfeelstoohot.Thisresultsindarksmokeemanating
fromthechimneyandinthecalorificvalueofthefirewoodnotbeing usedtoitsfullest.
Roomventilationandstoves
Theremustnotbeanextractorfanfittedinthesameroomasthestoveasthiscancause
thestovetoemitsmokeandfumesintotheroom.
Thestoverequiresapermanentandadeq uateairsupplyinorderforittooperatesafelyand
efficiently.
InaccordancewithcurrentBuildingRegulationstheinstallermayhavefittedapermanentair
supplyventintotheroominwhichthestoveisinstalledtoprovidecombustionair.Thisair
ventshouldnotunderanycircumstancesbeshutofforsealed.
ENGLISH RAISmanualforRais800
20
Control
Iftheashiswhiteandthewallsinthecombustionchamberaresootfreeafterthestove
hasbeenused,theairregulationwasset correctlyandthewoodwassufficientlydry.
Usingthewoodburningstove
Adjustingtheairdamper.Thedamperhas3settings.
Position1
Thedamperisalmostclosedmeaningthatthereisa
minimalairintake.
Position2
Pushtheleveruntilthefirstclick.Thispositiongives
fullsecondaryair.
Duringnormalusetheleverissetbetweenposition1
and2.
Whentheflamesareclearandyellow,thedamperis
setcorrectly,i.e.resultinginaslow/optimalburning.
Position3
Pullthehandleout,andpushittotheright.
Theairdamperiscompletelyopenandgivesfull
primaryandsecondaryair.Thispositionisforthe
lightingstageandisnotusedundernormaloperation.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

RAIS 800 Instructions For Installation, Use And Maintenance Manual

Category
Wood stove
Type
Instructions For Installation, Use And Maintenance Manual

RAIS 800 is a wood-burning stove offering efficient and clean heating with a nominal output of 5kW, heating an area of approximately 100 square meters. It features a convection design for even heat distribution, boasts cool-touch door handles for safety, and provides intermittent operation with fuelings within 3 hours. Installation requirements include a suitable chimney with a minimum height of 4.5 meters and a diameter of at least 150mm, while maintaining a minimum distance to combustible walls.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI