5019 437 01011
Replacing the light bulb
Always disconnect the refrigerator from the power supply before replacing any
light bulb. If the inside light is not working, it is necessary to:
1. Remove the light cover: put your fingers into the side ventilation holes (1),
stretch the cover gently and move it upwards.
2. Check the bulb. If necessary unscrew the broken bulb and replace it with
the new one (use maximum 15W bulb).
3. Assemble again the light cover pushing it into place. Do not leave
uncovered the bulb.
GUIDE TO SELECTING FUNCTIONS
Functions and settings
Alarm deactivation - the user has to press two pushbuttons: temperature
setting and vacation mode simultaneously.
Fast Freezing: For more efficient freezing activate this function 24 hours
before freezing fresh products.
- Press steps by the “Temperature setting” button to start the function -
3 green indication lamps will light up simultaneously. After 24 hours place the
food to be frozen in the upper basket of the freezer compartment.
This function is automatically disabled after 24 hours. To deactivate it earlier:
-Press the “Temperature setting” button again - the temperature
selection lights will return to the 1
st
temperature level.
Temperature selection - It is possible to select the fridge/freezer
temperature from among 5 levels (level 1, level 2, level 3, level 4, level 5) by
pressing the temperature selection button .
Stand-by Mode / Cooling Off Mode.
It allows the user to turn ON or stand-by the product.
This function is enabled even if any alarm or failure appears.
• ON state: when the product is in the Stand-by state to “turn ON” press &
keep “Stand-by” pushbutton for 3 s.
• The product is turned ON;
• All functions should be enabled.
• STAND-BY state: when the product is ON and the user presses the
“Stand-by” pushbutton and keeps it pressed for 3 s, the appliance goes OFF.
• The appliance goes to STAND-BY when the user press and keep pushbutton
“Stand-by” for 3s.
• The product is turned OFF, disabling all loads
• All function shall be disabled;
• All lamps should be turned OFF;
• Turn off light.
Notes:
When the user presses at once “Stand-by” and “Temperature setting” to check
indication of the alarms (displayed by lamp 1 & lamp 2 & lamp 3) “Stand-by”
function is locked.
“Black-out” Alarm (power supply failure) - in case of power failure, the
appliance automatically monitors the temperature changes in the freezer
compartment. After the power supply returns,- the “Black-out” alarm will
activate, if the temperature has risen above the admissible level. This is
indicated by:
- Flashing of the green indicator lamps (4, 5, 6).
- Activation of a beep.
When the “Black-out” alarm is active, it is recommended to proceed as
follows:
- If the food in the freezer is not frozen but is still cold, transfer it promptly to
the refrigerator compartment and consume within 24 hours.
- If the food in the freezer is frozen, it has re-frozen after thawing caused by
the power failure. The consumption of re-frozen food is not recommended
because it has lost its nutritive value and may be hazardous to your health.
Note: The “Black-out” alarm does not guarantee the food quality and its
safety in case of consumption. It only indicates the necessity to assess the
quality of food in the freezer and refrigerator compartments. To deactivate the
alarm, press and hold “Temperature setting” pushbutton & party mode
button and keep pressed until the indicator light goes off.
- The temperature will return to the normal operating cycle level and the
beep will stop.
Other abnormal appliance operations displayed by indicator lamps.
In case of abnormal appliance operation, all the temperature selection indicator lamps will flash and a beep will sound. After pressing and holding the
“Temperature setting” & “stand-by” mode (“reset alarm”) buttons, the beep will stop and the indicator lamps will light up, showing the alarm code (possible
alarm codes are explained in the table below).
After the (“reset alarm”)button is released, the indicator lamps will flash until the fault is eliminated. If any alarm shown in the table occurs, the fridge/freezer
functions such as temperature adjustment and party mode are not available until the fault is eliminated.
When several alarms occur simultaneously, the alarm with the highest priority is displayed (with code 01 being the highest priority)
After determining the alarm code (between 01 and 05)
• The user can eliminate the reason for the code 04 alarm by closing the door completely.
• Code 05 alarm - The alarm deactivates when the minimum required temperature is reached.
• The other alarms (code 01, 02, 03) - Contact the After-Sales Service and provide the alarm code.
Alarm priority
Codification to be displayed by the Temperature Range Lamps
Lamp 1 Lamp 2 Lamp 3
FC Evaporator Temperature Sensor Alarm 01 OFF OFF ON
RC Evaporator Temperature Sensor Alarm 02 OFF ON OFF
RC Ambient Temperature Sensor Alarm 03 ON OFF OFF
Door Alarm 04 OFF OFF OFF
B.O.A 05 -- -