DEFROSTING THE REFRIGERATOR COMPARTMENT
Refrigerator compartment defrosting is completely automatic.
Droplets of water on the rear wall inside the refrigerator compartment
indicate that the automatic defrost phase is in progress. The defrost water
is automatically run into a drain hole and collected in a container, where it
evaporates.
DEFROSTING THE FREEZER COMPARTMENT
The freezer should be defrosted once or twice a
year or when excessive frost is present (3 mm
thickness). The formation of frost is normal. The
amount and rate at which frost accumulates
depends on room conditions and how often the
door is open. To defrost the unit, switch off the
freezer compartment or the whole appliance,
depending on the model, and remove all food
products. Leave the freezer door open to allow
the frost to melt. For appliances in figure only pull out the defrost water
drain and place a container under the drain. When the operation is
completed, put back the defrost water drain. Clean the inside of the
freezer. Rinse and dry thoroughly. Switch the freezer compartment, or the
whole appliance, back on and store the food inside.
REPLACING THE LIGHT BULB
Always disconnect the refrigerator from
the power supply before replacing any
light bulb. If the inside light is not working,
it is necessary to:
1. Remove the light cover: put the fingers into the side ventilation holes
(1), stretch the cover gently and move it upwards.
2. Check the bulb. If necessary unscrew the broken bulb and replace it
with the new one (use maximum 15W bulb).
3. Put on the light cover.
Do not leave the bulb uncovered.
GUIDE TO SELECTING FUNCTIONS
Functions and settings
Fast Freezing: For more efficient freezing activate this function 24 hours
before freezing fresh products.
- Select Freezer compartment by using button (1), LED (2) shall turn ON.
- Press and hold the temperature setting button Temp.°C until 3 green
LEDs light up simultaneously (4) (5) (6).
After 24 hours place the food to be frozen in the upper basket of the
freezer compartment.
This function is automatically disabled after 24 hours.
To deactivate it earlier follow the procedure:
- Press and hold by 3 sec. the temperature setting button Temp.°C again
while the LED (2) remains ON - the temperature selection lights will
return to previous displayed temperature setpoint.
Reset alarm
If any alarm appears, the user could reset the acoustical sound by pressing
once Reset alarm pushbutton.
"Black-out alarm" (power supply failure) - in case of power failure, the
appliance automatically monitors the temperature changes in the freezer
compartment after the power supply returns. The "Black-out alarm" will
activate, if the temperature has risen above the admissible level. This is
indicated by:
- Flashing of the green LED (2)
- Activation of a beep.
When the "Black-out alarm" is actived, it is recommended to proceed as
follows:
- If the food in the freezer is not frozen but is still cold, transfer it promptly
to the refrigerator compartment and consume within 24 hours.
- If the food in the freezer is frozen, it has re-frozen after thawing caused
by the power failure. The consumption of re-frozen food is not
recommended because it has lost its nutritive value and may be
hazardous to your health.
Note
The "Black-out alarm" does not guarantee the food quality and its safety
in case of consumption. It only indicates the necessity to assess the quality
of food in the freezer and refrigerator compartments.
To deactivate the alarm, press once Reset alarm pushbutton, the flashing
of the green LED (2) go off.
- The temperature will return to the normal operating cycle level and the
beep will stop.
Door open alarm
When the refrigerator compartment door remains open for more than 2
minutes, the beep is activated. When the door is closed the product
returns to normal operation, the beep will stop.
Overtemperature alarm in freezer compartment.
Overtemperature alarm activation is indicated by:
- Flashing of the green lamps (4) (5) (6).
- Activation of a beep.
The alarm is activated when:
• The appliance is connected to the power supply for the first time or
after prolonged disuse.
• The freezer compartment temperature is too high.
• The quantity of foods loaded into the freezer exceeds that indicated on
the data plate
• The freezer door has been left open for a long time .
To deactivate the beep of the alarm, press Reset alarm pushbutton. The
flashing LED s (4) (5) (6) go off when the minimum required temperature
is reached.
"6th Sense" function
The "6th Sense" function helps to maintain optimal conditions to storage
of food and is automatically activated when:
• a large amount of food is loaded into the freezer;
• the freezer door is left open for a long time;
• a prolonged power failure takes place, causing the internal temperature of
the appliance to increase to values that cannot guarantee safe storage of food.
Fresh Control
The Fresh Control is activated by default and is working only with Fan on.
To disactivate the Fresh Control function press for at least 3 sec. both
buttons Cavity selection "Fridge / Freezer" and "Temp.°C". A long sound
signal will be provided for the deactivation of the Fresh Control.
In order to activate this function follow the same procedure (keeping
pressed the 2 buttons for 3 sec.). A short sound signal will be provided for
the activation of the Fresh Control.
This function controls the fridge fan in order to optimize food
preservation in any ambient temperature conditions.
To minimize the Energy consumption is suggested to disable the Fresh
Control function and fan.
5019 637 01074
Printed in Poland 03/10
OTHER ABNORMAL APPLIANCE OPERATIONS DISPLAYED BY LEDs
In case of abnormal appliance operation, all the temperature selection LEDs will flash and one beep will sound. To check the code
alarm user have to press and hold the temperature setting Te m p . ° C & Reset alarm pushbuttons and alarm code will be showing on
the temperature LEDs (possible alarm codes are explained in the table below).
When this operation is released, the LEDs will flash until the fault is eliminated. If any alarm shown in the table occurs, the
fridge/freezer functions such as temperature adjustment, super freezing are not available until the fault is eliminated.
When several alarms occur simultaneously, the alarm with the highest priority is displayed (Number 1 being the highest priority).
Alarm Priority
Codification to be displayed by
temperature LEDs
Action
LED 4 LED 5 LED 6
Evaporator Temperature Sensor Alarm - Freezer compartment 1 Contact the After-Sales Service and provide the alarm code.
Evaporator Temperature Sensor Alarm - Fridge compartment 2 Contact the After-Sales Service and provide the alarm code.
Ambient Temperature Sensor Alarm - Fridge compartment 3 Contact the After-Sales Service and provide the alarm code.
Description: LED OFF LED ON