Prescribed use
The device is intended for non-contact measuring of temperatures of -50°C to
+1,000° C. As power supply, use a 9V block battery of the type 006P, IEC6F22,
NEDA 1604 or similar types only. Operate the device in dry environment only.
Do not expose it to moisture.
Any use other than one described above damages the
product. Moreover, this involves dangers such as e.g. short
circuit, fire, etc. No part of the product must be modified or
rebuilt and the housing must not be opened!
Scope of delivery
• Infrared Thermometer IR-1001A
• storing case
• 9V block battery
• operating Manual
Safety instructions
In the case of any damages which are caused due to the
failure to observe these operating instructions, the
guarantee will expire! We do not assume liability for
resulting damages!
Nor do we assume liability for damage to property or
personal injury caused by improper use or the failure to
observe the safety instructions. The guarantee will expire in
any such case.
An exclamation mark inside a triangle indicates important
instructions in the operating manual. Carefully read the
whole operating manual before putting the device into
operation.
The unauthorized conversion and/or modification of the unit is inadmissible
because of safety and approval reasons (CE).
Always observe the safety instructions, warnings and the chapter „Prescribed
use" in order to ensure safe operation.
Please observe the following notes before using the device:
• Do not operate the device in the proximity of welding machines, induction
heaters and other electromagnetic fields.
• After rapid temperature changes, the device needs approx. 15 minutes of
17
Mode key „Function“ (6)
The IR-1001A measures the following temperature values
during each measuring: maximum (MAX), minimum (Min),
difference (DIF) and average value (AVG). These values are
stored until the next measuring and can be recalled by means
of the mode key (6). The alarm values „High alarm” (HAL),
„Low alarm” (LAL) and emission ratio (EMS) can be set by
means of the mode key. Each time you are pressing the mode
key, the IR-1001A skips to another indicating / setting mode
(see figure). With each measuring, the maximum (MAX),
minimum (Min), difference (DIF) and average values (AVG) of
the old measuring are overwritten and new values are stored.
Setting the alarm values and the emission ratio
Select the value to be set by means of the mode key (6). Set
the desired value by means of the keys „Up" (5) and „Down"
(4).
To activate the alarm function (acoustic) set the sliding switch
„SET ALARM” inside the battery compartment to the right
position (symbols „High” and „Low“ (17) appear on the
display).
Locking function
The IR-1001A can be set to permanent measuring by means of the locking
function. To activate the permanent measuring, set the sliding switch „LOCK
Off/On" inside the battery compartment to „On" and press the measuring key
(8). To deactivate the permanent measuring, set the sliding switch to „Off".
During the permanent measuring, the laser and the background lighting can be
switched on or off by means of the „laser/ backlight" key (7).
substance emission ratio substance emission ratio
asphalt 0,90 - 0,98 glass 0,90 - 0,95
concrete 0,94 fabric (black) 0,98
cement 0,96 skin 0,98
sand 0,90 lacquer 0,80 - 0,95
earth 0,92 - 0,96 plastics 0,85 - 0,95
water 0,92 - 0,96 wood 0,90
ice 0,96 - 0,98 paper 0,70 - 0,94
snow 0,83 copper oxide 0,78
MAX
MIN
DIF
AVG
HAL
LAL
EM S