Midmark Procenter Systems Installation guide

Type
Installation guide

Midmark Procenter Systems are versatile delivery units designed for durability and flexibility in various healthcare settings. With a weight capacity of 50 lbs and a torque capacity of 170.8 ft-lbs, these systems can accommodate a range of equipment while ensuring stability. The adjustable arm allows for precise positioning, reaching a maximum height of 66.6 inches and a minimum height of 48.2 inches. Explore the convenience of effortless leveling, secure locking mechanisms, and easy tubing connections for a seamless integration into your operatory setup.

Midmark Procenter Systems are versatile delivery units designed for durability and flexibility in various healthcare settings. With a weight capacity of 50 lbs and a torque capacity of 170.8 ft-lbs, these systems can accommodate a range of equipment while ensuring stability. The adjustable arm allows for precise positioning, reaching a maximum height of 66.6 inches and a minimum height of 48.2 inches. Explore the convenience of effortless leveling, secure locking mechanisms, and easy tubing connections for a seamless integration into your operatory setup.

1© Midmark Corporation 2003 SF-1828
003-1292-00 Rev. LA2 (4/2/19)
Side Delivery Unit Installation
Mounting Location
NOTE:
Verify desired position
(ex. RH / LH) with
proper personnel before
installation.
Minimum Cabinet Size Requirements
(Side Delivery)
Flex Arm
Fixed Arm
Short Flex Arm
28 in. ( 71.1 cm)
Long Flex Arm
36 in. ( 91.4 cm)
Long Flex Arm
27.5 in. ( 69.8 cm)
Short Flex Arm
17 in. ( 43.2 cm)
55 to 61 in.
(139.7 to 154.9 cm)
12 to 24 in.
(30.4 to 60.9 cm)
CONTENTS
Mounting Location ............................................ 1
Minimum Cabinet Size Requirements ............. 1
Mounting Requirements ................................... 1
Regulator Installation........................................ 2
Cabinet Mount Bracket Installation .................. 2
Wall Mount Bracket Installation ........................ 3
Bearing Bracket Installation ............................. 4
Unit Arm Installation ......................................... 5
Stop Pin Installation ......................................... 5
Flex Arm Lock Activation & Leveling ............... 6
Tubing Connections .......................................... 7
Dimensions, Range of Motion ......................... 8
Mounting Requirements
Mounting Structure
The mounting structure must be capable of supporting the weight / torque listed below without deflection:
Unit / Arm Assembly
Weight (Maximum) ................. 50 lbs (22.6 kgs.)
Torque (Maximum) ................. 170.8 ft-lbs. (231.5 N•M)
To prevent the unit from drifting, the mounting plate must deflect
no more than 1/16" (1.6 mm) over a 12" (30.5) distance.
Electrical Requirements: 24VAC, 3.2 amp
13VAC, 2.0 amp
Style G
2
© Midmark Corporation 2003 SF-1828
Regulator Installation
Cabinet Mount Bracket Installation
(Cabinet Mount Units Only)
Needle Bearing
on Top.
Needle Bearing
on
Bottom.
3-5/8"
(9.2 cm)
8.0"
(20.3 cm)
2-3/4"
(6.9 cm)
Left Hand
Cabinet Mount
Right Hand
Cabinet Mount
14 3/4"
(37.5 cm)
Step 1:
Using the below dimensions,
mark position of four mounting
holes for bearing plate.
Use a 1/4" drill bit to drill holes.
NOTE:
Midmark Freestanding Center Console
cabinets are pre-drilled and it is not
necessary to do the following step.
Step 1:
Insert regulator assembly
into compression fitting of
shut-off.
Tighten compression fitting.
NOTE:
The bearing plate can be mounted
with the needle bearing at the top or
bottom.
It is recommended that the needle
bearing is positioned at the Top .
WATER REGULATOR
AIR REGULATOR
Regulator
Shut off
Valve
Compression
Fitting
Regulator
Shut off
Valve
Compression
Fitting
Return To Table Of Contents
3© Midmark Corporation 2003 SF-1828
Cabinet Mount Bracket Installation
(continued)
(Cabinet Mount Units Only)
Bearing
Plate
Shim
Backing
Plate
Level
NOTE:
Backing Plate is not required
on Midmark Freestanding
Center Console Cabinets.
Step 2:
Align mounting holes and install
appropriate mounting bolts.
Bolts are provided in 1" and
2 1/4" lengths.
Step 3:
Loosen bolts and level bearing
mounting plate. Use shims, if
necessary, then tighten bolts.
Wall Mount Bracket Installation
(Wall Mount Units Only)
Floor
Needle
Bearing
on Top.
16-7/16"
(41.7 cm)
66-5/8"(169.3 cm)
Long Fixed & Flex Arms
48-1/8"(122.3 cm)
Short Fixed & Flex Arms
21-11/16"
(55 cm)
NOTE:
Wall mounted units may be mounted at
any height.
Verify position with proper personnel.
NOTE:
Product can be configured to use either
Fixed Arm with either Flex Arm.
NOTE:
The bearing plate can be mounted
with the needle bearing at the top or
bottom.
It is recommended that the needle
bearing is positioned at the Top .
Return To Table Of Contents
4
© Midmark Corporation 2003 SF-1828
Wall Mount Bracket Installation
(Wall Mount Units Only)
Equipment Alert
Mounting Holes MUST be aligned with wall studs.
Failure to comply could cause delivery unit to fall
and damage unit and wall structure.
Wall Studs
Step 3:
Install mounting
cover using
4 #10-32 x 3/8"
screws.
Step 2:
Secure frame
to wall with 8
(5/16"x 2 1/2")
lag screws.
Step 1:
Locate wall studs.
Align 8 holes in mounting
plate with studs.
Mark and drill pilot holes
(Use 1/4" drill bit).
Bearing Bracket Installation
Step 1: Align mounting holes in bearing
plate and frame cover.
Install four screws
Step 2: Loosen bolts and level bearing
mounting plate. Use shims, if
necessary, then tighten bolts.
Bearing
Plate
Frame Cover
Shim
Level
Needle
Bearing
NOTE:
The bearing plate can be mounted
with the needle bearing at the top or
bottom.
It is recommended that the needle
bearing is positioned at the Top .
Return To Table Of Contents
5© Midmark Corporation 2003 SF-1828
Unit Arm Installation
(Cabinet & Wall Mount Units)
Set
Screw
Step 2:
Apply lubricant, supplied
with arm assemby, to
Fixed Arm.
Step 3:
Route umbilical tubing
thru bearing and slide
Fixed Arm into bearing.
Equipment Alert
All pivots points must be secure when installing
unit arm. Failure to comply could result in equip-
ment damage.
Bearing
Cover
Retainer
Bearing
Step 5:
Trim umbilical sleeve.
Slide sleeve over
tubing & wiring.
Install and secure
umbilical retainer.
Step 6:
Install bearing
cover.
Step 7:
Install water
bottle.
Step 8:
Connect tubing.
(Refer to Tubing Diagram).
Trim Ring
Stop Pin
Rotation
Stop
Screw
Position
A
Position
B
Rotation
Stop
Screw
Trim
Ring
Stop
Pin
Flex Arm
Fixed Arm
Stop
Pin
Stop Pin Installation
(Cabinet & Wall Mount Units)
Step 1:
Position Flex and
Fixed Arms as
shown.
Step 3:
Rotate flex arm to desired
position and install stop pins.
Step 2:
Lift trim
ring.
NOTE:
The stop pins can be placed
in two positions, as determined
by rotational stop screw.
Verify desired position with
customer.
Step 4:
Adjust drag by loosening / tightening
set screw.
Step 1:
Loosen set screw.
Return To Table Of Contents
6
© Midmark Corporation 2003 SF-1828
2
4
1
3
DA115102i
To level the delivery unit...
A. Remove bottom cover.
B. Slightly loosen button head screws.
C. Adjust leveling screws until delivery
unit is level.
D. Tighten button head screws.
E. Install cover.
To activate flex arm lock...
A. Remove end cap.
B. Slide cover back to access
locking pawls.
C. Cut and remove wire tie.
D. Slide cover in position and install
end cap.
Locking
Pawls
Wire Tie
Button
Head
Screws
Leveling
Screws
Flex Arm Lock Activation /
Leveling the Delivery Unit.
NOTE:
The following procedures should be performed after
installation of entire operatory is complete.
Return To Table Of Contents
7© Midmark Corporation 2003 SF-1828
80 PSI
30 PSI
Tubing Connections
Return To Table Of Contents
8
© Midmark Corporation 2003 SF-1828
Midmark Corporation
60 Vista Drive
P.O. Box 286
Versailles, OH 45380-0286
937-526-3662
Fax 937-526-5542
www.midmark.com
Long Flex Arm
24 in. ( 60.9 cm)
Short Flex Arm
16 in. ( 40.6 cm)
Short Fixed Arm
13.5 in. ( 34.3 cm)
Long Fixed Arm
24 in. ( 60.9 cm)
180°
180°
Dimensions, Range of Motion
135°
135°
30°
Long Flex Arm
12.5 in. ( 31.7 cm)
Short Flex Arm
8.3 in. ( 21.1 cm)
Max.
*
66.6 in. (169.3 cm)
Min.
**
48.2 in. (122.3 cm)
Short Fixed Arm
13.5 in. ( 34.3 cm)
Long Flex Arm
24 in. ( 60.9 cm)
Short FlexArm
16 in. ( 40.6 cm)
Long Flex Arm
24 in. ( 60.9 cm)
Max.
*
66.6 in.
(169.3 cm)
Min.
**
48.2 in.
(122.3 cm)
* Measurement w/ long fixed arm & long flex arm (Standard w/ wall mounted unit ).]
** Measurement w/ short fixed arm & short flex arm (Standard w/ cabinet mounted unit).
NOTE:
Product can be configured to use
either fixed arm w/ either flex arm.
Return To Table Of Contents
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Midmark Procenter Systems Installation guide

Type
Installation guide

Midmark Procenter Systems are versatile delivery units designed for durability and flexibility in various healthcare settings. With a weight capacity of 50 lbs and a torque capacity of 170.8 ft-lbs, these systems can accommodate a range of equipment while ensuring stability. The adjustable arm allows for precise positioning, reaching a maximum height of 66.6 inches and a minimum height of 48.2 inches. Explore the convenience of effortless leveling, secure locking mechanisms, and easy tubing connections for a seamless integration into your operatory setup.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI