urmet domus MT124-013 Technical Manual

Category
Door intercom systems
Type
Technical Manual
sec. 3i
____
1
BIBUS 2
nd
Ed. VOP - Technical Manual
SECTION 3I
PANEL WITH DOOR UNIT
AND DIGITISER
LOUDSPEAKING UNIT WITH INTEGRATED
DIGITALIZER Ref.1072/8 ..................................................................2
Performance .................................................................................2
Structure .......................................................................................2
Description of terminal boards .....................................................2
Technicalspecications ...............................................................2
Default programming ....................................................................3
Connections .................................................................................3
Function ........................................................................................3
Adjustments ..................................................................................3
16-PUSHBUTTON EXPANSION MODULE Ref.1083/17 .................. 4
Technicalspecications ...............................................................4
SINTHESI STEEL PUSH BUTTON panels ........................................4
Camera unit module Ref.1758/40 ................................................4
Product list ...................................................................................5
Installation ....................................................................................6
DIMENSIONS ...................................................................................8
DOOR PHONES SYSTEMS
Modularity examples for different system dimensions .................9
VIDEO DOOR PHONES SYSTEMS
Modularity examples for different system dimensions ...............13
Download from www.urmet.com Technical Manuals area.
SECTION CONTENTS
2
____
sec. 3i
BIBUS 2
nd
Ed. VOP - Technical Manual
PUSH BUTTONS PANELS
LOUDSPEAKING UNIT WITH INTEGRATED
DIGITALIZER Ref.1072/8
PERFORMANCE
Installable in Sinthesi Steel frames.
17 user terminal pins, that can be directly connected to buttons
and 1 pre-wired call button.
Connector for 16 user expansion module Ref.1083/17.
Maximum four expansion modules (connected in series) for
maximum 82 user buttons in each door unit.
Possibility of assigning alphanumeric call button code with letter
prexorsufxA-J.
The digitiser is programmed by means of an external programming
device Ref.1072/60 which in turn must be connected to a push-
button panel Ref.1032/65.
SimpliedprogrammingwithLEDbuttonandtwodip-switchesin
simple systems.
Possibility of programming one or more buttons for controlling a
special decoder (“staircase lights” function).
Electrical relay load control actuator with NC-C-NO outputs and
programmable activation time, from 1 to 30s.
Programmable door phone hang-up waiting time (10, 20, 30,
40s).
Programmable minimum guaranteed conversation time (10, 20,
30, 40s).
Maximum conversation time: 250s.
Open door contact input.
Hall button timed input.
Acoustic call sent signal.
Busy function signalled by busy tone when a button is pressed to
busy time-out.
Two trimmers for adjusting speaker and microphone volume.
Opto-isolated control signal management for video door phone
systems.
Possibility of programming a pre-set button for direct switchboard
calls (day state only).
Management of audio repeater device for hard of hearing people
and module with voice messages and led.
SINTHESI STEEL PUSH BUTTON PANEL
LOUDSPEAKING UNIT WITH INTEGRATED DIGITALIZER
STRUCTURE
The digitiser consists of the following parts:
2
3
4
5
6
7
8
9 10
11
1
default
Speaker volume adjustment trimmer.
Microphone volume adjustment trimmer.
SimpliedprogrammingLEDandbutton.
Programming connector for adapter Ref.1072/60 and keyboard
Ref. 1032/65.
Simpliedprogrammingdip-switch.
Pre-wired call button.
Terminal board for system connection.
Connector (I2C) for module with voice messages and led
Ref.1158/47
ILA connector for hard of hearing device.
Connector (EXP) for 16 user expansion modules Ref.1083/17.
Terminal board for connecting buttons.
DESCRIPTION OF TERMINAL BOARDS
System terminal boards
~12
}
Relay power for electrical lock
~0
NO Electrical lock relay normally open contact
NC Electrical lock relay normally closed contact
C Relay exchange electrical lock common contact
R1 Video power earth
GND Reference earth PA, SP
R
Video switching enable signal for video door phone
systems
SP
Open door sensor contact input
(closed with closed door)
PA Hall door opener button input (normally open)
SN
Video power unit on signal for video door phone
systems
L2 Bus Line 2
nd
connector
L1 Bus Line 1
st
connector
Button terminal boards
P2÷P18 User button inputs
C Button reference earth
P1 terminal pin is not present because the button is already
pre-wired inside the device
TECHNICAL SPECIFICATIONS
Stand-by consumption: .................................................... 6,5 mA max
Active voice consumption: ................................................ 40 mA max
Relay contact: ........................................................................ 30 V 2 A
R, SN signal: .................................................................. Imax = 80 mA
Working temperature range:............................................... -10 ÷ 50°C
Humidity: .................................................................... 90% UR a 30°C
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
LOUDSPEAKING UNIT WITH INTEGRATED DIGITALIZER
Ref.1072/8
sec. 3i
____
3
BIBUS 2
nd
Ed. VOP - Technical Manual
PUSH BUTTONS PANELS
DEFAULT PROGRAMMING
Refer to section 1A “Programming” in this manual for how
to program the device.
The device default settings are:
System type: .......................................................................2
nd
edition
Station type: ................................................................................main
Code format: ..................................................... numeric (0001–9999)
Station number: .................................................................................. 1
Off-hook waiting time: ................................................................... 40 s
Busy time: ...................................................................................... 20 s
Door opener time: ........................................................................... 3 s
Code button association:
LLLL P1
1002 P2
. .
. .
. .
1082 P82
To restore default settings, insert the programming device and hold
bs (back-space) button pressed for longer than three seconds until
you hear a beep. Alternatively, without the programming device, hold
the programming button (3) pressed for longer than three seconds
until you hear a beep.
CONNECTIONS
IMPORTANT: Observe the instructions contained in section 1 for
wiring and maximum distances.
Besides the pre-wired button, 17 user buttons max. can be directly
connected to the door unit. When a higher number of user is required,
a Ref. 1083/17 expansion module can be connected. This allows
the addition of 16 user buttons to the 18 basic buttons. Up to four
expansion units can be connected to each door unit, for a total of 82
user buttons.
Position two call units side by side if a station with more than 82 users
is required. The door unit is programmed by default with a jumper
between the earth and the “SP” signal to simulate the door closed
contact. Remove the jumper and connect the sensor between GND
and SP when the open door contact is required.
Internal calling station circuits are power by bus voltage.
FUNCTION
CALLS
Up to 82 users can be called by pressing the corresponding buttons
on the panels associated to the door unit with digitiser Ref. 1072/8.
Additionally, a concierge switchboard Ref. 1072/42 can be called,
simply by pressing a call button associated to code 0000 during
programming (day mode only). A courtesy ring, similar to that
generated on a called door phone, will be heard.
STAIRCASE LIGHTS FUNCTION
Press the button programmed for this function. A command will be
senttothespecialdecoderandaconrmationbeepwillbeheard.
The staircase light function is assigned to button P1 by default.
If the staircase lights button is pressed during the
programming procedure, it will be reprogrammed with the
user code corresponding to the position.
BUSY FUNCTION
This function is only required in systems with more than one calling
device. This function is used to ensure that a conversation lasts
sufcientlylongfollowingacall.Anintermittentbeepwillbeheardon
the speaker for the time before the busy time-out and the panel will
be disabled.
Two cases can occur:
Busy time before the call user goes on-hook
This is the maximum time for the user to lift the handset or open
the door without loosing the call after the ring.
Busy time after user goes on-hook
This is the minimum guaranteed conversation time from when the
handset is lifted.
ADJUSTMENTS
VOLUME REGULATION
Volume levels are calibrated by default so not to require adjustments
in most cases.
Use a screwdriver to adjust the trimmers if required.
TROUBLESHOOTING
Establishing the cause of problems related to a door unit with digitiser
Ref. 1072/8 is simple (e.g. no courtesy tone after a call button is
pressed):
Short-circuit on push-button panel side (L1, L2).
Neither bus couplers are programmed as masters.
SINTHESI STEEL PUSH BUTTON PANEL
LOUDSPEAKING UNIT WITH INTEGRATED DIGITALIZER
LOUDSPEAKING UNIT WITH INTEGRATED DIGITALIZER
Ref.1072/8
4
____
sec. 3i
BIBUS 2
nd
Ed. VOP - Technical Manual
PUSH BUTTONS PANELS
16-PUSHBUTTON EXPANSION MODULE
Ref.1083/17
The extension module can be used to add 16 user buttons to the
door unit.
Arrange the device in the push-button panels, as shown in the
followinggure.
Connect the user buttons and connect the device to the door unit and
tootherextensionsbymeansofthespecicwire.Respectthe
connectionsandtheholesintheushmountingboxes.
INSTALLATION ON MODULES WITH 3 AND 4 BUTTONS
1
2
4
3
push-buttons
module
INSTALLATION ON MODULES WITH 1 AND 2 BUTTONS
3
4
G/T
(*)
U1
U2
1
2
push-buttons
module
(*) red
TECHNICAL SPECIFICATIONS
Consumption: ..................................................................... 1 mA Max
Current in user button: ............................................................. ~1 mA
Working temperature range: ................................................+0 ÷ 50°C
Humidity: ..................................................................90% UR at 30°C
SINTHESI STEEL PUSH BUTTON PANEL
16-PUSHBUTTON EXPANSION MODULE
CAMERA UNIT MODULE
SINTHESI STEEL PUSH BUTTON PANELS
Sinthesi Steel is a vandal resistant push button panel made of steel,
suitable for harsh environment.
Sinthesi Steel is the evolution of Sinthesi push button panel, with the
same modular structure. For this reason, with a reduced number of
components and shelf items cards it is possible to realize any types
andcongurationsofpushbuttonpanels.
The product range continuity is guaranteed by the possibility to use
SinthesiSteeldeviceswhentheexistingushmountboxistheone
used for Sinthesi or K-Steel push button panels.
Special care has been dedicated to new modules, optimized to
make installation quicker by using pre-cabled wires with connectors,
implementing new modules as DDA (Disability Discrimination Act)
used to know system operation and ILA (Induction loop Antenna)
modules, that allow hard of hearing people provided with hearing aid
with T operating mode, to hear the door phone conversation.
CAMERA UNIT MODULE Ref.1758/40
Ref. 1758/40 cameras are composed by a single Sinthesi Steel
module provided with a camera with embedded lens and shutter and
leds used to light up the subject. These devices can be used both in
systems with coaxial cable and in systems with differential video..
(default)
A - B
Differential
video system
V3 - V5
System with
coaxial cable
Camera leds off
Camera leds on
For installation in Bibus II^ed. VOP systems, the jumper
must be set to A-B differential video system mode.
16-PUSHBUTTON EXPANSION MODULE
CAMERA UNIT MODULE
Ref.1083/17
Ref.1758/40
sec. 3i
____
5
BIBUS 2
nd
Ed. VOP - Technical Manual
PUSH BUTTONS PANELS
TECHNICAL SPECIFICATIONS
Power voltage: ...........................................................................18 Vdc
Maximum uptake: .................................................................... 250 mA
Image sensor: ....................................................................... 1/3” CCD
Lens: ...................................................................................... standard
Shutter: .................................................................................. standard
Focus: ...........................................................................................xed
Minimum light for a good image:............................................... 0,2 lux
A-B video output: .................................................... 1 Vpp differential
Operating temperature range: ............................................ -10 ÷ 50°C
IMAGING ANGLES
0,8 m
0,9 m
1,0 m
85°
1,0 m
1,7 m 1,7 m
120°
Vertical
Horizontal
DESCRIPTION OF TERMINALS
V3 Video signal for systems with coaxial cable (not used)
V5
Video signal ground for systems with coaxial cable (not
used)
R1 Camera power negative
+TC Camera power positive
A
}
Video signal for differential video systems
B
T Camera power-on drive
R2 Camera power supply positive signal
PRODUCT LISTS
All Sinthesi Steel products, their characteristics and installation
modes are described in Products Technical Manual - Door Phone
and Video Door Phone system in the section Sinthesi Steel Push
Button Panel
BUTTONS MODULES
With 1 button .................................................................. Ref. 1158/11
With 2 buttons ................................................................Ref. 1158/12
With 3 buttons ................................................................Ref. 1158/13
With 4 buttons ................................................................Ref. 1158/14
SPECIAL MODULES
Directory module ............................................................ Ref. 1158/50
Blind module ..................................................................Ref. 1158/59
DDA module with voice messages .................................. Ref. 1158/47
Hearing impaired people module ....................................Ref. 1158/48
METAL FLUSH MOUNT BOXES
For 1 module ..................................................................Ref. 1158/41
For 2 modules ................................................................Ref. 1158/42
For 3 modules ................................................................Ref. 1158/43
For 4 modules ................................................................Ref. 1158/44
PLASTIC FLUSH MOUNT BOXES
For 1 module ..................................................................Ref. 1145/51
For 2 modules ................................................................Ref. 1145/52
For 3 modules ................................................................Ref. 1145/53
For 4 modules ................................................................Ref. 1145/54
FRAMES AND MODULE HOLDERS
For 1 module ..................................................................Ref. 1158/61
For 2 modules ................................................................Ref. 1158/62
For 3 modules ................................................................Ref. 1158/63
For 4 modules ................................................................Ref. 1158/64
RAIN HOODS
For 1 module ................................................................Ref. 1158/611
For 2 modules ..............................................................Ref. 1158/612
For 3 modules ..............................................................Ref. 1158/613
For 4 modules ..............................................................Ref. 1158/614
For 4 modules (2 module holders with 2 modules) ......Ref. 1158/624
For 6 modules (2 module holders with 3 modules) ......Ref. 1158/626
HOODED HOUSINGS
For 1 module ................................................................Ref. 1158/311
For 2 modules ..............................................................Ref. 1158/312
For 2 modules ..............................................................Ref. 1158/313
For 2 modules ..............................................................Ref. 1158/314
SINTHESI STEEL PUSH BUTTON PANEL
CAMERA UNIT MODULE
PRODUCT LIST
CAMERA UNIT MODULE
PRODUCT LIST
Ref.1758/40
6
____
sec. 3i
BIBUS 2
nd
Ed. VOP - Technical Manual
PUSH BUTTONS PANELS
SINTHESI STEEL PUSH BUTTON PANEL
INSTALLATION
INSTALLATION
You are advised to install the modules at the heights shown below
accordingtotherequiredsystemconguration.
1,55 ÷ 1,60 m 1,55 ÷ 1,60 m
Inanycase,considertheheightshowninthegureforfasteningthe
camera for correct installation of complex arrangement with several
modules. The height refers to the door unit in door phone systems.
Arrange the hole (on the bottom or on the sides) for letting through
theconnectionwiresbeforeclosingtheush-mountingbox(single
or joined to other boxes).
1
2
A
L
TO
TOP
HAUT
metal boxes plastic boxes
Fit the ush mounting box in line with the wall: it must not
project.
Apply the adhesive labels on the frame screw holes before
installing the box.
Fit the module holder frame.
metal boxes
plastic boxes
Fit the modules in the frame.
Turn the frame round and connect wires.
Close the module holder.
Adjust correct perpendicularity of the panel.
metal boxes
plastic boxes
SINTHESI STEEL PUSH BUTTON PANEL
sec. 3i
____
7
BIBUS 2
nd
Ed. VOP - Technical Manual
PUSH BUTTONS PANELS
Fit the name tags.
Fit the panel on the frame.
SINTHESI STEEL PUSH BUTTON PANEL
INSTALLATION
SINTHESI STEEL PUSH BUTTON PANEL
Dummy transparent name holder.
Final engraved name holder.
8
____
sec. 3i
BIBUS 2
nd
Ed. VOP - Technical Manual
PUSH BUTTONS PANELS
FLUSH-MOUNTED VERSION
119mm 45mm
H1
125mm
H2
247mm 45mm
H1 H2
254mm
376mm 45mm
H1
H2
383mm
505mm 45mm
H1
H2
512mm
H2
641mm
H1
634mm
45mm
WALL-MOUNTED VERSION
157mm
H3
79mm
59mm
SINTHESI STEEL PUSH BUTTON PANEL
DIMENSIONS
H3
For 1 module 151,5 mm
For 2 modules 241,5 mm
For 3 modules 331,5 mm
For 4 modules 421,5 mm
H1 H2
For 1 module 117 mm 127 mm
For 2 modules 207 mm 217 mm
For 3 modules 297 mm 307 mm
For 4 modules 387 mm 397 mm
SINTHESI STEEL PUSH BUTTON PANEL - DIMENSIONS
sec. 3i
____
9
BIBUS 2
nd
Ed. VOP - Technical Manual
PUSH BUTTONS PANELS
SINTHESI STEEL PUSH BUTTON PANEL
DOOR PHONE SYSTEMS
MODULARITY EXAMPLES FOR DIFFERENT SYSTEM DIMENSIONS
SINTHESI STEEL PUSH BUTTON PANEL - DOOR PHONE SYSTEMS
BUTTONS NUMBER
1 2 3 4 5 6 7 8 9 10 10
h
11 11
h
12 12
h
13 13
h
14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29
Button
modules
1158/11
1 1 1 1 1 1 1 1
1158/12
1 1 1 1 1 1 1 1
1158/13
1 1 1 1 1 1 1 1
1158/14
1 1 1 1 2 2 2 2 2 2 2 3 3 3 3 3 4 4 4 4 5 5 5 5 6 6 6 6 7
Special
modules
1158/50
1 1 1 1 1 1 1 1
Door unit
modules
1072/8
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Expansion
module
1083/17
1 1 1 1 1 1 1 1 1 1 1
Flush
mounting
box (*)
1158/41
1
1158/42
1 1 1 1 2 2 2 2
1158/43
1 1 1 1 2 2 2 2 2 2 2 2
1158/44
1 1 1 1 2 2 2 2 2 2 2 2
Module
holders and
frames
1158/61
1
1158/62
1 1 1 1 2 2 2 2
1158/63
1 1 1 1 2 2 2 2 2 2 2 2
1158/64
1 1 1 1 2 2 2 2 2 2 2 2
Rain hood
1158/611
1
1158/612
1 1 1 1
1158/613
1 1 1 1
1158/614
1 1 1 1
1158/624
1 1 1 1
1158/626
1 1 1 1 1 1 1 1
Case with
hood (**)
1158/311
1
1158/312
1 1 1 1
1158/313
1 1 1 1
1158/314
1 1 1 1
BUTTONS NUMBER
30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61
Button
modules
1158/11
1 1 1 1 1 1 1 1
1158/12
1 1 1 1 1 1 1 1
1158/13
1 1 1 1 1 1 1 1
1158/14
7 7 7 8 8 8 8 9 9 9 9 10 10 10 10 11 11 11 11 12 12 12 12 13 13 13 13 14 14 14 14 15
Special
modules
1158/50
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1158/59
1 1 1 1 1 1 1 1
Door unit
modules
1072/8
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Expansion
module
1083/17
1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 3 3 3
Flush
mounting
box (*)
1158/43
3 3 3 3 5 5 5 5 5 5 5 5 5 5 5 5
1158/44
3 3 3 3 3 3 3 3 3 3 3 3 4 4 4 4
Module
holders and
frames
1158/63
3 3 3 3 5 5 5 5 5 5 5 5 5 5 5 5
1158/64
3 3 3 3 3 3 3 3 3 3 3 3 4 4 4 4
(*) plastic boxes can also be used, according to the following codes matching:
Metal boxes
{
1158/41
1145/51
}
Plastic boxes
1158/42
1145/52
1158/43
1145/53
1158/44
1145/54
(**)Insteadofproductsforushmountinginstallation:ushmountboxes,framesandmodule-holderframesandrainhoods.
10
____
sec. 3i
BIBUS 2
nd
Ed. VOP - Technical Manual
PUSH BUTTONS PANELS
1 2 3 4 5 6 7 8 9
10
11 12 13
14 15 16 17 18 19
20 21 22 23 24 25
26 27 28 29 30
10h 11h 12h 13h
SINTHESI STEEL PUSH BUTTON PANEL
DOOR PHONE SYSTEMS
MODULARITY EXAMPLES FOR DIFFERENT SYSTEM DIMENSIONS
SINTHESI STEEL PUSH BUTTON PANEL - DOOR PHONE SYSTEMS
sec. 3i
____
11
BIBUS 2
nd
Ed. VOP - Technical Manual
PUSH BUTTONS PANELS
34
35 36 37
38
39 40 41
42
43 44 45
46
47 48
31 32 33
49
SINTHESI STEEL PUSH BUTTON PANEL
DOOR PHONE SYSTEMS
MODULARITY EXAMPLES FOR DIFFERENT SYSTEM DIMENSIONS
SINTHESI STEEL PUSH BUTTON PANEL - DOOR PHONE SYSTEMS
12
____
sec. 3i
BIBUS 2
nd
Ed. VOP - Technical Manual
PUSH BUTTONS PANELS
52
53 54
55
56 57
59 60
61
58
50 51
SINTHESI STEEL PUSH BUTTON PANEL
DOOR PHONE SYSTEMS
MODULARITY EXAMPLES FOR DIFFERENT SYSTEM DIMENSIONS
SINTHESI STEEL PUSH BUTTON PANEL - DOOR PHONE SYSTEMS
sec. 3i
____
13
BIBUS 2
nd
Ed. VOP - Technical Manual
PUSH BUTTONS PANELS
SINTHESI STEEL PUSH BUTTON PANEL
VIDEO DOOR PHONE SYSTEMS
MODULARITY EXAMPLES FOR DIFFERENT SYSTEM DIMENSIONS
SINTHESI STEEL PUSH BUTTON PANEL - VIDEO DOOR PHONE SYSTEMS
BUTTONS NUMBER
1 2 3 4 5 6 6
h
7 7
h
8 8
h
9 9
h
10
h
11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
Button modules
1158/11
1 1 1 1 1 1 1 1
1158/12
1 1 1 1 1 1 1 1
1158/13
1 1 1 1 1 1 1
1158/14
1 1 1 1 1 1 1 1 2 2 2 2 3 3 3 3 4 4 4 4 5 5 5 5 6 6 6
Special modules 1158/50
1 1 1 1 1 1 1 1
Door unit modules 1072/8
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Camera modules 1758/40
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Expansion module 1083/17
1 1 1 1 1 1 1 1 1
Flush mounting
box (*)
1158/42
1 2 2 2 2
1158/43
1 1 1 1 2 2 2 2 2 2 2 2 3 3
1158/44
1 1 1 1 2 2 2 2 2 2 2 2
Module holders and
frames
1158/62
1 2 2 2 2
1158/63
1 1 1 1 1 2 2 2 2 2 2 2 2 3 3
1158/64
1 1 1 2 2 2 2 2 2 2 2
Rain hood
1158/612
1
1158/613
1 1 1 1
1158/614
1 1 1 1
1158/624
1 1 1 1
1158/626
1 1 1 1 1 1 1 1
Case with hood
(**)
1158/312
1
1158/313
1 1 1 1
1158/314
1 1 1 1
BUTTONS NUMBER
28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57
Button modules
1158/11
1 1 1 1 1 1 1
1158/12
1 1 1 1 1 1 1
1158/13
1 1 1 1 1 1 1 1
1158/14
6 7 7 7 7 8 8 8 8 9 9 9 9 10 10 10 10 11 11 11 11 12 12 12 12 13 13 13 13 14
Special modules
1158/50
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1158/59
1 1 1 1 1 1 1 1
Door unit modules 1072/8
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Camera modules 1758/40
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Expansion module 1083/17
1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3
Flush mounting
box (*)
1158/43
3 3 5 5 5 5 5 5 5 5 5 5 5 5
1158/44
3 3 3 3 3 3 3 3 3 3 3 3 4 4 4 4
Module holders and
frames
1158/63
3 3 5 5 5 5 5 5 5 5 5 5 5 5
1158/64
3 3 3 3 3 3 3 3 3 3 3 3 4 4 4 4
(*) plastic boxes can also be used, according to the following codes matching
Metal boxes
{
1158/42
1145/52
}
Plastic boxes1158/43
1145/53
1158/44
1145/54
(**)Insteadofproductsforushmountinginstallation:ushmountboxes,framesandmodule-holderframesandrainhoods.
14
____
sec. 3i
BIBUS 2
nd
Ed. VOP - Technical Manual
PUSH BUTTONS PANELS
SINTHESI STEEL PUSH BUTTON PANEL
VIDEO DOOR PHONE SYSTEMS
MODULARITY EXAMPLES FOR DIFFERENT SYSTEM DIMENSIONS
SINTHESI STEEL PUSH BUTTON PANEL - VIDEO DOOR PHONE SYSTEMS
8 9
18
22
8h 9h
1 2 3 4 5 6
10 11 12
13 14 15 16 17
19 20 21 23 24
25
26
27 28 29
6h 7 7h
sec. 3i
____
15
BIBUS 2
nd
Ed. VOP - Technical Manual
PUSH BUTTONS PANELS
SINTHESI STEEL PUSH BUTTON PANEL
VIDEO DOOR PHONE SYSTEMS
MODULARITY EXAMPLES FOR DIFFERENT SYSTEM DIMENSIONS
SINTHESI STEEL PUSH BUTTON PANEL - VIDEO DOOR PHONE SYSTEMS
30
34
38
42
31 32 33
35 36 37
39 40 41
43 44
45 46 47
16
____
sec. 3i
BIBUS 2
nd
Ed. VOP - Technical Manual
PUSH BUTTONS PANELS
SINTHESI STEEL PUSH BUTTON PANEL
VIDEO DOOR PHONE SYSTEMS
MODULARITY EXAMPLES FOR DIFFERENT SYSTEM DIMENSIONS
SINTHESI STEEL PUSH BUTTON PANEL - VIDEO DOOR PHONE SYSTEMS
51
54
48 49
50
52 53
55
56
57
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

urmet domus MT124-013 Technical Manual

Category
Door intercom systems
Type
Technical Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI