www.esabna.com
DATE: January 22, 2004 BULLETIN NO: M-04-001
TITLE/ PRODUCT NAME: Power Source Faults When Connecting
DuraDrive Wire Feeder
RATING:
_
_ DIRECTIVE _X_ ALERT
(Action is Required) (Potential Problem)
_
X_ INFORMATION _ _ PRODUCT IMPROVEMENT
(Action is Optional) (Enhanced Product)
_
X_ General Distribution _ _ Business Confidential
(Unrestricted) (Restricted Distribution)
PRODUCT SERIES/ MODEL:
ESAB 353cv, 453cv and 653cvcc Power Sources
Control Board PN 38129 & 38130
SERIAL NO:
All Serial Numbers
SUMMARY:
This Instruction will eliminate a nuisance power source fault light when connecting a DuraDrive
4-30 or 4-48 wire feeder. The fault condition is caused by a transient voltage spike in the 12
volt control circuit when power is applied to the DuraDrive feeder. An additional 22 microfarad
capacitor is added to increase the time constant of the power up reset circuit which eliminates
the false triggering of the fault light.
OPERATIONAL IMPACT:
None