Extron Cable Cubby 202 User manual

  • Hello! I am an AI chatbot trained to assist you with the Extron Cable Cubby 202 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
1
IMPORTANT:
Go to www.extron.com for the
complete user guide
, installation
instructions, and specifications.
Cable Cubby 202 • Installation Guide
This guide provides instructions for an experienced installer to install and connect the
Extron Cable Cubby 202 Cable Access Enclosures.
The Cable Cubby units are furniture-mounted enclosures for cable access,
connections, and AC power. Cables that are not in use can be stored out of
the way while remaining connected to the presentation system.
Planning
Check with local and state regulations before
starting the installation:
Ensure that the planned installation complies with building and
electrical codes.
Ensure that the planned installation complies with the Americans with Disabilities
Act or other accessibility requirements.
Check all parts and equipment before installation:
Ensure that all parts are present in each kit.
Ensure that necessary tools and equipment are available for the installation.
Preparing the Table
Cut a hole in the surface where the enclosure will be installed. Read the following information before making a cut.
Determine the best location for the enclosure
Ensure that the location where the Cable Cubby is to be installed is convenient for as many users as possible.
Ensure that the edge on which the lid opens is oriented correctly.
Ensure that there is ample space under the table for cables.
Choose a method for cutting the hole in the table
See the next page for details on cutting the hole in the table.
CABLE CUBBY
Kit Contents
Grommet Plugs
(3) 3/8", (1) 1/4"
AC Cord
Retainer Clip
(Non-US models only)
Cable Grommet Plate
and #4-40 Plate Screws
Cable Cubby 202
Mini AAP and #4-40 Mounting
Screws (US model only)
2
Cable Cubby 202 • Installation Guide (Continued)
Preparing the Cable Cubby
Assemble the cable pass-through plate and (for US models) install a Mini AAP.
Choose one of the following methods for cutting the hole:
Hand Router and Routing Template Jigsaw and Paper Cut-Out Template CNC Wood Router
If using a CNC wood router or
other precise machinery, use the
exact cut-out dimensions (see the
table below).
Visit www.extron.com for Cable Cubby
routing template part numbers and
instructions.
Dimensions and cut-out templates are
available online at www.extron.com.
The opening in the table for the Cable Cubby should be cut only by licensed and bonded craftspeople.
CAUTION: Wear safety glasses when operating power equipment. Failure to comply can result in eye injury.
ATTENTION: Portez des lunettes de sécurité lorsque vous utilisez l’équipement électrique. Ne pas respecter cela peut
conduire à une blessure à l’oeil.
Cut-out Dimensions
User Access
Width
Side Dimension
7.0"
(17.8 cm)
3.25"
(8.3 cm)
3
US models only:
Install a Mini AAP into the
opening by the AC connection.
Connect AV cables to the
Mini AAP if necessary, and
secure the plate using the
provided mounting screws.
2
Insert the assembled plate into the
enclosure and secure the plate, using
the included plate screws.
1
Assemble the cable pass-through
plate with your choice of AV cables.
Snap the included hole plugs into
any unused holes.
Cut-Out Template for the Extron
Cable Cubby 202
User Access
0.00” (0.00 cm)
0.02 (0.05 cm)
+
Outer Edge of Front Bezel
(Do not cut this line.)
1. Confirm the product to be installed.
2. Remove the surface cut-out area
(gray) from the template.
3. Measure the cutout and template.
4. Mark the position on the
furniture where the Cable Cubby 202
will be installed.
5. Double check dimensions and position,
then cut the opening.
P/N ??-????-01 Rev. A
Page size: 11" x 17"
Print scale 1:1
Do not shrink.
3.25"
(8.25 cm)
7.0"
(17.78 cm)
SURFACE
CUT-OUT
AREA
Cut-Out Radi
u
s:
0.25"
(0.6 cm)
Cut-Out T
Cab
Cut-Out Template for the Extron
Cable Cubby 202
User Access
0.00” (0.00 cm)
0.02 (0.05 cm)
+
Outer Edge of Front Bezel
(Do not cut this line.)
1. Confirm the product to be installed.
2. Remove the surface cut-out area
(gray) from the template.
3. Measure the cutout and template.
4. Mark the position on the
furniture where the Cable Cubby 202
will be installed.
5. Double check dimensions and position,
then cut the opening.
P/N ??-????-01 Rev. A
Page size: 11" x 17"
Print scale 1:1
Do not shrink.
3.25"
(8.25 cm)
7.0"
(17.78 cm)
SURFACE
CUT-OUT
AREA
Cut-Out Radi
u
s:
0.25"
(0.6 cm)
Cut-Out T
Cab
3
Mounting and Installing the Cable Cubby in the Table
CAUTION: The anged edges of the top of the surface enclosure are sharp. These edges are also soft and may be easily
nicked or bent. Exercise caution when handling the enclosure to prevent personal injury or damage to the enclosure.
ATTENTION: Les extrémités à brides du haut de la surface du boîtier sont aiguisées. Ces extrémités sont aussi lisses
et peuvent facilement être coupées ou pliées. Soyez prudents lorsque vous manipulez le boîtier an d’éviter de
l’endommager ou de vous blesser.
Ensure that the Cable Cubby is rmly seated in the table.
Using a screw driver or drill, turn the clamp screw clockwise
and slowly tighten it to secure the enclosure to the surface.
Lower the Cable Cubby into the hole
to test the t. If necessary, carefully
enlarge the opening.
Remove the plastic strips and lm on the
surface of the Cable Cubby.
Ensure that the side clamps are
seated against the enclosure.
se
1
2
3
4
ATTENTION: When tightening the clamp screws, do not
exceed a torque rating of 5 inch-pounds. Overtightening
can damage the clamp mechanism and enclosure.
ATTENTION: Lors du serrage des pinces à vis, veillez à ne
pas dépasser une valeur de couple de 5 livres par pouce.
Un serrage excessif pourrait endommager le dispositif ainsi
que le boîtier.
Ensure that the Cable Cubby is rmly seated in the table.
Using a screwdriver, turn the clamp screw clockwise
and slowly tighten it to secure the enclosure to the surface.
Lower the Cable Cubby into the hole
to test the t. If necessary, carefully
enlarge the opening.
Remove the plastic strips and lm on the
surface of the Cable Cubby.
Ensure that the side clamps are
seated against the enclosure.
En
se
1
2
3
4
4
68-2486-01
Rev. B
08 16
Routing and Connecting Cables
Installation Checklist
Planning (page 1)
Check with local and state regulations before starting the installation.
Check all parts and equipment before installation.
Preparing the Table (pages 1 and 2)
Determine the best location for the enclosure.
Choose a method for cutting the hole in the table.
Preparing the Cable Cubby (page 2)
Assemble the cable pass-through plate and (for US models) install a Mini AAP.
Mounting and Installing the Cable Cubby in the Table (page 3)
Routing and Connecting Cables (page 4)
NOTE:
For cable pass-through
applications, allow at least
36 inches (0.9 m) of cable
loop for each cable.
Ensure that there is no
tension on the power cable.
Connect cables to the AV
system
and connect the AC power cord.
Use zip ties to secu
re
cables to the r
ectangular
holes in r
ear of Cable
Cubb
y.
1
2
Cable Retainer for Non-US Models
For non-US models, secure the power cable with
the included cable retainer as shown below.
1
2
CAUTION:
Risk of Electric Shock.
This equipment must be
grounded.
ATTENTION:
Risque de choc électrique.
Cet équipement doit être xé
au sol.
Extron Headquarters
+800.633.9876 Inside USA/Canada Only
Extron USA - West Extron USA - East
+1.714.491.1500 +1.919.850.1000
+1.714.491.1517 FAX +1.919.850.1001 FAX
Extron Europe
+800.3987.6673
Inside Europe Only
+31.33.453.4040
+31.33.453.4050 FAX
Extron Asia
+65.6383.4400
+65.6383.4664 FAX
Extron Japan
+81.3.3511.7655
+81.3.3511.7656 FAX
Extron China
+86.21.3760.1568
+86.21.3760.1566 FAX
Extron Middle East
+971.4.299.1800
+971.4.299.1880 FAX
Extron Australia
+61.8.8351.2188
+61.8.8351.2511 FAX
Extron India
1800.3070.3777
(Inside India Only)
+91.80.3055.3777
+91.80.3055.3737 FAX
© 2016 Extron Electronics All rights reserved. All trademarks mentioned are the property of their respective owners. www.extron.com
/