American Standard Ceramix 2021.831 User manual

Category
Sanitary ware
Type
User manual

This manual is also suitable for

Certified to comply with ASME A112.18.1M
Installation
Instructions
TM
0
1
2
3
4
5
6
M66241 REV.1.1
Turn off hot and cold water supplies before beginning.
CAUTION
1
1
2
3
4
5
6
7
8
KITCHEN FAUCETS
HI-FLOW SPOUT
2021.831
FAUCET INSTALLATION
This faucet permits an interchangeable mounting of
each integral component -- spout, valve, and hand spray--
to suit the particular installation requirements.
Before starting installation, place each component
loosely into the holes of the kitchen sink to select the
most desirable arrangement.
VALVE INSTALLATION
Remove VALVE NIPPLE (1),
SEAL WASHER (2), LOCKNUT (3)
and MOUNTING ASSEMBLY (4) from
threaded STUD (5) of valve.
Insert supply TUBES (6) and threaded
STUD (5) through hole in sink.
Make sure black RUBBER RING (7)
is properly seated in recess of base.
Orient valve so that threaded STUD (5)
is centrally located towards the rear of
sink, then assemble MOUNTING
ASSEMBLY (4) and thread LOCKNUT (3)
onto STUD (5) from underside of sink.
Hand tighten LOCKNUT (3) and check
that rotation of HANDLE (8) from HOT
to COLD is centered. Secure valve
position by tightening LOCKNUT (3)
firmly (spread TUBES (6) for better
access to LOCKNUT (3).
Bend TUBES (6) to meet supplies. Use
palm of hand to support TUBES (6)
while bending to avoid kinking.
Attach VALVE NIPPLE (1) with SEAL
WASHER (2) to threaded STUD (5).
9-9/16
8-9/16
10
1-1/16 MAX
1-1/4 MAX
1-3/4 MAX
1-1/8 DIA
HOT COLD
3/8 OD COPPER
BENDABLE
C/L OF
FLEXIBLE HOSE
TO SPOUT
MTG SURFACE
VALVE
1-1/4 MIN DIA
MTG HOLE
2-3/16
DIA
13-7/8
12
MAX
ROUGHING-IN
DIMENSIONS
27/32
DIA.
2 DIA.
12" MAX
2
RECESS
TOOLS REQUIRED
Phillips Screwdriver
Plumbers' Putty or Caulking
Adjustable Wrench
Channel Locks
Thank you for selecting American-Standard...
the benchmark of fine quality for over 100 years.
To ensure that your installation proceeds smoothly--
please read these instructions carefully before you begin.
0
1
2
3
4
5
6
4
Feed SPRAY HOSE (8) through SPRAY HOLDER (6) and attach COUPLING
NUT (9) of SPRAY HOSE (8) to HOSE ADAPTER (10). Tighten COUPLING
NUT firmly (9).
Make certain that SPACER WASHER (11) and RUBBER WASHER (12)
are attached to SPRAY HOSE (8) and thread SPRAY HEAD (13) to NUT (14).
Tighten NUT (14) firmly.
Place SPRAY HOLDER (6) into the appropriate mounting hole,
assemble WING NUT (7) onto shank of SPRAY HOLDER (6)
from underside of sink and secure by tighting WING NUT (7).
M66241 REV.1.2
2
SPOUT BASE INSTALLATION
3
Remove ESCUTCHEON (1) with RUBBER
RING (2) and insert SPOUT BASE (3) through
hole from underside of Sink. Threads
of SPOUT BASE (3) should extend at least
5/16-inch above mounting surface. If necessary,
adjust LOCKNUT (4).
Place RUBBER RING (2) into ESCUTCHEON (1)
recess and thread ESCUTCHEON (1) onto
SPOUT BASE (3) until snug against
internal stop.
Turn SPOUT BASE (3) so that the side
INLET NIPPLE (5) is directed towards
valve. Center SPOUT BASE (3) and
tighten LOCKNUT (4).
Place SEAL WASHERS (6) into coupling
nuts of FLEXIBLE HOSE (8) and connect to
side INLET NIPPLE (5) and VALVE NIPPLE (7).
5/16'' MIN.
RUBBER WASHER
SINK OR
MOUNTING
SURFACE
6
1
5
4
3
7
9
10
13
12
11
14
8
1
2
3
4
5
6
6
8
7
SPOUT INSTALLATION
5
SUPPLY CONNECTIONS
Check that both O-RINGS (1) are properly seated on the
valve center.
Check that the DIVERTER PLUG (2) is free and can move
up and down.
Push the SPOUT SUB-ASSEMBLY (3) on to the SPOUT BASE (4)
and tighten the SPOUT NUT (5) until snug on SPOUT BASE (4).
INSTALL
Note: If additional supply length is required, installer must purchase
additional parts separately.
Bend 3/8” SUPPLY TUBES to meet water supplies valves.
Use palm of hand to support TUBES while bending to avoid kinking.
Connect inlet TUBES to water supplies with appropriate connectors.
Connect left TUBE to HOT water supply, and the right TUBE to the
COLD water supply.
COMPRESSION
NUT
3/8 O.D.
SUPPLIES
FERRULE
COLD
HOT
6
7
TEST INSTALLED FITTING
8
ADJUST HOT LIMIT STOP
By restricting handle rotation and limiting the amount of
hot water allowed to mix with the cold, the HOT LIMIT
SAFETY STOP reduces risk of accidental scalding. To set
the maximum hot water temperature of your faucet,
all you need to do is adjust the setting on the HOT LIMIT
SAFETY STOP (1).
Use a flat blade screwdriver or your fingers to pull up and
rotate red HOT LIMIT SAFETY STOP (1). Follow Step "A" or
"B" to adjust min./max. discharge temperature. "0" being
the hottest to "7" the coldest temperature setting. Factory
set at "0".
With HANDLE (1) in OFF position, turn on
WATER SUPPLIES (2) and check all
connections for leaks.
Remove AERATOR (3).
Operate HANDLE (1) up and down, in COLD and HOT
positions, to flush water lines thoroughly.
Direct SPRAY HEAD (4) into sink. Open faucet and
activate spray. Check SPRAY HOSE (5) connections
for leaks.
Replace AERATOR (3).
9
PRY RED RING UPWARD
AND ROTATE COUNTER-
CLOCKWISE ONE CLICK
PRY RED RING UPWARD
AND ROTATE CLOCKWISE
"A"
ADJUSTMENT WHEN
WATER IS TOO HOT
"A"
"A"
"B"
"B"
ADJUSTMENT WHEN
WATER IS TOO COLD
"B"
"RED RING"- HOT
LIMIT SAFETY STOP
TEMPERATURE
SETTING NUMBERS
0
1
2
3
4
5
6
1
M66241 REV.1.2
3
2
1
5
4
Clogged CARTRIDGE (1) inlets or outlets may cause reduced
flow in "full on," hot or cold. To clean ports, first turn off Hot
and Cold water supplies, then:
Remove BUTTON (2), loosen HANDLE SCREW (3) and pull
HANDLE (4) off.
Remove ESCUTCHEON CAP (5).
Lift CARTRIDGE (1) off MANIFOLD (7), remove SEALS (8).
Clean ports, SEALS (8).
Replace ESCUTCHEON CAP (5), HANDLE (4), and tighten
HANDLE SCREW (3). Replace PLUG BUTTON (2).
Remove three MOUNTING SCREWS (6).
Insert SEALS (8) back into CARTRIDGE (1). Place CARTRIDGE
(1) onto MANIFOLD (7) and alternately tighten the three
MOUNTING SCREWS (6).
If hand spray water
flow is restricted, lift
DIVERTER (10) using
long-nose pliers. Clean
and replace.
If faucet drips, operate HANDLE (4) several times from
"off" to "on." Do not apply excessive force.
AERATOR (9) may accumulate dirt causing distorted and reduced
water flow. Remove, clean, and replace AERATOR (9).
1
7
2
3
5
6
8
9
4
10
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
CARE INSTRUCTIONS:
  • Page 1 1
  • Page 2 2
  • Page 3 3

American Standard Ceramix 2021.831 User manual

Category
Sanitary ware
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI