American Standard Ceramix 2021.6XX is convenient and easy to install. The adjustable hot limit safety stop enables you to reduce the risk of accidental scalding. In case of a clogged cartridge, you can clean the ports without removing the cartridge. If hand spray water flow is restricted, simply lift the diverter using long-nose pliers, clean, and replace it. The aerator can be removed, cleaned, and replaced if water flow is distorted or reduced. If the faucet drips, operate the handle several times from "off" to "on" without applying excessive force.

American Standard Ceramix 2021.6XX is convenient and easy to install. The adjustable hot limit safety stop enables you to reduce the risk of accidental scalding. In case of a clogged cartridge, you can clean the ports without removing the cartridge. If hand spray water flow is restricted, simply lift the diverter using long-nose pliers, clean, and replace it. The aerator can be removed, cleaned, and replaced if water flow is distorted or reduced. If the faucet drips, operate the handle several times from "off" to "on" without applying excessive force.

Certified to comply with ASME A112.18.1M
Installation
Instructions
TM
0
1
2
3
4
5
6
KITCHEN FAUCETS
2021.6XX
FAUCET INSTALLATION (ESCUTCHEON OPTIONAL)
Insert supply TUBES (1) and threaded MOUNTING STUD (2)
through center hole of ESCUTCHEON (3) and sink deck, or selected
sink hole if ESCUTCHEON (3) is not used.
Make sure black RUBBER GASKET (4) is properly centered on base.
Orient faucet so that threaded STUD (2) is centrally located towards
rear of sink, then assemble RETAINER PLATE with GASKET (5), or
MOUNTING KIT (5a) and thread LOCKNUT (6, 6a) onto MOUNTING
STUD (2) from underside of sink.
Hand tighten LOCKNUT (6, 6a) and check that rotation of HANDLE (7)
from HOT to COLD is centered. Secure faucet by tightening LOCKNUT
(6, 6a) firmly. Spread TUBES (1) for better access to LOCKNUT (6, 6a).
If using ESCUTCHEON (3), thread ESCUTCHEON WING NUTS (8) onto
studs from underside of sink and hand-tighten.
2
M66240 REV.1.1
Peel off paper backing from WASHER (1, 1a) and stick WASHER
(1, 1a) into circular groove of the SUPPORT PLATE (2, 2a).
REAR EDGE
4
4
6
5
3
3a
3a
INSTALL
Place SUPPORT PLATE (2, 2a) in
center of ESCUTCHEON (3, 3a)
with WASHER (1) visible.
Turn ESCUTCHEON (3, 3a) over
with notch of SUPPORT
PLATE (2, 2a) towards rear of
sink, align STUDS (4) with
outer holes of sink and
place ESCUTCHEON (3, 3a) onto
deck. Hole of SUPPORT
PLATE (2, 2a) must align with
hole of sink.
FOR MODEL 2021.631 ONLY:
Install ESCUTCHEON (3a) (as described on the left).
Insert SPRAY HOLDER (5) through side hole of installed
ESCUTCHEON (3a), thread WING NUT (6) to shank of SPRAY
HOLDER (5) from underside of sink. Center SPRAY HOLDER (5)
on ESCUTCHEON (3a) and secure by tightening WINGNUT (6).
1
1
1
2
2
3
2a
Install ESCUTCHEON (optional)
REAR EDGE
INSTALL
1
5
5a
5
8
6
6
6a
6a
4
4
7
LOCKNUT
(FAUCETS
LESS SPRAY)
MOUNTING KIT
FOR FTG. WITH
HAND SPRAY
LOCKNUT
LESS ESCUTCHEON
TOOLS REQUIRED
Phillips Screwdriver
Plumbers' Putty or Caulking
Adjustable Wrench
Channel Locks
Thank you for selecting American-Standard...
the benchmark of fine quality for over 100 years.
To ensure that your installation proceeds smoothly--
please read these instructions carefully before you begin.
Turn off water at
main supply.
CAUTION
WATER SUPPLY CONNECTIONS
0
1
2
3
4
5
6
If faucet drips, operate HANDLE (4) several times from
"off" to "on." Do not apply excessive force.
4
3
HAND SPRAY INSTALLATION
5
SERVICE
FOR MODELS WITH HAND SPRAY ONLY:
ALL MODELS:
Feed SPRAY HOSE (5) through SPRAY HOLDER (1) and attach COUPLING
NUT (4) of SPRAY HOSE (5) to MOUNTING STUD (3). Tighten COUPLING
NUT (4) firmly.
Make certain that SPACER WASHER (6) and RUBBER WASHER (7)
are attached to SPRAY HOSE (5) and thread SPRAY HEAD (9) to
NUT (8). Tighten COUPLING NUT (8) firmly.
Place SPRAY HOLDER (1) into the appropriate mounting hole,
assemble WING NUT (2) onto shank of SPRAY HOLDER (1)
from underside of sink and secure by tighting WING NUT (2).
M66240 REV.1.1
1
8
9
7
6
2
Note: If additional supply length is required, installer must purchase
additional parts separately.
Bend 3/8” SUPPLY TUBES to meet water supplies valves.
Use palm of hand to support TUBES while bending to avoid kinking.
Connect inlet TUBES to water supplies with appropriate connectors.
Connect left TUBE to HOT water supply, and the right TUBE to the
COLD water supply.
COMPRESSION
NUT
3/8 O.D.
SUPPLIES
FERRULE
COLD
HOT
3
5
1
2
3
4
5
6
7
8
12
13
14
9
10
11
4
AERATOR (14) may accumulate dirt causing distorted
and reduced water flow. Remove, clean, and replace
AERATOR (14).
Clogged CARTRIDGE (1) inlets or outlets
may cause reduced flow in "full on,"
hot or cold. To clean ports, first turn
off Hot and Cold water supplies, then:
Remove BUTTON (2), loosen HANDLE
SCREW (3) and pull HANDLE (4) off.
Remove ESCUTCHEON CAP (5).
Lift CARTRIDGE (1) off
MANIFOLD (7), remove
SEALS (8). Clean ports,
SEALS (8), FLOW
REGULATOR (9) and
MANIFOLD (7).
If hand spray water
flow is restricted, lift
DIVERTER (10) using long-
nose pliers. Clean
and replace.
Replace ESCUTCHEON CAP (5), HANDLE (4), and tighten HANDLE
SCREW (3). Replace PLUG BUTTON (2).
To replace SPOUT SEALS (11), remove CARTRIDGE (1)
as described on the left, then:
Remove three MOUNTING SCREWS (6).
Insert SEALS (8) back into CARTRIDGE (1).
Make certain larger diameter of FLOW
REGULATOR (9) faces inside CARTRIDGE (1).
Place CARTRIDGE (1) onto MANIFOLD (7) and
alternately tighten the three MOUNTING SCREWS (6).
Slip SPOUT (12) off MANIFOLD (7) and replace LIP
SEALS (11) and BEARING RING (13). Make certain
SEALS (11) are well lubricated.
For assembly, proceed as above in reverse order.
6
TEST INSTALLED FITTING
7
ADJUST HOT LIMIT STOP
By restricting handle rotation and limiting the amount of hot water allowed to mix with the cold, the HOT LIMIT
SAFETY STOP reduces risk of accidental scalding. To set the maximum hot water temperature of your faucet,
all you need to do is adjust the setting on the HOT LIMIT SAFETY STOP (1).
Use a flat blade screwdriver or your fingers to pull up and rotate red HOT LIMIT SAFETY STOP (1). Follow Step "A" or
"B" to adjust min./max. discharge temperature. "0" being the hottest to "7" the coldest temperature setting. Factory
set at "0".
With HANDLE (1) in OFF position, turn on
WATER SUPPLIES (2) and check all
connections for leaks.
Remove AERATOR (3).
Operate HANDLE (2) up and down, in COLD and HOT
positions, to flush water lines thoroughly.
Direct SPRAY HEAD (3) into sink. Open faucet and
activate spray. Check SPRAY HOSE (4) connections
for leaks.
Replace AERATOR (3).
8
PRY RED RING FORWARD
AND ROTATE COUNTER-
CLOCKWISE ONE CLICK
PRY RED RING FORWARD
AND ROTATE CLOCKWISE
"A"
ADJUSTMENT WHEN
WATER IS TOO HOT
"A"
"A"
"B"
"B"
ADJUSTMENT WHEN
WATER IS TOO COLD
"B"
"RED RING"- HOT
LIMIT SAFETY STOP
TEMPERATURE
SETTING NUMBERS
0
1
2
3
4
5
6
1
M66240 REV.1.1
1
3
2
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL
CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS,
OR A CLOTH WITH A COARSE SURFACE.
CARE INSTRUCTIONS:
  • Page 1 1
  • Page 2 2
  • Page 3 3

American Standard Ceramix 2021.6XX User manual

Category
Sanitary ware
Type
User manual
This manual is also suitable for

American Standard Ceramix 2021.6XX is convenient and easy to install. The adjustable hot limit safety stop enables you to reduce the risk of accidental scalding. In case of a clogged cartridge, you can clean the ports without removing the cartridge. If hand spray water flow is restricted, simply lift the diverter using long-nose pliers, clean, and replace it. The aerator can be removed, cleaned, and replaced if water flow is distorted or reduced. If the faucet drips, operate the handle several times from "off" to "on" without applying excessive force.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI