M968208 REV. 1.4
Remove BUTTON (2) and loosen HANDLE SCREW (2) and pull off HANDLE (3).
Remove ESCUTCHEON CAP (4) by pulling it upward. Unscrew the three
CARTRIDGE SCREWS (5) and remove CARTRIDGE (6).
Clean inlets of CARTRIDGE (6) and MANIFOLD (7).
Reassemble CARTRIDGE (6), alternately tightening SCREWS (5). Replace
CAP (4) and HANDLE (3), check flow.
SERVICE
Clogged CARTRIDGE outlets or inlets may cause reduced flow.
To clean, first turn off water supply then:
Reduced flow. If the flow should gradually be reduced over a number of months,
the AERATOR may have debris in it. To clean, remove AERATOR (1) and rinse with
water to remove any debris. Turn on faucet to wash any debris out of the faucet.
Screw AERATOR (1) back to the spout. Operate faucet.
4
5
7
1
2
4
3
TEST INSTALLED FAUCET
5
6
Move HANDLE (1) down into "off"
position.
With HANDLE (1) down in "off"
position.
Turn on water supplies and check
all connections for leaks.
Operate handle up and down, in COLD
and HOT positions, to flush water lines
thoroughly.
Connect HAND SPRAY (2) to HOSE
END (4). Place HAND SPRAY (2)
back into faucet, operate HANDLE (1)
and check all connections for leaks.
Pull HAND SPRAY (2) from FAUCET (5)
and disconnect HAND SPRAY (2). Pull
HOSE (3) (HOSE should pull
approximately 2 feet) and direct open
HOSE END (4) into sink.
Check HAND SPRAY (2) operation:
With faucet on push front of
BUTTON for a broad cleansing
spray.
1
3
5
2
4
CHECK CONNECTIONS
FOR LEAKS
6
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
CARE INSTRUCTIONS: