  • Hello! I have reviewed the installation instructions for the Anolis AMBIANE SP16 Recessed Tiltable lighting unit. This document outlines the necessary steps to correctly install this device, from preparing the mounting hole to securing the luminaire. I can help you with any questions you might have about specific instructions, connections, or features outlined in the manual.
  • What is the required diameter for the mounting hole?
    Can the fixture be controlled by DMX or DALI?
    Who should install the unit?
INSTALLATION INSTRUCTIONS
AMBIANE SP16 RECESSED TILTABLE
ROBE lighting s. r. o. | Palackeho 416 | 757 01 Valasske Mezirici | Czech Republic | Tel.: +420 571 751 500 | E-mail: inf[email protected] | www.anolislighting.com
VERSION 1.0 / 10_2023 1
QR code for Installations Instructions
INSTALLATION INSTRUCTIONS
AMBIANE SP16 RECESSED TILTABLE
ROBE lighting s. r. o. | Palackeho 416 | 757 01 Valasske Mezirici | Czech Republic | Tel.: +420 571 751 500 | E-mail: inf[email protected] | www.anolislighting.com
VERSION 1.0 / 10_2023 2
STEP 1
CEILING OPENING
Prepare mounting hole with diameter of 115mm.
The unit must be installed by a qualied electrician in accordance with all national and local
electrical and construction codes and regulations.
Place control unit above the ceiling.
STEP 2
CONTROL UNIT MOUNTING
Mount the control unit to ceiling via two mounting holes and
suitable fasteners.
1 2
Strip these lengths of cable for wiring connection.
1
Shorten power/data cable to required length.
2
STEP 3
PREPARE CONNECTION
Install terminal block to power cable (from Ambiane Power Rack
or Ambiane Power AP) and connect it to Primary power socket
of the control unit.
STEP 4
PRIMARY POWER CONNECTION
PRIMARY POWER CONNECTION
TERMINAL BLOCK 0V VCC
Colour of Wire Power - Power +
1
INSTALLATION INSTRUCTIONS
AMBIANE SP16 RECESSED TILTABLE
ROBE lighting s. r. o. | Palackeho 416 | 757 01 Valasske Mezirici | Czech Republic | Tel.: +420 571 751 500 | E-mail: inf[email protected] | www.anolislighting.com
VERSION 1.0 / 10_2023 3
STEP 5
DATA (DMX OR DALI) AND SECONDARY POWER
CABLES CONNECTION
Install terminal blocks on SECONDARY POWER and DATA ca-
bles and connect them to the control unit.
Set the DIP switches to positions according to your operation
mode. The xture can be controlled by DMX or DALI (switch
11 in OFF position).
DMX CONNECTION
TERMINAL BLOCK 0V D- D+
Function Data Ground Data - Data +
SECONDARY POWER CONNECTION
TERMINAL BLOCK 0V VCC
Colour of Wire Power - Power +
STEP 6
LED UNIT CONNECTION
Pull the cable through the hole. Install terminal block on LED
unit‘s cable and connect it to the control unit.
LED Unit Connection
TERMINAL
BLOCK + A B -
Colour of Wire Red White Blue Black
STEP 7
AMBIANE MOUNTING
Lift up spring clips on both sides. Insert luminaire into ceiling
opening. Release spring clips to hold lumaire in place.
12
/