INSTALLATION INSTRUCTIONS
ROBE lighting s. r
. o
. | P
alackeho 416 | 757 01
Valasske Mezirici | Czech R
epublic | T
el.: +420 571 751 500 | E-mail:
[email protected]www.anolis.eu www.anolislighting.com
AMBIANETM AP
4
VERSION 1 / 24_05_2021
2
STEP 3
DATA CONNECTION (DMX OR DALI)
DMX CONNECTION
0V D- D+
Data Ground Data - Data +
1
2
Set the DIP switches to positions according to your operation
mode. The fixture can be controlled by DMX or DALI.
Set 11=OFF for control by DMX or DALI.
STEP 5
DIP SWITCH
1
Unscrew 2 screws on the control unit and remove plastic cover.
Install terminal blocks on cable and connect it to the control unit.
STEP 4
SECONDARY POWER CONNECTION 48V
Lift up springs on both sides, insert luminaire into ceiling opening
and release springs to hold lumaire in place.
STEP 6.A
LUMINAIRE INSTALLATION
Make sure power and data cables are connected before
this step.
Install terminal blocks on DMX or DALI cables and connect them
to the control unit.
1